Search NASASearch

SEARCH · Search NASA

Results for “GYROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hardware platforms for MEMS gyroscope tuning based on evolutionary computation using open-loop and closed -loop frequency response

We propose a tuning method for MEMS gyroscopes based on evolutionary computation to efficiently increase the sensitivity of MEMS gyroscopes through tuning. The tuning method was tested for the second generation JPL/Boeing Post-resonator MEMS gyroscope using the measurement of the frequency response of the MEMS device in open-loop operation. We also report on the development of a hardware platform for integrated tuning and closed loop operation of MEMS gyroscopes. The control of this device is implemented through a digital design on a Field Programmable Gate Array (FPGA). The hardware platform easily transitions to an embedded solution that allows for the miniaturization of the system to a single chip.

evolvable hardware

Spacecraft methods and structures with enhanced attitude control that facilitates gyroscope substitutions

Methods and structures are provided that enhance attitude control during gyroscope substitutions by insuring that a spacecraft's attitude control system does not drive its absolute-attitude sensors out of their capture ranges. In a method embodiment, an operational process-noise covariance Q of a Kalman filter is temporarily replaced with a substantially greater interim process-noise covariance Q. This replacement increases the weight given to the most recent attitude measurements and hastens the reduction of attitude errors and gyroscope bias errors. The error effect of the substituted gyroscopes is reduced and the absolute-attitude sensors are not driven out of their capture range. In another method embodiment, this replacement is preceded by the temporary replacement of an operational measurement-noise variance R with a substantially larger interim measurement-noise variance R to reduce transients during the gyroscope substitutions.

Li, Rongsheng

Parametrically disciplined operation of a vibratory gyroscope

Parametrically disciplined operation of a symmetric nearly degenerate mode vibratory gyroscope is disclosed. A parametrically-disciplined inertial wave gyroscope having a natural oscillation frequency in the neighborhood of a sub-harmonic of an external stable clock reference is produced by driving an electrostatic bias electrode at approximately twice this sub-harmonic frequency to achieve disciplined frequency and phase operation of the resonator. A nearly symmetric parametrically-disciplined inertial wave gyroscope that can oscillate in any transverse direction and has more than one bias electrostatic electrode that can be independently driven at twice its oscillation frequency at an amplitude and phase that disciplines its damping to zero in any vibration direction. In addition, operation of a parametrically-disciplined inertial wave gyroscope is taught in which the precession rate of the driven vibration pattern is digitally disciplined to a prescribed non-zero reference value.

Shcheglov, Kirill V.

Continuous Tuning and Calibration of Vibratory Gyroscopes

A method of control and operation of an inertial reference unit (IRU) based on vibratory gyroscopes provides for continuously repeated cycles of tuning and calibration. The method is intended especially for application to an IRU containing vibratory gyroscopes that are integral parts of microelectromechanical systems (MEMS) and that have cloverleaf designs, as described in several previous NASA Tech Briefs articles. The method provides for minimization of several measures of spurious gyroscope output, including zero-rate offset (ZRO), angle random walk (ARW), and rate drift. These benefits are afforded both at startup and thereafter during continuing operation, in the presence of unknown rotation rates and changes in temperature. A vibratory gyroscope contains a precision mechanically resonant structure containing two normal modes of vibration nominally degenerate in frequency and strongly coupled via a Coriolis term. In the case of the cloverleaf design MEMS gyro, these normal modes of vibration are plate rocking modes. The rocking motion of the plate is described by giving two angles, theta(sub 1) and theta(sub 2). A proof mass consisting of a post orthogonal to the plate ensures a high degree of Coriolis coupling of vibratory energy from one mode into the other under inertial rotation. The plate is driven and sensed capacitively across a few-microns-wide gap, and the normal mode frequencies can be tuned electrostatically by DC voltages applied across this gap. In order to sense rotation, the resonator plate is caused to rock in the theta(sub 1) direction, then any small motions in the theta(sub 2) direction are sensed, rebalanced, and interpreted as inertial rotation. In this scenario, the "drive" has been assigned to the theta(sub 1) direction, and the "sense" has been assigned to the theta(sub 2) direction.

Hayworth, Ken

Frequency-dependent hydrodynamic inductance and the determination of the thermal and quantum noise of a superfluid gyroscope

We reexamine mass flow in a superfluid gyroscope containing a superfluid Josephson weak link. We introduce a frequency-dependent hydrodynamic inductance to account for an oscillatory flow of the normal fluid component in the sensing loop. With this hydrodynamic inductance, we derive the thermal phase noise, and hence the thermal rotational noise of the gyroscope. We examine the thermodynamic stability of the system based on an analysis of the free energy. We derive a quantum phase noise, which is analogous to the zero-point motion of a simple harmonic oscillator. The configuration of the studied gyroscope is analogous to a conventional superconducting RF SQUID. We show that the gyroscope has very low intrinsic noise (1.9x10(-13) rad s(-1)/root Hz), and it can potentially be applied to study general relativity, Earth science, and to improve global positioning systems (GPS).

Penanen, Konstantin

Evolutionary Computation Applied to the Tuning of MEMS Gyroscopes

We propose a tuning method for MEMS gyroscopes based on evolutionary computation to efficiently increase the sensitivity of MEMS gyroscopes through tuning and, furthermore, to find the optimally tuned configuration for this state of increased sensitivity. The tuning method was tested for the second generation JPL/Boeing Post-resonator MEMS gyroscope using the measurement of the frequency response of the MEMS device in open-loop operation.

evolvable hardware

The Stanford gyroscope experiment

Gyroscopes in motion about a massive body are found to have two main effects: (1) geodetic effect, solely due to motion of the gyroscope about the earth and (2) motional effect, due to earth rotation. An experiment is proposed to measure the precession rate of one or more gyroscopes, mounted either on earth or in a satellite, with respect to the axis of a telescope pointing at a suitable fixed star. The procedures and apparatus to be used in this experiment are outlined; the error analysis is summarized. The relation of error to size, speed, and mechanical properties of rotor is presented, along with the design requirements for accuracy of 10 to the -16th power rad/s.

Everitt, C. W. F.

Gyroscope relativity experiment

A gyroscope test of general relativity theory is proposed. The basic ideas and hardware concepts conceived by the investigators to implement the experiment are discussed. The goal is to measure the extremely small relativistic precession of gyroscopes in an earth-orbiting satellite. The experiment hardware (cryogenic gyroscopes, a telescope and superconducting circuits) is enclosed in a liquid helium dewar. The experiment will operate in orbit for about one year.

Decher, R.

Space vehicle gyroscope sensor applications

Considerations which form the basis for the specification, design and evaluation of gyroscopes for spaceborne sensor applications are presented. The applications are distinguished by basic vehicle category: launch vehicles, spacecraft, entry vehicles and sounding rockets. Specifically excluded from discussion are gyroscope effector applications. Exotic or unconventional gyroscopes for which operational experience is nonexistent are mentioned only briefly to alert the reader of future trends. General requirements for testing and evaluation are discussed.

Source record

A SQUID readout system for a superconducting gyroscope

A design of a read out system for a superconducting gyroscope to be used in an orbiting gyroscope relativity experiment is discussed. The 'London Moment' of the superconducting rotor, which lies along the spin axis of the rotor, will be measured with a SQUID-type magnetometer. The SQUID will be built around the gyro rotor, with a very close spacing to give an inductance between 10 millionths and 1 millionth Hy. A SQUID of this design should resolve 2.07 times 10 to the minus 19th weber. The angular resolution of the gyroscope will then be 0.0035 arc-second, which is sufficient for the intended experiment.

Hendricks, J. B.

Optical gyroscope

Instrument uses phase difference between two beams of light to measure rotation. It is considerably simpler and more reliable than conventional spinning-mass gyroscopes used for inertial guidance and is more compact, lighter, and potentially less expensive. Moreover, optical gyroscope requires no warmup period. Although conceived for spacecraft and satellite stabilization, gyroscope should also find applications in flight instruments for private, commercial, and military aircraft.

Goldstein, R. M.

Manufacturing techniques for Gravity Probe B gyroscopes

Additional and improved techniques for the manufacture of Gravity Probe B gyroscopes are reported. Improvements discussed include the redesign of the housings, new techniques for indentation of the electrode surfaces, and a new rotor ball lapping machine. These three items represent a significant improvement in operation of the gyroscope and also make possible the fabrication of a gyroscope which will meet flight requirements.

Rasquin, J. R.

Ultra-low magnetic field apparatus for a cryogenic gyroscope

An ultralow magnetic field apparatus for earth-based testing of a cryogenic gyroscope system designed for a satellite test of general relativity is described. The magnetic field apparatus makes use of a superconducting lead shield while also maintaining sufficient mechanical stability to obtain a gyroscope readout sensitivity of one arcsec over a limited range. A gyroscope environment of 2.3 times 10 to the minus seventh power gauss has been attained with the magnetic field shielding technique. The magnetic field apparatus is to be used with a three-axis London moment readout system.

Cabrera, B.

A superconducting gyroscope to test Einstein's general theory of relativity

Schiff (1960) proposed a new test of general relativity based on measuring the precessions of the spin axes of gyroscopes in earth orbit. Since 1963 a Stanford research team has been developing an experiment to measure the two effects calculated by Schiff. The gyroscope consists of a uniform sphere of fused quartz 38 mm in diameter, coated with superconductor, electrically suspended and spinning at about 170 Hz in vacuum. The paper describes the proposed flight apparatus and the current state of development of the gyroscope, including techniques for manufacturing and measuring the gyro rotor and housing, generating ultralow magnetic fields, and mechanizing the readout.

Everitt, C. W. F.

The Gravity-Probe-B relativity gyroscope experiment - An update on progress

The Gravity-Probe-B (GP-B) relativity gyroscope experiment will test two effects of general relativity: (1) the geodetic precession of a gyroscope due to its Fermi-Walker transport around a massive central body; and (2) the motional or gravitomagnetic precession of the gyroscope due to rotation of the central body itself. The experiment will also provide a determination of the deflection of starlight by the sun and an improved determination of the distance to Rigel. In the Shuttle testing phase of the program, prototype hardware is being developed for a full-scale ground model of the GP-B instrument.

Parkinson, Bradford W.

The Gravity-Probe-B relativity gyroscope experiment - Development of the prototype flight instrument

The Gravity-Probe-B relativity gyroscope experiment (GP-B) will measure the geodetic and frame-dragging precession rates of gyroscopes in a 650 km high polar orbit about the earth. The goal is to measure these two effects, which are predicted by Einstein's General Theory of Relativity, to 0.01 percent (geodetic) and 1 percent (frame-dragging). This paper presents the development progress for full-size prototype flight hardware including the gyroscopes, gyro readout and magnetic shielding system, and an integrated ground test instrument.

Turneaure, J. P.

Investigation of a geodesy coexperiment to the Gravity Probe B relativity gyroscope program

Geodesy is the science of measuring the gravitational field of and positions on the Earth. Estimation of the gravitational field via gravitation gradiometry, the measurement of variations in the direction and magnitude of gravitation with respect to position, is this dissertation's focus. Gravity Probe B (GP-B) is a Stanford satellite experiment in gravitational physics. GP-B will measure the precession the rotating Earth causes on the space time around it by observing the precessions of four gyroscopes in a circular, polar, drag-free orbit at 650 km altitude. The gyroscopes are nearly perfect niobium-coated spheres of quartz, operating at 1.8 K to permit observations with extremely low thermal noise. The permissible gyroscope drift rate is miniscule, so the torques on the gyros must be tiny. A drag-free control system, by canceling accelerations caused by nongravitational forces, minimizes the support forces and hence torques. The GP-B system offers two main possibilities for geodesy. One is as a drag-free satellite to be used in trajectory-based estimates of the Earth's gravity field. We described calculations involving that approach in our previous reports, including comparison of laser only, GPS only, and combined tracking and a preliminary estimate of the possibility of estimating relativistic effects on the orbit. The second possibility is gradiometry. This technique has received a more cursory examination in previous reports, so we concentrate on it here. We explore the feasibility of using the residual suspension forces centering the GP-B gyros as gradiometer signals for geodesy. The objective of this work is a statistical prediction of the formal uncertainty in an estimate of the Earth's gravitation field using data from GP-B. We perform an instrument analysis and apply two mathematical techniques to predict uncertainty. One is an analytical approach using a flat-Earth approximation to predict geopotential information quality as a function of spatial wavelength. The second estimates the covariance matrix arising in a least-squares estimate of a spherical harmonic representation of the geopotential using GP-B gradiometer data. The results show that the GP-B data set can be used to create a consistent estimate of the geopotential up to spherical harmonic degree and order 60. The formal uncertainty of all coefficients between degrees 5 and 50 is reduced by factors of up to 30 over current satellite-only estimates and up to 7 over estimates which include surface data. The primary conclusion resulting from this study is that the gravitation gradiometer geodesy coexperiment to GP-B is both feasible and attractive.

Everitt, C. W. F.

Observation of the London moment and trapped flux in precision gyroscopes

The London-moment readout has been observed in flight quality gyroscopes and it has been demonstrated that it is possible to reduce magnetic field trapped in these gyroscopes to levels as low as 1.5 x 10 exp -11 T. A preliminary analysis shows that the horizontal component of the London-moment signal is 60 percent of the total expected London-moment signal and is proportional to the gyro spin speed. Experiments were carried out in a unique ground test facility which was designed to provide the conditions necessary to observe the London moment of the spinning gyroscope.

Xiao, Y. M.