Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEPA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Initial Testing of a Small Gamma Detector (GR1+) for Detection of Holdup in HEPA Filters

Measuring and assessing holdup is a key component of proper inventorying of a Material Balance Area (MBA). The Nuclear Material Control and Accountability (NMC&A) group at the Savannah River Site is responsible for ensuring that the methods used to determine holdup in the MBAs are valid for the conditions of that MBA. Holdup can be contained inside processing equipment or inside ventilation systems that that pulls air out of the glovebox through HEPA filters and stainless steel piping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric Analysis of Holdup in HEPA Filters

This technical document (TECH) contains an analysis of several conditions deemed credible for plutonium oxide buildup in high-efficiency air particulate (HEPA) filters to determine the effect of holdup inside the filter on reactivity. This document is performed in accordance with NCS-AP-005, R3 [Ref. (1)].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar dust simulant and at high rates of particle loading. The pressure drop across the filter media was measured as a function of accumulated particle mass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media.

Sub-ambient↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar he filter media was measured as a function of accumulated particle mdust simulant and at high rates of particle loading. The pressure drop across tass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media

Sub-ambient↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

Climate of the Field: Snowmass 2021

How are formal policies put in place to create an inclusive, equitable, safe environment? How do these differ between different communities of practice (institutions, labs, collaborations, working groups)? What policies towards a more equitable community are working? For those that aren't working, what external support is needed in order to make them more effective? We present a discussion of the current climate of the field in high energy particle physics and astrophysics (HEPA), as well as current efforts toward making the community a more diverse, inclusive, and equitable environment. We also present issues facing both institutions and HEPA collaborations, with a set of interviews with a selection of HEPA collaboration DEI leaders. We encourage the HEPA community and the institutions & agencies that support it to think critically about the prioritization of people in HEPA over the coming decade, and what resources and policies need to be in place in order to protect and elevate minoritized populations within the HEPA community.

Hansen, Erin V.↗

Scroll Filter System Development for Crewed Deep Space Missions

On board the International Space Station, particulate HEPA filters known as Bacterial Filter Elements (BFE's) are used as the main ventilation filters on the US modules. They consist of two stages of filtration, a static screen filter and a HEPA filter element. Historically, these filters have performed well during the life of the ISS. However, as NASA sets its sights towards mission beyond low earth orbit, or deep space, more capable filters requiring minimal maintenance will be essential because of the nature of these remote and of long duration missions. Therefore NASA is currently developing new filter systems for these mission. One of the filter designs being considered is a new filter system, coined the Scroll BFE. This filter provides two stages of filtration. The first stage is a pre-filter stage using a roll of screen media on a motorized spooling, or scrolling, mechanism to automate the change-out of the screen media in the flow. The second and finishing stage is a static HEPA filter element similar to the ones used on the ISS BFE's. The volume and dimensional format of the filter matches that of the ISS BFE which facilitates is deployment as potential future flight technology demonstration on board the ISS. Ground tests are underway to assess the filter system's performance under industrial standard test protocols applied in a custom designed filtration test stand. In addition, a method of generating relevant particulate matter loads, such as loose fibrous matter, is also being devised to challenge the filter in testing. The latter test challenge will help determine the pre-filter's capacity for handling layers of lint, or fibrous, particulate matter. Early results confirm HEPA efficiency performance of the HEPA stage. This paper will present the results of ground testing of the Scroll Filter System prototype.

Agui, Juan H.↗

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗