NIOBIUM-1% ZIRCONIUM, NATURAL-CIRCULATION, BOILING-POTASSIUM CORROSION LOOP TEST
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.
This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.
Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.
The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.
Explore the source record for details and available documents.
Chemical recycling of polyolefin copolymers (PCPs) is essential for mitigating plastic pollution, yet achieving selective depolymerization into C 2 –C 3 monomers at high productivity remains challenging. Here, we introduce a double-layered ultrafast heating reactor (DUHR) that integrates Joule heating with a high-entropy alloy (HEA) catalyst composed of near-equimolar Co, Cu, Fe, Mn, and Ni. We achieve highly selective depolymerization of PCP into ethylene and propylene, yielding a 70% non-condensable fraction. Significant aromatic fractions form via radical-driven pathways—a behavior distinct from conventional externally heated pyrolyzers—highlighting DUHR's ability to generate reactive species and modulate reaction pathways. Furthermore, these findings demonstrate an effective strategy for chemical recycling of real-world plastic waste for polyolefin circularity and sustainable resource recovery.
The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.
Strategy support to determine the best approach to deploy solar technologies and commercially viable heat pump projects across their existing Rural Energy Partners solar project development support channel.
Explore the source record for details and available documents.
This material will be presented at the Interagency Advanced Power Group (IAPG) Chemical Working Group and Safety Panel Meeting. IAPG serves as the premier organization coordinating the collaboration and information exchange of advanced power research and development within the U.S. government.
This report looks at the viability and best approach when producing synthetic fuels using heat and power supplied by advanced nuclear energy systems. The report looks at a low temperature integration pathway with four types of advanced reactors: a pressurized water reactor (PWR), an advanced light water reactor (A-LWR), a sodium fast reactor (SFR), and a high-temperature gas-cooled reactor (HTGR). A failure modes and effects analysis (FMEA) of the coupling system between the nuclear plant and the synthetic fuel systems is performed with the goal of identifying the reliability of such a thermal delivery system. Furthermore, a high temperature pathway is investigated for synfuel coupling to determine if this is more efficient and more cost effective as a coupling approach.
Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity
Building energy simulation is a critical tool for developing and testing advanced control strategies, such as Reinforcement Learning (RL), to provide demand flexibility and affordable energy costs. The recently introduced Smart Buildings Control Suite (sbsim) provides a lightweight, scalable, and data-calibrated simulation environment based on a 2D finite-difference model. However, the initial model primarily focused on conductive and convective heat transfer, neglecting the significant impact of long-wave radiative heat exchange between interior surfaces. This paper presents a significant extension to the sbsim framework by incorporating a physically-grounded model for interior radiative heat transfer. Our primary contribution is the development and integration of a fully tensorized radiative heat transfer module, which preserves the computational efficiency and scalability of the original simulator. This was achieved by developing a pipeline for view factor calculation, including an algorithm to identify directly seeing surfaces within complex floor plans, and formulating the net radiation equations for efficient execution on modern hardware accelerators. We validate the numerical accuracy of our tensorized implementation by comparing its results against a traditional iterative approach, demonstrating identical outcomes. This enhancement increases the physical fidelity of sbsim, enabling more accurate training of RL agents for building energy optimization.
This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.
Abstract Recently, membrane technology has gained significant traction as an energy-efficient alternative to traditional thermal processes for solvent recovery. Deep eutectic solvents (DESs) have emerged as sustainable alternatives to conventional organic solvents, yet a systematic methodology for selecting compatible membrane materials for their recovery remains underdeveloped. This study established a predictive framework for membrane material selection in hydrophobic DES applications using Hansen Solubility Parameters (HSP) with inverted criteria targeting materials with relative energy difference (RED) values greater than 1.0. Flat sheet membranes were fabricated via the non-solvent induced phase separation (NIPS) technique. Four NIPS fabricated polymer membranes were evaluated: polysulfone, cellulose acetate, polyvinylidene fluoride (PVDF) fabricated with polyethylene glycol (PEG) as a pore-forming agent, and polybenzimidazole (PBI). The HSP approach successfully predicted membrane-solvent compatibility, with polysulfone (RED = 0.6) and cellulose acetate (RED = 0.9) dissolving completely within 24 h, while PVDF (RED = 1.9) and PBI (RED = 1.1) maintained structural integrity throughout a 7-day exposure period. Furthermore, PVDF demonstrated superior performance with minimal weight gain (3.0%), hydrophobic surface characteristics (122° water contact angle), and enhanced mechanical properties following DES exposure. Comprehensive chemical and morphological characterization confirmed PVDF’s chemical stability and revealed a surface-selective interaction mechanism involving simultaneous PEG (pore-forming agent) extraction and DES component adsorption. Adsorption kinetics followed pseudo-first-order behavior with reversible characteristics, best described by the Temkin isotherm model (R² = 0.9987). PVDF membranes-maintained separation functionality with average lignin rejection (75.2 ± 7.69%) and demonstrated filtration permeability of 2.0 ± 0.34 LMH/bar. This methodology provides a rational approach for membrane selection in emerging solvent systems, contributing to the advancement of sustainable separation technologies for DES-based biomass processing applications.
Artificial heating in plasma simulations is a well-known phenomenon which occurs when, among other things, the Debye length is poorly resolved by the simulation mesh. Here, in this work, the degree to which numerical-heating occurs during a simulation of a nanosecond atmospheric pressure streamer discharge is examined. The streamer is simulated using a two-dimensional finite-element, particle-in-cell code Empire, which uses direct simulation Monte Carlo for binary particle interactions. Initially, an estimate of the numerical-heating rate applied to Empire is performed using a simple plasma model. Second, a positive atmospheric pressure streamer discharge simulation is performed to study the effects of numerical heating on plasma density, electron temperature, and streamer velocity. The nominal Debye length is approximately 1 μm and the amount of numerical heating introduced in the simulation is varied by using mesh sizes ranging from 2 μm to 20 μm. A measurable numerical heating quantity is proposed that can be used to estimate the appropriate element size and quantify the numerical-heating that can be expected over the simulation time for an atmospheric pressure streamer. In conclusion while Δx/λ D violations can be an issue it is not likely to be an issue with streamer discharges that are temporally short and occur in environments where collision frequencies are high. This result validates the rationale of grid size choices for a large amount of previously published works where Δx/λ D violation was not clearly addressed. Primary finding of this work is that numerical heating is of minor concern for plasma simulations where electron–neutral collisions are numerous such that multiple collisions can occur within a single plasma period.
In a nuclear reactor, prolonged exposure to high neutron flux levels can change material properties of reactor components. Due to the danger posed to personnel by highly radioactive components such as spent fuel, noncontact methods must be used to determine these properties. The objective of the current research is to test the viability of using a flash-heating method to determine the thermal diffusivity of a silicon carbide (SiC) tube, which could be used as cladding for a nuclear fuel rod. The flash-heating experiment was conducted at Oak Ridge National Laboratory and temperature results were analyzed as a two-Dimensional cross section which assumed axial symmetry. The model was fitted iteratively to the temperature measurements using nonlinear regression which required values for thermal diffusivity, Biot number and a term to determine the magnitude of the heat absorbed by the flash. The method could be expanded in the future to estimate the thermal diffusivity of spent nuclear fuel rods in an effort to increase the certainty of new reactor designs using precise thermal properties throughout the core life. A statistical analysis of the results of this work is provided as part of the analysis.