Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

50-kWth methane/air chemical looping combustion tests with commercially prepared CuO-Fe 2 O 3 -alumina oxygen carrier with two different techniques

CuO-Fe 2 O 3 /alumina oxygen carriers were manufactured using two different techniques (i.e., spray drying and wet granulation). The spray drying method produced porous, spherical particles in the range of 100–200 µm. The wet granulation, or tumbling method, produced particles in the range of 200–600 µm. Both batches of material showed good gas conversion and particle durability during tests in NETL’s 50-kWth chemical looping circulating fluidized bed combustor unit at 700–900 °C. No agglomeration was observed, even though the oxygen carrier had a high CuO concentration (30%). The particle losses with 200–600 µm batch were significantly lower than that with the 100–200 µm batch. The oxygen carrier materials in the 200–600 µm range were circulated for approximately 3.1 days in the target temperature range (700–850 °C) and a total of approximately 40 h of chemical looping combustion testing was conducted during that time. The average fuel reactor temperatures ranged from 760 to 815 °C for the chemical looping combustion test periods, and the average air reactor temperature ranged from 840 to 915 °C. The fuel conversion from natural gas to CO 2 ranged from 50 to 80%. Approximately 1.6 h of continuous operation was achieved with no gas preheat and no natural gas augmented heating. During this test period, the average fuel reactor temperature ranged from 780 to 825 °C, the air reactor temperature ranged from 930 to 960 °C, and the natural gas to CO 2 conversion ranged from 50 to 65%. Finally, analysis of the oxygen carrier after the test indicated that there were no significant changes in the particle size or the surface morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring Surface Roughness Using Additive Manufacturing to Improve Internal Cooling

Abstract Surface roughness present on internal cooling channels produced with additive manufacturing has been previously shown to augment heat transfer and pressure loss to levels similar to traditionally cast turbulators. Given the ability of the surface roughness to improve the cooling performance of small cooling channels, the question arises on whether there is an optimal combination of random roughness features to maximize internal cooling performance. To investigate this question, test coupons with different surface roughness morphologies and magnitudes were manufactured by manipulating the parameters in the laser powder bed fusion additive manufacturing process. The coupons were tested to characterize the friction factor and Nusselt number of the cooling channels over a range of Reynolds numbers. Results showed that certain roughness combinations outperformed others, increasing the internal cooling performance of the channels. Additionally, manipulation of the performance using the process parameters allowed for reductions in build time, which could be useful for controlling component cost.

Engineering↗

Traction Drive Inverter Cooling with Submerged Liquid Jet Impingement on Microfinned Enhanced Surfaces (Presentation)

Jet impingement is one means to improve thermal management for power electronics in electric-drive traction vehicles. Jet impingement on microfin-enhanced surfaces further augments heat transfer and thermal performance. A channel flow heat exchanger from a commercial inverter was characterized as a baseline system for comparison with two new prototype designs using liquid jet impingement on plain and microfinned enhanced surfaces. The submerged jets can target areas with the highest heat flux to provide local cooling, such as areas under insulated-gate bipolar transistors and diode devices. Low power experiments, where four diodes were powered, dissipated 105 W of heat and were used to validate computational fluid dynamics modeling of the baseline and prototype designs. Experiments and modeling used typical automotive flow rates using water-ethylene glycol as a coolant (50%-50% by volume). The computational fluid dynamics model was used to predict full inverter power heat dissipation. The channel flow and jet impingement configurations were tested at full inverter power of 40 to 100 kW (output power) on a dynamometer, translating to an approximate heat dissipation of 1 to 2 kW. With jet impingement, the cold plate material is not critical for the thermal pathway. A high-temperature plastic was used that could eventually be injection molded or formed, with the jets formed from a basic aluminum plate with orifices acting as nozzles. Long-term reliability of the jet nozzles and impingement on enhanced surfaces was examined. For jet impingement on microfinned surfaces, thermal performance increased 17%. Along with a weight reduction of approximately 3 kg, the specific power (kW/kg) increased by 36%, with an increase in power density (kW/L) of 12% compared with the baseline channel flow configuration.

30 DIRECT ENERGY CONVERSION↗

Review of heat transfer enhancement techniques in two-phase flows for highly efficient and sustainable cooling

We show that two-phase internal flow is ubiquitous to many systems due to its ability to transfer large amounts of heat effectively. Recent advances motivated by sustainability have pushed towards augmenting the heat transfer between the tube and the two-phase working fluid. Augmenting heat transfer in two-phase flows enables process intensification, and compactness leading to reduced cost and material consumption. This review investigates the effect of heat transfer enhancement techniques on different fluids including R134a, R407C, R22, etc … The techniques are categorized into passive and active and focus on durable enhancement methods which do not include surface structuring or coating. Passive techniques utilize geometrical and surface modifications to induce better mixing. Several passive techniques are analyzed including fins, inserts, and more. In analyzing these techniques, the effect of changing geometric parameters is studied, and the limitations are highlighted. Further, active techniques that enable heat transfer enhancement through applying power are also investigated. Electrohydrodynamic approaches are analyzed and compared to passive techniques. Additionally, the implications of heat exchange enhancement in the context of global energy are discussed. An energy analysis discretized by the use sector is conducted, with an emphasis on predicting the future potential for renewable and sustainable development. Moreover, although active approaches provide the highest heat transfer enhancement, due to implementation difficulties, passive techniques are more frequently adopted. The review ends with discussion of next-generation heat exchangers which will rely more on additive manufacturing due to its flexibility and reduced cost per part as the technology matures.

Nusselt number↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

The dimethylthiourea-induced attenuation of cisplatin nephrotoxicity is associated with the augmented induction of heat shock proteins

Dimethylthiourea (DMTU), a potent hydroxyl radical scavenger, affords protection against cisplatin (CDDP)-induced acute renal failure (ARF). Since the suppression of oxidative stress and the enhancement of heat shock proteins (HSPs) are both reported to protect against CDDP-induced renal damage, we tested whether increased HSP expression is involved in the underlying mechanisms of the DMTU-induced renal protection. We examined the effect of DMTU treatment on the expression of HSPs in the kidney until day 5 following a single injection of CDDP (5 mg/kg BW). DMTU significantly inhibited the CDDP-induced increments of serum creatinine, the number of 8-hydroxyl-2'-deoxyguanosine (8-OHdG)- and terminal deoxynucleotidyl transferase nick-end labeling (TUNEL)-positive tubular cells, and tubular damage score (p < 0.05). CDDP significantly increased renal abundances of HO-1, HSP60, HSP72 and HSP90 at days 1, 3, and 5. DMTU significantly augmented only the expression of HSP60 expression mainly in the cytoplasm of the proximal tubular cells at days 1 and 3 in CDDP-induced ARF. DMTU also inhibited the CDDP-induced increment of Bax, a pro-apoptotic protein, in the fraction of organelles/membranes at day 3. The findings suggest that DMTU may afford protection against CDDP-induced ARF, partially through the early induction of cytoplasmic HSP60, thereby preventing the Bax-mediated apoptosis in renal tubular c0010el.

60 APPLIED LIFE SCIENCES↗

What Drives Upper-Ocean Temperature Variability in Coupled Climate Models and Observations?

Abstract A key question in climate modeling is to what extent sea surface temperature and upper-ocean heat content are driven passively by air–sea heat fluxes, as opposed to forcing by ocean dynamics. This paper investigates the question using a climate model at different resolutions, and observations, for monthly variability. At the grid scale in a high-resolution climate model with resolved mesoscale ocean eddies, ocean dynamics (i.e., ocean heat flux convergence) dominates upper 50 m heat content variability over most of the globe. For deeper depths of integration to 400 m, the heat content variability at the grid scale is almost totally controlled by ocean heat flux convergence. However, a strong dependence on spatial scale is found—for the upper 50 m of ocean, after smoothing the data to around 7°, air–sea heat fluxes, augmented by Ekman heat transports, dominate. For deeper depths of integration to 400 m, the transition scale becomes larger and is above 10° in western boundary currents. Comparison of climate model results with observations show that the small-scale influence of ocean intrinsic variability is well captured by the high-resolution model but is missing from a comparable model with parameterized ocean-eddy effects. In the deep tropics, ocean dynamics dominates in all cases and all scales. In the subtropical gyres at large scales, air–sea heat fluxes play the biggest role. In the midlatitudes, at large scales >10°, atmosphere-driven air–sea heat fluxes and Ekman heat transport variability are the dominant processes except in the western boundary currents for the 400 m heat content.

54 ENVIRONMENTAL SCIENCES↗

Warming-Induced Biome Change at the Temperate-Boreal Ecotone: An Experimental Test of Key Regeneration Processes (Final Technical Report)

This project advanced our understanding of plants’ key physiological and ecological processes that are essential to the survival, success, and carbon cycling of plants from the boreal-temperate forest ecotone in the future climate. A primary goal of the project was to test the effect of warming and water limitation on plants from the Boreal-Temperate Ecotone using a realistic outdoor long-term experiment. Plant at this ecotone is predicted to be particularly sensitive to future climate since the ecotone represents a relatively sharp boundary between many temperate species to the south and boreal species to the north. This work was important, as there was and still is a significant uncertainty surrounding the mechanisms of future climate effects on vegetation compositional and carbon cycling change, especially in forests mostly due to lack of experimental examination of response to warming and limited water availability. Consequently, we tested our central objective, that was to assess the potential for projected climate to alter tree species composition and carbon cycling at the southern boreal-temperate forest ecotone by experimentally warming forest plots and documenting effects on establishment and juvenile performance for tree species near their warmer (boreal species) and colder (temperate species) range limits in northern Minnesota. To accomplish our goals, we designed and built a successful highly manipulative experiment that implemented vegetation-soil warming and rainfall removal in both understory and open habitats at two sites in northern Minnesota (MN). The sites lie at different distances to the north of the ecotone between the southern boreal and northern temperate forest biomes. We focused on ten target species, all of which are near their warmer (Pinus banksiana, Picea glauca, Abies balsamea, Populus tremuloides, Betula papyrifera) or colder (Pinus strobus, Quercus macrocarpa, Quercus rubra, Acer rubrum, Acer saccharum) range edge in northern MN; we also studied other species such as a woody invader and native herbs and shrubs. Three temperature treatments (ambient, +1.7°C, +3.4°C) were imposed using infra-red heating lamps augmented with soil heating cables to simultaneously control soil and vegetation temperatures, enabling assessment of non-linear responses. These temperatures bracket the range of anticipated warming in the region during the next 75-100 years. In addition, we implemented summer rain removal treatment mimicking predicted distribution in precipitation patterns by future climate where we actively removed ~40% of rainfall. Measurements included germinant establishment, plant growth, phenology, physiology and survival, soil, plant and air temperature, soil moisture and nutrient status. These measures enabled us to assess how germination, growth and survival at the establishment stage are influenced by direct climate effects and/or indirect effects of warming, soil resources such as water and nutrients availability or other environmental variables that either directly or indirectly influence plant performance.

60 APPLIED LIFE SCIENCES↗

Concurrent Optimization of Capital Cost and Expected O&M

Concentrating solar power (CSP) technologies can utilize heat from concentrated sunlight from a field of tracking mirrors to generate electricity, reform fuel, provide process heat, or augment fossil plant heat sources. Electricity-generating power tower systems focus light from thousands of independent heliostats onto a thermal receiver, which uses the focused light to warm a heat transfer fluid (HTF), typically, a molten nitrate salt. The HTF is then sent to a power generation cycle or diverted into thermal energy storage (TES) for later use. Thermal storage is – in principle – a straightforward proposition. However, optimal utilization of a TES resource is complex and multi-faceted: thermal energy may be dispatched to produce electricity immediately upon first availability, or thermal energy may be reserved for next-day peak periods at risk of filling storage and dumping energy, or a portion of the thermal energy can be reserved to maintain equipment temperatures, reducing power cycle startup time, etc. Many possible dispatch permutations variously emphasize producing peak power, operating through transients, expediting daily startup, etc. The best operation strategy can change day-to-day throughout the year, depending on the weather and market pricing forecasts. The project we describe in this report develops a software package that allows users to explore design optimization, operations decisions, and performance characterization of concentrating solar power tower plants. Users interface with the tool through a scripting language, and results are reported in time series tables, plots, runtime logs, and design outputs. Users choose from a list of variables such as tower height, solar multiple, design-point irradiance, thermal storage size, etc., and specify information about the system using a list of parameters. The software can then optimize the specified variables to reduce the cost of energy produced by the system while meeting certain production requirements, accounting for uncertain weather and electricity price forecasts, and correcting for equipment failures or repair time. The software we develop is the first comprehensive design tool of its kind to incorporate all of these aspects while being deployed as open source.

14 SOLAR ENERGY↗

Westinghouse Small Modular Reactor passive safety system response to postulated events

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor. This paper is part of a series of four describing the design and safety features of the Westinghouse SMR. This paper focuses in particular upon the passive safety features and the safety system response of the Westinghouse SMR. The Westinghouse SMR design incorporates many features to minimize the effects of, and in some cases eliminates the possibility of postulated accidents. The small size of the reactor and the low power density limits the potential consequences of an accident relative to a large plant. The integral design eliminates large loop piping, which significantly reduces the flow area of postulated loss of coolant accidents (LOCAs). The Westinghouse SMR containment is a high-pressure, compact design that normally operates at a partial vacuum. This facilitates heat removal from the containment during LOCA events. The containment is submerged in water which also aides the heat removal and provides an additional radionuclide filter. The Westinghouse SMR safety system design is passive, is based largely on the passive safety systems used in the AP1000{sup R} reactor, and provides mitigation of all design basis accidents without the need for AC electrical power for a period of seven days. Frequent faults, such as reactivity insertion events and loss of power events, are protected by first shutting down the nuclear reaction by inserting control rods, then providing cold, borated water through a passive, buoyancy-driven flow. Decay heat removal is provided using a layered approach that includes the passive removal of heat by the steam drum and independent passive heat removal system that transfers heat from the primary system to the environment. Less frequent faults such as loss of coolant accidents are mitigated by passive injection of a large quantity of water that is readily available inside containment. An automatic depressurization system is used to reduce the reactor pressure in a controlled manner to facilitate the passive injection. Long-term decay heat removal is accomplished using the passive heat removal systems augmented by heat transfer through the containment vessel to the environment. The passive injection systems are designed so that the fuel remains covered and effectively cooled throughout the event. Like during the frequent faults, the passive systems provide effective cooling without the need for ac power for seven days following the accident. Connections are available to add additional water to indefinitely cool the plant. The response of the safety systems of the Westinghouse SMR to various initiating faults has been examined. Among them, two accidents; an extended station blackout event, and a LOCA event have been evaluated to demonstrate how the plant will remain safe in the unlikely event that either should occur. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing Cornell’s future geothermal district heating performance through systems engineering and simulation

Cornell University’s intention to lower its carbon footprint has motivated this engineering evaluation of using low-temperature geothermal energy to supply heat to the campus district energy system. Optimal selection and operation of heat pumps can significantly improve system performance. To support this analysis, we model the quantitative relationships between heat pump configurations and source flow, supply and distribution temperatures, facility heating design options, output heat generation, and carbon abatement outcomes. A systems approach is used for analysis, troubleshooting, and improvement of the model. The result of this effort is a dynamic tool that appropriately responds to hourly thermal demand and communicates energy response for techno-economic analysis. Simulations indicate that a single well-pair in the local Basement Contact Zone reservoir can satisfy almost 68% of annual thermal demand at nearly 20 MWth average capacity while remaining financially competitive compared to conventional heating with levelized cost of heating (LCOH) as low as $4.55/MMBTU ($15.53/MWh th ). A direct-use scheme with heat pump augmentation provided more carbon abatement and 50 to 150% more annual heat supply than one without augmentation. Exploration of three and four well-pair scenarios prove the capability to achieve 50 MW th baseload heating capacity with competitive LCOH and significant carbon reductions.

15 GEOTHERMAL ENERGY↗

Investigation of Gas Turbine Internal Cooling Using Supercritical CO 2 —Effect of Surface Roughness and Channel Aspect Ratio

In this paper, an experimental and numerical investigation of internal cooling channels with rib turbulators is presented with sCO 2 as the working fluid at process conditions (pressure-20.7 MPa and temperature up to 150 °C). The effect of channel aspect ratio up to 2:1 on thermal-hydraulic performance is explored in additively manufactured rectangular channels and square channels, both with and without 60 deg ribs on the top and bottom sides. The Wilson-plot method is employed to experimentally measure channel-averaged Nusselt number over a Reynolds number range up to 370,000. The friction factor is calculated from pressure drop and mass flow rate and additionally, the overall thermal performance factor (TPF) is reported. A companion computational fluid dynamics (CFD) simulation is performed for the rib turbulated cooling configurations reported in the experiments using the Reynolds average Navier–Stokes-based turbulence model. The objective of the numerical study is to gain insight into the local heat transfer augmentation in the ribbed channels as a result of varying the aspect ratio, channel configuration (square versus rectangular), operating conditions (Reynolds number) and the surface roughness, an inherent outcome of the additive manufacturing process. Surface roughness is simulated using sand grain roughness height (K S ) calculated from the experimental data, and a comparison is presented with the corresponding channel configuration with varying surface roughness heights starting from smooth surfaces (K S = 0). Experimental results indicate that the heat transfer augmentation is negligible in the rectangular channels with ribs on the long side compared to the square channel. However, it is enhanced by 60% in comparison to placing ribs on the shorter side. The TPF remains constant at around 1 for the entire range of Reynolds numbers consistent with prior work at the National Energy Technology Laboratory (NETL). Here, the simulation results highlight that increased surface roughness can have a favorable considerable influence on Nusselt number and overall thermal performance enhancement.

42 ENGINEERING↗

Augmentation of pool boiling heat transfer on tube bundles using metal foam

Pool boiling on a tube bundle is one of the most important heat transfer modes in several industrial applications, including steam generators, shell and tube heat exchangers for waste heat recovery, and desalination. Although several enhanced tubes (e.g., external micro-finned tubes) have been extensively studied and commercialized, the studies that pertain to the metal foam enhanced tube bundles are limited in the open literature. The objective of the present study is to perform an experimental study to analyze the pool boiling heat transfer characteristics of a metal foam tube bundle and compare its performance with that of a tube bundle with no enhancement. The performance of the metal foam tube bundles with different porosities (81%, 75%, and 62%) is compared against the conventional bare tube bundle. The results showed that the heat transfer coefficients of the metal foam tube bundles are 100–212% higher than those of the bare tube bundle. Among the different porosities, metal foam with 75% porosity showed a higher heat transfer coefficient. Furthermore, the wall temperature of the metal foam tubes is nearly 5–14⁰C lower than that of the bare tubes. In conclusion, when compared with a tube pitch of 25.4 mm, a tube pitch of 19.05 mm showed a maximum of 9% and 14% enhancement in bare and metal foam tube bundles, respectively.

42 ENGINEERING↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗

Sleeve reaction chamber system

A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conventional Rib Turbulators For SCO 2 Turbine Internal Cooling (Report)

This report documents experimental work in the NETL Heat Exchange and Experimental Testing (HEET) rig. The heat transfer performance of additively manufactured internal cooling features in supercritical CO 2 were characterized. It was demonstrated that the thermal performance factor of conventional angled rib turbulators remains independent of Reynolds number up to 3.1 x 10 5 indicating that these features may be employed to enhance heat transfer in sCO 2 turbine blades and vanes. This augmentation of heat transfer in the internal cooling passages decreases the required turbine coolant and improves the power cycle efficiency.

20 FOSSIL-FUELED POWER PLANTS↗

Experimental Study on Portable Air-Conditioning System with Enhanced PCM Condenser

A portable personal air-conditioning system with a vapor compression cycle (VCC), electrical battery, and thermal battery is an attractive option for localized cooling as compared with stationary air-conditioning systems. A phase change material (PCM) can be used for storing waste heat from the VCC condenser, thereby acting as a thermal battery. In the PCM condenser, copper tubes are submerged in the PCM container. Due to the low thermal conductivity of pure PCM, the overall heat transfer coefficient of the PCM condenser is limited resulting in high VCC condensing pressure and thus, low VCC coefficient of performance (COP). Therefore, it is necessary to improve VCC system performances by applying heat transfer augmentation in PCM. In this work, a portable air-conditioning system with heat transfer enhanced PCM that stores heat from condenser during VCC operation and is regenerated by a thermosyphon operation is proposed. The system also includes a receiver to address the charge difference between the thermosyphon and the VCC operation. The paper experimentally studies the effects of the following three types of enhanced PCM condensers on the system performance: (1) copper mesh enhanced PCM with helically coiled copper tube branches and large refrigerant distribution headers (CMPHX), (2) graphite matrix enhanced PCM with straight copper tube branches and small headers (GMPHX1), and (3) graphite matrix enhanced PCM with straight copper tube branches and large headers (GMPHX2). Results show that this system operates properly and effectively during both VCC and PCM regeneration operations. The system can provide four hours of continuous cooling, and the PCM can be fully regenerated after 7.4 hours by thermosyphon operation. The comparisons of three PCM condensers indicate that the system with GMPHX2 performs the best with the average VCC COP of 4.7. The VCC system with CMPHX has an average COP of 4.2, and GMPHX1 has an average COP of 3.1. GMPHX2 has the best heat transfer enhancement with an overall heat transfer coefficient of 632.1 W∙m-2∙K-1, which is more than twice of GMPHX1 and five times of CMPHX. Moreover, GMPHX2 can achieve more uniform refrigerant flows and PCM temperature distributions than GMPHX1. This leads to the higher utilization ratio of PCM latent heat. CMPHX is the second best but needs larger heat transfer surface area and inner volume as well as more refrigerant charge. In conclusion, the system design with GMPHX2 is recommended due to its small refrigerant charge, high VCC COP, and the use of good heat transfer enhancement material.

Qiao, Yiyuan↗