High Voltage EEE Parts for EMA/EHA Applications on Manned Launch Vehicles

The objective of this paper is an assessment of high voltage electronic components required for high horsepower electric thrust vector control (TVC) systems for human spaceflight launch critical application. The scope consists of creating of a database of available Grade 1 electrical, electronic and electromechanical (EEE) parts suited to this application, a qualification path for potential non-Grade 1 EEE parts that could be used in these designs, and pathfinder testing to validate aspects of the proposed qualification plan. Advances in the state of the art in high power electric power systems enable high horsepower electric actuators, such as the electromechnical actuator (EMA) and the electro-hydrostatic actuator (EHA), to be used in launch vehicle TVC systems, dramaticly reducing weight, complexity and operating costs. Designs typically use high voltage insulated gate bipolar transistors (HV-IGBT). However, no Grade 1 HV-IGBT exists and it is unlikely that market factors alone will produce such high quality parts. Furthermore, the perception of risk, the lack of qualification methodoloy, the absence of manned space flight heritage and other barriers impede the adoption of commercial grade parts onto the critical path. The method of approach is to identify high voltage electronic component types and key parameters for parts currently used in high horsepower EMA/EHA applications, to search for higher quality substitutes and custom manufacturers, to create a database for these parts, and then to explore ways to qualify these parts for use in human spaceflight launch critical application, including grossly derating and possibly treating hybrid parts as modules. This effort is ongoing, but results thus far include identification of over 60 HV-IGBT from four manufacturers, including some with a high reliability process flow. Voltage ranges for HV-IGBT have been identified, as has screening tests used to characterize HV-IGBT. BSI BS ISO 21350 Space systems Off-the-shelf item utilization, developed from Marshall Work Instruction MWI8060.1 OFF-THE-SHELF HARDWARE UTILIZATION IN FLIGHT HARDWARE DEVELOPMENTwas found to provide guidance for including commercial off-the-shelf (COTS) hardware for use in critical applications.

Griffin, Trent↗

NASA-GRC Research Activities in High Voltage (HV) Electrical Insulation

This presentation gives an overview of recent research activities at NASA Glenn Research Center (GRC). The presentation covers research associated with materials for high voltage aerospace electrical insulation applications.

Aerospace Materials Aerospace electrical insulatio↗

Feasibility of Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

The newly patented micro-multilayer multifunctional electrical insulation (MMEI) system was developed for future electric aircraft applications which critically require lightweight but high voltage (HV), high temperature, and corona or partial discharge (PD) resistant insulation. During the initial development stages, the concept and practicability of the MMEI system were successfully validated with its exceptionally high dielectric breakdown voltages. The multilayer structures were optimized in terms of material type, individual layer thickness, and overall layer configuration along with potential mechanisms identified for its superior performance. Subsequently, scalability, manufacturability, and commercial applicability of the MMEI system were demonstrated with the 1 meter long, 3-phase HV, high power (HP) bus bar prototypes. Two prototypes, one with the conventional SOA insulation system including Mica sheet and the other with an optimized MMEI, were designed, fabricated, and tested successfully. Both prototypes passed both HiPot and PD tests up to the highest test voltage available, 15 kVAC, although the latter showed a slight increase in PD activities at 12.5 kV. However, the prototype with MMEI was 15% lighter or 12% thinner than the other one. Current efforts to significantly enhance the PD resistance of the MMEI system by employing semiconductive shielding layers, which can be also multifunctional, e.g., electromagnetic interference shielding, moisture blocking, heat dissipation, for various HV applications are also discussed in this paper.

Novel Electrical Insulation↗

Feasibility of Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

The newly patented micro-multilayer multifunctional electrical insulation (MMEI) system was developed for future electric aircraft applications which critically require lightweight but high voltage (HV), high temperature, and corona or partial discharge (PD) resistant insulation. During the initial development stages, the concept and practicability of the MMEI system were successfully validated with its exceptionally high dielectric breakdown voltages. The multilayer structures were optimized in terms of material type, individual layer thickness, and overall layer configuration along with potential mechanisms identified for its superior performance. Subsequently, scalability, manufacturability, and commercial applicability of the MMEI system were demonstrated with the 1 meter long, 3-phase HV, high power (HP) bus bar prototypes. Two prototypes, one with the conventional SOA insulation system including Mica sheet and the other with an optimized MMEI, were designed, fabricated, and tested successfully. Both prototypes passed both HiPot and PD tests up to the highest test voltage available, 15 kVAC, although the latter showed a slight increase in PD activities at 12.5 kV. However, the prototype with MMEI was 15% lighter or 12% thinner than the other one. Current efforts to significantly enhance the PD resistance of the MMEI system by employing semiconductive shielding layers, which can be also multifunctional, e.g., electromagnetic interference shielding, moisture blocking, heat dissipation, for various HV applications are also discussed in this paper.

Novel Electrical Insulation↗

Electrifying Aircraft Propulsion: Thermal Issues of Megawatt Scale Power Dense Electric Machines and Material Solutions

Aircraft are the last major mode of transportation to undergo electrification for many reasons, where the underlying reason is the sensitivity of aircraft performance to mass. This sensitivity demands that efficient, megawatt (MW)-scale high specific power density powertrains be developed to impact regional, single aisle and larger aircraft that account for the majority of fuel burn in commercial aviation. Developing MW-scale high specific power electric powertrains (machines, cables/busbars and power electronics) remains a significant challenge. While advanced power semiconductors have enabled higher voltages, densities, and operational frequencies this also leads to passing high current through smaller volumes when considering electric machines and power electronics. This poses significant thermal challenges. This is particularly true for electric machines that strive to surpass 13 kW/kg, which studies have shown to be desirable for electric aircraft propulsion. The necessity of handling high current densities to achieve MW power levels dictates that greater than 10kW of waste heat will be generated. Moreover, most of the heat is generated in the stator winding which is a mixture of electrical conductor (copper or aluminum), potting material, magnet wire (electrical) insulation and high voltage electrical insulation. Although the electrical conductor is a fantastic thermal conductor, it is also the source of the heat (carrying the electrical current) and is thermally isolated by the other materials. Simply letting the machine run at increased temperatures is an attractive idea, however the reality is that most of the suitable electric insulations and potting material candidates are not likely to satisfactorily operate at higher temperatures with reasonable life expectancies. The likelihood of developing new polymers that can satisfy the necessary functions (mechanical and electrical), operate at higher temperatures with acceptable lifetime in the near term is small. This has led the researchers at the NASA Glenn Research Center to examine electrically insulative materials in high power destiny electric machines, their thermal environment, and what solutions are realistic from a materials point of view. This presentation will touch on both the thermal challenges of electric machines and NASA Glenn’s research into material solutions.

Electric Aircraft Propulsion↗

High Voltage Breakdown Levels in Various EPC Potting Materials

This viewgraph presentation reviews exploration activities at JPL into various potting materials. Since high power space-borne microwave transmitters invariably use a vacuum tube as a final power amplifier, and this tube requires high electrode voltages for operation. The associated high voltage insulation typically represents a significant fraction of the mass of the transmitter. Since mass is always a premium resource on board spacecraft, we have been investigating materials with the potential to reduce the mass required for our applications here at JPL. This paper describes electrical breakdown results obtained with various potting materials. Conathane EN-11 (polyurethane) is the traditional HVPS encapsulant at JPL, but due to temperature limitations and durability issues it was deemed inappropriate for the particular application (i.e., CloudSat radar). The choices for the best available materials were epoxies, or silicones. Epoxies are too rigid, and were deemed inadvisable. Two silicones were further investigated (i.e.,ASTM E595- 93e2: GE RTV566(R) and Dow Corning 93-500X(R), another compound was considered (i.e., DC material, Sylgard 184(R)). "Loading" (adding filler materials) the potting compound will frequently alter the final material properties. Powdered alumina and borosilicate glass known as "microballoons" were investigated as possible loading materials. The testing of the materials is described. Each of the two loading materials offers advantages and disadvantages. The advantages and disadvantages are described.

encapsulants↗

Design and performance of a space simulation facility for long-term ion thruster system testing.

An existing space simulation facility was modified to provide the required simulated orbital environment for approximately one year of continuous testing of an operating SERT II mercury ion thruster system. Modifications included a frozen mercury collector system operating at cryogenic temperatures and automatic safety features to permit unattended operation. Special high-voltage insulators and passthroughs were designed to ensure electrical and thermal isolation in the presence of mercury vapor and deposits. The facility performance characteristics which provided the required environment without detrimental effects from mercury during the specialized test are discussed.

Mckinney, H. F.↗

High-power and 2.5 kW advanced-technology ion thruster

Investigations for improving ion thruster components in the 30 cm engineering model thruster (EMT) resulted in the demonstration of useful techniques for grid short removal and discharge chamber erosion monitoring, establishment of relationships between double ion production and thruster operating parameters, verification of satisfactory specifications on porous tungsten vaporizer material and barium impregnated porous tungsten inserts, demonstration of a new hollow cathode configuration, and specification of magnetic circuit requirements for reproducing desired magnetic mappings. The capacity of a 30 cm EMT to operate at higher beam voltages and currents (higher power) was determined. Operation at 2 A beam current and higher beam voltage is shown to be essentially equivalent to operation at 1.1 kV with regard to efficiency, lifetime and operating conditions. The only additional requirement is an improvement in high voltage insulation and propellant isolator capacity. Operation at minimum voltage and higher beam currents is shown to increase thruster discharge chamber erosion in proportion to beam current. Studies to find alternatives to molybdenum for manufacturing ion optics grids are also reported.

Poeschel, R. L.↗

Direct measurement of lower atmospheric vertical potential differences

A high impedance system has been developed to make direct measurements of the atmospheric potential difference up to several thousand feet. A tethered balloon flown from Wallops Island, Virginia was used to loft a high voltage, insulated wire and a conducting collector in a test flight to 550 meters for two days of experiments in October 1980. The balloon was equipped with a payload to measure exact altitude, wind speed and direction, and other meteorological parameters. Electric potentials of 170,000 volts at 550 meters were measured. The collected currents which could be drawn through the wire by grounding the lower end were in the 10 microamp range indicating a system impedance of about 10 to the 10th ohms. This paper describes the apparatus and details of these measurements.

Holzworth, R. H.↗

Extended-performance 8-cm ion thruster operation

The performance of an 8-cm ion thruster has been extended to 32-mN thrust, 4062-s specific impulse, and 0.033-mN/W thrust-to-power ratio. The design of this thruster is similar to the IAPS (Ion Auxiliary Propulsion System), which has a performance of 5-mN thrust, 3500-s specific impulse, and 0.036-mN/W thrust-to-power ratio. The above level of extended performance has been achieved by increasing the discharge power, ion-beam accelerating voltage, and propellant flowrate, and by modifying the propellant-vapor injection, discharge-chamber magnetic-field strength, high-voltage insulators, and electron baffle. This paper describes results obtained in characterizing the extended-performance operation of both the unmodified thruster (i.e., in an IAPS-like configuration) and the modified thruster. Lifetime-estimating measurements for the modified thruster at extended-performance conditions are also presented.

Wessel, F. J.↗

Hy-wire measurements of atmospheric potential

A method for directly measuring the electric potential drop across the lowest portion of the atmosphere by using an apparatus called Hy-wire is described. The Hy-wire system consists of a long, high-voltage, insulated conductor connected at the top to a wire-mesh braid and terminated at the bottom inside a large-diameter corona ball mounted on 1 m Teflon legs. The system impedance is near 10 billion ohms, while the grounded mode, Hy-wire draws about 10 micro-a at 500 m altitude. Around-the-clock measurements with characteristic peaks near 1530 and 1900 UT of potentials near 125,000 volts are presented, with total daily average potential near 90,000 volts at 507 m altitude. The experimental weather conditions varied from clear to local fog, except that there was only trace precipitation. The data have been interpreted in terms of the possible source of the potential variations; neither a local nor a global source is clearly indicated.

Holzworth, R. H.↗

Design for megavolt inverse-pinch plasma switch

To meet the requirements for the output switch of an ultra-high-power (greater than 30 GW) pulser, an upgrading design for an inverse-pinch plasma switch (INPIS) is considered. The hold-off voltage of 1 MV is met by adopting multistage rim-fire electrodes and using SF6 as the dielectric gas of the switch. The inductance and capacitance of the switch, which are restricted by the short rise-time (less than 0.1 microsec) requirement, were met by adjusting the dimensions of the coaxial electrodes of the switch. The input/output transmission lines attached to the switch will be immersed in oil to meet the high voltage insulation and impedance-matching requirements. Since the forwarding current is relatively low with respect to the switch capability, the lifetime of the switch is expected to exceed the requirement of 10,000 shots.

Lee, Ja H.↗

SP-100 space subsystems development progress

The space technology effort related to SP-100 subsystems is described in terms of the areas of primary focus and most significant progress. The SP-100 is briefly compared to the Voyager, and detailed descriptions of the converter subsystem, the heat-transport system, and the heat-rejection subsystem. Progress on the converter subsystem includes a high-voltage insulator composed of a single sapphire crystal, a compliant pad of coated niobium, an SiGe thermoelectric (TE) module, and a TE cell assembly. The test of the Nb1Zr piping related to the heat-transport subsystem is described, and the development is reported for the TEM pump and the gas separator. It is concluded that the critical technical issues related to the technologies have been addressed although further efforts are required. Future testing is described for the three major components of the space subsystems including the converter, pump, and the radiator.

Mondt, Jack F.↗

Electric Propulsion Technology Development for the Jupiter Icy Moons Orbiter Project

During 2004, the Jupiter Icy Moons Orbiter project, a part of NASA's Project Prometheus, continued efforts to develop electric propulsion technologies. These technologies addressed the challenges of propelling a spacecraft to several moons of Jupiter. Specific challenges include high power, high specific impulse, long lived ion thrusters, high power/high voltage power processors, accurate feed systems, and large propellant storage systems. Critical component work included high voltage insulators and isolators as well as ensuring that the thruster materials and components could operate in the substantial Jupiter radiation environment. A review of these developments along with future plans is discussed.

Source record↗

Lightweight, Durable, and Multifunctional Electrical Insulation Material Systems for High Voltage Applications

Newly developed multilayer structures of well-known polymer insulation materials significantly improved dielectric breakdown voltage, VB, or dielectric strength, K, if well-bonded, when compared to those of single material insulations or the commercial SOA systems, such as Teflon-Kapton-Teflon (TKT), at the same overall thickness. To date, the greatest improvement of the new structures from a few candidate materials, including various types of Kapton PIs and PFA or PET as bond layer (BL), was about 61% higher than that of the Kapton PI alone films, 40.1 vs. 24.9 kV, which was translated to 86.3% decrease in insulation thickness, thus significant volume and weight reduction of the final system. However, it was of interest to note that most improvements of the multilayer structures occurred at thicker overall thicknesses, above ~ 0.15 mm. Extensive analyses also showed that K of the multilayer structures increased with (i) decreasing individual layer thickness regardless of material type, (ii) increasing total accumulated thickness of PI or overall PI/BL ratio, and (iii) increasing number of interface or total number of layers, but only above the aforementioned overall thickness limit. Increases in VB of the multilayer structures were directly correlated with damage evolution and failure mode. With further material-design-process optimizations of the multilayer structures, it was expected to achieve other multifunctionalities, such as high partial discharge (PD) resistance, improved durability, EMI shielding, and high thermal dissipation in addition to high dielectric strength. These new structures can be used in various high voltage and high temperature applications, such as future hybrid or all electric aircraft wiring and power transmission as well as many other non-aerospace high power cables, electronic parts and components, printed circuit board, and so forth. The multilayer insulation system can be easily processed and manufactured with various conductor types via calendaring, compression-molding, stamping, laminating, vacuum-bagging and autoclaving, or 3D printing, even for complex 3-D components. Based on their unique structural configurations and potential capabilities, the new insulation system was identified as micro-multilayer multifunctional electrical insulation (MMEI). Patent application of the MMEI concept and current design configurations was filed for a 1-year provisional application (OAI-58834, Serial No.: 62/659,234), pending conversion to a U.S. utility application. This paper presents details of the MMEI structures, their dielectric performance analyses, potential mechanisms, and commercial scaleup feasibility assessment.

Electric aircrafts↗

Lightweight, Durable, and Multifunctional Electrical Insulation Material Systems for High Voltage Applications

Newly developed multilayer structures of well-known polymer insulation materials significantly improved dielectric breakdown voltage, VB, or dielectric strength, K, if well-bonded, when compared to those of single material insulations or the commercial SOA systems, such as Teflon-Kapton-Teflon (TKT), at the same overall thickness. To date, the greatest improvement of the new structures from a few candidate materials, including various types of Kapton PIs and PFA or PET as bond layer (BL), was about 61% higher than that of the Kapton PI alone films, 40.1 vs. 24.9 kV, which was translated to 86.3% decrease in insulation thickness, thus significant volume and weight reduction of the final system. However, it was of interest to note that most improvements of the multilayer structures occurred at thicker overall thicknesses, above ~ 0.15 mm. Extensive analyses also showed that K of the multilayer structures increased with (i) decreasing individual layer thickness regardless of material type, (ii) increasing total accumulated thickness of PI or overall PI/BL ratio, and (iii) increasing number of interface or total number of layers, but only above the aforementioned overall thickness limit. Increases in VB of the multilayer structures were directly correlated with damage evolution and failure mode. With further material-design-process optimizations of the multilayer structures, it was expected to achieve other multifunctionalities, such as high partial discharge (PD) resistance, improved durability, EMI shielding, and high thermal dissipation in addition to high dielectric strength. These new structures can be used in various high voltage and high temperature applications, such as future hybrid or all electric aircraft wiring and power transmission as well as many other non-aerospace high power cables, electronic parts and components, printed circuit board, and so forth. The multilayer insulation system can be easily processed and manufactured with various conductor types via calendaring, compression-molding, stamping, laminating, vacuum-bagging and autoclaving, or 3D printing, even for complex 3-D components. Based on their unique structural configurations and potential capabilities, the new insulation system was identified as micro-multilayer multifunctional electrical insulation (MMEI). Patent application of the MMEI concept and current design configurations was filed for a 1-year provisional application (OAI-58834, Serial No.: 62/659,234), pending conversion to a U.S. utility application. This paper presents details of the MMEI structures, their dielectric performance analyses, potential mechanisms, and commercial scaleup feasibility assessment.

Multifunctional↗

Current collection from the space plasma through defects in high voltage solar array insulation

For spacecraft operation in the near Earth environment, solar cell arrays constitute the major source of reliable long term power. Optimization of mass and power efficiency results in a general requirement for high voltage solar arrays. The space plasma environment, though, can result in large currents being collected by exposed solar cells. The solution of a protective covering of transparent insulation is not a complete solution, inasmuch as defects in the insulation result in anomalously large currents being collected through the defects. Tests simulating the electron collection from small defects in an insulation have shown that there are two major collection modes. The first mode involves current enhancement by means of a surface phenomenon involving the surrounding insulator. In the second mode the current collection is enhanced by vaporization and ionization of the insulators materials, in addition to the surface enhancement of the first mode. A model for the electron collection is the surface enhanced collection mode was developed. The model relates the secondary electron emission yield to the electron collection. It correctly predicts the qualitative effects of hole size, sample temperature and roughening of sample surface. The theory was also shown to predict electron collection within a factor of two for the polymers teflon and polyimide.

Stillwell, R. P.↗