At least 37 records · Page 2

Mu2e straw tube tracker gas flow quality control

Here, we present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55 F source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening.

Flow↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

An experiment to verify that the weak interactions satisfy the strong equivalence principle

The construction of a clock based on the beta decay process is proposed to test for any violations by the weak interaction of the strong equivalence principle bu determining whether the weak interaction coupling constant beta is spatially constant or whether it is a function of gravitational potential (U). The clock can be constructed by simply counting the beta disintegrations of some suitable source. The total number of counts are to be taken a measure of elapsed time. The accuracy of the clock is limited by the statistical fluctuations in the number of counts, N, which is equal to the square root of N. Increasing N gives a corresponding increase in accuracy. A source based on the electron capture process can be used so as to avoid low energy electron discrimination problems. Solid state and gaseous detectors are being considered. While the accuracy of this type of beta decay clock is much less than clocks based on the electromagnetic interaction, there is a corresponding lack of knowledge of the behavior of beta as a function of gravitational potential. No predictions from nonmetric theories as to variations in beta are available as yet, but they may occur at the U/sg C level.

Eby, P. B.↗

SPY: a conceptual design study of a magnet system for a high-pressure gaseous TPC neutrino detector

Here, we present a novel conceptual design for a magnet system that provides the magnetic field necessary for the analysis of tracks in a high-pressure gaseous argon TPC while simultaneously serving as a pressure vessel to contain the TPC gas volume. The magnet was developed within a Near Detector proposal for the Deep Underground Neutrino Experiment (DUNE). The high-pressure gaseous argon TPC is a component proposed to be one of the elements of an ensemble of near detectors that are needed for DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Readout electronics for low occupancy High-Pressure Gas TPCs

High-Pressure Gas Time Projection Chambers (HPgTPCs) have benefits such as low energy thresholds, magnetisability, and 4π acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for Gaseous Argon Near Detector (ND-GAr), which is part of the Phase-II more capable near detector for DUNE. These electronics reduce the cost significantly compared to using collider readout electronics, which are typically designed for much higher occupancy and therefore, for example, need much larger numbers of FPGAs and power per channel. We demonstrate the performance of our electronics with the Teststand for an Overpressurised Argon Detector (TOAD) at Fermilab in the US at a range of pressures and gas mixtures up to 4.5 barA, reading out ∼10 000 channels from a Multi-Wire Proportional Chamber (MWPC). The operation took place between April and July of 2024. We measure the noise characteristics of the system to be sufficiently low, and we identify sources of noise that can be further mitigated in the next iteration. We also note that the cooling scheme used in the test requires improvement before full-scale deployment. Despite these necessary improvements, we show that the system can fulfil the needs of a HPgTPC for a fraction of the price of collider readout electronics.

Data acquisition concepts↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy Independence of the Collins Asymmetry in 𝑝 ↑⁢ 𝑝 Collisions

The STAR experiment reports new, high-precision measurements of the transverse single-spin asymmetries for 𝜋 ± within jets, namely the Collins asymmetries, from transversely polarized 𝑝 ↑⁢ 𝑝 collisions at $\sqrt{s}$ = 510 GeV. The energy-scaled distribution of jet transverse momentum, 𝑥 T = 2⁢𝑝 T, jet /$\sqrt{s}$, shows a remarkable consistency for Collins asymmetries of 𝜋 ± in jets between $\sqrt{s}$ = 200 GeV and 510 GeV. This indicates that the Collins asymmetries are nearly energy independent, with, at most, a very weak scale dependence in 𝑝 ↑ ⁢𝑝 collisions. These results extend to high-momentum scales (𝑄 2 ≤ 3400 GeV 2 ) and enable unique tests of evolution and universality in the transverse-momentum-dependent formalism, thus providing important constraints for the Collins fragmentation functions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effects of contamination on gaseous X-ray detectors

Results are presented which detail how the performance of a proportional counter degrades when oxygen is added as a contaminant. It is demonstrated that argon based gas fillings are much less sensitive to electronegative impurities than are xenon filled detectors which can show significant deterioration for contamination levels as low as 10 ppm. The data are particularly relevant to X-ray astronomy, where sealed systems must operate for long periods of time.

Ramsey, B. D.↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e straw tracker detector status and prototype results

The Mu2e experiment will search for charge-lepton flavor violating (CLFV) muon to electron conversion. It aims to achieve a four-orders of magnitude improvement in sensitivity over previous experiments, allowing it to probe new physics at mass scales up to 10 4 TeV . A precision momentum measurement is needed to resolve the monoenergetic electron that is the signal of CLFV conversion from muon decay-in-orbit backgrounds. Here, this is achieved in Mu2e using a low-mass cylindrical straw tracker operated in vacuum, consisting of 21,000 thin-wall mylar straws held at tension. The Mu2e tracker is now in production and will be completed during 2025. We will discuss the design and status of the experiment and the tracker detector, and show results from data taken with the first tracker module.

Gaseous detector↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

FCC feasibility studies: Impact of tracker- and calorimeter-detector performance on jet flavor identification and Higgs physics analyses

The ambitious physics program planned for the Future Circular Collider electron-positron phase imposes stringent constraints on detector performance. This study systematically investigates how different detector configurations impact jet flavor identification and their effects on high-profile physics analyses. Using Higgs boson coupling measurements and searches for invisible Higgs decays as benchmarks, we evaluate the sensitivity of these analyses to variations in tracker and calorimeter detector properties. We examine modifications to single-point resolution, material budget, silicon layer placement, and particle identification capabilities, quantifying their effects on flavor-tagging performance. Additionally, we present the first comprehensive study of Higgs-to-invisible decay detection using full detector simulation, providing insights for optimizing detector designs at lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

SALSA: a new versatile readout chip for MPGD detectors

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other usages of MPGD detectors like TPC or photon detectors. It integrates a frontend block and an ADC for each of the 64 channels, associated to a configurable DSP processor meant to correct data and reduce the raw data flux to limit the output bandwidth. It will be compatible with the continuous readout foreseen for the EPIC DAQ, but will also work in a triggered environment. Several prototypes are already produced in order to qualify the different blocks of the chip, in particular the frontend, the ADC and the clock generation. The next 32-channel prototype is currently under development and is planed to be produced in 2025. In conclusion, the final prototype will be produced and tested from 2026 for a production of the SALSA chip at the horizon of 2027.

Data processing↗