At least 37 records · Page 2

Leakage Through a Channel Formed by a Gasket, a Sealing Surface, and a Filament Trapped Between Them

Plumbing for the transport of liquid Hydrogen or liquid Oxygen at the Kennedy Space Center (KSC) is very critical. Every piece of hardware for handling such a hazardous cryogen is subject to testing prior to installation and use. Safe, realistic testing of all such hardware is prohibitively expensive, which leads, perforce, to expidients such as: (1) lead testing with non-flammable tracer fluids (e.g, liquid nitrogen) and (2) leak testing with room temperature tracer fluids (e.g. liquid helium). Such expedients undermine the realism of the tests. If however, one could apply rational fluid dynamics methods to derive a general analytical expression with which one could relate the throughput of gaseous Helium through a given leak channel to the throughput of liquid Hydrogen through the same channel, then one could recover much of the information that one would otherwise forfeit through these expedients. These facts lead to the following questions: (1) What would be an example of a generic flaw in a gasket?; and (2) How can one calculate the flow of fluid in it? The report addresses these questions. It considers a particular leak geometry, namely one formed by a gasket, a sealing surface, and a filament trapped between them (so that the cross section of the leak channel is a flat bottomed curvilinear triangle, two sides of which are circular arcs and which has cusps on all three corners).

Russell, John↗

Partial-Vacuum-Gasketed Electrochemical Corrosion Cell

An electrochemical cell for making corrosion measurements has been designed to prevent or reduce crevice corrosion, which is a common source of error in prior such cells. The present cell (see figure) includes an electrolyte reservoir with O-ring-edged opening at the bottom. In preparation for a test, the reservoir, while empty, is pressed down against a horizontal specimen surface to form an O-ring seal. A purge of air or other suitable gas is begun in the reservoir, and the pressure in the reservoir is regulated to maintain a partial vacuum. While maintaining the purge and partial vacuum, and without opening the interior of the reservoir to the atmosphere, the electrolyte is pumped into the reservoir. The reservoir is then slowly lifted a short distance off the specimen. The level of the partial vacuum is chosen such that the differential pressure is just sufficient to keep the electrolyte from flowing out of the reservoir through the small O-ring/specimen gap. Electrochemical measurements are then made. Because there is no gasket (and, hence, no crevice between the specimen and the gasket), crevice corrosion is unlikely to occur.

Bonifas, Andrew P.↗

Impact of Different Standard Type A7A Drum Closure-Ring Practices on Gasket Contraction and Bolt Closure Distance– 15621

The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 “Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactive material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum “suffers maximum damage.” Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured.

42 ENGINEERING↗

Impact of different standard type A7A drum closure-ring practices on gasket contraction and bolt closure distance - 15621

The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 'Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactive material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum 'suffers maximum damage.' Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Narrow Slot Gasket Grooves And Step Changes In Width

We provide corrections to the slot capacitance and inverse inductance per unit length for slot gasket groove geometries using an approximate conformal mapping approach. We also provide corrections for abrupt step changes in slot width along with boundary discontinuity conditions for implementation in the various slot models.

42 ENGINEERING↗

Composite gaskets are compatible with liquid oxygen, resist compression set

Gaskets fabricated by laminating fluorocarbon polymers with fiber glass cloth have a low compression set. Their flexibility is not subject to drastic changes at the temperature of liquid oxygen with which they are used. The fabrication process is controlled so that the fibers are not impregnated with the polymer.

Gosnell, R. B.↗

Combination spacer and gasket provides effective static seal

Closely machined steel ring having narrow sealing lands on both faces and a thin coating of a commercially available halocarbon polymer combines the functions of a spacer and static seal ring or gasket having a minimum of potential leak paths. The device is effective over a wide range of temperatures down to minus 423 deg F and at pressure up to 180 psig.

Jones, F. B.↗

Evaluation of elastomers as gasket materials in pneumatic and hydraulic systems

In the search for superior materials from which to make gaskets for pneumatic and hydraulic systems, promising materials were selected and tested. The testing was conducted in two phases. Those materials that passed the tests of Phase 1 were tested in Phase 2, and categorized in the order of preference.

Bright, C. W.↗

Structural evaluation of Marman V-band coupling and flange with conoseal gasket

Results are described of a development test program directed at evaluating the structural capabilities of the Marman V-band coupling and flange with conoseal gasket. The intended end use was for the 75K NERVA flight engine propellant lines. Of major importance in the structural evaluation was the ability to predict stresses throughout the assembly for a variety of loading conditions. Computer finite element analysis was used to predict these stresses but, for the subject configuration, large uncertainties were introduced in modeling the complex geometry and boundary conditions. The purpose of the structural tests was to obtain actual stresses and deflections for correlation with, and updating of the finite element model. Results of the incomplete test program are inconclusive with respect to determining suitability for use on the NERVA engine.

Oates, J. H.↗

Liquid-Oxygen-Compatible Cement for Gaskets

Fluorelastomer and metal bonded reliably by new procedure. To cure fluoroelastomer cement, metal plate/gasket assembly placed in vacuum bag evacuated to minimum vacuum of 27 inches (69 cm) of mercury. Vacuum maintained throughout heating process and until assembly returns to ambient room temperature. Used to seal gaskets and O-rings or used to splice layers of elastomer to form non-standard sized O-rings. Another possible use is to apply protective, liquid-oxygen-compatible coating to metal parts.

Elmore, N. L.↗

Pressure concentrations due to plastic deformation of thin films or gaskets between anvils

Plastic deformation of either a sample or a gasket between diamond anvils leads to large pressure concentrations, i.e., the maximum pressure can be many times the average pressure. This behavior is discussed using elementary plasticity theory for the case where the pressures are sufficiently low that the yield stress can be assumed not to vary with pressure. It is then shown that the pressure concentration factor can be even much larger when the yield stress of the sample at the highest pressure is much greater than the yield stress at the lowest pressure. This is illustrated with solid xenon where it is shown that the assumption that Nelson and Ruoff made about the pressure distribution in their xenon samples is incorrect. The pressure distribution is shown to be much steeper than assumed. Thus, the pressure they observed electrical conduction in xenon was above 1 Mbar.

Chan, K. S.↗