Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA SPECTROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fission Product Gas Monitoring During Fuel Drying Operations - 20094

The goal of the project was to devise and implement a method of accurately qualifying any noble gas emitted during fuel drying operations (part of the dry fuel storage process) in order to provide the data needed to validate the off-site dose calculations. The imputes of the project was the NRC publishing Information Notice 18-01, 'Noble Fission Gas Releases During Spent Fuel Cask Loading Operations' in February 2018. The information notice describes some industry events that occurred during vacuum drying operations as part of a dry fuel campaign. The solution was devised by Fort Calhoun Station staff in partnership with Mirion Technologies technical staff. The monitoring was accomplished by directing all the effluent from the fuel storage cask vacuum drying machine through a sample chamber containing a compact ISOCS characterized CZT based gamma spectrometer connected to a Mirion Data Analyst. This resulted near real-time quantification of the radionuclides of concern. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Data-Driven Optimization of Pixelated CdZnTe Spectrometers for Uranium Enrichment Assay

Here, in recent work [Vavrek et al. (2025)], we developed the performance optimization framework spectre-ml for gamma spectrometers with variable performance across many readout channels. The framework uses non-negative matrix factorization (NMF) and clustering to learn groups of similarly-performing channels and sweep through various learned channel combinations to optimize the performance tradeoff of including worse-performing channels for better total efficiency. In this work, we integrate the pyGEM uranium enrichment assay code with our spectre-ml framework, and show that the U-235 enrichment relative uncertainty can be directly used as an optimization target. We find that this optimization reduces relative uncertainties after a 30 -minute measurement by an average of 20%, as tested on six different H3D M400 CdZnTe spectrometers, which can significantly improve uranium non-destructive assay measurement times in nuclear safeguards contexts. Additionally, this work demonstrates that the spect re-ml optimization framework can accommodate arbitrary end-user spectroscopic analysis code and performance metrics, enabling future optimizations for complex Pu spectra.

Gamma-ray detection↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Rod Length Gamma Spectroscopy Measurements of LWR Used Fuel Rods

Twenty-five high-burnup pressurized water reactor used fuel rods were scanned in the Irradiated Fuels Examination Laboratory at Oak Ridge National Laboratory with a high-resolution gamma spectrometer. A planar high-purity germanium detector was used across an energy range from 60 keV to 3 MeV. Gamma spectra of individual fuel rods were collected in 4.5 mm steps along the entire length of each rod. Additional spectra were collected on select rods in rotational increments of 30 degrees to provide data on the distribution of fission products along the rod perimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A safeguards approach for molten salt reactors: Direct gamma-spectrometry of 233 U

Multidimensional gamma-spectrometry is a potential solution for safeguarding future thorium-fueled molten salt reactors (MSRs). A high-sensitivity system developed at Pacific Northwest National Laboratory (PNNL), the Advanced Radionuclide Gamma spectrOmeter (ARGO), has demonstrated direct 233 U assay in freshly irradiated fuel salt samples using a dual-detector configuration and the 97.1 keV gamma-emission. These measurements were made using 1.4 x 10 6 Bq of 233 U activity (at 1.4 x 10 8 fissions), at relatively high dead times (10.4%), and using short count durations of ~800 s. Other major emissions were also evaluated (42.5 keV, 54.7 keV, 146.4 keV), in additional to limited (1.96%) Compton suppression, but provided less consistent determination of the 233 U activity. Accurate 233 U measurement was also demonstrated using its four coincidence gamma-emissions (42.5 keV, 54.7 keV; 42.5 keV, 278.1 keV; 146.4 keV, 174.2 keV; 146.4 keV, 219 keV). Further improvements in coincidence measurements may be achievable with improvements in the detector configuration and nuclear data. Whilst this demonstration utilized the ARGO laboratory system, a similar dual-detector configuration could be utilized for online safeguards measurements.

Gamma-spectrometry↗

H 2 generation by the 10 B(n,α) 7 Li reaction in high temperature water

H 2 produced in water from the 10 B(n,α) 7 Li fission reaction has been measured up to 300 °C. Thermal energy neutrons from the Rhode Island Nuclear Science Center's 2 MW reactor interact with boric acid-containing water in temperature-controlled high-pressure cells made from tubing of either titanium or zirconium alloy. After exposure for a minimum of 1 h, the solution sample is extracted and sparged with argon. The H 2 entrained by the sparging gas is sampled with a small mass spectrometer. A small amount of sodium is included in the boric acid solution so that after sparging, samples can be collected for 24 Na activation measurements in a gamma spectrometer to determine the neutron exposure and thus the total energy deposited in solution. The G-value (μmol/J) for H 2 production is obtained for water at a pressure of 25 MPa, over a temperature range from 20 °C to 300 °C. The weak temperature dependence of this yield between 150 °C and 200 °C demonstrates that the bimolecular reaction of pairs of e$^{–}_{aq}$ is a very minor source of H 2 in high LET tracks.

10B↗

Gamma-based nuclear fusion measurements at inertial confinement fusion facilities

Experiments performed on an inertial confinement fusion (ICF) platform offer a unique opportunity to study nuclear reactions, including reaction branches that are useful for diagnostic applications in ICF experiments as well as several that are relevant to nuclear astrophysics. In contrast to beam-accelerator experiments, experiments performed on an ICF platform occur over a short time scale and produce a plasma environment with physical parameters that are directly relevant to big bang and/or stellar nucleosynthesis. Several reactions of interest, such as D(T,γ) 5 He, H(D,γ) 3 He, H(T,γ) 4 He, and T( 3 He,γ) 6 Li produce high-energy gamma rays. S factors or branching ratios for these four reactions have recently been studied using various temporally-resolved Cherenkov detectors at the Omega laser facility. This work describes these detectors as well as the current standard technique for performing these measurements. Recent results for reactions D(T,γ) 5 He, H(D,γ) 3 He, H(T,γ) 4 He, and T( 3 He,γ) 6 Li are reviewed and compared to accelerator-based measurements. Limitations associated with implosion experiments and use of the current standard gamma detectors are discussed. A basic design for a gamma spectrometer for use at ICF facilities is briefly outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and performance evaluation of a novel γ-γ coincidence analysis software

Processing of large amounts of data from a γ-γ coincidence system is a practical challenge in trace-level radionuclide measurements. Given the benefits and growing number of multidimensional gamma spectrometers worldwide, this is a major restriction in wide-spread applicability of coincidence techniques. This study demonstrates a novel γ-γ coincidence analysis software developed at Pacific Northwest National Laboratory, USA. The software utilizes advanced search techniques and Python libraries to readily identify coincidence signatures in the large data. Further, using both synthetic and experimental data, the study uncovers various strategies/libraries employed during software’s development. This work aims to provide a reference document in handling large data routinely encountered in trace-level measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constrained Tomographic Reconstructions of Gamma Scans in AGR 5/6/7 Capsules

We demonstrate a novel approach to locate potential areas of interest within individual capsules in the Advanced Gas Reactor 5/6/7 experiment. Individual capsules from the experiment have been scanned for gamma-emitting radioisotopes using the precision gamma spectrometer at Idaho National Laboratory’s hot fuel examination facility. Only a small number of scans were available, fewer than ten scan angles as opposed to a typical three hundred, so a geometry-informed algebraic reconstruction technique was used to provide qualitative information on high-activity regions in the capsule. While results are non-quantitative, some qualitative conclusions are drawn.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stochastic Approaches for Calculating and Aggregating Detection Probabilities for Nuclear Material Diversion

The authors built and tested a stochastic simulation to estimate achieved detection probabilities (DPs) on a stratum basis, over a tailorable range of diverted amounts from 0 to 2 significant quantities (SQ), using typical International Atomic Energy Agency (IAEA) inspection data: i.e., SQ in stratum, number of items, number of gross/partial/bias defect measurements conducted, and realistic relative standard deviation (RSD) values for typical IAEA verification measurements. For bulk strata, the model calculates achieved DP at 0.01 SQ diversion increments; for item strata, the model calculates DP using the smallest realistic diversion increment (e.g., a plate, pin, or coupon). After successfully benchmarking against IAEA deterministic models, the simulation was used to test the sensitivity of DP to certain standard assumptions and selected input parameters. First, the equal defect assumption was tested; the results suggest significant complexity in the effectiveness of partial defect measurements. Next, the authors explored the sensitivity of DP to the assumed RSD of attribute tests. Then, the authors compared non-normal models for instrument performance (e.g., logistic, step, or arbitrary functions) to the typical results from a normal distribution (characterized by RSD). This last comparison was supplemented with experimentally derived performance data for an HM-5 gamma spectrometer. The HM-5 was used to make enrichment measurements on both LEU and HEU MTR fuel elements as plates were removed, and the results fit with logistic and step curves and applied in the simulation. These stochastic DP results were compared to DP estimates from a deterministic model assuming a normal curve and typical RSD, yielding insights that could improve effectiveness in the field. These early results illustrate the potential of stochastic models to better understand achieved DP and to improve safeguards effectiveness.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

Development and validation of a software for simulating γ-γ coincidence emission and detection probabilities

Gamma-gamma coincidence spectrometers have the potential to significantly enhance detection sensitivity for ultra-trace radionuclide measurements. The implementation of these spectrometers, however, is limited by the complexity of acquisition hardware, data processing and quantification. This work reports development of a novel radionuclide quantification software for γ-γ coincidence measurements. For any radionuclide, the software parses the Evaluated Nuclear Structure Data File (ENSDF) database, recursively simulating all possible γ-γ coincidence signatures and their respective emission and detection probabilities. Implemented using Python programming language, the software employs several strategies to boost overall computational performance. Since coincidence-based spectrometers are of notable interest in monitoring compliance for the Comprehensive Nuclear-Test-Ban Treaty (CTBT), the software’s execution was tested for 84 CTBT-relevant radionuclides. To date, the software has been experimentally validated for 15 radionuclides using the Advanced Radionuclide Gamma spectrOmeter (ARGO) at Pacific Northwest National Laboratory, USA (PNNL). Notably, the software can be operated in convergence mode, whereby coincidence detection efficiency’s convergence behavior can help avoid unreliable radionuclide activity estimates. With growing number of coincidence spectrometers worldwide, this paper aims to assist the radiation metrology community in developing similar software for their system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simple and Scalable Streaming: The GRETA Data Pipeline

The Gamma Ray Energy Tracking Array (GRETA) is a state of the art gamma-ray spectrometer being built at Lawrence Berkeley National Laboratory to be first sited at the Facility for Rare Isotope Beams (FRIB) at Michigan State University. A key design requirement for the spectrometer is to perform gamma-ray tracking in near real time. To meet this requirement we have used an inline, streaming approach to signal processing in the GRETA data acquisition system, using a GPU-equipped computing cluster. The data stream will reach 480 thousand events per second at an aggregate data rate of 4 gigabytes per second at full design capacity. We have been able to simplify the architecture of the streaming system greatly by interfacing the FPGA-based detector electronics with the computing cluster using standard network technology. A set of highperformance software components to implement queuing, flow control, event processing and event building have been developed, all in a streaming environment which matches detector performance. Prototypes of all high-performance components have been completed and meet design specifications.

Cromaz, Mario↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part II - Autonomous Navigation

Nuclear sites across the Unites States and other nations in the world, are prone to extreme radiation effects. To understand the radiation hazards, plan the cleanup efforts; and to meet the quality standards and guidelines, it is important to accurately characterize any nuclear facility. One of the current methods in characterizing facilities is the use of advanced autonomous systems. These are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. Conventional methods of taking radiation measurements by hand within or around the containment areas, and analyzing the collected data to obtain the result are: Ineffective, Puts scientists at risk of Radiation, Not cost-effective. The platform uses the Robotic Operating Systems (ROS) to integrate multiple sensors seamlessly. It can operate near real time by using a distributed processing system to handle large amounts of data: Surrounding cameras, A multi-channel 3D Lidar, Manipulator arm, High-performance gamma-ray spectrometer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗