Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat exchanger fouling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Header Design for Diffusion Bonded Heat Exchangers

Microchannel heat exchangers have seen increasing adoption in many high-pressure applications in recent decades but are subject to particulate fouling from the relatively small channel size compared to traditional designs. Typical cleaning methods require process shutdown, heat exchanger removal, cleaning, then reassembly. The objective of this project was to refine and transfer technology to enable header design improvements for Cleaning-in-Place (CIP), allowing for reduced/negligible process interruption for the cleaning process. The technology transfer was from Sandia National Laboratories (Sandia) to Vacuum Process Engineering, Inc. (VPE). This primary purpose of CIP was developed while considering channel flow uniformity and heat exchanger cost. The project phases were to 1) capture and define potential improvement options, 2) evaluate options with both simulation and experiments, and 3) transfer design knowledge to the industry partner. These efforts resulted in improved header designs from the first known focused effort in this area. The improved designs will help the entire microchannel heat exchanger field that has applications in supercritical CO 2 power cycles, hydrogen (fuel cell) vehicle fueling, liquified natural gas processing, and more.

42 ENGINEERING↗

Advances in high-pressure and high-temperature heat exchangers: Innovations via additive manufacturing and their applications

This paper provides a comprehensive overview of technological developments and applications for high-pressure and high-temperature (HPHT) heat exchangers produced through additive manufacturing (AM) techniques. As the demand for high-efficiency energy systems has been rising, the role of heat exchangers for thermal management and transport is becoming increasingly crucial. In this context, AM has emerged as a promising manufacturing solution to address the challenges posed by higher operating temperatures and/or pressures. This paper delves into three primary areas: the exploration of HPHT regimes supported by conventional heat exchangers, the impact of AM processes on thermal transport devices, and the discussion focused on HPHT heat exchangers produced via AM. The study examines the traditional manufacturing processes, materials, structures and geometries, and limitations of the commonly used heat exchangers for HPHT applications. Furthermore, it highlights the potential of AM in optimizing HPHT heat exchanger design, by reviewing studies that enable uniform flow distribution, minimization of fouling, and thermo-hydraulic performance augmentation without compromising structural stability. While addressing the limitations of cost, size, and other constraints, this study offers insights into the possibilities of AM in revolutionizing HPHT heat exchanger technology. The goal has been to fill the gap in literature by summarizing key studies, findings, and limitations, presenting a detailed examination, and proposing new areas for research. In conclusion, this review contributes to a deeper understanding of AM’s role in advancing HPHT heat exchangers for future energy systems.

36 MATERIALS SCIENCE↗

A Computational Fluid Dynamic Study on Polymer Heat Exchangers

Polymer heat exchangers have been developed for the applications involving weight restrictions or chemical compatibility and fouling issues owing to the low density, anticorrosive properties, and low thermal expansion of polymers. Recently development of additive manufacturing also brings new opportunities to make polymer heat exchangers with desired design that was hard to realize before. However, due to the lower thermal conductivity polymer composite, the overall heat transfer performance is still a challenge in the polymer heat exchanger technology. In present work, a computational fluid dynamic (CFD) model has been developed to study the overall heat transfer performance of additively manufactured polymer heat exchangers. The CFD results offer an insight of fluid flow and temperature distribution in the polymer heat exchangers. This study provides a guidance not only on the polymer material selection but also on the design of polymer heat exchangers. The conclusions will be helpful to design a polymer heat exchanger whose overall heat transfer performance is comparable to a metal heat exchanger.

Zhang, Mingkan↗

Apparatus and method for intrachannel defouling of a heat exchanger using induction heaters

An apparatus comprising a heat exchanger and one or more induction heating elements is disclosed. The heat exchanger comprises a coolant side conduit and a process side conduit, the process side conduit being susceptible to fouling by at least partial desublimation, condensation, crystallization, deposition, or combinations thereof of a fouling component of a circulating process fluid. An electrically conductive first metal is disposed adjacent to the process side conduit. The one or more induction heating elements are disposed proximate to the heat exchanger. The one or more induction heating elements are connected to a source of electrical current. When the electrical current flows through the induction heating elements, eddy currents are induced in the first metal, heating the first metal such that the fouling component sublimates, melts, absorbs, or a combination thereof into the circulating process fluid.

42 ENGINEERING↗

Effects of Temperature on Flow Fouling of Smooth and Nonwetting Surfaces

Mineral fouling (scaling) of heat transfer surfaces is a pervasive problem in heat exchangers, chemical reactors, and other equipment in energy, environmental, and process industrial applications. Many of the applications involve dynamic flow of fluids with the impurity minerals and, furthermore, operate at elevated temperature. Strategies to mitigate fouling under these conditions are of much value in industrial applications. This paper presents a comparative study of temperature-dependent mineral fouling deposition on smooth surfaces and nonwetting superhydrophobic and lubricant-infused surfaces under dynamic flow conditions. The surfaces are represented in a unified manner using the viscosity ratio of the infused material within the porous asperities on a surface to that of the flowing fluid such that the spectrum of surfaces from superhydrophobic to smooth is captured by the range of viscosity ratios from 0 to ∞. Using a forced convection experimental setup, deposition of calcium sulfate on the surfaces is quantified in terms of asymptotic fouling resistance over a range of temperature, Reynolds number, and mineral foulant supersaturation. Through a systematic set of accelerated fouling experiments, an empirical relationship for the asymptotic fouling resistance is developed in terms of Reynolds number, foulant concentration, temperature, and surface type. The empirical model is validated with a comprehensive set of experimental data from this study as well as from the literature. Optimum nonwetting surface designs for minimizing fouling resistance compared to conventional smooth surfaces are developed as a function of temperature. The results of the study offer insight into the temperature-dependent fouling of surfaces under flow conditions and a rational design of fouling-resistant nonwetting surfaces that can be readily translated to practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of surface roughness/wettability pattern effect on crystallization fouling over falling-film flow

In many industries, including desalination, scaling in heat exchangers is a persistent issue, and most methods of scaling control involve environmentally hazardous chemical additives. Exploiting the effects of surface features and flow-imposed shear on salt deposition might introduce a new approach to scale management, opening the possibility of self-cleaning surfaces. In this work, we experimentally explore surface roughness and wettability patterns interaction with salt deposition and flow shear. Heat transfer and scale mass deposition on flat surfaces are measured during thin-film evaporation of calcium sulfate solution. A wide range of surface roughness (0.027–2.66 μm) is studied at fixed flow and heat flux conditions. Due to improved mixing, heat transfer is enhanced with rougher surfaces initially; however, degrades more quickly than smoother surfaces. Following a period of initial mass deposition fluctuation, a steady scaling stage is observed, with rough surfaces scaling more than smooth surfaces. Wettability patterned surfaces can suppress crystal nucleation without sacrificing overall surface wetting, resulting in antifouling performance and heat transfer enhancement. Scale mass deposition on a patterned surface is reduced by 60 %, and 27 % heat transfer improvement over the baseline surface is found. Furthermore, this study provides guidance to surface manipulation for heat transfer improvement and fouling mitigation.

42 ENGINEERING↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Additively manufactured polymer composites for heat exchanger applications: evaluation of critical thermophysical properties

Polymeric heat exchangers (PHXs) have been used in applications involving weight restrictions, chemical compatibility, and fouling issues. Additive manufacturing (AM) or 3D printing provide new solutions to previously inaccessible combinations of properties and geometries. There are some advancements in the PHXs by AM; however, the process and the properties of materials still need further investigation to improve the overall performance. In this study, additively manufactured polyethylene terephthalate glycol (PETG) composites reinforced with graphite and pitch-based carbon fibers were evaluated for their potential application as PHXs. The thermal conductivity, volumetric heat capacity, coefficient of thermal expansion, creep behavior, and long-term performance were studied in detail. Our results reveal that the composites have an anisotropic thermal conductivity. The thermal conductivity along the printing direction is higher than the layer building direction due to the shear-induced alignment of the fillers. The printed composites achieve good thermal stability with 80% lower CTE at room temperature than neat PETG. Creep tests suggest the creep and creep recovery were highly temperature-dependent, and the deformation can be recovered when the temperature is below glass transition. These results suggest additive manufactured composites be potentially used for heat exchanger applications at low temperatures.

36 MATERIALS SCIENCE↗

Heat Transfer of an Integrated Counterflow Ceramic Heat Exchanger

The ceramic-based heat exchanger is one of the leading contenders for high-efficiency concentrating solar power plants using a molten salt heat transfer fluid and a supercritical carbon dioxide Brayton power cycle operating at temperatures above 700 °C due to the excellent resistance of ceramics to corrosion, oxidation, erosion, creep, and fouling. In the present study, the thermal performance of a ceramic silicon carbide prototype heat exchanger, with semi-elliptical heat transfer channels, integrated header channels, and a counterflow configuration fabricated by using binder jetting additive manufacturing, was experimentally investigated. Experimental heat transfer tests of the prototype were conducted at high temperatures and under various test fluid flow rates and inlet temperatures. The experimental heat transfer rates compared favorably with simulation predictions.

Yu, Wenhua (ORCID:0000000219457014)↗

Ultra-compact and efficient heat exchanger for solar desalination with unprecedented scaling resistance

The objective is to design, prototype, and test a heat exchanger technology with an efficiency improvement of more than 150% compared to state-of-the-art heat exchanger technology (UA/volume), with significantly improved fouling/scaling resistance at elevated temperatures (>120°C) when compared to existing technology where scaling is a major performance-limiting issue, as well as at lower operating-temperatures (~63-110°C). We now report our overall progress on the project. An ultra-compact, efficient heat exchanger geometry has been developed that can maximize surface-area-to-volume ratio so that proposed target (UA/volume). Advanced manufacturing techniques, such additive manufacturing, have made it possible to create complex structures cost effectively. In addition to traditional manufacturing methods, additive manufacturing has been successfully used for the development of high-performance geometries. These methods allow the ability to create custom surface textures, which are deployed to dramatically control wettability and create energy-gradient surfaces. These techniques allow fouling/scaling nucleation to be spatially controlled, such that as the fouling layer grows it will be broken and removed by flow forces.

42 ENGINEERING↗

Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Durable and Low-Cost Fractal Structured Multifunctional Coatings for Next-Generation CSP

Fractal coatings on various low-cost and high-temperature metallic substrates such as SS316, SS347, In800H, In740H, In625, Haynes 230, etc. were fabricated employing our patented novel electrodeposition process at various deposition potentials and deposition times, as well as chemical etching. The best combination of the materials and processing conditions were co-optimized for the reliable and repeatable fabrication of the multifunctional coatings. Surface morphologies were examined using SEM and AFM, and fractal characterization was done using a 3D optical surface profiler. Fractal dimension was used to identify successful fabrication and material parameters. The mechanical durability of the coatings was evaluated using several standardized tests, such as sand abrasion (ASTM D968) and adhesion (ASTM D3359), to fully characterize and demonstrate the mechanical durability of the fabricated surfaces. HTF immersion tests on the fractal multifunctional coatings were conducted based on a modification of the ASTM D870, which is established for static water immersion testing. To calculate the corrosion rates and descaled weight loss of the samples subjected to thermal exposure for different time durations (100 h, 300 h, 500 h, and optionally 750 h) to estimate the corrosion rate. While protecting the substrates from corrosion is an important goal, an allied goals is also to examine the post-corrosion temperature stability and properties of the molten salts themselves due to the dissolution of the constituents of the alloys and the corrosion products from the coatings that cause “fouling” of the molten salts. Fouling characteristics of the different molten salt HTFs exposed to coated and uncoated substrates were investigated. Finally, considering a prototype molten salt/sCO2 heat exchanger, cost/performance model is developed to demonstrate that the coatings on low-cost alloys such as stainless steel provide lower levelized cost of heat exchanger compared to high nickel content Ha230.

14 SOLAR ENERGY↗

Method for condensing a CO2 vapor stream beyond the frost point

A method for cryogenic cooling without fouling is disclosed. The method comprises providing a first cryogenic liquid saturated with a dissolved gas; expanding the first cryogenic liquid into a separation vessel, separating into a vapor, a second cryogenic liquid, and a first solid; drawing the vapor into a heat exchanger and the second cryogenic liquid and the first solid out of the separation vessel; cooling the vapor against a coolant through the heat exchanger, causing the vapor to form a third cryogenic liquid and a second solid, the second solid dissolving in the third cryogenic liquid; and combining the second cryogenic liquid and the first solid with the third cryogenic liquid, producing a final cooled slurry. In this manner, the cryogenic cooling is accomplished without fouling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Enhancing Steam-Side Heat Transfer via Microdroplet Ejection using Inorganic Coatings

During condensation of water on a superhydrophobic nanostructured surfaces, droplets coalesce and jump (droplet ejection) due to the release of excess surface energy. Meticulously designed nanostructured surfaces or coatings capable of droplet ejection can enhance heat transfer performance by easy removal of droplets during condensation. In the present work, the capabilities of the Nelumbo droplet ejection coatings technology currently used in commercial heat exchangers are explored and optimized for materials and conditions relevant to steam condensers. Specifically, this includes (1) adapting and optimizing the procedures and chemistries to deposit droplet ejecting coatings on materials used in the steam condenser, (2) testing of the heat transfer, durability, and fouling of the fabricated coatings under a variety of steam condenser relevant conditions, and (3) modeling of the impact of droplet dynamics and interfacial properties on heat transfer in steam condensers. We experimentally demonstrated that at low supersaturation conditions (S~1.02), developed superhydrophobic nanostructured surface gives a 40% higher peak heat transfer flux and a 17% higher peak overall heat transfer coefficient (U) with droplet ejection mechanism compared to the dropwise condensation mechanism on the same nanostructured surface. Though the experimentally observed droplet ejection mechanism was short-lived (~3 min) due to the limitation of the chiller to maintain a constant supersaturation condition in fabricated steam condenser. And large variations in water inlet temperature (+ to - 2 degrees C) caused flooding of nanostructure (Wenzel state) at higher supersaturation (S > or = 1.12). This is an important finding because typical supersaturation levels in field operation are over 1.8 and as such, either the flooding potential for these materials should be improved or operation at lower supersaturation may be required to maximize heat transfer efficiency. If supersaturation conditions can be maintained reliably in the steam condenser in addition to droplet ejection mechanism during condensation, this could provide a potential 2% reduction in water flow rate which equates to a savings of over 3900 gallons of water per minute for a 500 MW steam turbine and over $0.3MM savings annually given a 0.02 cent marginal water withdrawal cost. It is also worth noting that these savings are based on improvement of droplet ejection coatings over coatings capable of performing consistent dropwise mechanism in in-field surface condensers. Savings due to the droplet ejections coatings when compared to bare substrates could be much higher. Additionally, the present work provides the importance of steam condenser operating conditions and insights into the challenges in modeling the condensing droplet dynamics on surfaces.

20 FOSSIL-FUELED POWER PLANTS↗