Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NLS cycle 1 and NLS 2 base heating technical notes. Appendix 3: Preliminary cycle 1 NLS base heating environments. Cycle 1 NLS base heating environments. NLS 2 650K STME base heating environments

A preliminary analysis of National Launch System ascent plume induced base heating environments has been completed to support the Induced Environments Panel's objective to assist in maturing the NLS vehicle (1.5 stage and heavy launch lift vehicle) design. Environments during ascent have been determined from this analysis for a few selected locations on the engine nozzles and base heat shield for both vehicles. The environments reflect early summer 1991 configurations and performance data and conservative methodology. A more complete and thorough analysis is under way to update these environments for the cycle 1 review in January 1992.

Bender, Robert L.↗

Effect of nonaxisymmetric magnetic perturbations on divertor heat and particle flux profiles in National Spherical Torus Experiment

Small, nonaxisymmetric magnetic perturbations generated by external coils have been found to break the axisymmetry of heat and particle flux deposition pattern in the divertor area in the National Spherical Torus Experiment (NSTX). This breaking by the applied 3-D field causes strike point splitting that is represented as local peaks and valleys in the divertor profiles. In case of n = 3 fields application, the broken toroidal symmetry of the divertor profile shows 120 deg. of spatial periodicity while data for n = 1 fields provide a fully nonaxisymmetric heat and particle deposition. Field line tracing showed good agreement with the measured heat and particle flux profiles. Higher toroidal mode number (n = 3) of the applied perturbation produced more and finer striations in the divertor profiles than in the lower mode number (n = 1) case. Following the previous result of the intrinsic strike point splitting by the n = 3 error fields [Nucl. Fusion 50, 045010 (2010); J. Nucl. Mater. (2011), doi:10.1016/j.jnucmat.2011.01.115], result of the connection length profile from field line tracing identifies intrinsic error field as a possible source of the intrinsic splitting. In determining the strike point splitting pattern, q{sub 95} is found to play an important role; higher q{sub 95} produces finer striations and induces higher fraction of heat flux to flow through the split strike point channels. Higher pedestal electron collisionality also made the striations in the D{sub {alpha}} profile more pronounced in the given range of collisionality variation. The radial location of local peaks in the profiles during the triggered edge localized modes (ELMs) by the applied n = 3 fields stays similar before and after the application. This shows that the heat flux from the triggered ELMs follows the mode number of the applied perturbation. The external magnetic perturbation can reattach detached divertor plasma, but this can be overcome by detaching the plasma with additional divertor gas puffing.

36 MATERIALS SCIENCE↗

The impact of TXV heating on the performance of air-source heat pump in heating mode

The paper discusses the strategy of TXV heating, which adds a limited amount of heat on the surface of TXV sensor, to achieve energy saving and low cost in air-source heat pumps. The TXV heating is able to retard the valve closing so as to boost energy saving in heating mode. The testing results demonstrate the appropriate TXV heating achieves a remarkable improvement in COP and thermal comfort. The required heating power is not more than 40w. The additional equipment cost of TXV heating is less than $20. Thus, the strategy of TXV heating is practical from the view of technology and economy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operational Performance Characterization of a Heat Pump System Utilizing Recycled Water as Heat Sink and Heat Source in a Cool and Dry Climate

The wastewater leaving from homes and businesses contains abundant low-grade energy, which can be utilized through heat pump technology to heat and cool buildings. Although the energy in the wastewater has been successfully utilized to condition buildings in other countries, it is barely utilized in the United States, until recently. In 2013, the Denver Museum of Nature & Science at Denver, the United States implemented a unique heat pump system that utilizes recycled wastewater from a municipal water system to cool and heat its 13,000 m 2 new addition. This recycled water heat pump (RWHP) system uses seven 105 kW (cooling capacity) modular water-to-water heat pumps (WWHPs). Each WWHP uses R-410A refrigerant, has two compressors, and can independently provide either 52 °C hot water (HW) or 7 °C chilled water (CHW) to the building. This paper presents performance characterization results of this RWHP system based on the measured data from December 2014 through August 2015. The annual energy consumption of the RWHP system was also calculated and compared with that of a baseline Heating, Ventilation, and Air Conditioning (HVAC) system which meets the minimum energy efficiencies that are allowed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1-2013. The performance analysis results indicate that recycled water temperatures were favorable for effective operation of heat pumps. As a result, on an annual basis, the RWHP system avoided 50% of source energy consumption (resulting from reduction in natural gas consumption although electricity consumption was increased slightly), reduced CO 2 emissions by 41%, and saved 34% in energy costs as compared with the baseline system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A study of circumferentially-heated and block-heated heat pipes. I - Experimental analysis and generalized analytical prediction of capillary limits. II - Three-dimensional numerical modeling as a conjugate problem

The wall and centerline vapor temperatures and heat output are determined experimentally for a low-temperature copper-water heat pipe under uniform circumferential heating and block heating. The time required to reach a vapor temperature of 60 C from an initial ambient temperature of 21 C is determined for both modes of heating. The experimental capillary limit of the heat pipe is compared to the generalized capillary limits for block-heated pipes over a range of vapor temperatures. A three-dimensional numerical model is then developed for determining the temperature, pressure, and velocity distributions in the entire domain of a circumferentially heated and a block-heated pipe. The problem is formulated as a conjugate problem, without the assumption of a uniform vapor temperature. The predictions of the model are found to be in good agreement with the experimental data.

Schmalhofer, Joseph↗

Electron heating in low pressure capacitive discharges revisited

The electrons in capacitively coupled plasmas (CCPs) absorb energy via ohmic heating due to electron-neutral collisions and stochastic heating due to momentum transfer from high voltage moving sheaths. We use Particle-in-Cell (PIC) simulations to explore these heating mechanisms and to compare the PIC results with available theories on ohmic and stochastic heating. The PIC results for ohmic heating show good agreement with the ohmic heating calculation of Lafleur et al. [Phys. Plasmas 20, 124503 (2013)]. The PIC results for stochastic heating in low pressure CCPs with collisionless sheaths show good agreement with the stochastic heating model of Kaganovich et al. [IEEE Trans. Plasma Sci. 34, 696 (2006)], which revises the hard wall asymptotic model of Lieberman [IEEE Trans. Plasma Sci. 16, 638 (1988)] by taking current continuity and bulk oscillation into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessments of advanced reactor heat supply to high temperature industrial unit operations: Heat Engines and Heat Pumps

In this report, the feasibility of employing Advanced Nuclear Reactors to supply the necessary high-quality heat to Industrial Processes is investigated. As a first step, the most relevant industrial applications that could benefit from this coupling were identified. Four industries including petroleum refining (distillation, catalyst regeneration, hydro-steam cracking), chemical polymers, steel manufacturing (metals annealing/soaking) and cement manufacturing (calcination of limestone and dolomite industries) were considered. An overview of the heat duties, i.e., the temperatures and thermal powers required by representative plants of the different processes, was provided. Secondly, the thermodynamic conditions of the steam produced by representative designs of Advanced Reactor concepts (Liquid Metal Fast Breeder Reactors, Molten Salt Reactors, and High Temperature Gas-cooled Reactors) were summarized. The comparison between the requirements of the industrial processes and the capabilities of the candidate nuclear power plants showed that only a few processes could benefit from the coupling. Although Advanced Reactors operate at higher temperatures than Light Water Reactors, the thermodynamic conditions of the generated steam flow rates are generally not suitable for the selected applications. At the same time, data indicate that most of the processes can be suitably supplied if the temperature of steam is elevated to 900 °C. One possible solution to boost the quality of the steam from the nuclear island involves the use of a heat pump. Based on a technology similar to that found in refrigerators and air conditioners, heat pumps extract heat from a source, elevate its temperature and transfer it to where it is needed. A simple numerical example illustrating the viability of this method is described. Specifically, the energy conversion cycle of a conventional Pressurized Water Reactor was extended to incorporate a compressor to raise the heating value of the steam produced by the reactor. Two reference configurations, i.e., one where the industrial process coupled to the nuclear power plant exhausts saturated liquid and the other where it exhausts saturated steam, were considered. The thermal efficiencies achievable by increasing the heating value of the reactor steam in this way are significantly greater than by direct electric heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimation of Surface Temperature and Heat Flux by Inverse Heat Transfer Methods Using Internal Temperatures Measured While Radiantly Heating a Carbon/Carbon Specimen up to 1920 F

The ability to solve the heat conduction equation is needed when designing materials to be used on vehicles exposed to extremely high temperatures; e.g. vehicles used for atmospheric entry or hypersonic flight. When using test and flight data, computational methods such as finite difference schemes may be used to solve for both the direct heat conduction problem, i.e., solving between internal temperature measurements, and the inverse heat conduction problem, i.e., using the direct solution to march forward in space to the surface of the material to estimate both surface temperature and heat flux. The completed research first discusses the methods used in developing a computational code to solve both the direct and inverse heat transfer problems using one dimensional, centered, implicit finite volume schemes and one dimensional, centered, explicit space marching techniques. The developed code assumed the boundary conditions to be specified time varying temperatures and also considered temperature dependent thermal properties. The completed research then discusses the results of analyzing temperature data measured while radiantly heating a carbon/carbon specimen up to 1920 F. The temperature was measured using thermocouple (TC) plugs (small carbon/carbon material specimens) with four embedded TC plugs inserted into the larger carbon/carbon specimen. The purpose of analyzing the test data was to estimate the surface heat flux and temperature values from the internal temperature measurements using direct and inverse heat transfer methods, thus aiding in the thermal and structural design and analysis of high temperature vehicles.

Pizzo, Michelle↗

Innovative Miniaturized Heat Pumps for Buildings: Modular Thermal Hub for Building Heating, Cooling and Water Heating

BEETIT Project: Georgia Tech is using innovative components and system design to develop a new type of absorption heat pump. Georgia Tech’s new heat pumps are energy efficient, use refrigerants that do not emit greenhouse gases, and can run on energy from combustion, waste heat, or solar energy. Georgia Tech is leveraging enhancements to heat and mass transfer technology possible in microscale passages and removing hurdles to the use of heat-activated heat pumps that have existed for more than a century. Use of microscale passages allows for miniaturization of systems that can be packed as monolithic full-system packages or discrete, distributed components enabling integration into a variety of residential and commercial buildings. Compared to conventional heat pumps, Georgia Tech’s design innovations will create an absorption heat pump that is much smaller, has higher energy efficiency, and can also be mass produced at a lower cost and assembly time.

ARPA-E↗

Sarasota Climate: Monitoring Heat and Assessing Heat Vulnerability to Identify Locations for Heat Mitigation Efforts in Sarasota, Florida

The coastal county of Sarasota, Florida, is located within the humid subtropical climate region and experiences an average of 250 days of sunshine every year. The county has large, urbanized communities which are vulnerable to urban heat island (UHI) effects. These rapidly growing communities contribute to the increasing surface temperatures and placing more residents at risk of heat-related illness. In partnership with Sarasota County Sustainability, the Sarasota Climate team utilized Earth observation data from NASA Landsat 8 and Landsat 9’s Thermal Infrared Sensors (TIRS), and the International Space Station’s Ecosystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) to model UHI effects within the county during the Summer for the last five years, 2019 to 2023. Data analysis with the Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) and Urban Heat Exposure Assessment Tempe 1.0 (UHEAT 1.0) models and within ModelBuilder produced maps that identified the land surface temperature (LST) variance within the county, the regions that are most susceptible to extreme heat, and areas least capable of mitigating the effects of UHI. The results revealed that heat intensity varies significantly across Sarasota County with the highest temperatures in the more developed western part of the county. Additionally, the team identified that there are at least three vulnerable communities that exist in high-heat regions, including North Sarasota, Venice, and North Port. These regions have an overlap between socioeconomic sensitivity and environmental hazard that indicate a high priority in future heat mitigation efforts.

Remote sensing↗

Heating assemblies, heat exchange assemblies, methods for providing and/or exchanging heat, turbine combustion engines, and methods for powering turbine combustion engines

Heat exchanger assemblies and methods for providing heat exchange as well as methods providing specific energy to predetermined materials within an assembly as well as gas turbine engines as well as methods of powering same are provided. Heating assemblies are provided that can include: a heat-sinking substrate; and a selective emitter layer in thermal communication with the substrate. These assemblies can be provided as part of heat exchanger assemblies. Methods for providing heat to a fluid are also provided that can include heating a layer upon a substrate to provide photons of a predetermined wavelength to a fluid from the layer.Turbine combustion engines are also provided that can include a turbine having at least a portion of the blades in the hot section of the turbine coated with an emissivity layer in thermal communication with the turbine blade. Methods for powering turbine combustion engines are also provided.

McGrail, B. Peter↗

Variability of absorption heat pump efficiency for domestic water heating and space heating based on time-weighted bin analysis

Natural gas-driven absorption heat pumps are under renewed scrutiny as a viable technology for space conditioning and water heating for residential and commercial applications because of natural gas production trends, pricing, and the speculation that it might be a “bridge fuel” in the global transition towards energy sustainability. Since any level of natural gas combustion contributes to atmospheric carbon dioxide accumulation, the merits of natural gas consuming absorption technology are re-examined in this paper from the point of view of expected efficiency throughout the United States using a time-weighted bin temperature analysis. Such analyses are necessary because equipment standards for rated performance is restricted to one set ambient condition, whereas in actual practice, the absorption heat pump (AHP) must perform over a considerably wider range of external conditions, where its efficiency may be vastly different from that at the rated condition. Quantification of variation in efficiency and system performance are imperative to address how to provide the desired utility with the least environmental impact. In this paper, we examine limiting features in absorption heat pumps and relate it to systemic performances in sixteen cities across all eight climate zones in the U.S, each containing fifteen bin temperatures. The results indicate that the true expectation of performance of an AHP is significantly less than what might be optimized for the rated condition. Statistical measures of the variation in water heating COPs show that for most cities, the COP at the rated conditions is outside the 95% Confidence Interval. Moreover, it is concluded that deployment of absorption heat pump water heaters (AHPWH) may be restricted geographically by outdoor temperature constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of the Convective Heat-Exchange Coefficient in Inner Channels of Light-Absorbing Heat-Exchange Panels of Flat-Plate Solar Water-Heating Collectors Based on the Results of Their Short-Term Thermal Testing in Full-Scale Conditions

The results of investigations to determine the convective heat-exchange coefficient in the inner heat-exchange channels (HECs) of the light-absorbing heat-exchange panels (LAHPs) of flat-plate solar water-heating collectors (FPSWHCs) are given based on the results of their short-term heat testing in fullscale quasi-stationary conditions. The research method is based on determining the value of the required parameter from the heat-balance equation formed for the inner surfaces of the LAHP HEC walls. The structures of the flow LAHPs with a sheet-piped and thin parallelepiped form are selected as the test objects. The thermal tests of the FPSWHC are carried out during the near-midday hours of the light day to ensure the quasi-stationary mode condition. The reliability of the proposed method and results of the investigations is proved by comparing the values of the thermal-efficiency coefficients of the FPSWHC LAHPs obtained using two independent approaches.

14 SOLAR ENERGY↗

Exploring Mbar shock conditions and isochorically heated aluminum at the MEC end station of the LCLS

Recent experiments performed at the Matter in Extreme Conditions end station (MEC) of the Linac Coherent Light Source (LCLS) have demonstrated the first spectrally resolved measurements of plasmons from isochorically heated aluminum. The experiments have been performed using a seeded 8-keV x-ray laser beam as a pump and probe to both volumetrically heat and scatter x-rays from aluminum. Collective x-ray Thomson scattering spectra show a well-resolved plasmon feature that is down-shifted in energy by 19 eV. In addition, Mbar shock pressures from laser-compressed aluminum foils using Velocity Interferometer System for Any Reflector (VISAR) have been measured. The combination of experiments fully demonstrates the possibility to perform warm dense matter studies at the LCLS with unprecedented accuracy and precision.

INST, MATSCI, PHYS, XFEL↗