Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modular nuclear reactors including fuel elements and heat pipes extending through grid plates, and methods of forming the modular nuclear reactors

A modular nuclear reactor comprises a plurality of sections arranged in a pattern and a side reflector material surrounding the plurality of sections. Each section includes a tank comprising a front plate, a back plate, side plates, a top plate, and a bottom plate. A plurality of grid plates are located within the tank. Each grid plate comprises a plurality of apertures and is vertically separated from an adjacent grid plate. The tank further includes a plurality of fuel elements extending through each grid plate. A plurality of heat pipes extend through each grid plate, the top plate, and an upper reflector. Methods of forming the modular nuclear reactor are also disclosed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT↗

Posiva's Onkalo{sup R} FST (Full-Scale In Situ System Test) - 20051

The FST - Full-scale In Situ System Test - is a unique full-scale demonstration of disposal system in crystalline host rock. The FST was constructed in ONKALO{sup R} demonstration area at the disposal depth of 420 metres, in Posiva's actual final disposal facility at Olkiluoto, Finland. The demonstration has included design, manufacture, installation and comprehensive instrumentation for monitoring the evolution of the disposal system and its components. The demonstration tunnel and experimental deposition holes were excavated in 2010 in ONKALO to address that they can be excavated to meet the requirements set for them. Two experimental deposition holes, bored in the floor of the tunnel, host each a canister surrounded by bentonite clay buffer rings/segments in the holes. Inside the canisters are heating elements to simulate decay heat emitted by spent fuel. The tunnel part used for the test is about 50 m long and it was filled with bentonite clay backfill after the installation of the canisters and buffer components. The tunnel is closed with a steel-reinforced concrete plug. The test is equipped with 500 sensors to monitor early evolution of the system. To forecast the evolution of the system, a mathematical model has been created. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty quantification for Joule heating processes in fibrous pore-resolved media

Joule heating (JH) is an energy-efficient and sustainable technique for heating materials. Its application for industrial heating, particularly, has been gaining attention due to its potential for increasing the yield of various chemical products. The process involves the use of heating elements (materials that are highly conductive electrically and thermally) to heat up other materials or substances. These conductors, however, can exhbit varying degrees of uncertainty due to non-linearities in their temperature-dependent properties, which could result in variable material behavior. In this work, we carry out uncertainty quantification (UQ) at the pore scale to describe the uncertainty of such materials. In so doing, we applied the non-intrusive polynomial chaos expansion (PCE) technique to quantify the uncertainty within the system. The steady state Joule heating equation was solved numerically at the pore scale mimicking conditions within a heating chamber for propane dehydrogenation, and various electro-thermal profiles were obtained. We also examined the effect of the number of sampling points (20 – 100) and order of the PCE coefficients (2 – 5) on the accuracy of the temperature evaluations. The results were then benchmarked with the standard Monte Carlo (MC) method. The average temperature of the 4th-order global PCE showed good agreement with the MC results (which were positively skewed). Orders greater than 4 gave an underestimation of the temperatures while predictions for the peak temperature improved as the number of sampling points increased.

Fagbemi, Samuel [ORNL] (ORCID:0000000236995025)↗

Experimental and Computational Heat Transfer Study of sCO 2 Single-Jet Impingement

This study experimentally and computationally investigates the heat transfer capability of supercritical carbon dioxide (sCO 2 ) single jet impingement. The evaluated jet Reynolds number range is between 80,000 and 600,000, with a nondimensional jet-to-target surface spacing of 2.8. CO 2 -impinging jet stagnation conditions were maintained at approximately 200 bar and a temperature of ∼400 °C for most experiments. The goal is to understand how changes in the aforementioned parameters influence heat transfer between the working fluid and the heated surface. Additionally, due to the elevated Reynolds numbers and difference in thermodynamic properties between air and CO 2 , air-derived impingement correlations may not be appropriate for CO 2 impingement; these correlations will be evaluated against experimental sCO 2 impingement data. At the time of this study, no sCO 2 impingement data was available relevant to sCO 2 power cycles. The target surface is a 1.5-in. diameter copper block centered on the 3 mm jet orifice. A mica heating element bolted to the bottom of the copper block provides a uniform heat flux. Thermocouples embedded in the copper block are used to determine the surface temperature. Nusselt numbers obtained from experimental sCO 2 test data are compared to area-averaged Nusselt numbers from air-derived correlations. The comparisons showed that air correlations drastically underpredict the heat transfer when sCO 2 is used as the working fluid. A modified sCO 2 correlation using experimental data at discussed conditions is derived based on an existing air correlation. A CFD study is also performed to further investigate sCO 2 heat transfer characteristics, and assess the numerical model applicability to this problem type.

42 ENGINEERING↗

THERMAL ANALYSIS AND DESIGN OF SELF-HEATING MOLDS USING LARGE-SCALE ADDITIVE MANUFACTURING FOR OUT-OF-AUTOCLAVE APPLICATIONS

Autoclave processing is a commonly used state-of-the-art fiber-reinforced composite manufacturing technology, albeit high capital cost, long cycle times and high energy consumption. Alternatively, out-of-autoclave processing reduces the initial and operating costs while producing composite structures with similar quality as that of autoclave parts. Additive Manufacturing (AM) the scaled-up molds for out-of-autoclave process using carbon fiber (CF) reinforced composite offers design flexibility, enhanced mechanical, and thermal properties in addition to reduction in weight and cost. However, heating of these molds using an oven is still expensive and necessitates an energy-efficient heating process. In this study, resistive heating through heating elements embedded within fiber reinforced composite molds is used as an efficient heating mechanism. The goal is to design wire embeddings and determine the optimal heat flux density to achieve a target uniform temperature of 1000C across the mold surface. To this end, numerical analyses were performed to evaluate the temperature distribution across the composite mold surface for a given wire placement and mold configuration. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) were used in the thermal analysis. Time taken to reach the steady state temperature was also estimated. Design guidelines for wire embeddings were included to enable efficient manufacturing of fiber-reinforced composites through out-of-autoclave molds.

Pokkalla, Deepak↗

Experimental and Computational Heat Transfer Study of sCO2 Single Jet Impingement

The present study experimentally investigates the heat transfer capability of supercritical carbon dioxide (sCO2) single-jet impingement. The evaluated jet Reynolds number range is between 80,000 and 1,000,000, with a non-dimensional jet-to-target surface spacing of 2.8. CO2- impinging jet stagnation conditions were maintained at approximately 20 MPa and a temperature of 673 K for most experiments. The goal is to understand how changes in the aforementioned parameters influence heat transfer between the working fluid and the heated surface. Additionally, due to the elevated Reynolds numbers and difference in thermodynamic properties between air and CO2, air-derived impingement correlations may not be appropriate for CO2 impingement; these correlations will be evaluated against experimental sCO2 impingement data. At the time of this study, no sCO2 impingement data was available relevant to sCO2 power cycles. The target surface is a 1.5-inch diameter copper block centered on the 3mm jet orifice. A mica heating element bolted to the bottom of the copper block provides a uniform heat flux. Thermocouples embedded in the copper block are used to determine the surface temperature. Nusselt numbers obtained from experimental sCO2 data are compared to area-averaged Nusselt numbers from air-derived correlations. The comparisons showed that air correlations drastically underpredict the heat transfer when sCO2 is used as the working fluid. A modified sCO2 correlation using experimental data at discussed conditions is derived based on an existing air correlation.

Richardson, John↗

Large-scale additive manufacturing of self-heating molds

Large-scale material extrusion additive manufacturing technology is becoming the new mainstream technology for scaled-up composite mold and die applications. This paradigm shift in composite processing technology is primarily driven by out-of-autoclave tooling applications, in which fiber reinforced composite molds with scaled-up sizes and embedded heating elements are attractive. The present research describes the design, manufacturing, and testing of self-heating composite molds fabricated via a large-scale pellet extrusion 3D printing machine with an integrated wire co-extrusion tool. Polycarbonate (PC) composites reinforced with carbon fiber (PC/CF; 20 wt.%) and glass fiber (PC/GF; 20 wt.%) were used to fabricate mold parts. Joule heating thermal test results showed that uniform temperatures (~100 °C) were achieved for both PC/CF and PC/GF mold surfaces, using a custom-made feedback control power supply and infrared thermography. Mechanical characterizations, including tensile and flexural testing were performed on the wire-embedded and un-wired PC/CF and PC/GF base specimens to investigate the impact of the fiber reinforcement as well as the embedded wires. In the direction of extrusion, the ultimate tensile stress of PC/CF was 105 MPa, and that of PC/GF was 73 MPa, while the neat PC value was 64 MPa. Inner-bead voids and interfacial gaps were observed and characterized via optical and scanning electron microscopy. The embedded wires and inner bead impacted the mechanical properties of the composites. Furthermore, the stiffness of the wire-embedded mold was still satisfactory, proving that the technology can be used to fabricate additively manufactured out-of-oven/autoclave molds.

36 MATERIALS SCIENCE↗

Quantitative Fit Evaluation of N95 Filtering Facepiece Respirators and Coronavirus Inactivation Following Heat Treatment

Abstract Reuse of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use has become common in healthcare facilities due to shortages caused by the COVID-19 pandemic. Here, we report that murine hepatitis coronavirus initially seeded on FFR filter material is inactivated (6 order of magnitude reduction as measured by median tissue culture infective dose, TCID50) after dry heating at 75°C for 30 min. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or 10 heating cycles. Previous studies have reported that the filtration efficiency of FFRs is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to reuse N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also observe that a radiative heat source (e.g. an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investigating heat as a means to recycle FFRs. These differences suggest that while our repeated decontamination cycles do not affect FFR fit, overall wear time and the number of donning/doffing cycles are important factors that likely degrade FFR fit and must be investigated further.

60 APPLIED LIFE SCIENCES↗

Quantitative form and fit of N95 filtering facepiece respirators are retained after dry and humid heat treatments for coronavirus deactivation

Re-use of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use only is becoming common in healthcare facilities due to shortages caused by the COVID19 pandemic. Here we report that mouse hepatitis virus (MHV) initially seeded on FFR filter material is inactivated (6 log reduction as measured by 50% tissue culture infective dose (TCID50)) after dry heating at 75 °C for 30 minutes. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or ten heating cycles. Previous studies have reported that the filtration efficiency of FFR filters is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to re-use N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also found that a heat source that emits radiation (e.g., an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investing heat as a means to recycle FFRs and suggest that overall wear time and donning/doffing cycles are important factors that need to be considered.

36 MATERIALS SCIENCE↗

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation studies of the interaction of laser radiation with additively manufactured foams

The interaction of laser radiation with foams of various porosities and low densities has been the subject of several numerical and experimental studies. In all cases, the modeling of low-Z under-dense foams as uniform gases of equivalent average density using standard radiation-hydrodynamics codes has resulted in heat-front velocities that are considerably faster than those observed experimentally. It has been theoretically conjectured that this difference may be attributed to the breakdown of the foam’s morphology, leading to a dynamics of filament expansion where the ion and electron energy partitions are significantly different from those calculated using the uniform gas model. We found that 3D computer simulations employing a disconnected representation of the foam’s microstructure which allowed for the dynamics of foam element heating, expansion, and stagnation largely supported the theoretical picture. Simulations using this model for laser experiments on under-dense 2 mg cc -1 SiO 2 aerogel foams reproduced the experimental data fairly well. We used the validated model in simulations of low-density structured foam-like materials (produced via additive manufacturing) with a variety of morphologies. We found that the log-pile configurations were consistent with the analytical propagation model of Gus’kov et al. Further validation of the model was obtained by simulating experiments performed at the Jupiter Laser Facility using the log-pile and octet-truss foam morphologies. Simulations of the foam-laser interaction using a wave propagation code showed that the microstructure was able to enhance stimulated Brillouin scattering (SBS) by concentrating the light energy into density holes. In turn, this promotes laser filamentation, reducing SBS and bringing the predicted values closer to the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser heating of ferroelectric cubes for tunable electromagnetic properties in metamaterials

In this experimental study, we demonstrate the feasibility of a thermally tunable, resonant dielectric microwave metasurface based on sub-wavelength Mie resonances of ferroelectric dielectric cubes (Calcium titanate, CaTiO 3 ) in which the temperature of the meta-atoms can be locally and dynamically controlled by heating with an optical laser beam over a large range of temperatures and, consequently, values of the dielectric constant of the cube and corresponding resonance frequency of the meta-atoms. Further, this avoids any interference of otherwise necessary heating elements or power supply wires with the propagation of the microwave signal and can be made spatially addressable. The concept scales at least to the THz domain. This contactless approach opens up an alternative avenue to tunability and active control of metamaterials.

36 MATERIALS SCIENCE↗