Search NASA⌕ Search

SEARCH · Search NASA

Results for “GEIGER COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Far-ultraviolet studies. II - Galactic-latitude dependence of the 1530 A interstellar radiation field

A 0.62-sq cm Geiger counter, sensitive between 1425 and 1640 A, was used to map the far-ultraviolet brightness of about half the sky, providing an experimental measurement of the far-ultraviolet interstellar radiation field. At 1530 A, the energy density is approximately 7.4 by 10 to the -17th power erg/cu cm per A. Comparison with integrations of star catalogs calibrated to the ultraviolet shows, as expected, that the bulk of the radiation comes directly from B- and A-type stars. The galactic-latitude dependence of the radiation is analyzed in an unsuccessful attempt to set limits on the absorbing and scattering properties of the interstellar grains in the far-ultraviolet. Excess radiation observed at the galactic pole is probably residual airglow from above the rocket altitude.

Henry, R. C.↗

X-Ray Diffraction Study of the Internal Structure of Supercooled Water

A Bragg X-ray spectrometer equipped with a volume-sensitive Geiger counter and Soller slits and employing filtered molybdenum Ka radiation was used to obtain a set of diffracted intensity curves as a Punction of angle for supercooled water. Diffracted intensity curves in the temperature region of 21 to -16 C were obtained. The minimum between the two main diffraction peaks deepened continuously with lowering temperature, indicating a gradual change in the internal structure of the water. No discontinuity in this trend was noted at the melting point. The internal structure of supercooled water was concluded to become progressively more ice-like as the temperature is lowered.

Dorsch, Robert G.↗

Instrumentation for X-ray Astronomy

Less than five decades ago, the first X-ray observations of the sky were made using simple devices such as film and geiger counters with crude collimators. These instruments were carried aloft by sounding rockets and made observations lasting only a few minutes at most. Today, orbiting observatories, utilizing high-resolution charged coupled devices (CCD's) at the focus of arc sec optics, have lifetimes measured in years. To maintain the pace of discovery in X-ray astronomy, detectors must continue to evolve into devices of ever increasing sensitivity and sophistication. Further progress depends upon a host of technologies: grazing incidence optics, proportional counters, semiconductors, calorimeters, etc. In this article we present a brief qualitative overview of these technologies and of the principles behind them, as well as some examples of how they are employed in scientific missions for X-ray observations at energies up to 100 keV.

Ramsey, Brian D.↗

Development of the cosmic ray techniques

It has been found that most advances of cosmic-ray physics have been directly related to the development of observational techniques. The history of observational techniques is discussed, taking into account ionization chambers, refinements applied to ionization chambers to make them suitable for an effective use in the study of cosmic radiation, the Wulf-type electrometer, the electrometer designed by Millikan and Neher, the Geiger-Mueller counter, the experiment of Bothe and Kolhoerster, the coincidence circuit, and a cosmic-ray 'telescope'. Attention is given to a magnetic lens for cosmic rays, a triangular arrangement of Geiger-Mueller counters used to demonstrate the production of a secondary radiation, a stereoscopic cloud-chamber photograph of showers, the cloud-chamber picture which provided the first evidence of the positive electron, and arrangements for studying photon components, mu-mesons, and air showers.

Rossi, B.↗

Development of cosmic ray techniques

It is pointed out that most advances of cosmic-ray physics have been directly related to the development of observational techniques. A review is presented of the history of the evolution of the techniques and equipment for the study of cosmic-ray physics, taking into account the new scientific advances accompanying each new development related to experimental technology. All of the early observations were performed by means of ionization chambers. These chambers had already been in use for a number of years, when they were first applied to the study of cosmic rays in the early years of this century. However, an application to the low-intensity cosmic radiation required special refinements. Attention is given to the design of suitable electrometers, the development of self-recording instruments, the 'tube counter', the development of the coincidence method, a cosmic-ray 'telescope', a magnetic lens for cosmic rays, an arrangement of Geiger-Mueller counters for the demonstration of secondary radiation, cloud chambers, scintillation counters, and air shower experiments.

Rossi, B.↗

Ionization chamber.

Ionization chamber for measuring interplanetary space radiation, using Geiger-Mueller counter as secondary detector

SPACE RADIATION↗

The Low Altitude Plasma Instrument /LAPI/

The Low Altitude Plasma Instrument on the Dynamics Explorer-B spacecraft provides high resolution velocity space measurements of positive ions and electrons from 5 eV to 32 keV and a monitor of electrons with energies above 35 keV. It consists of an array of 15 parabolic electrostatic analyzers spanning 180 deg in angle and two Geiger-Mueller counters mounted on a one-degree of freedom scan platform. The platform is controlled by a magnetometer that allows placement of the array to selected angles with respect to the magnetic field. Each parabolic analyzer simultaneously measures electrons and positive ions. The temporal resolution and energy range of the measurements and the detector complement to be sampled are programmable by ground command

Winningham, J. D.↗

A radionuclide counting technique for measuring wind velocity

A technique for measuring wind velocities of meteorological interest is described. It is based on inverse-square-law variation of the counting rates as the radioactive source-to-counter distance is changed by wind drag on the source ball. Results of a feasibility study using a weak bismuth 207 radiation source and three Geiger-Muller radiation counters are reported. The use of the technique is not restricted to Martian or Mars-like environments. A description of the apparatus, typical results, and frequency response characteristics are included. A discussion of a double-pendulum arrangement is presented. Measurements reported herein indicate that the proposed technique may be suitable for measuring wind speeds up to 100 m/sec, which are either steady or whose rates of fluctuation are less than 1 kHz.

Singh, J. J.↗

The spectrum of cosmic electron with energies between 6 and 100 GeV

This experiment was carried out during three balloon flights which provided a total exposure of 3500 + or - 60 sq m sec sterad at an average depth of 4.8 g/sq cm The detector, in which the development of cascade showers in a 33.7 rl absorber was sampled by 10 scintillation counters and 216 Geiger-Muller tubes, was calibrated at the Cornell Electron Synchrotron, the separation of cosmic electrons from the nuclear background was confirmed by extensive analysis of data from the flights, from the calibration and from ground level exposure. The spectral intensity of primary cosmic ray electrons were found in particles/sq m sec sterad GeV. Similarly, the ground level spectrum of secondary cosmic ray electrons was also found. The steepness of the spectrum of cosmic electrons relative to that of nuclei implies one of the following conclusions: either the injection spectrum of electrons is steeper than that of nuclei, or the electron spectrum has been steepened by Compton/synchrotron losses in the energy range covered by the experiment.

Meegan, C. A.↗

Hodoscope Measurements of the Spectrum of Cosmic Electrons Between 10 Gev and 100 Gev

In an attempt to reduce divergences among independent measurements of the electron spectrum above 10 GeV, electrons were detected with the aid of a large hodoscope which incorporates 8 trays of Geiger tubes and 10 scintillation counters into a calorimeter containing 33 radiation lengths of lead. This instrument was thoroughly calibrated up to 9 GeV with an electron synchrotron and was flown twice at a depth of 5 g/sq cm for a total of 30 hours at ceiling. Electron showers at 10 GeV are completely contained within the calorimeter where their ionization is sampled twelve times, and where hodoscope trays provide information on the geometrical distribution of shower particles. Electrons appeared in a histogram of number of events vs. a X2 measure of goodness of fit to electron shower curves as a clearly resolved peak standing well above the nuclear background. The initial ionization and the lateral spread of shower particles are consistent with those of calibration electrons. In contrast, the behavior of the nuclear continuum associated with minimum ionizing incident particles is different from that of calibration electrons but similar to that of nuclear events associated with incident helium nuclei. The differential electron spectrum from 10 to 100 GeV was obtained.

Meegan, C. A.↗