Search NASA⌕ Search

SEARCH · Search NASA

Results for “HUB LOADS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OpenFAST Modeling of the T-Omega Wind Floating Offshore Wind Turbine System

To reduce the cost of offshore wind energy through a more efficient design of the floating support structure, T-Omega Wind developed a novel lightweight and shallow-draft platform concept that aims to achieve a wave-following behavior without resonance amplification. The rotor and generator are carried by four tower legs with each leg supported by a shallow-draft float at the base. In preparation for a more detailed analysis, a coupled aero-hydro-elastic model of the proposed concept is developed in OpenFAST. The detailed modeling approach is presented, including a novel application of the SubDyn substructure dynamics module of OpenFAST to approximate the loads on the axle tube at the tower top from the rotor hub bearings. Preliminary results obtained with the OpenFAST model by rigidifying the substructure and blades indicate that the original sizing of the design can lead to large hub acceleration in the axial/surge and pitch directions due to platform-pitch motion. The high axial acceleration also potentially leads to large bending moments in the four tower legs. To address these issues, an updated design is developed with, among other changes, increased float spacing at the tower base and improved shear-transmitting geometry of the tower legs. The new design suggests significantly reduced extreme hub accelerations under the same conditions even with structural flexibility and will be further analyzed in the future through full aero-hydro-servo-elastic simulations.

FOWT↗

OpenFAST Modeling of the T-Omega Wind Floating Offshore Wind Turbine System

To reduce the cost of offshore wind energy through a more efficient design of the floating support structure, T-Omega Wind developed a novel lightweight and shallow-draft platform concept that aims to achieve a wave-following behavior without resonance amplification. The rotor and generator are carried by four tower legs with each leg supported by a shallow-draft float at the base. In preparation for a more detailed analysis, a coupled aero-hydro-elastic model of the proposed concept is developed in OpenFAST. The detailed modeling approach is presented, including a novel application of the SubDyn substructure dynamics module of OpenFAST to approximate the loads on the axle tube at the tower top from the rotor hub bearings. Preliminary results obtained with the OpenFAST model by rigidifying the substructure and blades indicate that the original sizing of the design can lead to large hub acceleration in the axial/surge and pitch directions due to platform-pitch motion. The high axial acceleration also potentially leads to large bending moments in the four tower legs. To address these issues, an updated design is developed with, among other changes, increased float spacing at the tower base and improved shear-transmitting geometry of the tower legs. The new design suggests significantly reduced extreme hub accelerations under the same conditions even with structural flexibility and will be further analyzed in the future through full aero-hydro-servo-elastic simulations.

ENGINEERING,WIND ENERGY↗

OpenFAST Modeling of the T-Omega Wind Floating Offshore Wind Turbine System: Preprint

To reduce the cost of offshore wind energy through a more efficient design of the floating support structure, T-Omega Wind developed a novel lightweight and shallow-draft platform concept that aims to achieve a wave-following behavior without resonance amplification. The rotor and generator are carried by four tower legs with each leg supported by a shallow-draft float at the base. In preparation for a more detailed analysis, a coupled aero-hydro-elastic model of the proposed concept is developed in OpenFAST. The detailed modeling approach is presented, including a novel application of the SubDyn substructure dynamics module of OpenFAST to approximate the loads on the axle tube at the tower top from the rotor hub bearings. Preliminary results obtained with the OpenFAST model by rigidifying the substructure and blades indicate that the original sizing of the design can lead to large hub acceleration in the axial/surge direction and in the pitch direction due to platform-pitch motion. The high hub acceleration also potentially leads to large bending moments in the four tower legs. To address the issue identified, an updated design is developed with, among other changes, increased float spacing at the tower base and improved geometry of the tower legs. The new design suggests significantly reduced extreme platform pitch angles under the same conditions and will be further analyzed in the future through full aero-hydro-servo-elastic simulations.

FOWT↗

Hybrid Energy Management with Real-Time Control of a High-Power EV Charging Site

Decarbonization of transportation systems is driving higher capacity energy storage and faster charging power requirements in electric vehicles (EVs). Given the potential advantages - such as increased efficiency, reduced inverter capacity, and less total cable mass - there is a demand in the industry for more DC distribution for high-power charging (HPC) hubs. However, the cost-effective, adaptive, and robust operation of the DC-coupled HPC hub necessitates a robust site energy management system (SEMS). Validating SEMS operation using a digital twin of an HPC hub in a real-time simulator (RTS) platform is crucial before field deployment. In this study, we propose a hybrid energy management site controller designed to achieve high-level, long-term operational objectives while managing low-level power sharing control between hub assets. We develop a centralized model predictive controller (MPC) to optimize hub operating points and use these points to update the droop parameters of the site energy storage system (ESS). This approach ensures the hub follows an optimal operating point while maintaining the flexibility to respond to load surges. We tested and verified our proposed approach both offline and on a Controller Hardware-in-the-loop (C-HIL) simulation platform integrated with a SEMS framework, demonstrating real-time site operation and validating a cost-effective and robust site controller.

ADVANCED PROPULSION SYSTEMS↗

KG-Hub—building and exchanging biological knowledge graphs

Knowledge graphs (KGs) are a powerful approach for integrating heterogeneous data and making inferences in biology and many other domains, but a coherent solution for constructing, exchanging, and facilitating the downstream use of KGs is lacking. Here we present KG-Hub, a platform that enables standardized construction, exchange, and reuse of KGs. Features include a simple, modular extract–transform–load pattern for producing graphs compliant with Biolink Model (a high-level data model for standardizing biological data), easy integration of any OBO (Open Biological and Biomedical Ontologies) ontology, cached downloads of upstream data sources, versioned and automatically updated builds with stable URLs, web-browsable storage of KG artifacts on cloud infrastructure, and easy reuse of transformed subgraphs across projects. Current KG-Hub projects span use cases including COVID-19 research, drug repurposing, microbial–environmental interactions, and rare disease research. KG-Hub is equipped with tooling to easily analyze and manipulate KGs. KG-Hub is also tightly integrated with graph machine learning (ML) tools which allow automated graph ML, including node embeddings and training of models for link prediction and node classification.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-objective Decisions on Integrated Energy Systems Planning and Operation for Industrial Combined Heat and Power Supply

Unlike the power sector—which can transmit electricity over long distances via established grids—the industrial sector poses a unique challenge due to its geographically concentrated large-scale heat processes. Enhancing energy security in such industrial parks provides a dual benefit: reduced exposure to volatile fossil fuel prices and improved economic viability, largely driven by economies of scale in energy supply and distribution. This study presents a comprehensive technoeconomic analysis of a nuclear energy hub, employing a mechanism-focused approach to evaluate uncertainties in operational strategies and capacity optimization. Load profiles from three major energy intesive industries—chemical, refinery, and steelmaking—are examined, each presenting unique challenges and opportunities for nuclear energy integration. We adopt a multi-objective optimization framework, converting multiple objectives into a single objective function through the e-constraint method. The findings highlight clear trade-offs between system conditions and varying levels of energy independence. Overall, this analysis is granular enough to address industry-specific concerns yet sufficiently generalizable to provide actionable insights into the feasibility of nuclear-based clean heat solutions for the industrial sector.

25 - ENERGY STORAGE↗

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

A Methodology for Robust Load Reduction in Wind Turbine Blades Using Flow Control Devices

Decades of wind turbine research, development and installation have demonstrated reductions in levelized cost of energy (LCOE) resulting from turbines with larger rotor diameters and increased hub heights. Further reductions in LCOE by up-scaling turbine size can be challenged by practical limitations such as the square-cube law: where the power scales with the square of the blade length and the added mass scales with the volume (the cube). Active blade load control can disrupt this trend, allowing longer blades with less mass. This paper presents the details of the development of a robust load control system to reduce blade fatigue loads. The control system, which we coined sectional lift control or SLC, uses a lift actuator model to emulate an active flow control device. The main contributions of this paper are: (1) Methodology for SLC design to reduce dynamic blade root moments in a neighborhood of the rotor angular frequency (1P). (2) Analysis and numerical evidence supporting the use of a single robust SLC for all wind speeds, without the need for scheduling on wind speed or readily available measurements such as collective pitch or generator angular speed. (3) Intuition and numerical evidence to demonstrate that the SLC and the turbine controller do not interact. (4) Evaluation of the SLC using a full suite of fatigue and turbine performance metrics.

17 WIND ENERGY↗

SiM4DC [SWR-25-09]

SiM4DC is a suite of MATLAB/Simulink models specifically developed for simulating offline and real-time high-power charging hubs with various components such as grid-tie inverters, EVSEs, EVs, energy storage systems, renewable generation, and uncontrolled site loads.

Ucer, Emin [National Renewable Energy Laboratory (↗

Toward control co-design of utility-scale wind turbines: Collective vs. individual blade pitch control

A large-eddy simulation framework has been coupled with controller modules to systematically investigate the impacts of collective (CPC) and individual (IPC) pitch control strategies on utility-scale wind turbine energy production and fatigue loads. Wind turbine components were parameterized using an actuator surface model to simulate the rotor blades and the turbine nacelle. The baseline CPC and IPC algorithms, consisting of single-input single-output proportional–integral controllers and two integral controllers, respectively, were incorporated into the numerical framework. A series of simulations were carried out to investigate the relative performance of the two controllers under various turbulent inflow conditions, spanning hub-height velocities of 7 to 14 m/s. The numerical simulation results of this study showed that, in comparison to the CPC, the IPC controller could successfully reduce the damage equivalent loads of utility-scale turbines at regions 2 and 3 of turbine operation by about 3% and 40%, respectively, without any penalty on the power production of the turbine. It was also shown that, despite its minor impact on the turbulence kinetic energy of the wake, the IPC controller did not influence the recovery of the turbine wake.

17 WIND ENERGY↗

Effects of wind field characteristics on pitch bearing reliability: a case study of 5 MW reference wind turbine at onshore and offshore sites; Auswirkungen von Windfeldeigenschaften auf die Zuverlässigkeit von Rotorblattlagern: eine Fallstudie über eine 5-MW-Referenz-Windkraftanlage an Onshore- und Offshore-Standorten

This paper presents a study on pitch bearing basic rating life affected by wind field characteristics at both onshore and offshore wind sites. The National Renewable Energy Laboratory 5 MW reference wind turbine is selected for the study. Wind field characteristics including reference hub height mean wind speed, wind speed distribution, wind shear, and vertical inflow are studied. A decoupled approach is employed where global analysis is performed first. Second, the load effects from the global analysis are applied on a reference pitch bearing designed based on best industrial practices. For the case study onshore site, it is found that the Kernel density estimation best fits the wind distribution, while the International Electrotechnical Commission proposed distribution appears to be not suitable. Moreover, it is shown that the seed number has high effect on the bearing life in turbulence wind and the wind speeds around rated have the highest contribution in both bearing fatigue damage and extreme load failure. The results contribute to better understanding of the wind field characteristics on the pitch bearing life.

17 WIND ENERGY↗

Development of a DC Distribution Testbed for High-Power EV Charging

This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Technology Integration to Gain Commercial Efficiency for the Urban Goods Delivery System, Meet Future Demand for City Passenger and Delivery Load/Unload Spaces, and Reduce Energy Consumption

This three-year project supported by the U.S. Department of Energy Vehicle Technologies Office has the potential to radically improve the urban freight system in ways that help both the public and private sectors. Working from 2018-2021, project researchers at the University of Washington’s Urban Freight Lab and collaborators at the Pacific Northwest National Laboratory have produced key data, tested technologies in complex urban settings, developed a prototype parking availability app, and helped close major knowledge gaps. All the fruits of this project can be harnessed to help cities better understand, support and actively manage truck load/unload operations and their urban freight transport infrastructure. Project learnings and tools can be used to help make goods delivery firms more efficient by reducing miles traveled and the time it takes to complete deliveries, benefitting businesses and residents who rely on the urban freight system for supplies of goods. And, ultimately, these project learnings and tools can be used to make cities more livable by minimizing wasted travel, which, in turn, contributes to reductions in fuel consumption and emissions. Cities today are challenged to effectively and efficiently manage their infrastructure to absorb the impacts of ever-increasing e-commerce-fueled delivery demand. All delivery trucks need to park somewhere to unload and load. Yet today’s delivery drivers have no visibility on available parking until they arrive at a site, which may be full. That means they can wind up cruising for parking, which wastes time and fuel and contributes to congestion. Once drivers do find parking, the faster they can unload at the spot, the faster they free up space for other drivers, helping others avoid circling for parking. This makes the parking space—and thus the greater load/unload network—more productive. To this end, the research team successfully met the project’s three goals, developing and piloting strategies and technologies to: 1. Reduce parking-seeking behavior in the study area by 20%; 2. Reduce parcel truck dwell time (the time a truck spends in a spot to load/unload) in the study area by 30%; 3. Increase curb space, alley space and private loading bay occupancy rates in the study area. The research team met these goals by creating and piloting on Seattle streets OpenPark, a first-of-its-kind real-time and forecasting curb parking app customized for commercial delivery drivers—giving drivers the “missing link” in their commonly used routing tools that tell them how best to get to delivery locations, but not what parking is available to use when they get there. Installing in-ground sensors on commercial vehicle load zones (CVLZs) and passenger load zones (PLZs) in the 10-block study area in Seattle’s downtown neighbourhood of Belltown let researchers glean real-time curb parking data. The research team also met project goals by piloting three parcel lockers in public and private spaces open to any delivery carrier, creating a consolidated delivery hub that lets drivers complete deliveries faster and spend less time parked. Researchers collected and analysed data to produce the first empirical, robust, statistically significant results as to the impact of the lockers, and app, on on-the-ground operations. In addition to collecting and analyzing sensor and other real-time and historical data, researchers rode along with delivery drivers to confirm real-world routing and parking behavior. Researchers also surveyed building managers on their private loading bay operations to understand how to boost usage.

97 MATHEMATICS AND COMPUTING↗

Spatially Resolved Domicile Charging Demands for Light-, Medium-, and Heavy-Duty Electric Vehicles in Virginia

The use of plug-in electric vehicles (PEVs) and resulting grid impacts are likely to grow rapidly, and evaluation of optimal smart charge management and grid integration strategies is warranted now. Evaluating distribution grid impacts requires fine-grained models of PEV operations to estimate charging loads across diverse vehicles at high spatial resolution. We propose such a model and consider a high-electrification scenario in Richmond and Newport News, Virginia. Our framework considers four categories of vehicle that are amenable to early aggressive electrification: light-duty passenger vehicles (LDV), trucks and vans with a focus on delivery or other local operations, school buses, and transit buses. These vehicles have a relatively consistent domicile, reducing the need for public charging infrastructure rollout to electrify. We apply a recent LDV model and propose new models for each vocation of medium- and heavy-duty vehicle, leveraging telematics data. We demonstrate our framework in Virginia and find energy demands in the region may total 15 GWh day, with most consumed by LDV. However, considering power demand at high spatial resolution reveals a different trend: LDVs have relatively small peak loads at specific sites (peak site demand around 800 kW) compared to average and high demand medium- and heavy-duty vehicle charging sites (peak site demand around 6,000 kW at a transit bus depot, 1,500 kW at a local freight hub, and 1,000 kW at a school). Our framework yields insights on the relative impacts of each vocation and enables future work to tailor grid integration strategies to each vehicle category.

33 ADVANCED PROPULSION SYSTEMS↗

Self-Lubricating Bushing Testing for John Day Dam Ka plan Turbine Replacement

The goal of this testing program is to find suitable self-lubricated alternatives to replace the in use oil lubricated grooved-bronze bushing in Kaplan runner hubs that are currently being utilized at John Day Dam operated by the U.S. Army Corps of Engineers (USACE). Scaled bushing testing utilizing a Pacific Northwest National Laboratory designed, fabricated, and operated Bushing Test Stand under the direction and funding from USACE determined that self-lubricated bushings tested appear capable of outperforming the current oil-lubricated bronze bushings. Performance tests are focused on durability which includes cyclic load bearing properties and articulations under various loading scenarios. This testing was performed at nominally 1/5 th scale. A scaling sensitivity analysis determined that scaled testing results apply to prototypic size. This report shows the direct comparison between the current baseline bronze bushing to self-lubricated bushings from various manufacturers. Bushing data like coefficient of friction and bushing material loss (associated with bushing wear) was determined. Self-lubricated bushings tested include products manufactured specifically for hydropower applications by the following companies: Trelleborg, Kamatics, Anonymous, and Tenneco/Deva.

42 ENGINEERING↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 8 - Raw Data

Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM during Sequence 8, but it was parked during Sequence 9. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. Sonic anemometers were mounted on a strut downwind of the turbine. The strut was mounted to the T-frame, which was rotated to align the anemometers aft of the 9% and 49% radius locations at hub height. Because of this configuration, the tunnel balance data are considered invalid. Sequence 9 was designed to compare the downwind sonic anemometer readings with the upwind sonic anemometers without interference from the turbine. The rotor was parked with the instrumented blade at 0° azimuth. All pressure measurements obtained in Sequence 9 are invalid because sufficient time for temperature stabilization did not occur, thus all associated data values were flagged as not applicable by setting the measured values in the data file to 0.0000 Pa. This test is further described in Appendix G.

17 WIND ENERGY↗