Interactions of satellite-speed helium atoms with satellite surfaces. 3: Drag coefficients from spatial and energy distributions of reflected helium atoms

Spatial and energy distributions of helium atoms scattered from an anodized 1235-0 aluminum surface as well as the tangential and normal momentum accommodation coefficients calculated from these distributions are reported. A procedure for calculating drag coefficients from measured values of spatial and energy distributions is given. The drag coefficient calculated for a 6061 T-6 aluminum sphere is included.

Sharma, P. K.↗

Turbulence measurements in axisymmetric jets of air and helium. I - Air jet. II - Helium jet

Results are presented of measurements on turbulent round jets of air and of helium of the same nozzle momentum efflux, using, for the air jets, x-wire hot-wire probes mounted on a moving shuttle and, for He jets, a composite probe consisting of an interference probe of the Way-Libby type and an x-probe. Current models for scalar triple moments were evaluated. It was found that the performance of the model termed the Full model, which includes all terms except advection, was very good for both the air and the He jets.

Panchapakesan, N. R.↗

Observations of the Helium II 304-A and Helium I 584-A atmospheric dayglow radiation.

Two photometers with bandpasses of 170 to 500 and 170 to 800 A were employed to observe dayglow emissions in the extreme ultraviolet (EUV) over an altitude range of 90 to 186 km. The emissions observed with these photometers are identified as resonantly scattered He I 584-A and He II 304-A radiations. At 186 km, 209 plus or minus 70 rayleighs of 584-A and 9.3 plus or minus 3.1 rayleighs of 304-A radiation were measured. These observations are compared with theoretical calculations of resonance scattering of solar emissions from geocoronal He and He(+). Using the Jacchia (1971) atmospheric model for He, it is found that the observed brightness of the 584-A emission requires that the solar 584-A line width be 0.014 plus or minus 0.004 A. In this model the maximum overhead brightness of 584-A dayglow would occur at 900 km, and its magnitude would be 1.9 plus or minus 0.6 kR. The authors' observation of 304-A brightness requires that the overhead column density of the He(+) ions be 4.2 x 10 to the 11th ions/sq cm column. This value is consistent with a constant-density plasmasphere model with a He(+) ion density of 320 ions/cu cm in the plasmasphere.

Kumar, S.↗

Prospects for determining the cosmological helium-3 to helium-4 ratio via absorption-line studies of the local interstellar medium

The prospects for determining the interstellar (He-3)/(He-4) ratio via absorption-line studies in the extreme ultraviolet are considered. A high-resolution extreme-ultraviolet spectrometer fed by a 1-meter-class telescope similar to that discussed in the Far Ultraviolet Spectroscopic Explorer Report (1983) is assumed, and it is found that detection of He-3 may be possible with less than three days of observing time. To measure the (He-3)/(He-4) ratio with sufficient precision to determine the number of light neutrino species will require over 50 days of integration time for each object studied.

Hurwitz, M.↗

Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.

Thermodynamic vent system↗

The Hottest Horizontal-Branch Stars in Omega Centauri: Late Hot Flasher vs. Helium Enrichment

UV observations of some massive globular clusters uncovered a significant population of very hot stars below the hot end of the horizontal branch (HB), the so-called blue hook stars. This feature might be explained either by the late hot flasher scenario here stars experience the helium flash while on the white dwarf cooling curve or by the helium-rich sub-population recently postulated to exist in some clusters. Spectroscopic analyses of blue hook stars in omega Cen and NGC 2808 support the late hot flasher scenario, but the stars contain much less helium than expected and the predicted C, N enrichment could not be verified from existing data. We want to determine effective temperatures, surface gravities and abundances of He, C, N in blue hook and canonical extreme horizontal branch (EHB) star candidates. Moderately high resolution spectra of stars at the hot end of the blue horizontal branch in the globular cluster omega Cen were analysed for atmospheric parameters (T(sub eff), log g) and abundances using LTE and Non-LTE model atmospheres. In the temperature range 30,000 K to 50,000 K we find that 37% of our stars are helium-poor (log nHe/nH less than -2), 49% have solar helium abundance within a factor of 3 (-1.5 less than or equal to log nHe/nH less than or equal to -0.5) and 14% are helium rich (log nHe/nH greater than -0.4). We also find carbon enrichment in step with helium enrichment, with a maximum carbon enrichment of 3% by mass. At least 30% of the hottest HB stars in omega Centauri show helium abundances well above the predictions from the helium enrichment scenario (Y = 0.42 corresponding to log nHe/nH approximately equal to -0.74). In addition the most helium-rich stars show strong carbon enrichment as predicted by the late hot flasher scenario. We conclude that the helium-rich HB stars in omega Cen cannot be explained solely by the helium-enrichment scenario invoked to explain the blue main sequence.

Moehler, S.↗

Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

Source record↗

Observations of solar-wind helium

It is pointed out that the concentration of helium in the solar wind relative to hydrogen fluctuates wildly. Under certain circumstances, the helium to hydrogen abundance ratio is strongly enhanced over probable solar values; at other times, the amount of helium in the solar wind is immeasurably small. In spite of the fact that helium is heavier than hydrogen, solar-wind helium often leaves the solar gravitational field with a higher velocity than does the hydrogen. It is thought that the mechanisms responsible for helium behavior may contain clues to unanswered questions concerning the acceleration and energy exchange processes of the entire solar wind. A brief review is given of the principal features and theories of the solar wind as a whole. In addition, measurement techniques are discussed. Emphasis throughout is on the experimental data concerning the dynamics of solar-wind helium. On the basis of coronal temperatures, it is shown that helium in the solar wind is almost always doubly ionized. It is also shown that the average abundance of helium ions in the solar wind is usually in the range of 3 to 6% by number.

Neugebauer, M.↗

Affect of Air Leakage into a Thermal-Vacuum Chamber on Helium Refrigeration Heat Load

NASA s Johnson Space Center (JSC) Building 32 houses two large thermal-vacuum chambers (Chamber A and Chamber B). Within these chambers are liquid nitrogen shrouds to provide a thermal environment and helium panels which operate at 20K to provide cryopumping. Some amount of air leakage into the chambers during tests is inevitable. This causes "air fouling" of the helium panel surfaces due to the components of the air that adhere to the panels. The air fouling causes the emittance of the helium panels to increase during tests. The increase in helium panel emittance increases the heat load on the helium refrigerator that supplies the 20K helium for those panels. Planning for thermal-vacuum tests should account for this increase to make sure that the helium refrigerator capacity will not be exceeded over the duration of a test. During a recent test conducted in Chamber B a known-size air leak was introduced to the chamber. Emittance change of the helium panels and the affect on the helium refrigerator was characterized. A description of the test and the results will be presented.

Garcia, Sam↗