Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Comprehensive Two-Dimensional Gas Chromatography to the Explore the Geochemistry of the Santa Barbara Oil Seeps

The development of comprehensive two-dimensional gas chromatography (GC x GC) has expanded the analytical window for studying complex mixtures like oil. Compared to traditional gas chromatography, this technology separates and resolves at least an order of magnitude more compounds, has a much larger signal to noise ratio, and sorts compounds based on their chemical class; hence, providing highly refined inventories of petroleum hydrocarbons in geochemical samples that was previously unattainable. In addition to the increased resolution afforded by GC x GC, the resulting chromatograms have been used to estimate the liquid vapor pressures, aqueous solubilities, octanol-water partition coefficients, and vaporization enthalpies of petroleum hydrocarbons. With these relationships, powerful and incisive analyses of phase-transfer processes affecting petroleum hydrocarbon mixtures in the environment are available. For example, GC x GC retention data has been used to quantitatively deconvolve the effects of phase transfer processes such as water washing and evaporation. In short, the positive attributes of GC x GC-analysis have led to a methodology that has revolutionized the analysis of petroleum hydrocarbons. Overall, this research has opened numerous fields of study on the biogeochemical "genetics" (referred to as petroleomics) of petroleum samples in both subsurface and surface environments. Furthermore, these new findings have already been applied to the behavior of oil at other seeps as well, for petroleum exploration and oil spill studies.

02 PETROLEUM↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Physicochemical Gas–Solid Sorption Properties of Geologic Materials Using Inverse Gas Chromatography

The goal of this study was to determine the physicochemical properties of a variety of geologic materials using inverse gas chromatography (IGC) by varying probe gas selection, temperature, carrier gas flow rate, and humidity. This is accomplished by measuring the level of interaction between the materials of interest and known probe gases. Identifying a material’s physicochemical characteristics can help provide a better understanding of the transport of gaseous compounds in different geologic materials or between different geological layers under various conditions. Our research in this study focused on measuring the enthalpy (heat) of adsorption, Henry’s constant, and diffusion coefficients of a suite of geologic materials, including two soil types (sandy clay-loam and loam), quartz sand, salt, and bentonite clay, with various particle sizes. The reproducibility of IGC measurements for geologic materials, which are inherently heterogeneous, was also assessed in comparison to the reproducibility for more homogeneous synthetic materials. This involved determining the variability of physicochemical measurements obtained from different IGC approaches, instruments, and researchers. For the investigated IGC-determined parameters, the need for standardization became apparent, including the need for application-relevant reference materials. The inherent physical and chemical heterogeneities of soil and many geologic materials can make the prediction of sorption properties difficult. Characterizing the properties of individual organic and inorganic components can help elucidate the primary factors influencing sorption interactions in more complex mixtures. This research examined the capabilities and potential challenges of characterizing the gas sorption properties of geologic materials using IGC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tile-Based Fisher-Ratio Software for Improved Feature Selection Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry Data

Two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a highly capable instrumental platform that produces complex and information-rich multi-dimensional chemical data. The complex data can be overwhelming, especially when many samples (of various sample classes) are analyzed with multiple injections for each sample. Thus, the data must be analyzed in such a way to extract the most meaningful information. The pixel-based and peak table-based algorithmic use of Fisher ratios has been used successfully in the past to reduce the multi-dimensional data down to those chemical compounds that are changing between classes relative to those that are not (i.e., chemical feature selection). We report on the initial development of a computationally fast novel tile-based Fisher-ratio software that addresses challenges due to 2D retention time misalignment without explicitly aligning the data, which is a problem for both pixel-based and peak table- based methods. Concurrently, the tile-based Fisher-ratio software maximizes the sensitivity contrast of true positives against a background of potential false positives and noise. To study this software, eight compounds, plus one internal standard, were spiked into diesel at various concentrations. The tile-based F-ratio software was able to discover all spiked analytes, within the complex diesel sample matrix with thousands of potential false positives, in each possible concentration comparison, even at the lowest absolute spiked analyte concentration ratio of 1.06.

chemometrics↗

Investigating Solvent Purity Utilizing Comprehensive Gas Chromatography: A Study of Acetones

Broad spectrum chemical analysis of trace level components is a continuing challenge for any analytical chemist. This challenge is further confounded when chemical impurities may be present in common organic solvents or when chemical artifacts may be formed, produced and introduced during an analytical procedure. Minimizing and understanding these chemical artifacts, is critical for trace level detection and is crucial for unambiguous analytical results. Comprehensive gas chromatography is an excellent analytical tool to help address these complex mixture challenges. This work examines the impurities present in various acetone sources utilizing comprehensive gas chromatography. This work highlights the extreme variability possible in solvent sources and hence the importance of understanding the impurities that may confound an analytical method or result.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an automated high-temperature valveless injection system for online gas chromatography

A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.

Kreisberg, N. M.↗

Correlation of rocket propulsion fuel properties with chemical composition using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry followed by partial least squares regression analysis

There is an increased need to more fully assess and control the composition of kerosene based rocket propulsion fuels, namely RP-1 and RP-2. In particular, it is crucial to be able to make better quantitative connections between the following three attributes: (a) fuel performance, (b) fuel properties (flash point, density, kinematic viscosity, net heat of combustion, hydrogen content, etc) and (c) the chemical composition of a given fuel (i.e., specific chemical compounds and compound classes present as a result of feedstock blending and processing). Indeed, recent efforts in predicting fuel performance through modeling put greater emphasis on detailed and accurate fuel properties and fuel compositional information. In this regard, advanced distillation curve (ADC) metrology provides improved data relative to classical boiling point and volatility curve techniques. Using ADC metrology, data obtained from RP-1 and RP-2 fuels provides compositional variation information that is directly relevant to predictive modeling of fuel performance. Often, in such studies, one-dimensional gas chromatography (GC) combined with mass spectrometry (MS) is typically employed to provide chemical composition information. Building on approaches using GC-MS, but to glean substantially more chemical composition information from these complex fuels, we have recently studied the use of comprehensive two dimensional gas chromatography combined with time-of-flight mass spectrometry (GC × GC - TOFMS) to provide chemical composition data that is significantly richer than that provided by GC-MS methods. In this report, by applying multivariate data analysis techniques, referred to as chemometrics, we are able to readily model (correlate) the chemical compositional information from RP-1 and RP-2 fuels provided using GC × GC - TOFMS, to the fuel property information such as that provided by the ADC method and other specification properties. We anticipate that this new chemical analysis strategy will have broad implications for the development of high fidelity composition-property models, leading to an optimized approach to fuel formulation and specification for advanced engine cycles.

fuel↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-targeted discovery-based analysis for gas chromatography with mass spectrometry: A comparison of peak table, tile, and pixel-based Fisher ratio analysis

The ability to discover minute differences between samples or sample classes for gas chromatography coupled to mass spectrometry (GC-MS) can be a challenging endeavor, especially when those differences are not a priori . Fisher ratio (F-ratio) analysis is an apt technique to probe the differences between GC-MS chromatograms. F-ratio analysis is a supervised, non-targeted, discovery-based method that compares two different samples (or sample classes) to reduce the GC-MS dataset into a hit list composed of class distinguishing compounds. Three different F-ratio techniques, peak table, tile, and pixel-based were used to “discover” nine non-native analytes that were spiked into gasoline at four different nominal concentrations of 250, 85, 25, 5 parts-per-million (ppm). For the tile and pixel-based F-ratio calculations, a novel methodology is introduced to improve the sensitivity of the F-ratio calculations while reducing false positives. Furthermore, we use a combinatorial technique using null class comparisons, termed null distribution analysis, to determine a statistical F-ratio cutoff for analysis of the hit lists. The pixel-based algorithm was the most sensitive method and was able to “discover” all nine spiked analytes at a nominal concentration of 250 ppm albeit with one false positive interspersed towards the bottom of the hit list. The pixel-based software was also able to “discover” more of the spiked analytes at the lower concentrations with seven of the spiked analytes “discovered” at 85 ppm, four of the spiked analytes “discovered” at 25 ppm, and one analyte “discovered” at 5 ppm.

47 OTHER INSTRUMENTATION↗

Understanding Biomass and Polymer Feedstock Variability Through Analytical Pyrolysis and Two Dimensional Gas Chromatography and Mass Spectrometry

Moving toward a circular carbon economy requires enabling reuse of carbon-based macromolecules like those in biomass and polymers. Meeting this goal requires increased upcycling of waste products into higher value products. For biomass waste such as corn stover, pine needles, or bark, one approach is using pyrolysis to convert these feedstocks into bio-oil that can be used for liquid fuel or transformed into other hydrocarbon based products, like bio-polymers. Waste plastics can be upcycled or recycled into new products, or alternatively converted into bio-oil by pyrolysis. Macromolecules from biomass and polymers are challenging to convert into liquid fuel or chemical feedstocks, due to large and sometimes heterogeneous networks of polymeric bonds. We work with the Idaho National Laboratory’s Biomass Feedstock National User Facility and Department of Energy’s Feedstock Conversion Interface Consortium to develop a molecular understanding of biomass variability that occurs naturally and as a result of storage or preprocessing techniques applied to feedstocks, to understand chemical reactions occurring during pyrolysis and other biomass or polymer conversion techniques. Using two dimensional gas chromatography mass spectrometry coupled to analytical pyrolysis provides insight into the molecular changes that occur during the pyrolysis event, and these insights can extend to bench or pilot scale pyrolysis conversions. Understanding pyrolysis of biomass and polymers at a molecular level contributes to development of new tools to predict and manipulate the optimum conditions and identify the best storage, preprocessing, and conversion techniques to maximize output of specific high-value chemical species in the conversion to fuels, or to characterize feedstocks for blending before pyrolysis. Identification and understanding of the molecular level changes resulting from novel preprocessing techniques that can be used to control and manipulate the chemical output of bench or pilot scale pyrolysis is another focus of investigation, including the use of gamma irradiation, acid, or enzyme pre-treatments. We also focus on the impacts of storage conditions and techniques, which can affect moisture levels, degradation, and impacts from naturally occurring microbes in the environment.

09 BIOMASS FUELS↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Auto-deconvolution and molecular networking of gas chromatography–mass spectrometry data

We engineered a machine learning approach, MSHub, to enable auto-deconvolution of gas chromatography–mass spectrometry (GC–MS) data. We then designed workflows to enable the community to store, process, share, annotate, compare and perform molecular networking of GC–MS data within the Global Natural Product Social (GNPS) Molecular Networking analysis platform. MSHub/GNPS performs auto-deconvolution of compound fragmentation patterns via unsupervised non-negative matrix factorization and quantifies the reproducibility of fragmentation patterns across samples.

47 OTHER INSTRUMENTATION↗

Rapid and sensitive gas chromatography ion-trap mass spectrometry method for the determination of tobacco specific N-nitrosamines in secondhand smoke

Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs in both the gas- and particle-phase of secondhand smoke (SHS) using gas chromatography and ion-trap tandem mass spectrometry,. A smoking machine in an 18-m3 room-sized chamber generated relevant concentrations of SHS that were actively sampled on Teflon coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid-liquid extraction protocol using methanol as solvent was successfully applied to both filters with high recoveries ranging from 85 to 115percent. Tandem MS parameters were optimized to obtain the best sensitivity in terms of signal to-noise ratio (S/N) for the target compounds. For each TSNA, the major fragmentation pathways as well as ion structures were elucidated and compared with previously published data. The method showed excellent performances with a linear dynamic range between 2 and 1000 ng mL-1, low detection limits (S/N> 3) of 30-300 pg.ml-1 and precision with experimental errors below 10percent for all compounds. Moreover, no interfering peaks were observed indicating a high selectivity of MS/MS without the need for a sample clean up step. The sampling and analysis method provides a sensitive and accurate tool to detect and quantify traces of TSNA in SHS polluted indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying lithium loss in amorphous silicon thin-film anodes via titration-gas chromatography

Silicon with a high theoretical capacity (3,579 mAh/g) is a promising anode candidate for lithium-ion batteries. However, commercialization is still impeded by low Coulombic efficiency, caused by solid electrolyte interphase (SEI) formation and trapped lithium (Li)-silicon (Si) alloy during repeated volume change. Quantifying capacity losses from each factor is crucial to formulate rational design strategies for further improvement. In this work, titration-gas chromatography and cryogenic transmission electron microscopy are applied to characterize the evolution of trapped Li-Si alloy and SEI growth in a silicon thin-film anode. It is found that continuous growth of the SEI is the dominant factor for lithium inventory loss during cycling, with only a marginal increase in trapped Li-Si alloy. This study offers a quantitative approach to differentiate Li in the SEI from trapped Li in Li-Si alloy through a silicon thin-film anode, providing unique insights into identifying critical bottlenecks for developing Si anodes.

25 ENERGY STORAGE↗

Activity Coefficients at Infinite Dilution of Organic Compounds in Trihexyl(tetradecyl)phophonium Bis(trifluoromethylsulfonyl)imide Using Inverse Gas Chromatography

Activity coefficients at infinite dilution of organic compounds in the ionic liquid (IL) trihexyl(tetradecyl) phosphonium bis(trifluoromethylsulfonyl)imide were determined using inverse gas chromatography at three temperatures, T ) (302.45, 322.35, and 342.45) K. Linear free energy relationship (LFER) correlations have been obtained for describing the gas-to-IL and water-to-IL partition coefficients.

Revelli, Anne-Laure↗

gcxgclab: Two Dimensional Gas Chromatography Preprocessing and Analysis

The goal of gcxgclab is to provide a comprehensive program for preprocessing and analysis of two dimensional gas chromatography data. It is equipped with functions for baseline correction, smoothing, peak identification, peak alignment, identification of EICs, Mass Spectra, targeted analysis, compound identification with NIST and non-targeted analysis, plus plotting and data visualization.

GAMBLE, STEPHANIE↗