Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

FIREFLY: heat load and particle exhaust approximations for rapid evaluation of divertor designs

The divertor in a magnetic confinement fusion reactor is an essential component for power dissipation and particle removal. The FIREFLY package for rapid evaluation of divertor designs is presented as an extension of the FLARE code for field line reconstruction from a flux tube mesh. First, divertor loads are approximated with a simplified heat transport model. Neutralized particles are then sampled from the resulting load distribution, and the EIRENE code is used to track molecules and atoms in a plasma background while accounting for dissociation, charge exchange and ionization. Particles are removed on pumping surfaces in order to estimate the exhaust efficiency for a given divertor geometry. Optimization of the divertor geometry for more efficient particle exhaust is explored by using W7-X as an example, and the sensitivity to model parameters for the plasma background in the proxy calculations is evaluated.

mesh generation, magnetic field lines, scrape-off ↗

Divertor heat load estimates on NSTX and DIII-D using new and open-source 2D inversion analysis code

A thermography inversion algorithm has been developed in the open-source Python-based computer code, HYPERION, to calculate the heat flux incident on plasma-facing components (PFCs) in axisymmetric tokamaks. The chosen mesh size at the surface significantly affects the calculated transient heat flux results. The calculated transient heat flux will exceed the real value when the mesh size tends to zero but will underestimate the real value when the mesh size is large. A criterion for determining the appropriate mesh size for the transient heat flux calculation will be discussed. The numerical scheme for HYPERION uses a 2D fully implicit finite-difference approach, allowing temperature-dependent thermal properties of PFC materials. The inversion algorithm is benchmarked against established heat flux calculation codes, TACO and THEODOR, based on thermography data from NSTX and DIII-D respectively. The primary benefits of HYPERION compared to TACO and THEODOR are that it is open-source and it allows for the optimization of mesh thickness along the substrate. The algorithm also accounts for the thermal properties of thin surface layers that characteristically form on PFCs due to plasma-material interactions. The agreement between HYPERION and THEODOR is excellent, as the percent difference between the codes is ~5% on average in the case of the DIII-D data for moderate to high heat flux. Verification tests with TACO show slightly higher average percent differences of 8% and 12%. In using HYPERION to study filaments in heat flux, the initial results indicate that small ELMs filaments significantly broaden the divertor heat flux, and decrease divertor peak flux. Compared to the inter-ELM, the small ELM filaments decrease the divertor peak surface temperature. With intermittent divertor filaments, the divertor heat flux width is comparable with that found in L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary of the IAEA technical meeting on plasma disruptions and their mitigation

Here we summarize the contributions presented at the IAEA technical meeting on plasma disruptions and their mitigation, held virtually, 20–23 July 2020. The meeting brought together more than 120 experts from nuclear fusion research sites worldwide to discuss experimental, theoretical and modelling work in the field of plasma disruptions with special emphasis on developing a solid basis for possible disruption mitigation strategies in ITER and next generation fusion devices. The main topics of the meeting were: (i) disruption consequences, including electromagnetic loads, heat loads, and runaway electrons; (ii) disruption prediction and avoidance, including machine learning and physics-based approaches, and control aspects; and (iii) disruption mitigation, including shattered pellet injection, alternative techniques and general aspects of disruption mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Temperature-Time Modeling of Spent Fuel Cladding in Dry Storage Casks

This report uses thermal and decay heat modeling to investigate spent fuel performance and the potential for cladding to anneal in dry storage conditions. Annealing is an important feature to investigate in SNF cladding because it has a direct relationship to cladding response in storage, transportation and disposal conditions. Annealed cladding may have lower strength than unannealed cladding, however its increased ductility would provide better protection against rupture in high strain rate situations such as severe accidents. These consequences are the driver for this work however are outside of the scope of this report. The modeling focused on three representative storage systems, the TN-32B, MAGNASTOR with TSC-37 canister, and NUHOMS AHSM with a 32PTH2 canister. This covers the vertical dual-purpose, vertical ventilated and horizontal ventilated casks respectively. Decay heat modeling using high and low enrichment assemblies was used to bound the decay heat curves that might be expected in dry storage. To bound the temperature relationship, the storage casks were modeled starting at the design basis heat loads with heat decaying through time. Although the results are bounding there is not an attempt to maximize conservatism, rather the intent to form a reasonable upper limit on temperature that will be broadly applicable to the U.S. cask fleet. This will allow materials testing to focus on relevant conditions for annealing that may affect the U.S. spent fuel inventory. The results show a clear dependence on heat load pattern in time in Figure S-1 and Figure S-2. This dependence is due to the different assembly decay heat curves for different assemblies in preferentially loaded casks. It shows the need for careful decay heat modeling when examining in service fuel temperatures that are less than the cask design basis heat load. The body of the report shows percent cladding cutoffs of 300°C and 350 °C as well. These results can be used to inform testing and conclusions about cladding performance through time and the potential for cladding annealing during dry storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing plasma face component thermal response to rotating 3D magnetic fields for SPARC tokamak

Thermal response simulations of plasma-facing components (PFCs) in the SPARC tokamak, performed with the HEAT code, show that three-dimensional (3D) heat loads resulting from stationary n=1 perturbations require highly radiative scenarios, with up to 95% of the power crossing the separatrix (P SOL ) being radiated, to maintain PFC temperatures within acceptable operational limits, whereas the application of slowly rotating 3D fields substantially reduces the thermal loads. The HEAT module, developed to predict heat loads from non-axisymmetric plasmas, is extended to model time-dependent heat flux patterns generated by rotating 3D fields, and a comprehensive thermal analysis is performed on PFCs subjected to both the maximum and minimum power loads, as well as to rotating heat flux distributions, to evaluate the temperature evolution for varying perturbation amplitudes and rotation frequencies. The extension of this analysis to 3D fields with toroidal mode number n=2 shows that this configuration leads to weaker localized heat flux peaks relative to the n=1 case, enabling safe operation with less than 80% of the power radiated when static 3D fields of low amplitude are applied, while using slowly rotating fields at higher amplitudes. These results indicate that n=2 perturbations are generally less detrimental to divertor power exhaust, emphasizing the strong dependence of divertor power exhaust on the characteristics of the applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Models implemented in the methodological approach to design the initial STEP first wall contour

The official Spherical Tokamak for Energy Production mission aims to demonstrate the ability to generate net electricity from fusion with the STEP Prototype Power plant. One of the key technological and engineering challenges in fusion power plants is managing the loads on the first wall within acceptable limits. Therefore, the conceptual design development of the STEP Prototype Power plant needs to be based on load estimates derived using legitimate plasma physics assumptions through dynamic and flexible tools. The current design foresees the STEP main chamber first wall to withstand steady-state heat loads of up to ~1 MW/m 2 , excluding critical regions expected to receive higher heat loads such as the baffle regions approaching the divertors. These critical areas will require ad hoc assessments and will be designed with the presence of limiters. This article focuses on the models and methodology adopted for designing the 2-D poloidal contour of the STEP first wall, based on the anticipated charged particle and radiation heat loads during normal operation. Firstly, the models adopted for calculating the charged particle and radiation heat loads are introduced. The first model is validated through benchmarking against the particle tracing code SMARDDA, while the second model is verified by comparing it with data from the MAST-U experiment. Secondly, the model used to design the 2-D first wall contour according to the heat loads is explained. We acknowledge that this preliminary design stage assumes certain simplifications, notably an axisymmetric geometry, for computational efficiency and clarity in presentation. It is understood that subsequent design phases will address the complexities of real-world engineering, including non-axisymmetric effects, transient plasma scenarios, and the impact of disruptions on the first wall design. Finally, an automatic procedure based on these models is presented for defining the 2-D poloidal contour of the STEP first wall to minimize heat loads, taking into account the need to radiate most of the alpha-particle and auxiliary heating power. Here, by providing an overview of the models, methodology, and an automatic procedure, this paper contributes to the design process of the STEP first wall, addressing the engineering challenges associated with fusion power plant development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Divertor Heat Flux Control using Impurity Powder Dropper

Divertor plasma-facing components (PFCs) in a tokamak are typically designed to withstand average steady-state heat loads of about 5–10 MW/m 2 , a limit that applies to both solid and liquid lithium (LL) PFCs. Exceeding these design values can result in surface damage to tungsten PFCs or excessive lithium (Li) evaporation in liquid lithium divertor (LLD) PFCs. Since exceeding the divertor heat load limits has serious consequences, it is therefore prudent to develop a tool to reduce the divertor heat load and bring the heat load to within the design limit without affecting the plasma performance. Active low Z impurity injection such as Li has been suggested as a potential solution to mitigate excess heat flux as suggested previously, given that non-coronal radiation can be quite large ~ 20–30 MJ per mole of injected Li. Li is considered desirable for reducing the edge neutral recycling helping to improve plasma energy confinement. In this paper, we model the Impurity Power Dropper (IPD) to investigate its potential of divertor heat flux control. The IPD is typically located at the top of the tokamak device and uses a vertical drift tube of a few meters. In the 2 m drift tube case, the IPD powder is accelerated to ~ 6 m/sec before reaching the plasma with the upper divertor configuration, matching the condition for the in-board side pellet injection case. By modeling the IPD geometry we determined the IPD powder deposition profile, and thus the non-coronal radiation and ionization profiles in time as well. From the enhanced radiation power loss, it is therefore possible to reduce the divertor heat load using the divertor simulation code. In conclusion, the IPD divertor heat flux control can be tested in the facilities with IPD including ST-40, DIII-D, EAST, WEST and NSTX-U.

Active lithium injection↗