Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ab initio investigation of elastic properties of dilute Cu alloys for high-gradient accelerating structures

The elastic properties and solid solution strengthening of several Cu alloys that may be promising for high gradient applications were studied using ab initio calculations based on density functional theory. Specifically, the temperature and solute concentration dependence of elastic properties including bulk and shear moduli, thermal expansion coefficient, and heat capacity of these alloys were calculated. We found that the bulk and shear moduli are linearly dependent on the solute concentration in the dilute regime and change significantly for different Cu alloys. The thermal expansion coefficient and heat capacity are comparatively less sensitive to solute concentrations. Solid solution strengthening is observed to be linearly correlated with the change of lattice parameter of Cu. This work provides an in-depth understanding of the elastic properties of Cu alloys, which is key for predicting their performance at high gradient in normal conducting accelerating structures.

36 MATERIALS SCIENCE↗

High Gradient Accelerating Structures for Carbon Therapy Linac

Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

Kutsaev, Sergey↗

Materials and technological processes for High-Gradient accelerating structures: new results from mechanical tests of an innovative braze-free cavity.

Pure oxygen-free high-conductivity copper is a widely used material for manufacturing accelerating cavities working at room temperature. Several studies attempted to explain limitations associated with the maximum allowed field gradients and the behaviour of vacuum RF breakdown in copper accelerating structures through generation and movement of dislocations under stresses associated with RF electric and magnetic fields. Pure copper and also copper alloys undergo mechanical and thermal treatments to be hardened and strengthened during manufacturing, although their mechanical properties significantly change after heating above 590°C. High temperature brazing and diffusion bonding are assembly methods widely used to manufacture ultra-high vacuum accelerating devices. However, these processes, occurring at about 800–1000°C, significantly affect the mechanical properties of copper and copper alloys. We introduce here a novel Tungsten Inert Gas welding procedure, which is fast and keeps the high-gradient surfaces of the cavity and other components well below the copper annealing temperature. This process may be successfully used to manufacture copper-based accelerating components. This technology further preserves the hardness and cleanliness of copper in order to achieve the maximum accelerating gradient.

47 OTHER INSTRUMENTATION↗

High Gradient Accelerator Cavities Using Atomic Layer Deposition

In the Phase I program, Calabazas Creek Research, Inc. (CCR), in collaboration with North Carolina State University (NCSU), fabricated copper accelerator cavities and used Atomic Layer Deposition (ALD) to apply thin metal coatings of tungsten and platinum. It was hypothesized that a tungsten coating would provide a robust surface more resistant to arcing and arc damage. The platinum coating was predicted to reduce processing time by inhibiting oxides that form on copper surfaces soon after machining. Two sets of cavity parts were fabricated. One was coated with 35 nm of tungsten, and the other with approximately 10 nm of platinum. Only the platinum cavity parts could be high power tested during the Phase I program due to schedule and funding constraints. The platinum coated cavity exhibit poor performance when compared with pure copper cavities. Not only did arcing occur at lower power levels, but the processing time was actually longer. There were several issues that contributed to the poor performance. First, machining of the base copper cavity parts failed to achieve the quality and cleanliness standards specified to SLAC National Accelerator Center. Secondly, the ALD facilities were not configured to provide the high levels of cleanliness required. Finally, the nanometer coating applied was likely far too thin to provide the performance required. The coating was ablated or peeled from the surface in regions of high fields. It was concluded that the current ALD process could not provide improved performance over cavities produced at national laboratories using dedicated facilities.

43 PARTICLE ACCELERATORS↗

Multi-MW K-Band Harmonic Multiplier: RF Source For High-Gradient Accelerator R and D

A preliminary design is presented for a two-cavity harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power at selected frequencies in K-band (18-26.5 GHz) using as an RF driver an XK-5 S-band klystron (2.856 GHz). The device is to be built with a TE{sub 111} rotating mode input cavity and interchangeable output cavities running in the TE{sub n11} rotating mode, with n = 7,8,9 at 19.992, 22.848, and 25.704 GHz. An example for a 7{sup th} harmonic multiplier is described, using a 250 kV, 20 A injected laminar electron beam; with 10 MW of S-band drive power, 4.7 MW of 20-GHz output power is predicted. Details are described of the magnetic circuit, cavities, and output coupler.

43 PARTICLE ACCELERATORS↗

Multi-MW K-Band 7th Harmonic Multiplier for High-Gradient Accelerator R&D

A preliminary design and current status are presented for a two-cavity 7th harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power in K-band using as its RF driver an XK-5 S-band klystron (2.856 GHz). The multiplier is to be built with a TE{sub 111} rotating mode input cavity and interchangeable output cavities, a principal example being a TE{sub 711} rotating mode cavity running at 20 GHz. The design that is described uses a 250 kV, 20 A injected laminar electron beam. With 8.5 MW of S-band drive power, 4.4 MW of 20-GHz output power is predicted. The design uses a gun, magnetic coils, and beam collector from an existing waveguide 7th harmonic multiplier. The gun has been re-conditioned and the desired operating parameters have been achieved.

43 PARTICLE ACCELERATORS↗

Analysis of a Symmetric Terahertz Dielectric-Lined Rectangular Structure for High Gradient Acceleration

We study, using computational methods based on analytic theory as well as a PIC code, the wakefields set up in a seven-zone symmetric rectangular THZ structure, and find that for overall transverse x/y dimensions 2.121 mmx0.6 mm, two 5-GeV drive bunches (3 nC, with x/y/z dimensions 0.3/0.3/0.12 mm{sup 3} as available at SLAC) will set up an axial wakefield {approx}350 MV/m in the witness channel, with a transformer ratio {approx}18-20. The symmetry of the structure ensures not only that small transverse forces are imposed on the witness bunch, but also that the two components of transverse force are equal and opposite at the bunch location so as to enable dynamical stabilization in an accelerator comprising many modules. Transverse forces on the drive bunch tails may allow bunches to move {approx}0.5-1 m without suffering excessive erosion.

43 PARTICLE ACCELERATORS↗

Magnetized Plasma-filled Waveguide: A New High-Gradient Accelerating Structure

Electromagnetic waves confined between the metal plates of a plasma-filled waveguide are investigated. It is demonstrated that when the plasma is magnetized along the metallic plates, there exists a luminous accelerating wave propagating with a very slow group velocity. It is shown that the magnetized plasma 'isolates' the metal wall from the transverse electric field, thereby reducing potential breakdown problems. Applications of the metallic plasma-filled waveguide to particle accelerations and microwave pulse manipulation are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modified Magnicon for High-Gradient Accelerator \&

A self-consistent design is described of a modified 34.3 GHz magnicon amplifier with a TE311-mode output cavity, to replace the existing magnicon at Yale Beam Physics Lab Test Facility whose output cavity operates in the TM310 mode. The main g oal for the new design is to achieve robust reliable operation. This is expected since tube performance according to simulations is largely insensitive to the magnitude of external dc magnetic fields, including imperfections in magnetic field profile; small changes in gun voltage and current; changes in electron beam radial size; and even poorly matched external circuitry. The new tube, as with its predecessor, is a third harmonic amplifier, with drive and deflection gain cavities near 11.424 GHz and output cavity at 34.272 GHz. The design calculations predict stable output of power of 20-27 MW at a 10 Hz repetition rate in pulses up to 1.3 microsec long, with a low probability of breakdown in the output cavity because of low electric fields (less tha n 650 kV/cm).

43 PARTICLE ACCELERATORS↗

Compact high gradient ion accelerating structure

A high gradient linear accelerating structure can propagate high frequency waves at a negative harmonic to accelerate low-energy ions. The linear accelerating structure can provide a gradient of 50 MV/m for particles at a β of between 0.3 and 0.4. The high gradient structure can be a part of a linear accelerator configured to provide an energy range from an ion source to 450 MeV/u for 12 C 6+ and 250 MeV for protons. The linear accelerator can include one or more of the following sections: a radiofrequency quadrupole (RFQ) accelerator operating at the sub-harmonic of the S-band frequency, a high gradient structure for the energy range from ˜45 MeV/u to ˜450 MeV/u.

Kutsaev, Sergey↗