The Development of Models for Carbon Dioxide Reduction Technologies for Spacecraft Air Revitalization

Through the respiration process, humans consume oxygen (O2) while producing carbon dioxide (CO2) and water (H2O) as byproducts. For long term space exploration, CO2 concentration in the atmosphere must be managed to prevent hypercapnia. Moreover, CO2 can be used as a source of oxygen through chemical reduction serving to minimize the amount of oxygen required at launch. Reduction can be achieved through a number of techniques. The National Aeronautics and Space Administration (NASA) is currently exploring the Sabatier reaction, the Bosch reaction, and co-electrolysis of CO2 and H2O for this process. Proof-of-concept experiments and prototype units for all three processes have proven capable of returning useful commodities for space exploration. While all three techniques have demonstrated the capacity to reduce CO2 in the laboratory, there is interest in understanding how all three techniques would perform at a system-level within a spacecraft. Consequently, there is an impetus to develop predictive models for these processes that can be readily re-scaled and integrated into larger system models. Such analysis tools provide the ability to evaluate each technique on a comparable basis with respect to processing rates. This manuscript describes the current models for the carbon dioxide reduction processes under parallel developmental e orts. Comparison to experimental data is provided were available for veri cation purposes.

Swickrath, Michael J.↗

The Development of Models for Carbon Dioxide Reduction Technologies for Spacecraft Air Revitalization

Through the respiration process, humans consume oxygen (O2) while producing carbon dioxide (CO2) and water (H2O) as byproducts. For long term space exploration, CO2 concentration in the atmosphere must be managed to prevent hypercapnia. Moreover, CO2 can be used as a source of oxygen through chemical reduction serving to minimize the amount of oxygen required at launch. Reduction can be achieved through a number of techniques. NASA is currently exploring the Sabatier reaction, the Bosch reaction, and co- electrolysis of CO2 and H2O for this process. Proof-of-concept experiments and prototype units for all three processes have proven capable of returning useful commodities for space exploration. All three techniques have demonstrated the capacity to reduce CO2 in the laboratory, yet there is interest in understanding how all three techniques would perform at a system level within a spacecraft. Consequently, there is an impetus to develop predictive models for these processes that can be readily rescaled and integrated into larger system models. Such analysis tools provide the ability to evaluate each technique on a comparable basis with respect to processing rates. This manuscript describes the current models for the carbon dioxide reduction processes under parallel developmental efforts. Comparison to experimental data is provided were available for verification purposes.

Swickrath, Michael J.↗

Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

Chullen, Cinda↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.

Meginnis, Ian M.↗

Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

Chullen, Cinda↗

Sensor Integrated Pilot Mask for On-Board, Real-Time, Monitoring of Pilot Breathing Gas

A pilot's job is unique in the demands it places on the human body, and many conditions can seriously affect pilot performance, threatening mission completion and pilot safety. The gas in a flight mask contains key indicators of the pilot's physiological state, including oxygen inhaled and carbon dioxide exhaled, which can signal hypoxia, hyperoxia, hypocapnia, and hypercapnia. A fiber optic-based sensor system, integrated into the pilot mask, has been developed to monitor in real time, during flight, the pilot breathing gas levels. Monitoring the partial pressure of oxygen and carbon dioxide in the pilot mask supports real-time closed loop control of the on-board oxygen generation system, based on a direct reading of what the pilot is actually breathing. The pilot Mask Sensor (MASES) system incorporates luminescence sensors for pO2, pCO2, relative humidity, pressure, and temperature in a compact probe in the pilot mask; it is based on sensor technology developed for gas monitoring in space suit systems, in work supported by NASA under the Small Business Innovation Research program. Relevant requirements for the MASES system include sensor operation while wet, operation at reduced pressure, ability to withstand rapid decompression, operation in a pure oxygen atmosphere, low power consumption, a compact readout unit, and flexible miniature sensors; many of these requirements are shared with gas monitors in space suits. Data are presented from tests conducted with human subjects in an altitude chamber and in a centrifuge.

Delgado Alonso, Jesus↗

Evidence-based Approach to Establish Space Suit Carbon Dioxide Limits

A literature survey was conducted to assess if published data (evidence) could help inform a space suit carbon dioxide (CO2) limit. The search identified more than 120 documents about human interaction with elevated CO2. Until now, the guiding philosophy has been to drive space suit CO2 as low as reasonably achievable. NASA’s EVA Office requested an evidencebased approach to support a new generation of exploration-class extravehicular activity (EVA) space suits. Specific literature data about CO2 are not available for EVA in microgravity because EVA is an operational activity and not a research platform. However, enough data from groundbased research are available to facilitate a consensus of expert opinion on space suit CO2 limits. The compilation of data in this report can answer many but not all concerns about the consequences of hypercapnic exercise in a space suit. Inspired partial pressure of CO2 (PICO2) and not dry-gas partial pressure of CO2 (PCO2) is the appropriate metric for hypercapnic dose to establish space suit CO2 limits. The reduction of inspired gas partial pressures by saturation of the inspired gases with water vapor at 37°C is a significant factor under conditions of hypobaric space suit operation. Otherwise healthy EVA astronauts will exhibit wide variability in responses to acute hypercapnia while at rest and during exercise. What is clear from the literature is the absence of prospective (objective) accept or reject criteria for CO2 exposure in general, and no such criteria exist for operating a space suit. There is no absolute “Gold Standard” for an acceptable acute hypercapnic limit, just a gradual decrease in performance as CO2 increases. Acceptable CO2 exposure limits are occupation, situation (learned or novel tasks), and personspecific. Investigators who measured hypercapnic physiology rarely correlated those changes to neurocognitive symptoms, and those that measured hypercapnic neurocognition rarely correlated those changes with physiology. Some answers about changes in neurocognition and functional EVA performance during hypercapnic exercise in a space suit await new research.

Conkin, Johnny↗

EMU CO2 Washout Comparative Assessments for the HAB/HAP-E in support of EVA 80

After water was reported in the EMU helmet during ISS US EVA-80, mitigation strategies were created to attempt to arrest the motion of any droplets that enter the helmet for future Extravehicular Activities (EVAs). This included adding absorbent materials into the interior of the helmet. But before a mitigation strategy can be implemented, it must first be proven to be safe. Towards this aim, a computational fluid dynamics (CFD) model was developed to assess the effect that the absorbent material has on the concentration of carbon dioxide in the EMU helmet. Within a small, closed volume such as a helmet, some amount of the carbon dioxide produced by the suit-wearer will be re-inhaled before being cleared from the oral-nasal region. The ability of the suit to remove carbon dioxide is referred to as CO2 washout. Pathological levels of inhaled CO2 (hypercapnia) are associated with dizziness, fatigue, and headaches. The CFD model was built in ANSYS Fluent and adapted to assess CO2 washout in a variety of scenarios grouped into three categories: purge cases, varying metabolic rates, and varying sorbent material configurations. The presence of the sorbent material did not prove detrimental to CO2 washout in the helmet.

Moses Navarro↗

EMU CO2 Washout Comparative Assessments for the HAB/HAP-E in Support of EVA 80

After water was reported in the Extravehicular Mobility Unit (EMU) helmet during ISS US EVA 80, mitigation strategies were created to attempt to arrest the motion of any droplets that enter the helmet for future Extravehicular Activities (EVAs). This included adding absorbent materials into the interior of the helmet. But before a mitigation strategy can be implemented, it must first be proven to be safe. Towards this aim, a computational fluid dynamics (CFD) model was developed to assess the effect that the absorbent material has on the concentration of carbon dioxide in the EMU helmet. Within a small, closed volume such as a helmet, some amount of the carbon dioxide produced by the suit-wearer will be re-inhaled before being cleared from the oral-nasal region. The ability of the suit to remove carbon dioxide is referred to as CO2 washout. Pathological levels of inhaled CO2 (hypercapnia) are associated with dizziness, fatigue, and headaches. The CFD model was built in ANSYS Fluent and adapted to assess CO2 washout in a variety of scenarios grouped into three categories: ventilation cases, varying metabolic rates, and varying sorbent material configurations. The presence of the sorbent material did not prove detrimental to CO2 washout in the helmet.

Moses Navarro↗

EMU CO2 Washout Comparative Assessments for the HAB/HAP-E in Support of EVA 80

After water was reported in the Extravehicular Mobility Unit (EMU) helmet during ISS US EVA 80, mitigation strategies were created to attempt to arrest the motion of any droplets that enter the helmet for future Extravehicular Activities (EVAs). This included adding absorbent materials into the interior of the helmet. But before a mitigation strategy can be implemented, it must first be proven to be safe. Towards this aim, a computational fluid dynamics (CFD) model was developed to assess the effect that the absorbent material has on the concentration of carbon dioxide in the EMU helmet. Within a small, closed volume such as a helmet, some amount of the carbon dioxide produced by the suit-wearer will be re-inhaled before being cleared from the oral-nasal region. The ability of the suit to remove carbon dioxide is referred to as CO2 washout. Pathological levels of inhaled CO2 (hypercapnia) are associated with dizziness, fatigue, and headaches. The CFD model was built in ANSYS Fluent and adapted to assess CO2 washout in a variety of scenarios grouped into three categories: ventilation cases, varying metabolic rates, and varying sorbent material configurations. The presence of the sorbent material did not prove detrimental to CO2 washout in the helmet.

Moses Navarro↗