Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hemp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cradle-to-gate life cycle assessment of advanced composite panels incorporating CO 2 -derived multi-walled carbon nanotubes and hemp fiber for sustainable building applications

Advanced composite panels represent a promising pathway to reducing carbon emissions in the construction industry, yet comprehensive environmental impact assessments remain limited. Here, in this study, we conduct a life cycle assessment (LCA) to evaluate the environmental impacts of innovative composite panels produced from multi-walled carbon nanotubes (MWCNTs), hemp fiber (HF), recycled carbon fiber (rCF), and recycled polypropylene (PP), exploring their potential as baseline structural equivalents to conventional gypsum board. MWCNTs and HF play a critical role in sequestering carbon during raw material production, while the recycling processes for CF and PP generally require less energy compared to virgin material production. The LCA evaluates environmental performance using the TRACI 2.1 method, covering global warming potential (GWP), ozone depletion, smog formation, acidification, eutrophication, carcinogenic and non-carcinogenic effects, respiratory impacts, ecotoxicity, and fossil fuel depletion. Compositional variations—resin type (virgin vs. recycled), rCF content (9–29 wt%), and HF content (10–30 wt%)—are introduced for sensitivity and hotspot analyses. Results demonstrate that, when compared on the basis of preliminary structural equivalence, increasing recycled PP, rCF, and HF content can significantly reduce global warming potential compared to gypsum board. Beyond carbon reduction, the composite panels show trade-offs across other environmental categories. With the growing demand for composite materials in interior panels, ceiling systems, and exterior claddings, these findings highlight the environmental benefits and potential trade-offs of the proposed composites, establishing a foundational framework to support their continued development toward full building-system integration.

Advanced composite manufacturing↗

Phylogenomic analysis of the hemp family (Cannabaceae) reveals deep cyto‐nuclear discordance and provides new insights into generic relationships

Abstract Cannabaceae are a relatively small family of angiosperms, but they include several species of huge economic and cultural significance: marijuana or hemp ( Cannabis sativa ) and hops ( Humulus lupulus ). Previous phylogenetic studies have clarified the most deep relationships in Cannabaceae, but relationships remain ambiguous among several major lineages. Here, we sampled 82 species representing all genera of Cannabaceae and utilized a new dataset of 90 nuclear genes and 82 chloroplast loci from Hyb‐Seq to investigate the phylogenomics of Cannabaceae. Nuclear phylogenetic analyses revealed a robust and consistent backbone for Cannabaceae. We observed nuclear gene‐tree conflict at several deep nodes in inferred species trees, also cyto‐nuclear discordance concerning the relationship between Gironniera and Lozanella and the relationships among Trema s.l. (including Parasponia ), Cannabis + Humulus , and Chaetachme + Pteroceltis . Coalescent simulations and network analyses suggest that observed deep cyto‐nuclear discordances were most likely to stem from incomplete lineage sorting (ILS); nuclear gene‐tree conflict might be caused by both ILS and gene flow between species. All genera of Cannabaceae were recovered as monophyletic, except for Celtis , which consisted of two distinct clades: Celtis I (including most Celtis species) and Celtis II (including Celtis gomphophylla and Celtis schippii ). We suggest that Celtis II should be recognized as the independent genus Sparrea based on both molecular and morphological evidence. Our work provides the most comprehensive and reliable phylogeny to date for Cannabaceae, enabling further exploration of evolutionary patterns across this family and highlighting the necessity of comparing nuclear with chloroplast data to examine the evolutionary history of plant groups.

Plant Sciences↗

Method for Coupled Electromagnetic and Circuit Simulations to Evaluate Surge Arrester Performance in Protecting Equipment Against E1 HEMP

Surge arrester behavioral modeling for realistic systems embedded in an E1 high-altitude electromagnetic pulse environment inherently encompasses three interconnected complications: (1) the need to account for signal propagation across two domains, electromagnetics and electrical; (2) the need to include both linear and nonlinear circuit components in the analysis; and (3) the need to understand that the over-current and over-voltage mitigation performance is dependent not only on the properties of the surge arrester and protected load but also on the topology of the overall electrical network. This study presents a framework to address these challenges in a systematic manner to consider the effectiveness of protective measures for a common class of equipment in power generation facilities. Full-wave simulations were carried out to derive circuit-domain (i.e., lumped element–based) equivalent models for the excitation waveform and the physical components of the system. Then, these equivalent models were imported to a circuit solver and combined with a high-frequency surge arrester model to evaluate mitigation performance. The methodology outlined is general enough such that it can be applied for other electromagnetic interference problems that involve E2/E3 HEMP or microwave emissions.

42 ENGINEERING↗

Comparative Life Cycle Assessment of Bacterial and Thermochemical Retting of Hemp

The processes of hemp bast fiber retting, forming, and drying offer the opportunity for value-added products such as natural fiber-reinforced composites. A new process for the retting of raw bast fibers through enzyme-triggered self-cultured bacterial retting was developed in the lab-scale setup. This study focused on comparing the energy consumption and environmental impacts of this bacterial retting process with the thermochemical retting process currently widely used to obtain lignocellulosic fibers for composites. The gate-to-gate life cycle assessment (LCA) models of the two retting processes were constructed to run a comparison analysis using the TRACI (the tool for the reduction and assessment of chemical and other environmental impacts) method for environmental impacts and the cumulative energy demand (CED) method for energy consumptions. This work has demonstrated the advantages of the bacterial retting method from an environmental standpoint. The result of our research shows about a 24% gate-to-gate reduction in CED for bacterial retting and 20–25% lower environmental impacts relating to global warming, smog formation, acidification, carcinogenics, non-carcinogenics, respiratory effects, ecotoxicity, and fossil fuel depletion when compared to that of thermochemical retting.

Chemistry↗

Bacterial-Retted Hemp Fiber/PLA Composites

The push for sustainability in all facets of manufacturing has led to an increased interest in biomass as an alternative to non-renewable materials. Hemp bast fiber mats were produced from a bacterial retting process, named BFM, as the fiber reinforcement. The objective of this study was to evaluate the feasibility of laminating BFM with polylactic acid (PLA) for a composite panel product. Since both BFM and PLA are biodegradable, the resulting BFM-PLA composites will be 100% biodegradable. PLA pallets were processed into thin polymer sheets which served as the matrix. The BFM and PLA plates were laminated in five layers and compression-molded into composite panels. Experiments were conducted on the three BFM-to-PLA ratios (35/65, 45/55, and 50/50). Mechanical properties (tensile and bending properties) and physical properties (thickness swell and water absorption) were tested and compared to the currently commercial sheet molding compound (SMC) from fiber glass. The thermal behavior of the BFM/PLA composites was characterized using dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). The developed BFM/PLA composite product is a sustainable alternative to existing synthetical fiber-reinforced polymer (FRP) that is biodegradable in landfill at the end of life.

Smith, Lee M. (ORCID:0000000264390357)↗

Effects on Structure’s Electromagnetic Shielding Effectiveness Considering Penetrating Cables Coupling Energy from HEMP Event

The threat of weaponized electromagnetic pulse (EMP) is a serious factor in defining power system resilience. Without adequate knowledge regarding the interaction between EMP and power system infrastructure, system personnel may be unable to plan for and operate during an EMP event and major blackouts could occur. This work studies the interaction between EMP and structures, specifically analyzing the shielding effectiveness of buildings emulating power generation facilities. The main focus is to determine how penetrating cables affect the structure’s shielding effectiveness. Several cable parameters including height above ground, radius, termination configuration, and length are analyzed via computational electromagnetic simulations. Results demonstrated penetrating cables can significantly diminish a structure’s shielding effectiveness, especially the electric field. Length of cable is the most influential parameter.

Mignardot, David↗

HEMP Transformer Defense Through Power Electronics

High altitude electromagnetic pulses and geo-magnetic disturbances have the potential to severely impact the electric power grid by damaging large power transformers and causing severe power quality issues. This impact comes as a result of a quasi-static bias induced on transmission lines by geomagnetically induced currents which saturate magnetic components in the electric power system. This paper introduces the concept of utilizing a h-bridge inverter on the neutral of a LPT to inject a DC bias equivalent voltage onto the neutral side of the transformer windings. This biasing floats the transformer windings, eliminating the effect of the DC current and keeping the transformer from saturating. Schematic diagrams will be presented, along with simulation model data using Typhoon and PLECS, and finally test results from a benchtop hardware test.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Trip Coils

A High-Altitude Electromagnetic Pulse (HEMP) is a potential threat to the power grid. HEMP can couple to transmission lines and cables, causing significant overvoltages which can be harmful to line connected equipment. The effects of overvoltages on various types of power systems components need to be understood. HEMP effects on trip coils were tested and presented in this report. A high voltage pulser was built to replicate the induced voltage waveform from a HEMP. The pulser was used to test breaker trip coils with increasing pulse magnitudes ranging from 20 kV to 80 kV. The State-of-Health of each trip coils was measured via mechanical operation and impedance measurements before and after each insult to identify any damage or degradation to the trip coils. Dielectric breakdown was observed at the conductor leads during testing, causing the HEMP insult to be diverted to the grounded casing. However, the dielectric breakdown did not cause interference with regular device operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Transient Voltage Surge Suppressors

Determining the effectiveness of surge and pulse protection devices in the United States power grid against effects of a High-Altitude Electromagnetic Pulse (HEMP) is crucial in determining the present state of grid resilience. Transient Voltage Surge Suppressors (TVSS) are used to protect loads in substations from transient overvoltages. Designed to mitigate the effects of lightning, their response to a HEMP event is unknown and was determined. TVSSs were tested in two unique configurations using a pulser that generates pulses in the tens of nanoseconds scale to determine their protective capability as well as to determine their self-resilience against HEMP pulses. Testing concluded that TVSS devices adequately protect against microsecond scale pulses like lightning but do not protect against pulses resembling HEMP events. It suggests that TVSS devices should not be relied upon to mitigate the effects of HEMP pulses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMP Testing of UL489 Circuit Breakers

Sandia National Laboratories (SNL) is performing a test campaign for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) to address high-altitude electromagnetic pulse (HEMP) vulnerability of critical components of generation stations, with focus on early-time (E1) HEMP. The campaign seeks to establish response and damage thresholds for these critical elements in response to reasonable HEMP threat levels as a means for determining where vulnerabilities may exist or where mitigations may be needed. This report provides component vulnerability test results that will help to inform site vulnerability assessments and HEMP mitigation planning.

42 ENGINEERING↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Elucidating the impact of fiber source on polypropylene/hemp composite performance for the automotive industry

Given their high strength-to-weight ratio, there is an ever-increasing volume of plastics being used in the automotive industry as plastics aid in the charge to lightweight vehicles for improved fuel efficiency. However, these plastics are often landfilled at their end-of-life, which has given rise to the demand for sustainable materials and waste management alternatives compared to purely synthetic systems. Natural fiber composites have been explored as a viable material option to reduce the environmental impact of plastic use in automobiles while simultaneously ensuring the part performance is not sacrificed. Herein, we explored the use of hemp/polypropylene (PP) composites in which US-sourced hemp is compared to internationally sourced and industrially available hemp. There appears to be a minimal impact on the composite properties regardless of fiber sourcing, and the addition of a natural filler to the PP matrix results in up to a 367% increase in Young's modulus, 126% increase in heat deflection temperature, and comparable water uptake performance. It should be noted that the natural filler addition does increase density by up to 13% due to the higher density of natural fibers compared to the low-density PP matrix. A modified rule of mixtures calculation revealed that the composite materials produced in this study demonstrated good agreement with analytical modeling. Finally, a screening analysis was performed exploring the transportation of hemp fibers, and the results build a strong case for regionalized manufacturing of automotive parts.

Hubbard, Amber M. [Oak Ridge National Laboratory (↗

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗