Search NASA⌕ Search

SEARCH · Search NASA

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design, Construction, and Installation of In-Glovebox Pumped Actinide Molten Salt Loops

This report summarizes the work conducted in FY25 to construct and install pumped actinide-bearing molten salt loopsin a radiological glovebox. The establishment of such a capability will provide a platform in which technologies developed for Gen. IV molten salt reactors may be tested under relevant operating conditions. A review of convective molten salt systems is provided to frame Argonne’s pumped actinide loop relative to contemporary and historical systems. Moreover, the infrastructure needed to operate the system is detailed to provide additional context as to design metrics of the loops and supporting equipment. The pumps’ performance in water testing is outlined and used to inform operational activities planned in FY26. Finally, electrochemical experiments investigating fundamental reaction mechanisms governing reactive oxygen species that promote corrosion of molten salt media is also reported. In total, these combined loop installation and sensor development tasks will serve to aid in the future commercial deployment of molten salt reactors in the U.S.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lessons Learned From Ventilation and Glovebox Flooding Via Overfilling of the Wet Vacuum System in a Plutonium Facility

In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Specimen Size Artifacts Associated with a Glovebox Deployable Laser Flash Diffusivity Measurement System

To accelerate nuclear fuel qualification and deployment efforts, Oak Ridge National Laboratory has led the world in developing vehicles for accelerating burnup accumulation in nuclear fuel by testing miniature samples in the High Flux Isotope Reactor. However, a challenge remains to establish parity between post irradiation characterization methods for miniature fuel specimens in comparison to conventional fuel elements. This work aims to identify artifacts associated with the thermal analysis of miniature disk specimens in comparison to samples of standardized dimensions through a combination of experimental and computational tools. Using a newly procured Netzsch 427 laser flash diffusivity system, preliminary data on mild steel specimens were collected, and finite element techniques were used to model heat transfer using 1D conditions to assess issues associated with pulse width and data collection frequency effects. These preliminary investigations found that significant variability in measured thermal diffusivity exist within datasets. These variations are not necessarily attributed to limitations with respect to data collection rate; nor are they associated with limitations on pulse width. Instead, these artifacts may be a result of limitations in detector intensity. Future work aims to design a focusing lens to better measure the smaller surface area of miniature specimens analyzed using the laser flash analysis system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-glovebox container

A container having two different closing mechanism designs including an upright strike-less latch design and a Buttress thread design.

Oka, Jude M.↗

Evaluation Of Elbow Exoskeleton in Glovebox Operations To Minimize Injuries – 25704

In nuclear facilities across the DOE, ergonomic injuries pose a significant occupational hazard for GB workers. Recent studies at Los Alamos National Laboratory (LANL) have revealed concerning trends in worker health, with approximately 50% of GB workers reporting musculoskeletal symptoms after 25 years of service [1]. The current GB design, largely unchanged since the 1960s, presents several ergonomic challenges including inappropriate finger lengths, nonexistent joint angles, and incorrect thumb placement. These design flaws directly contribute to conditions such as lateral epicondylitis (tennis elbow) and De Quervain's tenosynovitis which causes pain and inflammation in the tendons at the base of the thumb. These are examples of conditions caused by workers performing repetitive precision tasks [2].

Ramon, Rodrigo N. [Savannah River National Laborat↗

Design and Development of a Robotic Exoskeleton Device for use in Glove Boxes - 20374

Glovebox operators in nuclear facilities often operate under radioactive environment and typically perform monotonous, dull and repetitive work. This can result in muscle fatigue leading to increased levels of accidents. Current research work aims in assisting the glovebox operators by designing a novel upper limb exoskeleton device to reduce injuries and increase worker efficiency. Almost none of the commercially available hand and upper body exoskeletons are directly suitable for use in gloveboxes. This explains the novelty of the present work in developing a wearable powered robotic exoskeleton device. The device consists of electronics, motors and spring systems mounted on adjustable plates and is supported by a stationary frame behind the worker. The device is intended to be portable and adjustable according to the operator height. The elbow has a flexion movement assisted with motor control by way of a Bowden cable system. The system is floated on a spring and pulley combination that allows for extra safety and smoothness of operation. The end points are fixed near the pivot points to help minimize unwanted movement/torque. The extension movement of the upper and lower arm are assisted by gravity and a counter spring. The shoulder and upper arm movement are held in a neutral position with a spring system for counter balance allowing small movements within the glovebox. This initial concept considers only the vertical movement of the arm. The abduction and adduction movement will not be assisted or impeded by the over shoulder plate or at the forearm plate allowing for full range of motion. Several glovebox aspects such as the level of task assistance, ergonomic design, minimum hindrance in dexterity/operator movements and tear resistance for hazardous safety reasons will be considered in the design of the exoskeleton. Computer models will be simulated to test the load levels and stress conditions on the exoskeleton to enhance the designs. The exoskeleton focusses on major muscular involvement reduction through weight offset and active assistance with minimal parts and hence the device is derived with several joint links and contains both passive and active joints. The paper details the various stages in the design development and prototype testing of the exoskeleton device. Upon successful prototype device development, human testing will be conducted in a replica of the SRS-235F hot cell facility constructed at FIU-ARC. The final stage of the project will be potential testing/deployment of the exoskeleton device in one of the glovebox facilities in Savannah River Nuclear Waste site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Custom Equipment Development for Processing of Surplus Plutonium

The Strategic Laboratory Assessment (SLA), a collaborative team of SRNL and ORNL personnel, has been established to advance the objectives of the Surplus Plutonium Disposition (SPD) Project, by identifying and developing technologies to accelerate disposition, reduce life cycle costs, minimize worker radiation exposure, improve worker safety, and minimize Surplus Plutonium Disposition Program risks. [1] The SLA team has identified can cutting and plutonium (Pu) oxide size reduction as two glovebox processes where technology enhancements would be valuable. The DOESTD-3013 package currently in use for Pu downblending requires cutting two nested cans before the inner convenience can that holds the Pu oxide may be accessed for further processing. A rotary tubing-style cutter is used for opening the 3013 packages within the glovebox. Collet changeouts are required between cutting of the outer and inner cans. The SLA team is currently developing and testing an adjustable-clamp can cutter design that eliminates collet changeouts and allows cutting of the outer and inner can at the same time, resulting in significant reduction of radiological dose and process time, as well as improved ergonomics. To meet the Pu oxide particle size requirement, size reduction of Pu oxide agglomerations must be performed within the process gloveboxes. The SLA team has identified jaw crushing technology as an alternative to the currently employed rotary mill. Jaw crusher advantages include reduced dust within the glovebox, increased batch sizes, and easier integration with other glovebox processes due to the flow-through nature of jaw crushing. Commercially manufactured jaw crushers are either too large and/or too heavy for implementation in the SPD gloveboxes, so the SLA team is developing and testing a custom jaw crusher to meet the needs of the SPD Project.

Krementz, Daniel [Savannah River National Laborato↗

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗