Commercial High Resolution Optical Packages for Single Macromolecule Analysis and Control
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Fluorescence imaging of biological systems with spatial resolution beyond diffraction limit is of intensive interests. Recently, it has been discovered that by stochastically photoswitching fluorophores on and off, the diffraction limit can be circumvented in far-field optical imaging. Here we present a small photoswitching dye, spiropyran derivatives with the desired characteristics as the excellent photoswitchable molecular fluorophores.[3] Using such a fluorophore, we have achieved photoactuated unimolecular logical switching attained reconstruction (PULSAR) microscopy, with resolution down to 10-40 nm, far beyond the diffraction limit. Spiropyran requires no special treatment to cells and can be readily modified using chemical functional groups for specific targeting.
High-spatial resolution mass spectrometry imaging (MSI) is crucial for the mapping of chemical distributions at the cellular and subcellular level. In this work, we improved our previous laser optical system for matrix-assisted laser desorption ionization (MALDI)-MSI, from ~9 μm practical laser spot size to a practical laser spot size of ~4 μm, thereby allowing for 5 μm resolution imaging without oversampling. This is accomplished through a combination of spatial filtering, beam expansion, and reduction of the final focal length. Most importantly, the new laser optics system allows for simple modification of the spot size solely through the interchanging of the beam expander component. Using 10×, 5×, and no beam expander, we could routinely change between ~4, ~7, and ~45 μm laser spot size, in less than 5 min. We applied this multi-resolution MALDI-MSI system to a single maize root tissue section with three different spatial resolutions of 5, 10, and 50 μm and compared the differences in imaging quality and signal sensitivity. We also demonstrated the difference in depth of focus between the optical systems with 10× and 5× beam expanders. .
Purpose: Optical transmission and emission computed tomography (optical-CT/ECT) provides high-resolution 3D attenuation and emission maps in unsectioned large (∼1cm{sup 3}) ex vivo tissue samples at a resolution of 12.9µm{sup 3} per voxel. Here we apply optical-CT/ECT to investigate high-resolution structure and auto-fluorescence in a range of optically cleared mice organs, including, for the first time, mouse bone (femur), opening the potential for study of bone metastasis and bone-mediated immune response. Methods: Three BALBc mice containing 4T1 flank tumors were sacrificed to obtain spleen, brain, tumor, and femur. Tissues were washed in 4% PFA, fixed in EtOH solution (for 5, 10, 10, and 2 days respectively), and then optically cleared for 3 days in BABBs. The femur was also placed in 0.25M aqueous EDTA for 15–30 days to remove calcium. Optical-CT/ECT attenuation and emission maps at 633nm (the latter using 530nm excitation light) were obtained for all samples. Bi-telecentric optical-CT was compared side-by-side with conventional optical projection tomography (OPT) imaging to evaluate imaging capability of these two rival techniques. Results: Auto-fluorescence mapping of femurs reveals vasculatures and fluorescence heterogeneity. High signals (A.U.=10) are reported in the medullary cavity but not in the cortical bone (A.U.=1). The brain strongly and uniform auto-fluoresces (A.U.=5). Thick, optically dense organs such as the spleen and the tumor (0.12, 0.46OD/mm) are reconstructed at depth without significant loss of resolution, which we attribute to the bi-telecentric optics of optical-CT. The attenuation map of tumor reveals vasculature, attenuation heterogeneity, and possibly necrotic tissue. Conclusion: We demonstrate the feasibility of optical-CT/ECT imaging of un-sectioned mice bones (femurs) and spleen with high resolution. This result, and the characterization of unstained organs, are important steps enabling future studies involving optical-CT/ECT applied to study metastasis and immunologic responses via fluorescence staining.
We will present our experiences with the new High Energy Resolution Optics (HERO) upgrade on a Physical Electronics Auger 690 system. This upgrade allows the single pass cylindrical analyzer in the Auger system to achieve higher energy resolution than in the standard mode. With this upgrade, it should be possible to separate chemical states for certain elements. Also, it should be possible to separate closely spaced peaks from selected elements that have been difficult or impossible to separate without the upgrade. Specifically, we will investigate practical use of this upgrade in the analysis of materials systems where overlapping peaks have historically been an issue, such as Kovar, which consists of the elements Ni, Fe and Co. Strategies for the successful use of the technique as well as its current limitations will be shown.
High resolution optically pumped NMR (OPNMR) experiments are used to resolve fine features in the spin-dependent electronic structure of the valence bands in semi-insulating GaAs. By theoretically calculating oscillations in the OPNMR signal intensity with respect to the excitation energy, we have mapped out the conduction band electronic spin polarization under optical pumping. Comparison with a theoretical analysis of the oscillatory experimental features allows the extraction of semiconductor energy band parameters.
A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.
Purpose: With an increasing use of small field size and high dose rate irradiation in the advances of radiotherapy techniques, such as stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS), an in-depth quality assurance (QA) system is required. The purpose of this study is to investigate a high resolution optical CT-based 3D radiochromic dosimetry system for SBRT with intensity modulated radiotherapy (IMRT) and flattening filter free (FFF) volumetric modulated arc therapy (VMAT). Methods: Cylindrical PRESAGE radiochromic dosimeters of 10cm height and 11cm diameter were used to validate SBRT. Four external landmarks were placed on the surface of each dosimeter to define the isocenter of target. SBRT plans were delivered using a Varian TrueBeam™ linear accelerator (LINAC). Three validation plans, SBRT with IMRT (6MV 600MU/min), FFF-VMAT (10MV 2400MU/min), and mixed FFF-VMAT (6MV 1400MU/min, 10MV 2400MU/min), were delivered to the PRESAGE dosimeters. Each irradiated PRESAGE dosimeter was scanned using a single laser beam optical CT scanner and reconstructed with a 1mm × 1mm high spatial resolution. The comparison of measured dose distributions of irradiated PRESAGE dosimeters to those calculated by Pinnacle{sup 3} treatment planning system (TPS) were performed with a 10% dose threshold, 3% dose difference (DD), and 3mm distance-to-agreement (DTA) Gamma criteria. Results: The average pass rates for the gamma comparisons between PRESAGE and Pinnacle{sup 3} in the transverse, sagittal, coronal planes were 94.6%, 95.9%, and 96.4% for SBRT with IMRT, FFF-VMAT, and mixed FFF-VMAT plans, respectively. A good agreement of the isodose distributions of those comparisons were shown at the isodose lines 50%, 70%, 80%, 90% and 98%. Conclusion: This study demonstrates the feasibility of the high resolution optical CT-based 3D radiochromic dosimetry system for validation of SBRT with IMRT and FFF-VMAT. This dosimetry system offers higher precision QA with 3D dose information for small beams compared to what is currently available.
Owing to the depth to which hard X-rays penetrate into most materials, it is commonly accepted that the only way to realize hard-X-ray mirrors with near 100% reflectance is under conditions of total external reflection at grazing incidence to a surface. At angles away from grazing incidence, substantial reflectance of hard X-rays occurs only as a result of constructive interference of the waves scattered from periodically ordered atomic planes in crystals (Bragg diffraction). Theory predicts that even at normal incidence the reflection of X-rays from diamond under the Bragg condition should approach 100% - substantially higher than from any other crystal. Here we demonstrate that commercially produced synthetic diamond crystals do indeed show an unprecedented reflecting power at normal incidence and millielectronvolt-narrow reflection bandwidths for hard X-rays. Bragg diffraction measurements of reflectivity and the energy bandwidth show remarkable agreement with theory. Such properties are valuable to the development of hard-X-ray optics, and could greatly assist the realization of fully coherent X-ray sources, such as X-ray free-electron laser oscillators.
Doping induced solubility control (DISC) patterning is a recently developed technique which uses the change in polymer solubility upon doping, along with an optical dedoping process, to achieve high resolution optical patterning. DISC patterning is remarkable because the process resolution exceeds the linear Abbe’s diffraction limit, however, no mechanism has been proposed to explain such high resolution. Here, we use diffraction to spatially modulate the light intensity and determine the dissolution rate, revealing a superlinear dependence on light intensity, which yields features that are sharper than the profile of the writing photomask. This rate law is independent of wavelength, indicating that patterning resolution is not dominated by an optical dedoping reaction, as was previously proposed. Instead we show here that the optical patterning mechanism is primarily controlled by the thermal profile generated by the laser. To quantify this effect, the thermal profile and dissolution rate are modeled using a finite-element model and compared against patterned line cross sections as a function of wavelength, laser intensity, and dwell time. Our model reveals that although the laser-generated thermal profile is broadened considerably beyond the lasers resolution, the highly temperature dependent dissolution rate results in selective dissolution near the peak of the thermal profile. Therefore, the key factor in achieving super-resolution patterning is a strongly temperature dependent dissolution rate|a common feature of many polymers. In addition to suggesting several routes to improved resolution, our model also demonstrates that doping is not required for optical patterning of conjugated polymers, as was previously believed. Instead, we demonstrate that superlinear resolution optical patterning is attainable in any conjugated polymer simply by tuning the solvent quality during patterning, thus extending the applicability of our method to a wide class of materials. Here, we demonstrate the generality of photothermal patterning by writing sub-400 nm features into undoped Pff-BT4T-2OD.
A generic new data processing method is developed
Precise patterning of quantum dot (QD) layers is an important prerequisite for fabricating QD light-emitting diode (QLED) displays and other optoelectronic devices. However, conventional patterning methods cannot simultaneously meet the stringent requirements of resolution, throughput, and uniformity of the pattern profile while maintaining a high photoluminescence quantum yield (PLQY) of the patterned QD layers. Here, a specially designed nanocrystal ink is introduced, "photopatternable emissive nanocrystals" (PENs), which satisfies these requirements. Photoacid generators in the PEN inks allow photoresist-free, high-resolution optical patterning of QDs through photochemical reactions and in situ ligand exchange in QD films. Various fluorescence and electroluminescence patterns with a feature size down to approximate to 1.5 mu m are demonstrated using red, green, and blue PEN inks. The patterned QD films maintain approximate to 75% of original PLQY and the electroluminescence characteristics of the patterned QLEDs are comparable to thopse of non-patterned control devices. The patterning mechanism is elucidated by in-depth investigation of the photochemical transformations of the photoacid generators and changes in the optical properties of the QDs at each patterning step. This advanced patterning method provides a new way for additive manufacturing of integrated optoelectronic devices using colloidal QDs.
Explore the source record for details and available documents.
We show that magnetometry measurements based upon the magneto-optical Kerr effect and high resolution optical microscopy can be used as a noninvasive probe of magnetization reversal for individual nano-structures. Our measurements demonstrate single pass hysteresis loop measurements for sample sizes down to 30 nm width. A quantitative signal-to-noise ratio evaluation shows that our approach achieves an at least 3-fold improvement in sensitivity if compared to focused laser based nano-magnetometry. An analysis of the physical limits of our detection scheme enables us to estimate that measurements for structures with single digit nm widths and magnetic moments of 10{sup -16} Am{sup 2} are feasible.
We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9–9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8–10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.