Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid error indicator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Computing confidence intervals on solution costs for stochastic grid generation expansion problems.

A range of core operations and planning problems for the national electrical grid are naturally formulated and solved as stochastic programming problems, which minimize expected costs subject to a range of uncertain outcomes relating to, for example, uncertain demands or generator output. A critical decision issue relating to such stochastic programs is: How many scenarios are required to ensure a specific error bound on the solution cost? Scenarios are the key mechanism used to sample from the uncertainty space, and the number of scenarios drives computational difficultly. We explore this question in the context of a long-term grid generation expansion problem, using a bounding procedure introduced by Mak, Morton, and Wood. We discuss experimental results using problem formulations independently minimizing expected cost and down-side risk. Our results indicate that we can use a surprisingly small number of scenarios to yield tight error bounds in the case of expected cost minimization, which has key practical implications. In contrast, error bounds in the case of risk minimization are significantly larger, suggesting more research is required in this area in order to achieve rigorous solutions for decision makers.

09 BIOMASS FUELS↗

Minimising the error in eigenvalue calculations involving the Boltzmann transport equation using goal-based adaptivity on unstructured meshes

This article presents a method for goal-based anisotropic adaptive methods for the finite element method applied to the Boltzmann transport equation. The neutron multiplication factor, k{sub eff}, is used as the goal of the adaptive procedure. The anisotropic adaptive algorithm requires error measures for k{sub eff} with directional dependence. General error estimators are derived for any given functional of the flux and applied to k{sub eff} to acquire the driving force for the adaptive procedure. The error estimators require the solution of an appropriately formed dual equation. Forward and dual error indicators are calculated by weighting the Hessian of each solution with the dual and forward residual respectively. The Hessian is used as an approximation of the interpolation error in the solution which gives rise to the directional dependence. The two indicators are combined to form a single error metric that is used to adapt the finite element mesh. The residual is approximated using a novel technique arising from the sub-grid scale finite element discretisation. Two adaptive routes are demonstrated: (i) a single mesh is used to solve all energy groups, and (ii) a different mesh is used to solve each energy group. The second method aims to capture the benefit from representing the flux from each energy group on a specifically optimised mesh. The k{sub eff} goal-based adaptive method was applied to three examples which illustrate the superior accuracy in criticality problems that can be obtained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

1-D coupled surface flow and transport equations revisited via the physics-informed neural network approach

The de Saint-Venant equation (SVE) and advection–diffusion equation (ADE) are commonly employed to solve solute transport problems in surface water. In this work, we propose a mesh-free method based on the physics-informed neural network (PINN) to solve the one dimensional (1-D) SVE, ADE, and the coupled SVE and ADE (SVE-ADE) under various initial and boundary conditions. The PINN model extends the architecture of deep neural networks (DNNs) with implementation of loss function, which are additionally subject to constraints imposed by the physical laws of SVE and ADE, along with their initial and boundary conditions. In such a manner, PINNs can be quickly steered to the true solution while obeying the physical laws. The results of PINN model are compared with the analytical and/or numerical solutions under various conditions to investigate its accuracy and efficiency in solving the SVE, ADE, and SVE-ADE. Our results indicate PINN can accurately simulate the shock wave morphology and avoid numerical dissipation in unsteady flow condition. The PINN method outweighed traditional numerical methods in several aspects, including its ability to function with small amounts of data, no grid discretization, and random selection of sampling points, etc. Additionally, the PINN method is also suitable for solving inverse problems with sparse and noisy data. With 1% noise and 2000 initial and boundary condition points (N u ), the errors of the estimated flow rate (v) and diffusion coefficient (D) are 0.003% and 0.105%, respectively, which indicate the accuracy and robustness of the proposed method. Finally, our results indicate the capability and robustness of the proposed PINN methodology for solving multi-physics problems, irrespective of the presence of sparse and noisy data in the training dataset.

54 ENVIRONMENTAL SCIENCES↗

Probabilistic Risk Assessment of CO2 Trapping Mechanisms in a Sandstone CO2-EOR Field in Northern Texas, USA

This study employs a polynomial chaos expansion (PCE) technique to develop the reduced order models (ROMs) integrated with the Monte Carlo simulations to quantify uncertainties of CO 2 storage associated with enhanced oil recovery (EOR) in a commercial-scale CO 2 -EOR field. The Morrow B sandstone at the Farnsworth Unit (FWU) EOR field in northern Texas was selected as a case study. A 3-D reservoir model, including simulation of a five-spot injection/production well pattern, was constructed based on the data from well logs and cores, and an updated seismic interpretation in the FWU. Porosity and permeability were considered as sources of uncertainty. The 1000-realization heterogeneous random fields of porosity and permeability were generated based on the variogram analysis on the core measurements of the FWU. Three model outputs of interest include the amount of CO 2 trapped by three trapping mechanisms, i.e. hydrodynamic trapping, oil dissolution trapping, and aqueous dissolution trapping. The total of 25 runs were conducted with the simulations of a 20-year CO 2 -EOR period, and a 20-year monitoring period to develop the ROMs between uncertain model input parameters (i.e., porosity and permeability in this study) and model outputs at the end of simulation for each grid cell using PCE approach. The high coefficient of determination (R 2 ) and small normalized root mean square error (NRMSE) between the simulated (using reservoir modeling) and predicted (using ROMs) CO 2 storage indicate that the ROMs are acceptable and reliable to be used for the predictions. Given the 1000 Monte Carlo samplings of the model input parameters, cumulative distribution functions (CDFs) and uncertainty bounds (10 th and 90 th percentiles) of model outputs were estimated based on ROMs. At the end of simulation, the most injected CO 2 at the FWU was stored by hydrodynamic trapping (between 121,400 and 166,860 tonnes), followed by oil dissolution trapping (between 55,303 and 76,816 tonnes), and aqueous dissolution trapping (between 1979 and 2751 tonnes).

58 GEOSCIENCES↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategies for hp-adaptive Refinement

In the hp-adaptive version of the finite element method for solving partial differential equations, the grid is adaptively refined in both h, the size of the elements, and p, the degree of the piecewise polynomial approximation over the element. The selection of which elements to refine is determined by a local a posteriori error indicator, and is well established. But the determination of whether the element should be refined by h or p is still open. In this paper, we describe several strategies that have been proposed for making this determination. A numerical example to illustrate the effectiveness of these strategies will be presented.

97 MATHEMATICS AND COMPUTING↗

Impact on Modeled Cloud Characteristics Due to Simplified Treatment of Uniform Cloud Condensation Nuclei During NEAQS 2004

Subgrid-scale cloud condensation nuclei (CCN) heterogeneity is not represented in global climate models (GCM) and potentially contributes systematic errors to simulated cloud effects. High-resolution mesoscale model simulations were performed to investigate the impact of assuming a uniform CCN distribution on cloud properties and surface radiation over a region the size of a GCM grid column. Results indicate that a prescribed CCN distribution allowing for vertical and temporal fluctuations does substantially better in simulating cloud properties and radiative effects than does a prescribed uniform and constant CCN distribution. Spatially and temporally averaged net effects on downwelling shortwave radiation are between -3 and -11 W m-2 for the fluctuating and uniform distributions, respectively, versus a control simulation with fully interactive aerosols. Both prescribed CCN distributions produce optically thicker clouds more often than the control, with the mean cloud optical depth increasing by over 25% when using the uniform and constant CCN distribution.

54 ENVIRONMENTAL SCIENCES↗

A High-resolution Regional Wave Resource Characterization For The U.S. West Coast

Objectives/Scope: Wave resource characterization is a critical step for wave energy converter deployment in the coastal ocean and relies on long-term, high-resolution wave datasets. This study presents a detailed modeling study of the wave resource along the U.S. West Coast (Washington, Oregon, and California), a coastal region that was identified with high wave energy potential in earlier studies. Methods, Procedures, Process: The wave hindcast covers a 32-year period from 1979 to 2010 and is based on a multi-resolution, unstructured-grid SWAN model framework. Model configuration closely follows and meets the requirements recommended by the International Electrotechnical Commission Technical Specification (IEC TS) for wave energy resource assessment and characterization (Class 2 - feasibility study). The model domain covers the entire U.S. Exclusive Economic Zone (EEZ) in the West Coast and has a spatial resolution varying from ~300 m in the nearshore region (20 km from the shoreline) to ~2500 m within the EEZ and ~5000 m at the open boundary, which extends beyond the EEZ. The model was forced by hourly 2-D wave spectra produced by a two-way nested WaveWatch III model, which covers the global ocean domain and the broader U.S. West Coast region domain with spatial resolutions of 0.5 degree and 10 arc-minutes, respectively. Both wave models are forced by hourly, 0.5-degree wind forcing obtained from NCEP’s Climate Forecast System Reanalysis (CFSR) product. Results, Observations, Conclusions: The standard model output for the SWAN model includes 3-hourly output for the six IEC wave resource parameters (e.g., omnidirectional wave power) at each grid point and hourly 2-D spectra at more than 50 NDBC buoys. Extensive model validation was achieved by comparing the six model-predicted IEC parameters with those derived from field observations at representative NDBC buoys. The error statistics indicated the model’s satisfactory performance. Further analyses were conducted to systematically evaluate the temporal and spatial distributions of wave energy potential and wave climate along the U.S. West Coast. Results suggest that Washington and Oregon coasts have similar nearshore wave resource, which is significantly higher than resources in Southern California. Strong seasonal variations are also observed, e.g., high wave energy tends to occur in the winter months. In summary, this study produced the first high-resolution, comprehensive dataset on wave energy distribution along the U.S. West Coast. Novel/Additive Information: The results are being used by the National Renewable Energy Laboratory to update the MHK Atlas, which was originally derived from NOAA’s 4-arc-minute WaveWatch III model output. In addition, the monthly averaged wave energy climatology dataset can be readily shared to support a variety of research and application efforts within the EEZ of the U.S. West Coast.

Wang, Taiping↗

Evaluation of CMIP6 models in simulating the statistics of extreme precipitation over Eastern Africa

We report the Eastern Africa region experiences frequent extreme precipitation events that can cause destruction of property and environment, and loss of lives. Thus, there is a need to understand how these events may change in the future and how well the global climate models that are used to make projections can simulate precipitation extremes in this region before they can be used in downscaling or flood and drought impact assessment studies. In this work, we evaluated the ability of sixteen Coupled Model Intercomparison Project Phase 6 (CMIP6) models to simulate present-day precipitation extremes over the Eastern Africa region during the two rainy seasons (March–May and September–November). We used nine extreme precipitation indices (including seven (one) indices of wet (dry) extremes) defined by the Expert Team on Climate Change Detection and Indices. The CMIP6 models were evaluated against two gridded observation datasets: Global Precipitation Climatology Project One-Degree Daily Dataset and Tropical Rainfall Measuring Mission Multi-satellite Precipitation Analysis 3B42. Three model performance metrics (percentage bias, normalized root-mean-square error, and pattern correlation coefficient) were employed to further assess the strengths and weakness of the models. Our results show that the multi-model ensemble mean generally provides a better representation of observed precipitation and related extremes compared to individual models when considering all metrics and seasons. Several consistent biases are evident across CMIP6 models, which tend to overestimate the total-wet day precipitation and consecutive wet days, and underestimate very wet days and maximum 5-day precipitation in both seasons. Furthermore, no single model consistently performs best, model performance varies with the season and index under consideration and is generally independent of horizontal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many preclinical applications including focused drug delivery and thermal therapy. Funding support provided by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

An adaptive local reduced basis method for solving PDEs with uncertain inputs and evaluating risk

Many physical systems are modeled using partial differential equations (PDEs) with uncertain or random inputs. For such systems, naively propagating a fixed number of samples of the input probability law (or an approximation thereof) through the PDE is often inadequate to accurately quantify the "risk" associated with critical system responses. In this paper, we develop a goal-oriented, adaptive sampling and local reduced basis approximation for PDEs with random inputs. Our method determines a set of samples and an associated (implicit) Voronoi partition of the parameter domain on which we build local reduced basis approximations of the PDE solution. The samples are selected in an adaptive manner using an a posteriori error indicator. A notable advantage of the proposed approach is that the computational cost of the approximation during the adaptive process remains constant. We provide theoretical error bounds for our approximation and numerically demonstrate the performance of our method when compared to widely used adaptive sparse grid techniques. In addition, we tailor our approach to accurately quantify the risk of quantities of interest that depend on the PDE solution. We demonstrate our method on an advection-diffusion example and a Helmholtz example. Keywords: stochastic partial differential equation, adaptive sampling, reduced basis, a posteriori error estimation, coherent risk measure, conditional value-at-risk.

42 ENGINEERING↗

An Efficient, Globally Convergent Method for Optimization Under Uncertainty Using Adaptive Model Reduction and Sparse Grids

We present a new approach to efficiently solve optimization problems constrained by partial differential equations (PDEs) with uncertain coefficients. The method leverages two sources of inexactness that trade accuracy for speed: (1) stochastic collocation based on dimension-adaptive sparse grids (SGs), which approximates the stochastic objective function with a limited number of quadrature nodes, and (2) projection-based reduced-order models (ROMs), which generate efficient approximations to PDE solutions. These two sources of inexactness lead to inexact objective function and gradient evaluations, which are managed by a trust-region method that guarantees global convergence by adaptively refining the SG and ROM until a proposed error indicator drops below a tolerance specified by trust-region convergence theory. A key feature of the proposed method is that the error indicator---which accounts for errors incurred by both the SG and ROM---must be only an asymptotic error bound, i.e., a bound that holds up to an arbitrary constant that need not be computed. This allows the approach to be applicable to a wide range of problems, including those where sharp, computable error bounds are not available; this distinguishes the proposed method from previous works. Numerical experiments performed on a model problem from optimal flow control under uncertainty verify global convergence of the method and demonstrate the method's ability to outperform previously proposed alternatives.

97 MATHEMATICS AND COMPUTING↗

A parallel p ‐adaptive discontinuous Galerkin method for the Euler equations with dynamic load‐balancing on tetrahedral grids

Abstract A novel p ‐adaptive discontinuous Galerkin (DG) method has been developed to solve the Euler equations on three‐dimensional tetrahedral grids. Hierarchical orthogonal basis functions are adopted for the DG spatial discretization while a third order TVD Runge‐Kutta method is used for the time integration. A vertex‐based limiter is applied to the numerical solution in order to eliminate oscillations in the high order method. An error indicator constructed from the solution of order and is used to adapt degrees of freedom in each computational element, which remarkably reduces the computational cost while still maintaining an accurate solution. The developed method is implemented with under the Charm++ parallel computing framework. Charm++ is a parallel computing framework that includes various load‐balancing strategies. Implementing the numerical solver under Charm++ system provides us with access to a suite of dynamic load balancing strategies. This can be efficiently used to alleviate the load imbalances created by p ‐adaptation. A number of numerical experiments are performed to demonstrate both the numerical accuracy and parallel performance of the developed p ‐adaptive DG method. It is observed that the unbalanced load distribution caused by the parallel p ‐adaptive DG method can be alleviated by the dynamic load balancing from Charm++ system. Due to this, high performance gain can be achieved. For the testcases studied in the current work, the parallel performance gain ranged from 1.5× to 3.7×. Therefore, the developed p ‐adaptive DG method can significantly reduce the total simulation time in comparison to the standard DG method without p ‐adaptation.

97 MATHEMATICS AND COMPUTING↗

Geothermal Uncertainty Representation in reV: the Renewable Energy Potential Model

We present a preliminary methodology for including geothermal resource uncertainty into the Renewable Energy Potential model, which estimates potential capacity and costs on a gridded surface at the national scale. The uncertainty outputs characterize the 10th, 50th and 90th percentile for geothermal resources using two energy capacity estimation equations. We then present a method and results that demonstrate how other geologic data layers, which may be indicative of permeability, can be used to inform the mean and standard deviation of the geothermal capacity. We demonstrate how the mean and standard deviation can be defined or partially informed by using collocated regression estimates and estimate errors, respectively . These regression results are from 36 observed geothermal power plants in the Great Basin region and are also used to benchmark the P10-P90 calculations.

exclusions↗

USING TIME VARIANT VOLTAGE TO CALCULATE ENERGY CONSUMPTION AND POWER USE OF BUILDING SYSTEMS

Buildings are the main consumers of electricity across the world. However, in the research and studies related to building performance assessment, the focus has been on evaluating the energy efficiency of buildings whereas the instantaneous power efficiency has been overlooked as an important aspect of total energy consumption. As a result, we never developed adequate models that capture both thermal and electrical characteristics (e.g., voltage) of building systems to assess the impact of variations in the power system and emerging technologies of the smart grid on buildings energy and power performance and vice versa. This paper argues that the power performance of buildings as a function of electrical parameters should be evaluated in addition to systems’ mechanical and thermal behavior. The main advantage of capturing electrical behavior of building load is to better understand instantaneous power consumption and more importantly to control it. Voltage is one of the electrical parameters that can be used to describe load. Hence, voltage dependent power models are constructed in this work and they are coupled with existing thermal energy models. Lack of models that describe electrical behavior of systems also adds to the uncertainty of energy consumption calculations carried out in building energy simulation tools such as EnergyPlus, a common building energy modeling and simulation tool. To integrate voltage-dependent power models with thermal models, the thermal cycle (operation mode) of each system was fed into the voltage-based electrical model. Energy consumption of systems used in this study were simulated using EnergyPlus. Simulated results were then compared with estimated and measured power data. The mean square error (MSE) between simulated, estimated, and measured values were calculated. Results indicate that estimated power has lower MSE when compared with measured data than simulated results. Results discussed in this paper will illustrate the significance of enhancing building energy models with electrical characteristics. This would support different studies such as those related to modernization of the power system that require micro scale building-grid interaction, evaluating building energy efficiency with power efficiency considerations, and also design and control decisions that rely on accuracy of building energy simulation results.

Makhmalbaf, Atefe↗

Foresee: A user-centric home energy management system for energy efficiency and demand response

This paper presents foresee, a user-centric home energy management system that can help optimize how a home operates to concurrently meet users' needs, achieve energy efficiency and commensurate utility cost savings, and reliably deliver grid services based on utility signals. Foresee is built on a multiobjective model predictive control framework, wherein the objectives consist of energy cost, thermal comfort, user convenience, and carbon emission. Foresee learns user preferences on different objectives and acts on their behalf to operate building equipment, such as home appliances, photovoltaic systems, and battery storage. In this work, machine-learning algorithms were used to derive data-driven appliance models and usage patterns to predict the home's future energy consumption. This approach enables highly accurate predictions of comfort needs, energy costs, environmental impacts, and grid service availability. Simulation studies were performed on field data from a residential building stock data set collected in the Pacific Northwest. Results indicated that foresee generated up to 7.6% whole-home energy savings without requiring substantial behavioral changes. When responding to demand response events, foresee was able to provide load forecasts upon receipt of event notifications and delivered the committed demand response services with 10% or fewer errors. Foresee fully utilized the potential of the battery storage and controllable building loads and delivered up to 7.0-kW load reduction and 13.5-kW load increase. As a result, these benefits are provided while maintaining the occupants' thermal comfort or convenience in using their appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗