Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rocks, water, and noble liquids: Unfolding the flavor contents of supernova neutrinos

Measuring core-collapse supernova neutrinos, both from individual supernovae within the Milky Way and from past core collapses throughout the Universe (the diffuse supernova neutrino background, or DSNB), is one of the main goals of current and next generation neutrino experiments. Detecting the heavy-lepton flavor (muon and tau types, collectively v x ) component of the flux is particularly challenging due to small statistics and large backgrounds. Further, while the next galactic neutrino burst will be observed in a plethora of neutrino channels, allowing us to measure a small number of v x events, only upper limits are anticipated for the diffuse v x flux even after decades of data taking with conventional detectors. However, paleo detectors could measure the time-integrated flux of neutrinos from galactic core-collapse supernovae via flavor-blind neutral current interactions. In this work, we show how combining a measurement of the average galactic core-collapse supernova flux with paleo detectors and measurements of the DSNB electron-type neutrino fluxes with the next-generation water Cherenkov detector Hyper-Kamiokande and the liquid noble gas detector DUNE will allow to determine the mean supernova vx flux parameters with precision of order ten percent. Realizing this potential requires both the cosmic supernova rate out to z~1 and the integrated Galactic supernova rate over the last ~1 Gyr to be established at the ~10% level.

79 ASTRONOMY AND ASTROPHYSICS↗

Next Generation Noble Liquid Detectors

The research program here combines Generic and Directed R\&D for Liquid Noble Gas detectors for neutrino physics and dark matter. In neutrino physics and dark matter research, we are addressing some of the most fundamental questions in particle physics today by studying these tiny particles in the electron family. To study them, detectors must be large, high precision, and ideally have the ability to collect detailed information from both charge and light from neutrino and dark matter interactions. Precision detection combined with large scales can be challenging. Liquid Argon detectors mitigate some of these challenges given the nature of its interaction medium and it’s relatively inexpensive cost per ton. Significant progress has been made in the last 15 years in developing these kinds of detectors to be built and operated at large scales. However there are still challenges and new ideas in moving these detectors from ton scale to kiloton scale. To be able to get the most out of these kinds of detectors directed questions with respect to specific components running and colleting data in the detectors must be understood. As well, new ideas on how to best combine charge and light measurements may lead to new ways to learn new things with these detectors. Experimental test stands to conduct this work, as is done in this proposal, to accomplish both of these goals are critical to address both of these questions. In the test stand enabled under this grant at Yale University’s Wright lab, new developments in efficient small scale setups were developed, instrumentation developed for running and future experiments (the SBND experiment at Fermilab at present, the DUNE experiment in the future) were and will be tested, and new ideas for charge and light determination for new measurements are under study. The long term impact of this work in neutrino physcis is both for the short and long baseline programs originating at Fermi National Accelerator Laboratory. At long baselines, the US flagship DUNE experiment will measure neutrino properties through neutrino oscillations using a beam originating at Fermilab and a massive LArTPC detector sited about a mile underground at the Sanford Underground Research Facility in Lead, South Dakota. Studies here on the high voltage for thes detectors, and ongoing work on charge and light production and collection in the TPC are relevant for the design and data taking of this and other LArTPC detectors to enable them to best measure the neutrinos created at Fermilab that then pass through the detector in South Dakota. What we learn in these detectors may ultimately change the course of how we understand neutrino’s impact in the early universe. What we learn about how to improve this detection technology and develop new ideas in Lar detectors in general may impact both future neutrino experiments and dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing and controlling oxygen impurity diffusion in h -BN semi-bulk crystals

Combining its unique features of ultrawide bandgap (UWBG) and two-dimensional nature, h-BN has been explored for emerging applications such as deep ultraviolet optoelectronic devices and single photon emitters. One of the unusual applications of h-BN is for solid-state neutron detectors by utilizing the property of high thermal neutron capture cross section of B-10 as well as its UWBG properties. Although a record high detection efficiency of 59% has been attained by h-BN detectors, the understanding/minimization of defects and impurities is still needed to further advance the h-BN material and detector technologies. We report metal organic chemical vapor deposition growth and oxygen (O) impurity diffusion in thick h-BN. The diffusion coefficient (D) of O impurities has been measured via the evolution of an oxygen related emission with the etching depth, providing a value of D of ∼ 2 × 10−13 cm2/s at 1450 °C and supporting the interpretation that oxygen in h-BN is a substitutional donor. A multiple-buffer-layer approach was employed to mitigate to a certain degree the issue of oxygen diffusion from sapphire substrate during growth. It was demonstrated that the performance of h-BN neutron detectors fabricated from the wafer incorporating multiple buffer layers was significantly improved, as manifested by the enhanced thermal neutron detection efficiency. The advancement of the crystal growth technology of h-BN semi-bulk crystals creates applications in optoelectronic and power electronic devices utilizing the UWBG semiconductor properties of h-BN, while high efficiency h-BN neutron detectors have the potential to supplant the traditional He-3 gas detectors in various application areas by offering the obvious advantages of UWBG semiconductor technologies.

Physics↗

Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter Onboard the IXPE Mission

The Gas Pixel Detector is a gas detector, sensitive to the polarization of X-rays, currently flying onboard the Imaging X-ray Polarimetry Explorer (IXPE)—the first observatory dedicated to X-ray polarimetry. It detects X-rays and their polarization by imaging the ionization tracks generated by photoelectrons absorbed in the sensitive volume, and then reconstructing the initial direction of the photoelectrons. The primary ionization charge is multiplied and ultimately collected on a finely pixellated ASIC specifically developed for X-ray polarimetry. The signal of individual pixels is processed independently and gain variations can be substantial, of the order of 20%. Such variations need to be equalized to correctly reconstruct the track shape, and therefore its polarization direction. The method to do such equalization is presented here and is based on the comparison between the mean charge of a pixel with respect to the other pixels for equivalent events. The method is shown to finely equalize the response of the detectors onboard IXPE, allowing a better track reconstruction and energy resolution, and can in principle be applied to any imaging detector based on tracks.

79 ASTRONOMY AND ASTROPHYSICS↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus and methods for location and sizing of trace gas sources

A system for detecting gas leaks and determining their location and size. A data gathering portion of the system utilizes a chosen geometrical configuration to collect path-integrated spectroscopic data over multiple paths around an area. A processing portion of the system applies a transport model together with meteorological data of the area to generate an influence function of possible leak locations on gas detector measurement paths, and applies an inversion model to the influence function, prior data, and the spectroscopic data to generate gas source size and location.

03 NATURAL GAS↗

Calibration of the IXPE Focal Plane X-Ray Polarimeters to Polarized Radiation

The Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission—in partnership with the Italian Space Agency—dedicated to X-ray polarimetry in the 2–8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector, a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units at INAF-IAPS, in Italy, where a dedicated facility was setup at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

79 ASTRONOMY AND ASTROPHYSICS↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas sensor including optic fiber connector

A gas detector sensor node includes a first sensor conductor having a terminal end, a second sensor conductor including an end section, and a coupler joining the terminal end of the first sensor conductor with the end section of the second sensor conductor. The coupler is permeable to gas.

Karp, Jason Harris↗

Simulated Performance of the Micro-Pocket Fission Detector in the Advanced Test Reactor Critical Facility

The Micro-Pocket Fission Detector (MPFD) is a small-form–factor real-time fission chamber. MPFD performance has been simulated in the Advanced Test Reactor Critical Facility (ATRC), located at Idaho National Laboratory (INL). Here, the neutron and gamma-ray flux profiles and magnitudes were simulated using Monte Carlo N-Particle (MCNP) in the near-core B-8 irradiation position. These simulations were performed at 69 discrete axial locations inside the B-8 position for three separate orientations of the nearby hafnium outer shim control cylinders and at a power level of 700 Wth. The resulting neutron and gamma-ray flux values were used to determine the MPFD response for various fissile masses and detector gas pressures. The optimal gas-operating pressure was determined to be between 30 and 60 psig. The required fissile-layer mass was determined to be between 1–2 µg of 235 U. Additionally, the gamma-ray to fission-fragment interaction rate was determined to be 4.42 × 10 -3 with average energy deposition for gamma rays and fission fragments in 30 psig argon gas to be 1 keV and 9.5 MeV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methane generation from low-maturity coals and shale source rocks at low temperatures (80–120 °C) over 14–38 months

This study contributes long-term (14 to 38 months) experimental evidence for geocatalytically mediated methanogenesis in immature to early mature shale and coal source rocks at temperatures from 80 to 120 °C. Borosilicate glass tubes with pre-outgassed coal and shale source rock chips and water were sealed under vacuum, sterilized, heated isothermally, and finally opened in connection with a vacuum line where headspace gases methane (CH 4 ) and carbon dioxide (CO 2 ) were collected. The possibility of admitting pre-existing CH 4 from closed pores into product gases during heating experiments was evaluated by comparative ball milling of original and heated rock chips, followed by quantitation of released gases with a novel closed-circuit laser-based SARAD RTM2200 gas detector system with sub-µmol sensitivity. The yields of produced CH 4 from individual source rocks were corrected by subtracting the amounts of pre-existing CH 4 from formerly closed pores in original source rocks that had leaked during long-term heating. Different shales and coals express contrasting propensities to geocatalytically generate CH 4 and CO 2 , with CH 4 yields ranging from 0.1 to 5.5 µmol g-1 total organic carbon (TOC). CH 4 yields from two petrographically different samples of Springfield Coal with comparable thermal maturity suggest that liptinite expresses a far higher propensity for methanogenesis, but liberates less CO 2 than vitrinite. Shale from the Second White Specks Formation generated approximately 10 times more CH 4 than New Albany Shale per g of TOC, further suggesting complex controls on CH 4 generation during catalytic methanogenesis. Higher temperature can enhance the activities of catalytic methanogenesis. Here, the extrapolation of laboratory-based reaction rates to natural conditions in organic-rich buried sediments suggests that geocatalytic methanogenesis can be fast enough in some source rocks to generate economically sizeable gas plays from immature to early mature source rocks over geologic time.

03 NATURAL GAS↗

Aerosol-Jet Printed Sensors for Environmental, Safety, and Health Monitoring: A Review

An emergent direct-write approach, aerosol-jet printing (AJP), is gaining attention for the deployment of rapid and affordable microadditively manufactured energy-efficient sensors and printed electronics. AJP enables a broad range of ink viscosities (0.001–1 Pa s) for printing diverse materials ranging from ceramics and metals to polymers and biological matter. Reproducible, high-spatial-resolution features (≈10 µm), and wide standoff distances (1–11 mm) between the nozzle and the substrate facilitate conformal printing of complex geometrical designs on nonplanar—e.g., stepped or curved—surfaces. Here this paper aims to provide a comprehensive overview of state-of-the-art AJP-based sensors (e.g., strain and temperature gauges, biosensors, photosensors, humidity and surface acoustic wave sensors, dielectric elastomer actuators, and motion, smoke, and hazardous gas detectors) and to discuss prospective applications. The drive toward cost-effective devices that are smaller, lighter, and better-performing remains a frontier challenge in the field of printed electronics. Consequently, as AJP becomes increasingly utilized in the high-volume manufacturing of miniaturized active and passive sensors, it opens a pathway for facile large-scale fabrication of devices for a wide range of consumer and industrial applications, including transportation, agriculture, infrastructure, aerospace, national defense, and healthcare.

3-dimensional↗

Space charge effects in the SπRIT time projection chamber

Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from the ionization of the detector gas by the beam creates the main source of space charge, distorting the nominal electric field of the TPC. This has a profound effect on the accuracy of the measured momenta of the emitted particles. In this paper we will discuss the magnitude of the effects and construct an observable appropriate for fixed target experiments to study the effects. Finally, we will present an algorithm for correcting the space charge and discuss some of the implications it has on the momentum determination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring strips. However, to effectively extract the inherent positional information, the lateral spacing of the straight strips must be comparable to or preferably smaller than the full extent of the incident charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the incident charge with a pitch appreciably larger than the charge cloud.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel Perovskite Semiconductors for the Detection of Special Nuclear Material

Special nuclear material detection using portable, highly efficient detectors is of paramount importance to national security and environmental monitoring. Current neutron detectors, including gas proportional counters and scintillators, are not suitable for discrete or portable monitoring due to size, weight, and power limitations. For example, 3 He gas proportional detectors have significant drawbacks, including long absorption lengths, high voltage requirements, and dependence on the availability of 3 He. The goal of this project is to synthesize a novel, boron-based perovskite semiconductor crystals to create a more efficient and more portable neutron detector. This innovative material will lead to a significant decrease in power and size requirements with higher operating temperatures than other traditional solid-state detectors. Directly incorporating 10 B eliminates the need for a conversion layer and leads to high neutron absorption coefficients. In this seedling project, we used inverse temperature crystallization with boron precursors to create CH 3 NH 3 PbI 3-x (BF 4 ) x . The crystals were analyzed with X-ray diffraction, but the results were inconclusive. Future work will focus on tailoring the solution growth and selecting appropriate solvents and precursors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum

Inelastic beam-gas collisions at the Large Hadron Collider (LHC), within a few hundred metres of the ATLAS experiment, are known to give the dominant contribution to beam backgrounds. These are monitored by ATLAS with a dedicated Beam Conditions Monitor (BCM) and with the rate of fake jets in the calorimeters. These two methods are complementary since the BCM probes backgrounds just around the beam pipe while fake jets are observed at radii of up to several metres. In order to quantify the correlation between the residual gas density in the LHC beam vacuum and the experimental backgrounds recorded by ATLAS, several dedicated tests were performed during LHC Run 2. Local pressure bumps, with a gas density several orders of magnitude higher than during normal operation, were introduced at different locations. The changes of beam-related backgrounds, seen in ATLAS, are correlated with the local pressure variation. In addition the rates of beam-gas events are estimated from the pressure measurements and pressure bump profiles obtained from calculations. Using these rates, the efficiency of the ATLAS beam background monitors to detect beam-gas events is derived as a function of distance from the interaction point. These efficiencies and characteristic distributions of fake jets from the beam backgrounds are found to be in good agreement with results of beam-gas simulations performed with theFluka Monte Carlo programme.

43 PARTICLE ACCELERATORS↗