Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nano-engineered Multiwall Carbon Nanotube-copper Composite Thermal Interface Material for Efficient Heat Conduction

Efforts in integrated circuit (IC) packaging technologies have recently been focused on management of increasing heat density associated with high frequency and high density circuit designs. While current flip-chip package designs can accommodate relatively high amounts of heat density, new materials need to be developed to manage thermal effects of next-generation integrated circuits. Multiwall carbon nanotubes (MWNT) have been shown to significantly enhance thermal conduction in the axial direction and thus can be considered to be a candidate for future thermal interface materials by facilitating efficient thermal transport. This work focuses on fabrication and characterization of a robust MWNT-copper composite material as an element in IC package designs. We show that using vertically aligned MWNT arrays reduces interfacial thermal resistance by increasing conduction surface area, and furthermore, the embedded copper acts as a lateral heat spreader to efficiently disperse heat, a necessary function for packaging materials. In addition, we demonstrate reusability of the material, and the absence of residue on the contacting material, both novel features of the MWNT-copper composite that are not found in most state-of-the-art thermal interface materials. Electrochemical methods such as metal deposition and etch are discussed for the creation of the MWNT-Cu composite, detailing issues and observations with using such methods. We show that precise engineering of the composite surface affects the ability of this material to act as an efficient thermal interface material. A thermal contact resistance measurement has been designed to obtain a value of thermal contact resistance for a variety of different thermal contact materials.

Ngo, Quoc↗

The Capella subcoronal heating efficiency

Using transition region fluxes and high resolution spectra of the Ly-alpha and Mg II h and k lines observed by the GHRS spectrograph, I determine the total flux radiated from each temperature regime in the Capella upper chromosphere and transition region. This contains essentially the same information as the emission measure distribution, but to better suggest physical interpretations of the heating mechanisms it is expressed instead in terms of the efficiency for extracting convection zone energy flux and depositing it over the temperature ranges considered.

Gayley, Kenneth G.↗

Electrochemically driven phase transformation for high-efficiency heat pumping

To reduce energy consumption and improve energy utilization in space conditioning, advanced heat pumping technologies are needed. The chemical looping heat pump (CLHP) is a promising thermodynamic cycle that has theoretically shown the potential to achieve a cooling coefficient of performance (COP c ) increase of over 20% relative to conventional vapor compression systems. In this paper, the key process of the CLHP is experimentally demonstrated, and the system performance and non-ideal behavior are predicted using the component-level models. The results show the feasibility of electrochemical phase change of a working fluid; the peak COP c was 7.64 with a cooling capacity of 3.6 mW (cooling density of 2.57 W m -2 ) at both sink and source temperature of 23°C based on laboratory experiments. The COP c can theoretically reach up to 13 at a temperature lift of 15°C as long as an electrochemical cell can achieve a greater degree of conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Increase resistance for efficient heating

Conductors for use in heating systems are provided. The conductors are configured to have an extended current path for the current and increased resistance as seen by the current. The heating system may be an induction system. For example, the conductor may comprise a conductive material having a surface which faces an induction coil of an oscillating circuit. This surface may have a predetermined pattern of peaks and valleys. The peaks and valleys form a non-linear current path for the induced current when exposed to an electromagnetic field generated by the oscillating circuit. Other conductors such as a heat pipe may be used. The pipe may have walls with varying thicknesses over its length. The varying thicknesses may include a first thickness and a second thickness which alternate. The heat pipe may be used in an induction or direct contact heating system where AC is directly applied to the pipe.

Kisner, Roger A.↗

Impact of Intake and Exhaust Ducts on the Recovery Efficiency of Heat Recovery Ventilation Systems

The heat recovery efficiency of ventilation systems utilizing heat recovery ventilators (HRVs) depends not only on the heat recovery efficiency of the HRV units themselves but also on the intake and exhaust ducts that connect the HRV units to the outside environment. However, these ducts are often neglected in heat loss calculations, as their impact on the overall heat recovery efficiency of HRV systems is often not understood and, to the knowledge of the authors, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for these ducts has not been published. In this research, a mathematical model for the overall heat recovery efficiency of HRV systems that accounts for the intake and exhaust ducts was derived and validated using real-life data. The model-predicted decrease in heat recovery efficiency due to the ducts was in reasonable agreement (relative error within 20%) with the real-life measurements. The results suggest that utilizing this model allows for more correct ventilation heat loss calculations compared to using the heat recovery efficiency of the HRV unit alone, but more field studies are needed to verify the accuracy of this model in a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ELECTRON TEMPERATURES IN THE UPPER ATMOSPHERE

Energy loss processes for fast electrons, electron heating efficiency, heat input to the electron gas, effect of thermal coupling, and electron thermal conductivity above the f2 peak

F- 2 LAYER↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗

Utah FORGE 8-3637: Integrated Diagnostics for Interpreting Doublet Heat Sweep Efficiency - 2024 Annual Workshop Presentation

This is a presentation on the Integrated Diagnostics for Interpreting Doublet Heat Sweep Efficiency by Texas Tech University, presented by Smith Leggett. This video slide presentation discusses the ID squared technical objectives to develop and integrate diagnostic tools to determine (1) the number of fractures, (2) the uniformity of flow distribution, (3) heat exchange areas, and (4) heat efficiency. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 15, 2024.

15 GEOTHERMAL ENERGY↗

The effect of building retrofit measures on CO2 emission reduction – A case study with U.S. Medium office buildings

Building retrofit has great potential to reduce CO2 emissions since buildings are responsible for 36% of emissions in the United States. Several existing studies have examined the effect of building retrofit measures on CO2 emission reduction. However, these studies oversimplified emission factors of electricity by adopting constant annual emission factors. This study uses hourly emission factors of electricity to analyze the effect of building retrofit measures on emission reduction using U.S. medium office buildings as an example. We analyzed CO2 emission reduction effects of eight building retrofit measures that related to envelop and mechanical system in five locations: Tampa, San Diego, Denver, Great Falls, and International Falls. The main findings are: (1) estimating CO2 emission reduction with constant emission factors overestimates the emission reduction for most measures in San Diego, while it underestimates the emission reduction for most measures in Denver and International Falls; (2) The same retrofit measure may have different effects in CO2 emission reduction depending on the climates. For instance, improving lighting efficiency and improving equipment efficiency have less impacts in emission reduction in cold climates than hot climates; and (3) The most energy efficient measure may not be the most emission efficient measure. For example, in Great Falls, the most energy efficient measure is improving equipment efficiency, but the most emission efficient measure is improving heating efficiency.

Lou, Yingli↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Catalyst Compositions for Microwave-Assisted Methane Dehydroaromatization

The flaring of natural gas in U.S. shale regions remains a challenge for producers. One alternative to flaring is converting the wasted gas into valuable chemicals. Microwave-based processes offer a promising solution, potentially enabling the development of compact, modular systems for on-site production of chemicals, such as aromatics, from natural gas. This is due to the advantages of microwave heating, including efficient heating of compact volumes, accelerated reaction rates, and electrification of heating. However, developing effective catalysts for microwave-based processes is challenging, as conventional materials often require modification to be effectively heated by microwaves. This study provides an overview of a catalyst development project focused on a molybdenum-supported zeolite catalyst, optimized for the direct conversion of methane into aromatics under microwave irradiation. It details the synthesis, characterization, and the effects of promoters, as well as computational efforts undertaken to understand and enhance the catalyst's performance.

flare gas↗

The Spread of Ocean Heat Uptake Efficiency Traced to Ocean Salinity

Abstract Ocean heat uptake (OHU) plays an important role in determining the rate of surface warming under CO 2 forcing. We examined the transient response to CO 2 forcing in a set of 30 climate models from Coupled Model Intercomparison Project Phase 6 (CMIP6) and found that the intermodel spread in OHU efficiency largely depends on the base‐state ocean stratification, especially in the Southern Ocean. This dependence is primarily traced to ocean salinity rather than ocean temperature. Models with weaker ocean stratification primarily due to higher upper‐ocean salinity tend to sequester heat into the deeper ocean, leading to a lower rate of surface warming, a primary reason for higher OHU efficiency; the stratification impact on total OHU is secondary. We applied the relationship between salinity and OHU efficiency for an emergent constraint on OHU efficiency, suggesting an OHU efficiency higher than the CMIP6 multimodel average and arguing against models with extremely low efficiency.

54 ENVIRONMENTAL SCIENCES↗