Search NASASearch

SEARCH · Search NASA

Results for “Heat Treatment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

266 records · Page 2

Bend Properties of Sapphire Fibers at Elevated Temperatures: Bend Survivability - 1

The effect of temperature on the bend radius that a c-axis-oriented sapphire fiber can withstand was determined for fibers of various diameter. Bend stress rupture tests were performed for times of 1-100 h and temperatures of 300-1700 C. Fibers would survive the bend test undeformed, would fracture or would deform. The bend survival radius was determined to be the radius above which no fibers fractured or deformed for a given time-temperature treatment. It was found that the ability of fibers to withstand curvature decreases substantially with time and increasing temperature and that fibers of smaller diameter (46-83 micron) withstood smaller bend radii than would be expected from just a difference in fiber diameter when compared with the bend results of the fibers of large diameter (144 micron). This was probably due to different flaw populations, causing high temperature bend failure for the tested sapphire fibers of different diameters.

Sapphire

Thermal Vacuum Testing of the Cryostat Heat Removal System for COSI SMEX

The Cryostat Heat Removal System (CHRS) of the Compton Spectrometer and Imager (COSI) consists of cryocooler, three transport aluminum ammonia Constant Conductance Heat Pipes (CCHP), three radiators with CCHP spreaders and Cryocooler Control Electronics (CCE) attached to a separate radiator. A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the integrated COSI CHRS in the flat configuration. This presentation summarizes the measured COSI CHRS performance along with lessons learned.

Pipes

Heat Flow and Thermal History of the Moon

An analysis was made of current heat flow data and thermal models of lunar evolution which satisfy the diverse information that has accumulated on internal processes.

Ye A Lyubimova

In-Situ Heat Rejection to the Martian Atmosphere

In order to provide in-situ heat rejection to the thin Martian atmosphere, approaches relying on forced convection and buoyancy flow are conceptualized. A convective radiator concept utilizing a fan to draw local atmosphere through an expanded metal foam heat exchanger panel is developed. To provide a pumped fluid loop interface, flow tubes are embedded in the heat exchanger panel and heat is transferred from the tubes to the foam via conduction and subsequently convectively to the environment. To forgo the use of a specialized high throughput fan, a concept utilizing a buoyant chimney tower to draw atmospheric flow through a low pressure drop heat exchanger is also considered. Both concepts may best align with moderate- to high-temperature heat loads that provide a significant delta temperature relative to the ambient atmosphere temperature. While eliminating dust accumulation on radiator surfaces, some type of serviceable filtration or screening may be required to prevent accumulation of dust inside the expanded metal foam heat exchanger for both concepts.

Heat Rejection

Using Satellite Surface Temperature Data to Monitor Urban Heat Island

Exposure to heat is a growing concern nationwide. Temperatures can be elevated in cities compared to surrounding rural areas, referred to as an “urban heat island” (UHI) effect, which is intensified during heat waves. The lack of dense networks of air temperature measurements results in few studies on urban heat. Now, a vast amount of high spatial and temporal satellite data on land surface temperature is available. We identified satellite datasets with the longest surface temperature records but different spatial and temporal resolutions: Landsat (1985-current, biweekly at 60 m and 100 m spatial resolution) and the Moderate Resolution Imaging Spectroradiometer (MODIS) data from the Terra and Aqua satellites (2000-current, daily at 1 km spatial resolution). We investigated how satellites with different spatial and temporal resolutions detect UHI effects differently. We hypothesized that 1) a dataset’s spatial resolution impacts the precision of detected UHIs spatially, since high spatial resolution Landsat data better captures spatial variability in temperature, and 2) daily surface temperature data can detect temporal patterns of UHIs and heatwave frequencies. We analyzed Landsat and MODIS satellite data in the Washington, D.C. and Baltimore region. We found that Landsat describes higher spatial variability of the UHI effect than MODIS data. However, MODIS data shows more consistent seasonal surface temperature patterns than Landsat when compared to in situ air temperature measurements. MODIS data was also able to consistently measure the frequency of heat waves. This study demonstrates the value of NASA satellite data for urban heat and climate change studies.

landsat

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water