Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gauges”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fully gauge-fixed SU(2) Hamiltonian for quantum simulations

Here, we demonstrate how to construct a fully gauge-fixed lattice Hamiltonian for a pure SU(2) gauge theory. Our work extends upon previous work, where a formulation of an SU(2) lattice gauge theory was developed that is efficient to simulate at all values of the gauge coupling. That formulation utilized maximal-tree gauge, where all local gauge symmetries are fixed and a residual global gauge symmetry remains. By using the geometric picture of an SU(2) lattice gauge theory as a system of rotating rods, we demonstrate how to fix the remaining global gauge symmetry. In particular, the quantum numbers associated with total charge can be isolated by rotating between the lab and body frames using the three Euler angles. The Hilbert space in this new “sequestered” basis partitions cleanly into sectors with differing total angular momentum, which makes gauge-fixing to a particular total charge sector trivial, particularly for the charge-zero sector. In addition to this sequestered basis inheriting the property of being efficient at all values of the coupling, we show that, despite the global nature of the final gauge-fixing procedure, this Hamiltonian can be simulated using quantum resources scaling only polynomially with the lattice volume.

Lattice gauge theory↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Automated gauge reading and related systems, methods, and devices

Computing devices and methods for reading gauges are disclosed. A gauge reading method includes capturing image data corresponding to a captured image of one or more gauges, detecting one or more gauges in the captured image, cropping a detected gauge in the captured image to provide a use image including the detected gauge, and classifying the detected gauge to correlate the detected gauge with a template image. The gauge reading method also includes attempting to perform feature detection rectification on the use image to produce a rectified image of the detected gauge, performing template matching rectification on the use image to produce the rectified image responsive to a failure to perform the feature detection rectification, and estimating a gauge reading responsive to the rectified image. A computing device may implement at least a portion of a gauge reading method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum simulation of QED in Coulomb gauge

A recent work considered quantum simulation of Quantum Electrodynamics on a lattice in the Coulomb gauge with gauge degrees of freedom represented in the occupation basis in momentum space. In this work, we consider the more efficient representation of the gauge degrees of freedom in field basis in position space and develop a quantum algorithm for real-time simulation. We show that the continuum Coulomb gauge Hamiltonian is equivalent to the temporal gauge Hamiltonian when acting on physical states consisting of fermion and transverse gauge fields. The Coulomb gauge Hamiltonian is discretized by using the Green’s function of the discrete Laplacian operator under the Dirichlet boundary conditions. Both the continuum Coulomb gauge Hamiltonian and the discretized one proposed here guarantee that the unphysical longitudinal gauge fields are decoupled and commute with the corresponding Hamiltonian. Thus there is no need to impose any constraint. The local gauge field basis and the canonically conjugate variable basis are swapped efficiently using the quantum Fourier transform. We prove that the qubit cost to represent physical states and the gate count for real-time simulation scale polynomially with the lattice size, energy, time, accuracy, and Hamiltonian parameters in lattice units. The gate cost here for implementing the time evolution of the gauge field is reduced at least by a factor on the order of 10 8 for modest lattice size and accuracy level compared with the previous work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber-Optic Strain Gauge With High Resolution And Update Rate

An improved fiber-optic strain gauge is capable of measuring strains in the approximate range of 0 to 50 microstrains with a resolution of 0.1 microstrain. (To some extent, the resolution of the strain gauge can be tailored and may be extensible to 0.01 microstrain.) The total cost of the hardware components of this strain gauge is less than $100 at 2006 prices. In comparison with prior strain gauges capable of measurement of such low strains, this strain gauge is more accurate, more economical, and more robust, and it operates at a higher update rate. Strain gauges like this one are useful mainly for measuring small strains (including those associated with vibrations) in such structures as rocket test stands, buildings, oilrigs, bridges, and dams. The technology was inspired by the need to measure very small strains on structures supporting liquid oxygen tanks, as a way to measure accurately mass of liquid oxygen during rocket engine testing. This improved fiber-optic strain gauge was developed to overcome some of the deficiencies of both traditional foil strain gauges and prior fiber-optic strain gauges. Traditional foil strain gages do not have adequate signal-to-noise ratios at such small strains. Fiber-optic strain gauges have been shown to be potentially useful for measuring such small strains, but heretofore, the use of fiberoptic strain gauges has been inhibited, variously, by complexity, cost, or low update rate.

Figueroa, Fernando↗

Effects of Coatings on Water Intrusion and Strain Gauge Durability in Submerged Fatigue Conditions: Preprint

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand the combined effects of moisture intrusion and mechanical fatigue on marine energy structures, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Measuring strain is critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions was not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure, strains, and strain gauge failure modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite fatigue testing↗

So, How Much of the Earth's Surface Is Covered by Rain Gauges?

The measurement of global precipitation, both rainfall and snowfall, is critical to a wide range of users and applications. Rain gauges are indispensable in the measurement of precipitation, remaining the de facto standard for precipitation information across Earths surface for hydrometeorological purposes. However, their distribution across the globe is limited: over land their distribution and density is variable, while over oceans very few gauges exist and where measurements are made, they may not adequately reflect the rainfall amounts of the broader area. Critically, the number of gauges available, or appropriate for a particular study, varies greatly across the Earth owing to temporal sampling resolutions, periods of operation, data latency, and data access. Numbers of gauges range from a few thousand available in near real time to about 100,000 for all official gauges, and to possibly hundreds of thousands if all possible gauges are included. Gauges routinely used in the generation of global precipitation products cover an equivalent area of between about 250 and 3,000 sq m. For comparison, the center circle of a soccer pitch or tennis court is about 260 sq m. Although each gauge should represent more than just the gauge orifice, autocorrelation distances of precipitation vary greatly with regime and the integration period. Assuming each Global Precipitation Climatology Centre (GPCC) available gauge is independent and represents a surrounding area of 5-km radius, this represents only about 1% of Earths surface. The situation is further confounded for snowfall, which has a greater measurement uncertainty.

Rain gauge↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging

Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank hardware, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank harare, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the

Zimmerli, Gregory A.↗

Effects of Strain Gauge Coatings on Water Intrusion in Submerged Composite Coupon Testing

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand their combined effects, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Strain measurements are critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions is not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure (SGF), strains, and SGF modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The coatings did not have significant effects on composite fatigue life or strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Quantum error thresholds for gauge-redundant digitizations of lattice field theories

In the quantum simulation of lattice gauge theories, gauge symmetry can be either fixed or encoded as a redundancy of the Hilbert space. While gauge-fixing reduces the number of qubits, keeping the gauge redundancy can provide code space to mitigate and correct quantum errors by checking and restoring Gauss’s law. In this work, we consider the correctable errors for generic finite gauge groups and design the quantum circuits to detect and correct them. We calculate the error thresholds below which the gauge-redundant digitization with Gauss’s law error correction has better fidelity than the gauge-fixed digitization involving only gauge-invariant states. Our results provide guidance for fault-tolerant quantum simulations of lattice gauge theories. Published by the American Physical Society 2024

97 MATHEMATICS AND COMPUTING↗

Gauge invariance of light-matter interactions in first-principle tight-binding models

In this work, we study the different ways of introducing light-matter interaction in first-principle tight-binding (TB) models. The standard way of describing optical properties is the velocity gauge, defined by linear coupling to the vector potential. In finite systems a transformation to represent the electromagnetic radiation by the electric field instead is possible, albeit subtleties arise in periodic systems. The resulting dipole gauge is a multi-orbital generalization of the Peierls substitution. In this work we investigate the accuracy for both pathways, with particular emphasis on gauge invariance, for TB models constructed from maximally localized Wannier functions. This approach accurately captures the light-matter interaction close to the Fermi level. Focusing on paradigmatic two-dimensional materials, we construct first-principle models and calculate the response to electromagnetic fields in linear response and for strong excitations. Benchmarks against fully converged first-principle calculations allow for ascertaining the accuracy of the TB models. We find that the dipole gauge provides a more accurate description than the velocity gauge in all cases. The main deficiency of the velocity gauge is an imperfect cancellation of paramagnetic and diamagnetic current. Formulating a corresponding sum rule however provides a way to explicitly enforce this cancellation. This procedure corrects the TB models in the velocity gauge, yielding excellent agreement with dipole gauge and thus restoring gauge invariance.

2-dimensional systems↗

Anomaly inflow, dualities, and quantum simulation of Abelian lattice gauge theories induced by measurements

Previous work [] has demonstrated that quantum simulation of Abelian lattice gauge theories (Wegner models including the toric code in a limit) in general dimensions can be achieved by local adaptive measurements on symmetry-protected topological (SPT) states with higher-form generalized global symmetries. The entanglement structure of the resource SPT state reflects the geometric structure of the gauge theory. In this work we explicitly demonstrate the anomaly inflow mechanism between the deconfining phase of the simulated gauge theory on the boundary and the SPT state in the bulk by showing that the anomalous gauge variation of the boundary state obtained by bulk measurement matches that of the bulk theory. Moreover, we construct the resource state and the measurement pattern for the measurement-based quantum simulation of a lattice gauge theory with a matter field (Fradkin-Shenker model), where a simple scheme to protect gauge invariance of the simulated state against errors is proposed. We further consider taking an overlap between the wave function of the resource state for lattice gauge theories and that of a parameterized product state, and we derive precise dualities between partition functions with insertion of defects corresponding to gauging higher-form global symmetries, as well as measurement-induced phases where states induced by a partial overlap possess different (symmetry-protected) topological orders. Measurement-assisted operators to dualize quantum Hamiltonians of lattice gauge theories and their noninvertibility are also presented. Published by the American Physical Society 2024

Okuda, Takuya↗

Evaluation results of the 700 deg C Chinese strain gauges

Gauges fabricated from specially developed Fe-Cr-Al-V-Ti-Y alloy wire in the Republic of China were evaluated for use in static strain measurement of hot gas turbine engines. Gauge factor variation with temperature, apparent strain, and drift were included. Results of gauge factor versus temperature tests show gauge factor decreasing with increasing temperature. The average slope is -3-1/2 percent/100 K, with an uncertainty band of + or - 8 percent. Values of room temperature gauge factor for the Chinese and Kanthal A-1 gauges averaged 2.73 and 2.12, respectively. The room temperature gauge factor of the Chinese gauges was specified to be 2.62. The apparent strain data for both the Chinese alloy and Kanthal A-1 showed large cycle to cycle nonrepeatability. All apparent strain curves had a similar S-shape, first going negative and then rising to positive value with increasing temperatures. The mean curve for the Chinese gauges between room temperature and 100 K had a total apparent strain of 1500 microstrain. The equivalent value for Kanthal A-1 was about 9000 microstrain. Drift tests at 950 K for 50 hr show an average drift rate of about -9 microstrain/hr. Short-term (1 hr) rates are higher, averaging about -40 microstrain for the first hour. In the temperature range 700 to 870 K, however, short-term drift rates can be as high as 1700 microstrain for the first hour. Therefore, static strain measurements in this temperature range should be avoided.

Hobart, H. F.↗

The NASA Lewis Strain Gauge Laboratory: An update

Efforts continue in the development and evaluation of electrical resistance strain gauges of the thin film and small diameter wire type. Results obtained early in 1986 on some Chinese gauges and Kanthal A-1 gauges mounted on a Hastelloy-X substrate are presented. More recent efforts include: (1) the determination of the uncertainty in the ability to establish gauge factor, (2) the evaluation of sputtered gauges that were fabricated at Lewis, (3) an investigation of the efficacy of dual element temperature compensated gauges when using strain gauge alloys having large thermal coefficients of resistance, and (4) an evaluation of the practical methods of stabilizing gauges whose apparent strain is dependent on cooling rate (e.g., FeCrAl gauges).

Hobart, H. F.↗

Miniature Convection Cooled Plug-type Heat Flux Gauges

Tests and analysis of a new miniature plug-type heat flux gauge configuration are described. This gauge can simultaneously measure heat flux on two opposed active surfaces when heat flux levels are equal to or greater than about 0.2 MW/m(sup 2). The performance of this dual active surface gauge was investigated over a wide transient and steady heat flux and temperature range. The tests were performed by radiatively heating the front surface with an argon arc lamp while the back surface was convection cooled with air. Accuracy is about +20 percent. The gauge is responsive to fast heat flux transients and is designed to withstand the high temperature (1300 K), high pressure (15 MPa), erosive and corrosive environments in modern engines. This gauge can be used to measure heat flux on the surfaces of internally cooled apparatus such as turbine blades and combustors used in jet propulsion systems and on the surfaces of hypersonic vehicles. Heat flux measurement accuracy is not compromised when design considerations call for various size gauges to be fabricated into alloys of various shapes and properties. Significant gauge temperature reductions (120 K), which can lead to potential gauge durability improvement, were obtained when the gauges were air-cooled by forced convection.

Liebert, Curt H.↗

Use of multiple gauges and microwave attenuation of precipitation for satellite verification

In this paper both a microwave attenuation measurement along a horizontal line and multiple point gauge measurements are analyzed as possible ground-truth designs to validate satellite precipitation retrieval algorithms at the field of view spatial level (typically about 20 km). The design consists of comparing a sequence of pairs of contemporaneous measurements taken from the ground and from space. The authors examine theoretically the variance of expected differences between the two systems. The line average measurement leads to a smaller mean-square error compared to the case of a single point gauge, since some of the small-scale variability of the rain field is smoothed away by the line integration. The multiple point gauge measurements also give smaller mean-square error than that of a single point gauge. The centroid of the line and point gauge configurations are considered to be located randomly inside the field of view for different overpasses. A space-time spectral formalism is used with a noise-forced diffusive rain field to find the mean-square error. By considering instantaneous ground and satellite measurement pairs over about 50 visits when raining, we can reduce the expected error to approximately 10% of the standard deviation of climatological variability. This is considered to be a useful level of tolerance for identifying biases in the retrieval algorithms. It is found that the multiple point gauges (especially two gauges) are the economical ground-truth design compared to the microwave attenuation based on the mean-square error comparison. The major finding of this study is that a significant improvement over the point gauge is obtained by adding a single additional piece of information; adding more gauges or extending the line of attenuation is not an important improvement.

Ha, Eunho↗

Steady-State and Frequency Response of a Thin-Film Heat Flux Gauge

A new and simpler design of thin-film heat flux gauge has been developed for use In high-heat-flux environments. Heat flux gauges of the same design were fabricated on three different substrates and tested. The heat flux gauge comprises a thermopile and a thermocouple junction, which measures the surface temperature. The thermopile has 40 pairs of S-type thermocouples and is covered by two thermal resistance layers. Calibration and testing of these gauges were first carried out in an arc-lamp calibration facility. Sensitivity of the gauge was discussed in terms of the relative conductivity and surface temperature. The heat flux calculated from the gauge output was In good agreement with the precalibrated standard sensor. The steady-state and the transient response characteristics of the heat flux gauge were also investigated using a carbon dioxide pulse laser as a heat source. The dynamic frequency response was evaluated in terms of the nondimensional amplitude ratio with respect to the frequency spectrum of a chopped laser bcam. The frequency response of the gauge was determined to be about 3 kHz. The temperature profiles in the thin-film heat flux gauge were obtained numerically in steady-state conditions using FLUENT and compared with the experimental results.

Fralick, Gustave C.↗