Search NASA⌕ Search

SEARCH · Search NASA

Results for “Godiva”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

New constraint on the Np 237 ( n , γ ) Np 238 integral cross section using the Godiva-IV critical assembly

Accurate knowledge of the 237 Np(n, γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. Perform a model-independent measurement of the 237 Np(n, γ) 238 Np integral cross section using a well characterized fast neutron source and compare the result with previous measurements and current nuclear data evaluations. Provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np(n, γ) 238 Np reaction and an integral cross section of 342(11) mb was measured for the Godiva-IV neutron spectrum. Further, the 238 Np half-life has been measured with a result of 50.31(5) hours. The 237 Np(n, γ) 238 Np integral cross section measured in this work is in agreement with overlapping 1σ error bands to ENDF/B-VIII.0. However, the measured value is 3σ away from the calculated integral cross section using JENDL-5. This measurement offers a reliable benchmark for future 237 Np(n, γ) 238 Np cross section evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary of GNU Octave Lady Godiva Simulator

A pseudo real-time interactive reactor simulator for the Lady Godiva reactor has been developed using the GNU Octave software package. The simulator tracks the time-dependent power and fuel temperature behavior of the Lady Godiva reactor during sub-prompt critical transients. Users interact with the simulator by controlling reactivity input. This input occurs through users repositioning a control rod as desired during simulator operation. Various reactor parameters are displayed graphically in near “real time,” facilitating user assessment and feedback input. The reactor model consists of a lumped-fuel core, a single control rod, and a simple heat transfer mechanism that allows heat to be rejected from the core. The goal of the simulator is to demonstrate in real-time the system response to reactivity perturbations, the effect of reactivity feedback, and the effect of temperature-dependent equilibrium conditions. The dynamic behavior of the reactor is primarily driven by the relative characteristic time-constants between the delayed neutrons and the overall heat transfer parameter. The simulator will allow users to gain experience performing standard reactor operations, such as establishing steady-state at different fuel temperatures and making power level changes

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Yield and PDV Measurements of the Godiva-IV Critical Assembly (Preliminary Report)

A high dynamic range, scinillator based detector, the MHD-240, was used to measure the gamma and neutron flux of several prompt critical bursts of the Godiva-IV assembly. The measurements provided the alpha and FWHM for several different burst temperatures. Calibrations of the MHD240 gamma and neutron sensitivity along with MCNP based simulation of the Godiva-IV assembly will allow us to also determine the total fission yield of the burst integrated over approximately 5 ms. Work is ongoing to check the calibrations of the MHD-240, and improve the MCNP simulations. This is a preliminary report, and the fission yields reported here are not final and are likely inaccurate. The measured alpha and FWHM are not impacted by the calibration issues and are considered final.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiment Logistics for an International Blind Intercomparison Exercise for Nuclear Accident Dosimetry at Godiva-IV

This document is the Experimental Set-up and Design (CED-3A) Report for IER-538, “Full Dosimetry Exercise Around Godiva Reactors” The report discusses the structure of the exercise consisting of two critical excursions, identifying the participating laboratories and their points of contact. The report also includes details of all dosimetry each laboratory will submit to be placed in proximity to Godiva-IV on aluminum plates or BOMAB phantoms. Each laboratory list the counting and spectroscopy equipment to be utilized at the LLNL NAD Laboratory in Mercury. The exercise is tentatively scheduled for one week in fiscal year 2022.

61 RADIATION PROTECTION AND DOSIMETRY↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva-IV Critical Assembly [Slides]

Objectives: Familiarization of the Godiva-IV assembly; Understand the criticality safety parameters that effect Godiva IV; Understand the differences between subcritical, delayed-critical, and prompt-critical operations; and, Understand the concept of temperature-dependent reactivity feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva IER268 PDV Measurements

PowerPoint slides providing a quick-look of photon Doppler velocimetry (PDV) data taken during a series bursts using the Godiva machine located at the NNSS Device Assembly Facility. Vibrations, or ringing, of approximately 7.2 to 7.8 kHz were observed.

47 OTHER INSTRUMENTATION↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

The Y-12 National Security Complex and the Uranium Processing Facility (UPF) selected the Mirion CAAS-3S as the Criticality Accident Alarm System for UPF and for Y-12 facilities replacing their legacy CAAS as part of efforts to extend the facility lifespans. As part of this process, the CAAS-3S system was exposed to a high radiation dose and dose rate during reactor testing with the Godiva-IV fast burst reactor. The reactor testing was designed around preliminary analyses that determined Y-12 and UPF requirements, and simulations of the radiation field within the reactor facility were used to determine reactor operating parameters, CAAS equipment locations, and the design of a neutron shield wall. This paper presents the design and results of the testing, and discusses how the test results were interpreted by criticality safety engineers at Y-12 and UPF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV Burst Reproducibility and Diagnostic Testing

Godiva IV is a fast burst critical assembly located at the Nation Criticality Experiment Research Center (NCERC) in the Nevada National Security Site (NNSS). It is constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. The assembly can be operated at delayed critical or can be used to perform super-prompt critical bursts with temperature rises of up to 250 °C. Several projects with the objective of characterizing Go diva IV are ongoing including characterizations of its radiation emission and thermomechanics. One of the characterization projects is a study of the variability in the relative source emission (or fluence in absolute terms) between bursts that are nominally the same size. There is some inherent variation in the number of fissions, or "size" of the burst, even for bursts where the operators perform identical processes. The source of the variation can be attributed to several factors. The largest contributor is the precision with which the operators are able to determine delayed critical (DC). Operators find DC for every burst operation. The impact of being slightly above or below DC can change the super-prompt critical reactivity and therefore the source term. The temperature of the fuel is another factor. Establishing delayed critical prior to performing a burst act as a control of the bulk temperature coefficient of reactivity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Shielding Benchmarks Using the Godiva IV Assembly

The Nuclear Criticality Safety Program (NCSP) is developing a shielding benchmark using the Godiva IV assembly as a source. Its present status is reviewed herein. Even eight decades into the nuclear era, substantial work remains to develop a database of shielding benchmarks to support future nuclear development. A nuclear simulation is only as good as its supporting data, inputs, and validation basis. Uncertainty in these areas is addressed using conservatism, which adds margin and, occasionally, cost. In many shielding situations, high accuracy is not necessary because additional material is not particularly expensive. After all, 1–2 cm of lead often reduces the gamma ray dose substantially. However, in certain areas, conservatism can add unnecessary cost. These areas include mobile shielding applications such as casks, ships, microreactors, and spacecraft, where weight and, thus, margin is expensive. Although these characteristics are side benefits for NCSP shielding benchmark development, the main driver is enabling more reliable placement of criticality accident alarm systems (CAASs) in nuclear material facilities, such as those dedicated to the production of advanced reactor fuels. CAAS placement relies on more than accurate data and code validation. It also relies on sufficiently accurate materials specifications, geometry specifications, and a well-defined, alarm-producing baseline accident. All these things require tacit knowledge and understanding of the problem being evaluated. Benchmarks can help ensure this understanding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

237 Np Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 237 Np. Fission was induced in a NpO 2 (NO 3 ) target using the Godiva IV critical assembly in burst mode. The irradiated sample was transferred to a high-resolution γ-ray detection setup within 50 minutes. γ-ray list mode data was collected from 50 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. Finally, the initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

239 Pu Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 239 Pu. Fission was induced in a pure 239 Pu (>99%) target using the Godiva IV critical assembly in burst mode. Further, the irradiated sample was transferred to a high-resolution γ-ray detector within 45 minutes. γ-ray list mode data was collected from 45 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. The initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 557: Godiva IV Reproducibility/Characterization [Slides]

The primary goal of the IER 557 Godiva IV reproducibility/characterization process is to determine reproducibility for 70°C bursts. The secondary goal is to characterize the radiation field, including absolute calibration with radchem counting of fission foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 538: International Dosimetry Intercomparison Exercise with Godiva-IV [Slides]

Presentation on International Dosimetry Intercomparison Exercise with Godiva-IV. This presentation details Department of Energy (DOE) requirements and irradiation. Graphs show Neutron dose conversion factors, Neutron dose characterization, and Photon dose characterization. Results of 2m, 3m, and 4m tests are then compared to DOE standards. Findings show photon dose measurements were limited by instrumentation not available. Additionally, there has been a turnover of staff in dosimetry. However, funding is being provided for Universal Nuclear Accident Dosimeter (U-NAD).

61 RADIATION PROTECTION AND DOSIMETRY↗

Godiva-IV Critical Assembly [Slides]

The objectives of this presentation are to: (1) gain awareness of the Godiva-IV assembly, including its design and intent; (2) create familiarization of the differences between subcritical, delayed-critical, and prompt-critical; and (3) observe the effects of temperature-dependent reactivity feedback.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗