DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating Safeguards Applications of DRiFT Gas Detector Capabilities [Slides]

DRiFT, a Detector Response Function Toolkit, post-processes MCNP output to model detector response. Three primary components: scintillator (focus of FY 21 TED work), gas detectors (focus of this FY), and semiconductor detectors. Capability to model scintillator detectors has previously been demonstrated.

47 OTHER INSTRUMENTATION↗

The HERO Program: High-Energy Replicated Optics for a Hard-X-Ray Balloon Payload

We are developing high-energy replicated optics for a balloon-borne hard-x-ray telescope. When completed, the telescope will have around 150 square cm of effective collecting area up to 65 keV, and an angular resolution of around 30 arc seconds, half power diameter. When used in conjunction with an array of focal plane imaging detectors, for which Gas Scintillation Proportional Counters are under development, the payload will provide unprecedented sensitivity for pointed observations in the hard-x-ray band. We will present an overview of the High Energy Replicated Optics (HERO) program together with test data from the first mirror units. The overall sensitivity of the full payload, when flown on long- and ultra-long-duration balloon flights, will be compared with past and planned satellite-borne hard-x-ray missions.

Ramsey, B. D.↗

Astro-D Prelaunch Mission Operation Report (MOR)

The Prelaunch Mission Operation Report for the Astro-D mission is enclosed for your information. Astro-D is a Japanese-led program involving the United States as a participating partner. The Japanese Institute of Space and Astronautical Science (ISAS) provides overall program management, the launch vehicle, the spacecraft, and two Gas Scintillation Imaging System detectors. NASA is providing four nested, thin-foil, grazing-incidence telescope mirrors and two X-ray charged-coupled device solid-state detectors. NASA also provides telemetry tracking support using Deep Space Network ground stations. In return for its scientific instrument contribution, the U.S. will receive 15 percent of the observing time and will share an additional 25 percent for collaborative U.S./Japan scientific investigations. Launch is scheduled for mid- February 1993 from the ISAS launch center near Kagoshima in southern Japan. This MOR: (a) describes the NASA objectives for the Astro-D mission; (b) provides brief descriptions of the spacecraft and its scientific instruments; (c) provides a chronology of launch and deployment; and (d) describes the ground operation elements that support the mission. .

Source record↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗

HPGS - A Sensitive Dark Matter Detector Using High Pressure Xe Gas at Room Temperature

We propose a dark matter detector based on scintillation in Xe gas at 5-10 bar pressure. Scintillation pulses are a factor 10 longer for alpha pulses than gamma pulses, and measurements in progress using neutron scattering indicate that the same difference applies to nuclear recoils, giving a 1E-6 rejection factor for electron recoil background. Light collection and background calculations indicate that dark matter sensitivity levels 1e-9 pb to 1E-10 pb would be achievable. Room temperature operation would enable Xe gas experiments >1 ton to be built at lower cost than current designs using liquid noble gases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Science Symposium, 21st, Scintillation and Semiconductor Counter Symposium, 14th, and Nuclear Power Systems Symposium, 6th, Washington, D.C., December 11-13, 1974, Proceedings

Papers are presented dealing with latest advances in the design of scintillation counters, semiconductor radiation detectors, gas and position sensitive radiation detectors, and the application of these detectors in biomedicine, satellite instrumentation, and environmental and reactor instrumentation. Some of the topics covered include entopistic scintillators, neutron spectrometry by diamond detector for nuclear radiation, the spherical drift chamber for X-ray imaging applications, CdTe detectors in radioimmunoassay analysis, CAMAC and NIM systems in the space program, a closed loop threshold calibrator for pulse height discriminators, an oriented graphite X-ray diffraction telescope, design of a continuous digital-output environmental radon monitor, and the optimization of nanosecond fission ion chambers for reactor physics. Individual items are announced in this issue.

Source record↗

Apparatus to study crystal channeling and volume reflection phenomena at the SPS H8 beamline

A high performance apparatus has been designed and built by the H8-RD22 collaboration for the study of channeling and volume reflection phenomena in the interaction of 400 GeV/c protons with bent silicon crystals, during the 2006 data taking in the external beamline H8 of the CERN SPS. High-quality silicon short crystals were bent by either anticlastic or quasimosaic effects. Alignment with the highly parallel (8 {mu}rad divergence) proton beam was guaranteed through a submicroradian goniometric system equipped with both rotational and translational stages. Particle tracking was possible by a series of silicon microstrip detectors with high-resolution and a parallel plate gas chamber, triggered by various scintillating detectors located along the beamline. Experimental observation of volume reflection with 400 GeV/c protons proved true with a deflection angle of (10.4{+-}0.5) {mu}rad with respect to the unperturbed beam, with a silicon crystal whose (111) planes were parallel to the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Quality Objective Considerations for Residual Alpha Surface Radioactivity Measurements at Remediation Sites - 16522

Surveys for residual alpha surface radioactivity on materials, equipment, and other non-porous surfaces are most-commonly performed using the traditional 'best available' equipment. The best available equipment for measuring alpha surface radioactivity includes portable gas-flow proportional or scintillation detectors with active surface areas typically ranging from 50 to 800 square centimeters (cm{sup 2}). The measurement equipment is offered by numerous service providers and instrument vendors applying basic detection principles that date back to the early-Atomic Age. The detector face is held as close to the surface as possible and scanned at a typical rate of 2 to 5 centimeters per second (cm/s). Any audible or visual indication of elevated alpha activity would result in a more careful assessment of the possible 'hot spot'. Modern surface contamination surveys continue to employ these best available technologies while endeavoring to achieve ever more restrictive measurement quality objectives and screening or release criteria. This paper considers the possibly unforeseen consequences to sensitivity and precision as scanning speeds are reduced to meet constraining measurement quality objectives. Sensitivity calculations are conducted to demonstrate how application of real-world efficiencies and the most common survey approaches are inadequate to meet sensitivity objectives based on American National Standard N13.12-2013, Surface and Volume Radioactivity Standards for Clearance screening criteria. Alternate data collection and assessment methodologies are offered to enhance the defensibility of collected data with stakeholders. Limitations of available or applied alpha survey technologies should be considered when establishing survey programs at project sites where alpha-emitting radionuclides are expected to contribute to residual surface radioactivity. These include but are not limited to nuclear fuel-cycle sites, military/weapons/energy research and production facilities, and 19.-20. Century-era commercial/ industrial/research/medical facilities where radioactive materials were handled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Perovskite Semiconductors for the Detection of Special Nuclear Material

Special nuclear material detection using portable, highly efficient detectors is of paramount importance to national security and environmental monitoring. Current neutron detectors, including gas proportional counters and scintillators, are not suitable for discrete or portable monitoring due to size, weight, and power limitations. For example, 3 He gas proportional detectors have significant drawbacks, including long absorption lengths, high voltage requirements, and dependence on the availability of 3 He. The goal of this project is to synthesize a novel, boron-based perovskite semiconductor crystals to create a more efficient and more portable neutron detector. This innovative material will lead to a significant decrease in power and size requirements with higher operating temperatures than other traditional solid-state detectors. Directly incorporating 10 B eliminates the need for a conversion layer and leads to high neutron absorption coefficients. In this seedling project, we used inverse temperature crystallization with boron precursors to create CH 3 NH 3 PbI 3-x (BF 4 ) x . The crystals were analyzed with X-ray diffraction, but the results were inconclusive. Future work will focus on tailoring the solution growth and selecting appropriate solvents and precursors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Cosmic Ray Nuclei Experiment on the Spacelab-II mission

The Cosmic Ray Nuclei Experiment flown on the Spacelab-II mission was designed to measure the elemental composition of individual cosmic ray nuclei (Li to Ni) from 40 Gev/amu to several TeV/amu. The detector utilizes plastic scintillation counters for charge measurement, and gas Cerenkov and transition radiation detectors for energy measurements. The data analysis is in progress and results on the energy spectra are expected in the near future.

Grunsfeld, John Mace↗

Study of light backgrounds from relativistic electrons in air light-guides

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (Moller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the Moller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the proton $A_1$ and $A_2$ spin asymmetries. Probing Color Forces

The Spin Asymmetries of the Nucleon Experiment (SANE) measured the proton spin structure function $g_2$ in a range of Bjorken x, 0.3 < x < 0.8, where extraction of the twist-3 matrix element $d_2^p$ (an integral of $g_2$ weighted by $x^2$) is most sensitive. The data was taken from $Q^2$ equal to 2.5 $GeV^2$ up to 6.5 $GeV^2$. In this polarized electron scattering off a polarized hydrogen target experiment, two double spin asymmetries, A∥ and A⊥ were measured using the BETA (Big Electron Telescope Array) Detector. BETA consisted of a scintillator hodoscope, gas Cerenkov counter, lucite hodoscope and a large lead glass electromagnetic calorimeter. With a unique open geometry, a threshold gas Cerenkov detector allowed BETA to cleanly identify electrons for this inclusive experiment. A measurement of $d_2^p$ is compared to lattice QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗