Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Gamma ray spectroscopy in astrophysics: Solar gamma ray astronomy on solar maximum mission

The SMM gamma ray experiment and the important scientific capabilities of the instrument are discussed. The flare size detectable as a function of spectrum integration time was studied. A preliminary estimate indicates that a solar gamma ray line at 4.4 MeV one-fifth the intensity of that believed to have been emitted on 4 August 1972 can be detected in approximately 1000 sec with a confidence level of 99%.

Forrest, D. J.↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gamma-ray spectroscopy - Status and prospects

Contemporary gamma-ray spectroscopy instruments and their results are reviewed. Sensitivities of 10 to the -4th to 10 to the -3rd ph/sq cm-sec have been achieved for steady sources and 10 to the -2nd to 1 ph/sq cm-sec for transient sources. This has led to the detection of gamma-ray lines from more than 40 objects representing 6 classes of astrophysical phenomena. The lines carry model-independent information and are of fundamental importance to theoretical modeling and our understanding of the objects. The objectives and anticipated results of future instruments are discussed. Several instruments in development will have a factor of 10 sensitivity improvement to certain phenomena over contemporary instruments. A factor of 100 improvement in sensitivity will allow the full potential of gamma-ray spectroscopy to be realized. Instrument concepts which would achieve this with both present and advanced techniques are discussed.

Matteson, J. L.↗

Application of the Approximate Bayesian Computation Algorithm to Gamma-Ray Spectroscopy

Radioisotope identification (RIID) algorithms for gamma-ray spectroscopy aim to infer what isotopes are present and in what amounts in test items. RIID algorithms either use all energy channels in the analysis region or only energy channels in and near identified peaks. Because many RIID algorithms rely on locating peaks and estimating each peak’s net area, peak location and peak area estimation algorithms continue to be developed for gamma-ray spectroscopy. This paper shows that approximate Bayesian computation (ABC) can be effective for peak location and area estimation. Algorithms to locate peaks can be applied to raw or smoothed data, and among several smoothing options, the iterative bias reduction algorithm (IBR) is recommended; the use of IBR with ABC is shown to potentially reduce uncertainty in peak location estimation. Extracted peak locations and areas can then be used as summary statistics in a new ABC-based RIID. ABC allows for easy experimentation with candidate summary statistics such as goodness-of-fit scores and peak areas that are extracted from relatively high dimensional gamma spectra with photopeaks (1024 or more energy channels) consisting of count rates versus energy for a large number of gamma energies.

Burr, Tom↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗

Planetary gamma-ray spectroscopy

The measured intensities of certain gamma rays of specific energies escaping from a planetary surface can be used to determine the abundances of a number of elements. The fluxes of the more intense gamma-ray lines emitted from 32 elements were calculated using current nuclear data and existing models for the source processes. The source strengths for neutron-capture reactions were modified from those previously used. The fluxes emitted form a surface of average lunar composition are reported for 292 gamma-ray lines. These theoretical fluxes were used elsewhere to convert the data from the Apollo gamma-ray spectrometers to elemental abundances and can be used with measurements from future missions to map the concentrations of a number of elements over a planet's surface. Detection sensitivities for these elements are examined and applications of gamma-ray spectroscopy for future orbiters to Mars and other solar-system objects are discussed.

Reedy, R. C.↗

Planetary gamma-ray spectroscopy

The measured intensities of certain gamma rays of specific energies escaping from a planetary surface can be used to determine the abundances of a number of elements. The fluxes of the more intense gamma ray lines emitted from 32 elements have been calculated using current nuclear data and existing models for the source processes. The fluxes emitted from a surface of average lunar composition are reported for 292 gamma ray lines. Detection sensitivities for various elements are examined and applications of gamma ray spectroscopy for future orbiters to Mars and other solar system objects are discussed.

Reedy, R. C.↗