Search NASA⌕ Search

SEARCH · Search NASA

Results for “HVAC sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Effectiveness of Advanced Three Fluid Heat and Mass Exchanger

Advanced internally-cooled membraned-based heat and mass exchangers (HMX), which accounts for three separate fluid streams, are capable of utilizing the sensible and latent heat removed from spacecooling to heat water. The technology provides a unique approach of enhancing the efficiency and cost effectiveness of future HVAC equipment. This paper aims to numerically identify and understand the impact of geometric size, operation conditions, and membrane properties on the overall effectiveness of three-fluid HMXs. The simulations are based on an ORNL in-house open-source HMX model which is capable of simulating such three-fluid HMX components for various flow patterns. The results are expected to enable detailed configuration evaluation and provide in-depth understanding of optimal three-fluid HMX performance at cost effectiveness.

Gao, Zhiming↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel transient infrared imaging method for non-intrusive, low-cost, fast, and accurate air leakage detection in building envelopes

Air leakage through the building envelope in the U.S. accounts for about four quads of energy annually, costing approximately $40 billion per year. However, a high-fidelity and non-intrusive method to detect air leakage has not been demonstrated to date. Here, in this paper, we propose a novel non-intrusive and low-cost method called Transient Infrared (IR) Imaging (TIRI) that can rapidly and accurately identify air leakage locations and relative rates on building envelopes. When the interior and exterior temperatures are different, and a small internal pressure pulse is created by HVAC, the temperature at locations with air leakages will change rapidly, while the areas without a leakage do not change. Based on a heat transfer model, we have derived the temperature change as a function of time after the HVAC is turned on. By tracking the temperature change, which depends on leakage rate and size, we have obtained the air leakage map in the case studies. Using an exterior door as an example, we took transient IR images in different seasons and different times of the day, and successfully obtained the leakage map in all the scenarios. Successfully obtained the air leakage map even when the indoor-outdoor air temperature difference is as small as 2 °C. We have also realized a detection speed of 10s and demonstrated that this method also worked for windows, which have mirror-like IR reflections. Our TIRI method will accelerate the improvement of airtightness in buildings, save building energy, and help reduce greenhouse gas emissions.

42 ENGINEERING↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.

42 ENGINEERING↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

42 ENGINEERING↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Manufactured Home Equipment Sizing and Selection Tool

This tool is for use for manufactured homes built to the HUD Code (thermal provisions of the Manufactured Housing Construction and Safety Standards, Subpart F, Section §3280), including manufactured homes certified as ENERGY STAR® and DOE Efficient New Homes. It provides a simple look-up procedure to assist equipment specifiers, HVAC contractors, home installers, retailers, manufacturers, and electric utility staff. For new manufactured homes, it guides in selection of single speed heat pumps and air conditioners. For existing homes, it determines design conditions and nominal equipment size. The guidelines provide a simple but accurate procedure that reduces oversizing and its associated problems.

Source record↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Air Sealing Demonstration: Denver Federal Center Building 40

This project aimed to demonstrate building airtightness achieved by automated air sealing in a commercial building setting. The automated air sealing demonstrated in this project uses a modified blower door to pressurize and distribute the sealing aerosol to achieve the required building airtightness. To demonstrate this technology, Building 40 at the Denver Federal Center, a federally owned campus under the jurisdiction, custody and control of the U.S. General Services Administration (GSA), was selected for testing (Figure 2). This building is currently undergoing several retrofit projects, including increasing insulation, installing high-performance windows, and adding advanced equipment, control systems, and automated air sealing. This demonstration project involved installing automated air sealing and measuring the improvements in the building's airtightness. The automated air sealing was installed over two days by AeroBarrier, the vendor. An external blower door test contractor measured the airtightness of the demonstration space before and after air sealing. The new airtightness value and the percentage increase in airtightness were used to evaluate the energy savings potential of automated air sealing. These airtightness values were used to compute the energy savings and CO 2 emissions reduction for different climate zones, building types, and initial airtightness conditions. In addition, the heating, ventilation and air conditioning (HVAC) load reduction attributable to the reduced building air leakage was studied. This study included research to determine the cost and time reduction of automated air sealing. Finally, the automated air sealing performance was evaluated qualitatively using a focus group discussion that included GSA and Bristol, the general contractor. The installation has shown the demonstration site, with a floor size of 4,462 ft 2 , air leakage has reduced by more than 50% in less than 7 hours, including preparation, site sealing, and cleanup. The performance objectives were classified as quantitative or qualitative based on the evaluation metrics used to assess the project’s success. The key performance objectives for this project were the level of airtightness achieved, the time and cost required to perform the sealing, and the HVAC load reduction attributable to air sealing. Table 1 shows the quantitative performance objectives.

42 ENGINEERING↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

A review of computing-based automated fault detection and diagnosis of heating, ventilation and air conditioning systems

We report faults in Heating, Ventilation, and Air Conditioning (HVAC) systems of buildings result in significant energy waste in building operation. With fast-growing sensing data availability and advancement in computing, computational modeling has demonstrated strong capability to detect and diagnose HVAC system faults, hence, ensuring efficient building operation. This paper comprehensively reviews the state-of-the-art computing-based fault detection and diagnosis (FDD) for HVAC systems. Overall, the reviewed computing-based FDD methods are classified as two major approaches: knowledge-based and data-driven approaches. We then identify multiple important topics, including data availability, training data size, data quality, approach generality, capability, interpretability, and required modeling efforts, along with corresponding metrics to summarize the most updated FDD development. Generally, the knowledge-based approaches are further divided as physics-based modeling, Diagnostic Bayesian Network, and performance indicator-based methods while data-driven approaches include supervised learning, unsupervised learning, and regression and statistics-based methods. State-of-the-art FDD development, remaining challenges, and future research directions are further discussed to push forward FDD in practice. Availability of fault data, capability of existing methods to deal with complex fault situations (such as simultaneous faults), modeling interpretability for data-driven methods, and required engineering efforts for physics-based methods are identified as remaining challenges in FDD development. Improving modeling fidelity and reducing modeling efforts are essential for applying physics-based methods in real buildings. Meanwhile, addressing fault data availability, increasing algorithm adaptability, and handling multiple faults are essential to further enhance the applicability of data-driven FDD approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Household energy resilience in extreme weather events: An investigation of energy service importance, HVAC usage behaviors, and willingness to pay

Household energy resilience, particularly maintaining essential energy services within an acceptable and affordable level, is critical during extreme weather events (e.g., winter storms, heat waves) with power shortages or outages. However, the research on the importance and acceptable compromise levels of energy services, HVAC usage behavior changes, and willingness to pay (WTP) for energy services during disasters is limited. Therefore, this study investigates the importance and compromise of household energy services, HVAC usage behaviors, and WTP, as three key dimensions of household energy resilience, in both normal days and disaster scenarios through surveys (n=485). First, 12 common residential end-uses are grouped into high, mid, and low-priority services using hierarchical clustering, in which high-priority services (perceived as important and un-compromisable) include food cooking and storage (refrigerator and freezer) and thermal comfort (space heating and cooling), mid-priority services involve water heating and lighting, while low-priority services are mostly related to entertainment and housework (e.g., TV, laundry). Also, HVAC use patterns demonstrate that occupants become more energy conservative during disasters, e.g., reducing durations of running HVAC and adjusting temperature setpoints to save energy. In terms of energy cost, approximately 60% of respondents are willing to pay more to maintain energy services during disasters, although only 13% are prepared to pay over double the normal energy prices. The regression models further reveal that household energy resilience varies across different sociodemographic groups (e.g., age, income, family size) and is impacted by disaster experience and beliefs in clean energy and climate. In conclusion, these research findings provide important perspectives to understand household energy resilience and inform measures for disaster adaptation of households in extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗