Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas systems and purification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

"Source Term Modeling for Advanced Gas Micro-Reactors"

Maintaining the safety of the public, environment, and operating personnel is the most important factor in designing, operating, maintaining, and decommissioning nuclear reactors. In recent years, there has been a growing interest in the development of micro-reactors employing TRi-structural ISOtropic (TRISO)-coated particle fuel. In gas reactors, TRISO fuel plays an important role in the safety case for high temperature reactors because of the fission product retention properties of the fuel. This ability enables the use of a functional containment strategy for the reactor where multiple barriers are used to prevent fission product release to the environment. Part of the safety analysis of these advanced reactors is the assessment of radionuclide releases under normal and accident conditions through the multiple credited safety barriers. Using conservative assumptions, a mechanistic analysis can be performed to quantify these releases that combines the probabilistic assessment of failure with analytic solutions to radionuclide transport equations. Source term modeling for TRISO fuel has been performed for previous reactor designs; however, these models are outdated, in many cases proprietary, and need updates to be applied to the current state of TRISO fuel technology and alternative gas reactor core configurations [1]. Currently, the only publicly available source term assessment for gas reactors is an expert-based Monte Carlo simulation based on the effectiveness of the fuel kernel, coating layers, and graphite block in a modular high temperature gas reactor [2]. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that could be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. The release is calculated by the diffusion of the key safety important fission products through the kernel, silicon carbide (SiC), graphite for both intact and defective TRISO particles based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system to remove fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. The model then can calculate the fission product release for any transient temperature profile and fission product releases can then be used to assess radiological dose to the workers and the public using conventional dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy (DOE) Advanced Gas Reactor (AGR) TRISO fuel development program. The model is coded in python with inputs and outputs in excel spreadsheets, as well as python plotting utilities to aid in the interpretation of the results. References: [1] INL, NGNP Mechanistic Source Term White Paper, INL-10-17997, July 2010. [2] David A. Petti, Richard R. Hobbins, Peter Lowry, Hans Gougar, “Representative Source Terms and The Influence of Reactor Attributes on Functional Containment in Modular High Temperature Gas-cooled Reactors,” Nuclear Technology, Vol. 184, p. 181-197, Nov. 2013.

07 ISOTOPE AND RADIATION SOURCES↗

Sorption Enhanced Mixed Matrix Membranes for Hydrogen (H 2 ) Purification and Carbon Dioxide (CO 2 ) Capture

The technical objective of this project was to develop sorption enhanced mixed matrix membranes with H 2 permeance of 500 gas permeance units (GPU) and H 2 /CO 2 selectivity of 30 at 150-200 °C. These membranes will be the central component in the design of membrane based systems for 90% capture of CO 2 from coal-derived syngas, with 95% CO 2 purity at a cost of electricity 30% less than baseline capture approaches. The unique approach in this proposal is to design crosslinked polymers containing Pd-based nanoparticles achieving strong H 2 sorption and size sieving ability and thus H 2 /CO 2 selectivity. The specific objectives for each budget period (BP) are described below. BP 1: Identify polymer matrix with strong size sieving ability and palladium (Pd)-containing nanomaterials to prepare freestanding mixed matrix films with H 2 permeability of 50 Barrer and H 2 /CO 2 selectivity of 30 at 150-200°C with simulated syngas. BP 2: Prepare and optimize thin film mixed matrix composite membranes materials with H 2 permeance of 500 GPU and H 2 /CO 2 selectivity of 30 at 150-200 °C, and complete the modification of the membrane test unit for the field test in the BP 3. BP 3: Conduct a 20-day field test of the membranes with real syngas at Center for Advanced Energy Research (CAER) of the University of Kentucky (UKy). During the BP2, we have successfully prepared thin-film composite (TFC) membranes based on mixed matrix materials (MMMs) containing Pd nanoparticles in polymers, and demonstrated their superior and robust performance for H 2 /CO 2 separation at 150 – 225 °C. (1) Production of the Pd based nanoparticles with a diameter of 4 nm has been scaled up to 200 mg/day. (2) We have prepared TFC membranes with H 2 permeance above 500 GPU and H 2 /CO 2 selectivity above 30 at temperatures up to 225 °C, which meet the targets for the BP2. (3) We have conducted parametric studies of TFC membranes with a mixed gas containing H 2 S and H 2 O and demonstrated the stability of the membranes. (4) We have established a new testing plan at the Center for Advanced Energy Studies (CAER) at the University of Kentucky because NCCC decided to shut down their gasifier. During this project, four Ph.D. students received the inter-disciplinary training and graduated, including Shailesh Konda, Maryam Omidvar, Deqiang Yin, and Lingxiang Zhu. One postdoctoral researcher (Dr. Liang Huang) and two Ph.D. students (Abhishek Kumar and Hien Nguyen) are involved in this project. The project leads to one provisional patent application, eight peer-reviewed articles, and one manuscript in preparation. The details are shown below.

01 COAL, LIGNITE, AND PEAT↗

Comparing energy and water use of aqueous and gas-based metalworking fluids

Gas-based metalworking fluids (MWFs) have been proposed as alternative coolants and lubricants in machining operations to mitigate concerns surrounding water use and pollution, industrial hygiene, occupational health, and performance limitations associated with water-based (aqueous) MWFs that are ubiquitously used in the metals manufacturing industry. This study compares the primary energy and water use associated with the consumptive use, delivery, and disposal of aqueous MWFs with three gas-based MWFs in the literature-minimum quantity lubricant-in-compressed air (MQL), liquid/gaseous N-2, and liquid/supercritical CO2. The comparison accounts for reported differences in machining performance in peer-reviewed experimental studies across several machining processes and materials. The analysis shows that despite the reported improvement in tool life with N-2 and CO2-based MWFs, the electricity- and water-intensive separation and purification processes for N-2 and CO2 lead to their higher primary energy and water use per volume of material machined relative to water-based MWFs. Although MQL is found to have lower primary energy use, significant consumptive water use associated with the vegetable oil commonly used with this MWF leads to higher overall water use than aqueous MWF, which is operated in a recirculative system. Gas-based MWFs thus shift the water use upstream of the manufacturing plant. Primary energy and water use of gas-based MWFs could be reduced by focusing on achieving higher material removal rates and throughput compared to aqueous MWF instead of solely targeting improvements in tool life. Additionally, the consumptive use of CO2 and N-2 MWFs could be minimized by optimizing their flow rates and delivery to precisely meet the cooling and lubrication needs of specific machining processes instead of flooding the tool and workpiece with these gases. This article met the requirements for a gold-gold JIE data openness badge described at http://jie.click/badges.

cutting fluids↗

Triso Analysis Tool For Predictive Source Terms

Source term modeling for TRi-structural ISOtropic (TRISO) fuel has been performed for previous reactor designs, but few are available in the open literature. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that can be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. To meet this need, the TRISO Analysis Tool for Predictive Source terms (TRISO-ATOPS) was developed. This model calculates the release of the key safety-important fission products by diffusion through the kernel, silicon carbide and graphite based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system for removing fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. From this initial condition, the model calculates the fission product release for any transient temperature profile, and the fission product releases can then be used to assess radiological dose to the workers and the public using conventional radiological dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy Advanced Gas Reactor TRISO fuel development program. The example cases in this work demonstrate the flexibility of the model

Stoyer, Benjamin [Idaho National Laboratory (INL),↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Development of a Pre-Combustion CO 2 Capture Process Using High-Temperature PBI Hollow-Fiber Membranes

The overall objective of this project was to evaluate the advantages of transformational polybenzimidazole (PBI) polymer hollow-fiber membrane (HFM)-based, carbon dioxide (CO 2 ) capture and purification technology at bench-scale using an actual coal-derived syngas stream from a coal gasification facility. The project was carried out over two budget periods. The technical objectives in Budget Period 1 (BP1) included preparing HFs and modules and upgrading the available skid for field testing. The technical objectives for BP2 were to field-test the skid unit with actual coal-derived syngas from an oxygen-blown gasifier to obtain performance data, update the Techno-Economic Analysis (TEA) that would assist with future process scale-up, and provide information on the design of a small pilot-scale test unit. The goal was to advance the PBI-HFM CO 2 capture and gas separation system for pre-combustion applications beyond second-generation economic performance predictions and make progress toward meeting overall fossil energy performance goals of CO 2 capture with 95% CO 2 purity at a cost of electricity (COE) 30% less than baseline capture approaches. The research program was designed with progressive technical tasks leading to both dynamic and steady-state testing of the PBI-HFM skid with actual coal-derived syngas. The work plan was to: (1) fabricate sufficient Generation-2 (GEN-2) fibers for module fabrication; (2) upgrade the fiber skid to accommodate large fiber modules for bench-scale field testing; (3) conduct dynamic and steady-state testing with coal-derived syngas from an oxygen-blown gasifier and obtain system performance data; (4) perform a TEA and environmental, health, and safety (EH&S) assessment; (5) update the State-Point Data Table, Technology Gap Analysis (TGA), and Technology Maturation Plan (TMP); (6) uninstall and return the test skid to the Recipient’s facilities; and (7) submit a Final Report that describes the results and analysis of the project research effort.

03 NATURAL GAS↗

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING↗

Chemical Recycling of Polycaprolactones via Reactive Melt Processing

Chemical recycling is a promising technology for the deconstruction of waste plastics into monomers or other chemical intermediates, which can be converted into other value-added products or repolymerized into polymers. In this work, polycaprolactone and poly(4-propylcaprolactone) were chemically recycled by exploiting ring-closing depolymerization (RCD). To demonstrate the utility of this approach, reactive distillation experiments were initially conducted in a heated round-bottom flask with a distillation head to explore the effect of temperature and catalyst loading on RCD. Inspired by industrial devolatilization equipment, analogous experiments were conducted using a twin-screw melt compounder that was modified to simultaneously heat and mix polymer in the presence of a catalyst while continuously removing the evolved monomer vapors with a vacuum system and collecting them in a cold trap. Yield and selectivity of the recovered monomer were characterized by 1 H nuclear magnetic resonance spectroscopy and gas chromatography-mass spectrometry. Importantly, the more scalable twin-screw melt compounder approach produced values of monomer selectivity (∼90%) and yield (∼80%) similar to those of the round-bottom flask experiments. The recovered monomers were also successfully repolymerized into the same neat polymer with comparable molar masses without purification steps or adding initiator. Here, the results of this study promote the use of reactive devolatilization extrusion as a scalable approach to polyester depolymerization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SF6 / Acetone Separation & Purification

Sulfur hexafluoride (SF₆) is recognized as the most potent greenhouse gas used in the power transmission and semiconductor sectors. In the past decade, its global emissions have increased sharply, largely due to the absence of effective disposal and recovery pathways. This concern was formally addressed under the Kyoto Protocol, which urged participating nations to adopt measures to limit SF₆ emissions and mitigate its role in climate change. In recent years, various abatement strategies have been explored, including non-thermal plasma (NTP) technologies such as radio frequency, microwave, dielectric barrier discharge, and electron beam systems. While these methods can decompose SF₆, they also produce hazardous by-products like sulfur oxyfluorides, sulfur dioxide, hydrofluoric acid, and fluorine gas. Because these compounds pose both environmental and health risks, replacing traditional disposal practices with modern, more effective treatment methods has become an urgent priority.

36 MATERIALS SCIENCE↗

In-situ resource utilization-derived water purification and hydrogen and oxygen production

This disclosure provides an integrated system and method for producing purified water, hydrogen, and oxygen from contaminated water. The contaminated water may be derived from regolith-based resources on the moon, Mars, near-Earth asteroids, or other destination in outer space. The integrated system and method utilize a cold trap to receive the contaminated water in a vapor phase and selectively freeze out water from one or more volatiles. A heat source increases temperature in the cold trap to vaporize the frozen contaminated water to produce a gas stream of water vapor and volatiles. A chemical scrubber may remove one or more volatiles. The integrated system and method utilize ionomer membrane technology to separate the water vapor from remaining volatiles. The water vapor is delivered for crew use or delivered to an electrolyzer to produce hydrogen and oxygen.

Finger, Barry Wynns↗

Development of Self-Assembly Supports Enabling Transformational Membrane Performance for Cost-Effective Carbon Capture

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the U.S. Department of Energy (DOE), National Energy Technology Lab (NETL) on the development of membranes with transformational performance for carbon capture under award number DE-FE0031596. The work was performed from June 1, 2018 through May 31, 2024. For more than a decade, MTR has worked in partnership with DOE to develop an innovative membrane-based CO 2 capture process. This effort has included the first test of membrane modules with coal-fired flue gas at the Arizona Public Services (APS) Cholla plant in 2010; the accumulation of >11,000 hours of flue gas operation for Polaris modules on a bench-scale 1 tonne/day (TPD) system at the National Carbon Capture Center (NCCC); scale-up of first-generation (Gen-1) Polaris to a 20 TPD small pilot system, and successful operation of this system on a flue gas slipstream at NCCC and in integrated boiler testing at Babcock & Wilcox (B&W). Through continued development efforts, a second-generation (Gen-2) version of the Polaris membrane has been scaled-up to pilot production. This membrane offers 70% higher CO 2 permeance with similar selectivity to the base case Polaris. MTR also developed planar modules designed specifically for the low-pressure, high-volumetric flow rate process conditions of flue gas operation. These new modules have significantly lower pressure-drop values compared to the type originally used (spiral-wound modules), which results in significant energy savings. The goal of the work described in this report was to improve on the Polaris Gen-2 membrane with the ultimate aim to reduce the cost of carbon capture. The majority of the effort was to develop improved support membranes for the multi-layer composite structure of MTR’s Polaris membrane. Earlier work at MTR had identified the support structure as limiting membrane permeances, not because the support itself represents a permeation resistance, but because the distribution of pores at the surface of the support imposes a geometric restriction to diffusion in the layers above it. Support membranes were prepared from a range of polymers, including commercially available block copolymers and a custom synthesized block copolymer alternative. The best support membranes developed in this project reduced the geometric restriction by a factor of two to three. These supports then were used to produce Polaris composite membranes with improved permeances. The second topic was to create a high-selectivity version of the Polaris membrane. The high-selectivity version uses a novel selective polymeric material and high selectivities were confirmed in experiments at MTR. The material is not easily made into very thin films. Consequently, the permeances are significantly lower than the Polaris Gen-2 membrane. The utility of this membrane is therefore limited to the carbon dioxide purification step that produces liquid CO 2 . A Technical and Economic Analysis (TEA) was performed for a carbon capture system that uses both advanced membrane types. The TEA shows the novel advanced membranes reduce the cost of capture by 10%, from $63.32/tonne CO 2 to $56.90/tonne CO 2 (2022 USD). Most of the development work was carried out with laboratory-scale casting and coating equipment. A number, but not all, of the improvements identified have been implemented on commercial-scale manufacturing equipment. The focus of future work at MTR is to incorporate the advancements made into the Polaris membrane manufacturing process.

01 COAL, LIGNITE, AND PEAT↗

Electrochemically driven carbon dioxide separation

This project explored the viability of a Ni(OH) 2 based hydroxide exchange membrane carbon capture (HEMCC) device for direct air capture. It is built off an H 2 fuel cell based HEMCC previously developed in the Yushan Yan group at University of Delaware. Taking the same membrane-based, electrochemically driven pH gradient concept, similar flux performance was able to be seen in the Ni(OH) 2 system as the H 2 system when using comparable current densities. The project produced two types of membrane electrode assemblies (MEA). The first was a traditional MEA with two electrodes and a membrane, the second was a flow-through membrane MEA. Consistent performance was achieved with the traditional MEA with an energy cost of 1.1 MWh∙ton -1 and flux of 82 kg∙m -2 ∙yr -1 . This was the most stable of the two designs. This project investigated strategies to improve performance with a flow-through membrane design. Two designs were made, one with a cast phase inversion membrane, and one with powdered membrane layer. The template phase inversion membrane achieved low pressure drop but had performance limitations due to a skin layer of membrane limiting CO 2 gas transport. The powdered membrane layer had better performance but higher pressure drop. Finally, using the powdered membrane, commercial battery materials were able to be used in order to achieve higher flux. This showed that the flow through membrane design does have the capability to overcome flux inefficiencies in the traditional MEA. Moreover, the process design of the system is proposed and given in this project. The process mass and energy balances were calculated for a reference plant of 1000 t/yr CO 2 capture, which contains several subsystems, e.g. air processing subsystem, electrical subsystem, and CO 2 purification and compression subsystem is designed and evaluated. Based on our calculation, When the power consumption for stack is 1 MWh t -1 CO 2 , Additional 382 kWh t -1 CO 2 will be consumed by other subsystem of the plant, i.e. The total power consumption of 1.38 MWh t -1 CO 2 , lower than the final milestone of 1.5 MWh t -1 CO 2 in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cation exchange separation of radium and actinium using lactic acid DTPA buffer

The separation of actinium ( 228 Ac) from radium ( 223,228 Ra) on cation exchange resin with a diethylenetriaminpentaacetic acid-lactate buffer solution is demonstrated with series of columns. High yield, high radiopurity (~ 100%) separations of Ac from Ra are feasible with small columns in biologically compatible conditions and pHs. As Ac is eluted before Ra on these columns, further studies were performed to determine if this separation system could be applied to Ra/Ac isotope generators, but these were not successful. In conclusion, the separations presented in this work may be relevant for radiopharmaceutical purifications of 225 Ac which is typically obtained from its 225 Ra parent isotope.

and nuclear chemistry↗

Air separation and N 2 purification with Ba 0.15 Sr 0.85 FeO 3-$δ$ via a two-step thermochemical process

Thermochemical air separation to produce high-purity N 2 was demonstrated in a vertical tube reactor via a two-step reduction–oxidation cycle with an A-site substituted perovskite Ba 0.15 Sr 0.85 FeO 3–δ (BSF1585). BSF1585 particles were synthesized and characterized in terms of their chemical, morphological, and thermophysical properties. A thermodynamic cycle model and sensitivity analysis using computational heat and mass transfer models of the reactor were used to select the system operating parameters for a concentrating solar thermal-driven process. Thermal reduction up to 800 °C in air and temperature-swing air separation from 800 °C to minimum temperatures between 400 and 600 °C were performed in the reactor containing a 35 g packed bed of BSF1585. The reactor was characterized for dispersion, and air separation was characterized via mass spectrometry. Gas measurements indicated that the reactor produced N 2 with O 2 impurity concentrations as low as 0.02 % for > 30 min of operation. Additionally, a parametric study of air flow rates suggested that differences in observed and thermodynamically predicted O 2 impurities were due to imperfect gas transport in the bed. Temperature swing reduction/oxidation cycling experiments between 800 and 400 °C in air were conducted with no statistically significant degradation in N 2 purity over 50 cycles.

14 SOLAR ENERGY↗

High-temperature corrosion of a nickel-based alloy in a molten chloride environment – The effect of thermal and chemical purifications

There is currently an ever-increasing demand for higher process efficiencies in next generation (Gen3) concentrating solar power (CSP). Higher process efficiencies may be procured by increasing the operating temperature, and simultaneously, minimizing the degradation of materials used for construction of CSP plants (e.g., piping, thermal storage tanks, solar receivers and heat exchangers). Thus, understanding materials corrosion in the presence of molten salt mixtures used as thermal energy storage media and heat transfer fluids is indispensable for CSP development. The present paper provides insights into the effects of salt purification on the corrosion of a nickel-based alloy (Haynes 230) isothermally exposed to a stagnant chloride-based salt mixture at 800 °C. The MgCl 2 -based salt mixture was thermally dehydrated and chemically treated with (0.1 and 0.5 wt %) elemental magnesium. Results reveal the electrochemical nature of the corrosion process, and the formation of corrosion products such as oxides (MgO, MgCr 2 O 4 , and MgAl 2 O 4 ) and nitrides (CrN) on the alloy surface and in sub-surface regions. Magnesium additions enhanced the ability to resist corrosion by reducing the concentration of impurities (H 2 O, MgOH + , OH - species) and polarizing the alloy surface. The formation of nitrides in all cases studied indicates the impact of using nitrogen as a protective gas in the system. Results also reveal that a single step treatment of the salt using metallic Mg could be considered as a measure to control the salt's impurity level, e.g., if required for system control.

14 SOLAR ENERGY↗