Internal-film-cooling experiments with 2- and 4-inch smooth-surface tubes and gas temperatures to 2000 F
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Liquid/gas separator vents gas from tank of liquid that contains gas randomly distributed in bubbles. Centrifugal force separates liquid and gas, forcing liquid out of vortex tube through venturi tube. Gas vented through exhaust port. When liquid detected in vent tube, exhaust port closed, and liquid/gas mixture in vent tube drawn back into tank through venturi.
Numerical analysis of helium gas developing laminar tube flow and heat transfer
Laminar tube flow and heat transfer for He gas using Navier-Stokes, energy and continuity equations in finite difference form
This paper presents a report on the latest advances and technology in the design, construction, testing, and operation of high pressure gas bimetallic pipe systems and high pressure gas tube fittings facilitating greater alinement and manufacturing tolerances, and the supercleaning of high pressure gas systems under field conditions. The following specific topics are discussed: - Analysis of noncorrosive steels versus bimetallic, high strength steels - Analysis of various protective finishes versus bimetallic piping - Testing of high pressure systems - Pipe liner adhesion properties under varying operating conditions - Modified flared tube fittings taking into account pressure ranges, materials, costs involved in manufacture, various methods employed to permit sealing of the fitting while meeting cleanliness requirements - Cleaning requirements appertaining to high pressure gas systems and a discussion of investigations on the effects of velocity and temperature as related to various cleaning chemicals. The presentation concludes with a discussion on the possible applications of materials and methods in commercial industry.
The goals of our work on detached solidification have been to: Develop a complete understanding of all of the phenomena of detached solidification; Make it possible to achieve detached solidification reproducibly; Increase crystallographic perfection through detached solidification. Specifically, we aimed in this project to: Identify a system and develop methods that would allow viewing of the melt surface and convection in the melt during detached solidification in microgravity; Improve understanding of the origination and evolution of detachment through experiments and theoretical treatments; Achieve detachment on earth. The project resulted in 14 publications, 15 presentations, completion of 2 Ph.D. theses, and completion of 2 M.S. theses. Two additional papers are currently being reviewed for publication. Copies of most of the papers are attached as appendices. Among the accomplishments are: Achievement of detached solidification of InSb on earth and determination of the conditions favoring detachment on earth. Development of a new method for coating the interior of silica growth ampoules with transparent boron nitride, which yields the high contact angles for semiconductor melts that favor detachment. Development of a new coating for the interior of Pyrex ampoules yielding very high contact angles for water and molten organic compounds. Development of a material-balance model for steady detached solidification that provides greatly improved insight into the process, both in microgravity and on earth. Dimensionless parameters were found that clarify the role of operating conditions and physical properties. The reason for the occurrence of two steady states was clarified, along with their relative stability. Observation of periodic gas tubes during directional solidification of water and organic compounds. Gas bubbles did not propagate around the periphery to yield full detachment. Failure to obtain detachment is attributed to the ready plastic deformation of these materials, so that the frozen material continues to adhere to the ampoule wall during cooling.
Shock tube for gas dynamics studies
An analysis is made of the influence that radiation exchanges between elements on the inside surface of a tube have on the wall and gas temperature distributions for forced-convection flow. The wall heat generation has a chopped sine distribution with length along the tube, which is a distribution often encountered in nuclear-reactor channels. The flowing gas is assumed transparent to thermal radiation and hence does not participate directly in the radiative exchange process. Axial heat conduction is neglected in the gas and tube wall, and the convective-heat-transfer coefficient and fluid properties are assumed constant. Several numerical examples are given to illustrate the effects of eight independent parameters such as wall emissivity, Stanton number, and length-diameter ratio. In some instances the radiation exchanges reduced the peak wall temperature or caused a reduction in the exit gas temperature because of radiation losses from the tube end openings.
The figure depicts a device for measuring the electrical conductivity of a flowing liquid. Unlike prior such devices, this one does not trap gas bubbles entrained in the liquid. Usually, the electrical conductivity of a liquid is measured by use of two electrodes immersed in the liquid. A typical prior device based on this concept contains large cavities that can trap gas. Any gas present between or near the electrodes causes a significant offset in the conductivity reading and, if the gas becomes trapped, then the offset persists. Extensive tests on two-phase (liquid/ gas) flow have shown that in the case of liquid flowing along a section of tubing, gas entrained in the liquid is not trapped in the section as long as the inner wall of the section is smooth and continuous, and the section is the narrowest tubing section along the flow path. The design of the device is based on the foregoing observation: The electrodes and the insulators separating the electrodes constitute adjacent parts of the walls of a tube. The bore of the tube is machined to make the wall smooth and to provide a straight flow path from the inlet to the outlet. The diameter of the electrode/insulator tube assembly is less than the diameter of the inlet or outlet tubing. An outer shell contains the electrodes and insulators and constitutes a leak and pressure barrier. Any gas bubble flowing through this device causes only a momentary conductivity offset that is filtered out by software used to process the conductivity readings.
Disclosed herein are systems and methods related to use of hollow core photonic crystal fibers. A system includes a tube and a collimating lens configured in a first end of the tube, wherein a single mode fiber is coupled to a first end of the collimating lens. A second lens is supported by a structure at a second end of the tube, the second lens receiving a first signal from a second end of the collimating lens and outputting a second signal that is coupled into a first end of a hollow core photonic crystal fiber. A first gas tube is configured to introduce gas through the structure into a chamber and a sealant seals at least one of the collimating lens and the structure within the tube. An output signal is received at a detector that catches the entire beam to suppress multiple-mode beating noise.
A heat transfer analysis of a transparent gas flowing through a circular tube of finite thickness is presented. This study includes the effects of wall conduction, internal radiative exchange, and convective heat transfer. The natural mathematical formulation produces a nonlinear, integrodifferential equation governing the wall temperature and an ordinary differential equation describing the gas temperature. This investigation proposes to convert the original system of equations into an equivalent system of integral equations. The Green's function method permits the conversion of an integrodifferential equation into a pure integral equation. The proposed integral formulation and subsequent computational procedure are shown to be stable and accurate.
The properties of a constricted-tube gas flow levitator first developed by Berge et al. (1981) have been investigated experimentally in order to predict its behavior in a gravity-free environment and at elevated temperatures. The levitator consists of a constricted (quartz) tube fed at one end by a source of heated air or gas. A spherical sample is positioned by the air stream on the downstream side of the constriction, where it can be melted and resolidified without touching the tube. It is shown experimentally that the kinematic viscosity is the important fluid parameter for operation in thermal equilibrium at high temperatures. If air is heated from room temperature to 1200 C, the kinematic viscosity increases by a factor of 14. To maintain a given value of the Reynolds number, the flow rate would have to be increased by the same factor for a specific geometry of tube and sample. Thus, to maintain stable equilibrium, the flow rate should be increased as the air or other gas is heated. The other stability problem discussed is associated with changes in the shape of a cylindrical sample as it melts.
The Advanced Test Reactor (ATR) supports neutron irradiation of several types of experiments. One such experiment type is referred to as a gas leadout. Gas leadout experiments actively flow gas through the experiment which allows for active temperature control. It also allows for in-situ data of the experiment. For example, fission gas migration through a fuel sample can be monitored via activity of the sweep gas. Historically, ex-pile equipment and fission product monitors were housed in shielded ATR cubicles. Due to other facility updates, cubicle space is no longer available for gas leadout experiment equipment. To support continued operation of gas leadout experiments, ATR completed a safety basis update that supports a new housing for leadout equipment that may process potentially contaminated gas. In addition to the structure and associated equipment, technical safety requirements regarding handling and storage of experiments needed to be revised to support fueled gas leadout experiments and associated outage configurations. The safety basis update addressed the full lifecycle of these experiments, including experiment movement and interim storage, and credible abnormal events such as failures or leaks in contaminated gas tubing in occupied areas. This paper discusses the completed analyses performed to support the safety basis update associated with gas leadout experiments, including thermal-hydraulic evaluation, probabilistic analysis, and dose consequence analyses.
The science requirements for materials processing is to provide the desired PI requirements of thermal gradient, solid/liquid interface front velocity for a given processing temperature desired by the PI. Processing is performed by translating the furnace with the sample in a stationary position to minimize any disturbances to the solid/liquid interface front during steady state processing. Typical sample materials for this metals and alloys furnace are lead-tin alloys, lead-antimony alloys, and aluminum alloys. Samples must be safe to process and therefore typically are contained with hermetically sealed cartridge tubes (gas tight) with inner ceramic liners (liquid tight) to prevent contamination and/or reaction of the sample material with the cartridge tube.
A cavity heat pipe experiment has been designed to test the critical issues involved with incorporating thermal energy storage canisters into a heat pipe. The experiment is a replication of the operation of a heat receiver for a Brayton solar dynamic power cycle. The heat receiver is composed of a cylindrical receptor surface and an annular heat pipe with thermal energy storage canisters and gaseous working fluid heat exchanger tubes surrounding it. Hardware for the cavity heat pipe experiment will consist of a sector of the heat pipe, complete with gas tube and thermal energy storage canisters. Thermal cycling tests will be performed on the heat pipe sector to simulate the normal energy charge/discharge cycle of the receiver in a spacecraft application.
The effects of various gaseous atmospheric constituents on drop-tube solidified samples of elemental metals were examined from a microstructural standpoint. All specimens were prepared from the purest available elements, so effects of impurities should not account for the observed effects. The drop-tube gas has a definite effect on the sample microstructure. Most dramatically, the sample cooling rate is effected. Some samples receive sufficient cooling to solidify in free fall while others do not, splating at the end of the drop tube in the sample catcher. Gases are selectively absorbed into the sample. Upon solidification gas can become less soluble and as a result forms voids within the sample. The general oxidation/reduction characteristics of the gas also affect sample microstructures. In general, under the more favorable experimental conditions including reducing atmospheric conditions and superheatings, examination of sample microstructures indicates that nucleation has been suppressed. This is indicated by underlying uniform dendrite spacings throughout the sample and with a single dendrite orientation through most of the sample. The samples were annealed yielding a few large grains and single or bi-crystal samples were commonly formed. This was especially true of samples that were inadvertently greatly superheated. This is in contrast with results from a previous study in which surface oxides were stable and contained numerous sites of nucleation. The number of nucleation events depends upon the surface state of the specimen as determined by the atmosphere and is consistent with theoretical expectations based upon the thermodynamic stability of surface oxide films. Oxide-free specimens are characterized by shiny surfaces, with no observable features under the scanning electron microscope at 5000X.
The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.
We consider the problem of the development of steady states in one-dimensional Bose gas tubes that are weakly coupled to one another through a density-density interaction. We analyze this development through a Boltzmann collision integral approach. We argue that when the leading order of the collision integral, where single particle-hole excitations are created in individual gases, is dominant, the state of the gas evolves first to a non-thermal fixed point, i.e. a prethermalization plateau. This order is dominant when a pair of tubes are inequivalent with, say, different temperatures or different effective interaction parameters, \gamma γ . When both tubes are in the strongly interacting regime we additionally characterize this non-thermal prethermalization plateau by constructing the quasi-conserved quantities that control the existence of this plateau as well as the associated generalized Gibbs ensemble.