SEARCH · Search NASA
Results for “High heat”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Morphological and nanomechanical changes in tungsten in high heat flux conditions
Abstract Morphological and nanomechanical alteration of tungsten in extreme environments, like those in edge localized modes in nuclear fusion environments, up to 46.3 GWm −2 heat fluxes were experimentally simulated using electrothermal plasma. Surface and subsurface damage to the tungsten is seen mainly in the form of pore formation, cracks, and resolidified melt instabilities. Mirco voids, rosette-type microfeatures, core-shell structure, particle enrichment, and submicron channels all manifest in the damaged subsurface. The formation of voids in the subsurface was determined to originate from the ductile fracture of hot tungsten by plastic flow but not developed to cracking. The voids were preferentially settled in grain boundaries, interfaces. The directionality of elongated voids and grains is biased to the heat flow vector or plasma pathway, which is the likely consequence of the thermally driven grain growth and sliding in the high-temperature conditions. The presence of a border between the transient layer and heat-affected zone is observed and attributed to plasma shock and thermal spallation of fractural tungsten at high temperature. Plasma peening-like hardening effects in tungsten were observed in the range of 22.7–46.3 GWm −2 but least in the case of the lowest heat flux, 12.5 GWm −2 .
Development and modeling for a small-scale, rapidly heated high explosives initiation time (HEIT) experiment
Most small-scale assessments of explosive sensitivity, including the popular drop-weight impact test, convolute thermal and mechanical phenomena to the extent that it has been extremely challenging to decipher how an explosive ignites and propagates reactions. For instance, an impact generates heat through a range of dissipation mechanisms, which can in turn, depending on the reaction rates of the explosive, lead to chemical decomposition. To deconvolute the various contributions to the sub-shock initiation and propagation of explosive reactions, we describe the development and modeling of the High Explosives Initiation Time (HEIT) test - a new, small-scale, high-throughput experiment designed to rapidly heat milligram quantities of energetic materials confined within small diameter steel needles. Specifically, we have modeled and designed a 250 joule pulsed power system capable of rapidly delivering electrical current to the needles, resulting in rapid heat delivery to the sample. In conclusion, the energy deposition rate into the sample is controlled by different transmission line topologies. Modeling in COMSOL is performed to understand the energy required to heat up the explosive sample.
Development of Readily Available & Robust High Heat Flux Gardon Gauges
Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.
Charlo Junior High Heating, Ventilation, and Air Conditioning (HVAC) Upgrade and Energy Improvements
The Charlo School District 7J is located at 404 1st Ave West, in Charlo, Montana. The District has 55,778 ft² of facility space serving students from grades K through 12 in the Western Montana community of Charlo, within the Flathead Indian Reservation. The campus is made up of four primary buildings which are the elementary building, administration and high school, a junior high wing with a shop, and the gymnasium/multipurpose building. This project will focus on the needs of the Junior High Facility.
Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling
Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.
Design and modeling of hollow micropillars evaporator for thermal management in high heat flux applications: Numerical analysis
Not Available
Hermeticity of SiC/SiC composite and monolithic SiC tubes irradiated under radial high-heat flux
Demonstration of hermetic SiC fiber–reinforced SiC matrix composite cladding under normal operating environments has been identified as one of the most critical feasibility issues for accident-tolerant fuel cladding in light-water reactors. This study provides critical experimental data needed for understanding the effects of irradiation on hermeticity. SiC composite and monolithic tubes were neutron-irradiated to 2 displacements per atom with and without a nominal radial heat flux of 0.6 MW/m2 to produce a simulated in-pile stress state for the normal operation of a light-water reactor. The through-thickness temperature gradient under irradiation results in a gradient in swelling, which causes a significant stress buildup. Such irradiation-induced stress was modeled using a commercial finite element analysis code. The radial heat flux–irradiation synergism was experimentally investigated by constructing a special irradiation capsule and evaluating the helium hermeticity of the specimens. The simulated stress state exhibited a near equi-biaxial tensile axial and hoop stress of ~150 MPa at the inner surface of the SiC composite tube. This stress level is potentially beyond the matrix cracking stress. Degradation of hermeticity of the SiC composite tubes was observed after irradiation, indicating irradiation-induced cracking, whereas the irradiated monolithic SiC tubes remained hermetic. In conclusion, the results indicate that loss of hermeticity caused by radiation-induced microcracking is a potential issue for SiC composite cladding, depending on the magnitude of the temperature gradients. Coating the outer surface of the cladding was identified as a mitigation strategy that might overcome the cracking issue.
Leveraging high heating rates to attain desirable reaction products in Al/Zr/C nanocomposites
Not Available
Comparing lithium vapor box designs in a high heat flux scenario using SOLPS-ITER
Not Available
Thermal Evaluation of the SAVY-4000 1 Quart Container at High Heat Loads
The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.
The Characterization of a High Heat Flux Gardon Gauge
Explore the source record for details and available documents.
Developing a superconducting undulator withstanding high heat load
Explore the source record for details and available documents.
High Heat Flux Thermal Management using CuW Microchannel Heat Sinks and FC3283
Explore the source record for details and available documents.
District heating utilizing waste heat of a data center: High-temperature heat pumps
Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.
A novel 3-D pulsating heat pipe module for high heat-flux applications
This study proposed a novel pulsating heat pipes (PHP) for high-flux thermal module. According to the open literature, the maximum value of the heat flux is 23.7 W∙cm –2 handled by PHP, which is far behind industry requirements. Therefore, the present study proposes a novel 3D PHP suitable for high heat-flux applications. The PHP were experimentally tested for different working fluids, including methanol and water. Furthermore, the experiments were performed to analyze the influence of various operating parameters, such as filling ratio (25–60%), heat load (100–800 W), and air flow rate 100–250 cubic feet per minute (CFM). In this work, the results showed that this PHP can sustain a heat flux up to 70 W∙cm –2 with the maximum case temperature under 80 °C, which is approximately three times higher than the available literature. Furthermore, the performance of the PHP module was compared against the commercial module with wicked heat pipe. The PHP exhibited about 7% higher heat dissipation compared to the commercial module. Since the proposed module uses simple copper tubes in its construction over the wicked structure used in commercial module, the novel 3D PHP module provides additional economic and mass production capability.
Exploration of Heat-Driven Ejector High-Temperature Heat Pumps
Heat-driven ejector heat pumps use a supersonic ejector as a thermo-compressor to replace the mechanical compressor. Supersonic ejectors have many advantages in high-temperature heat pump (HTHP) applications, including high operating temperature tolerance, no need for lubrication, low maintenance, and low cost. The coefficient of performance of ejector HTHPs could be improved by selecting binary fluids with unique thermodynamic properties. Although supersonic ejectors have been widely used in refrigeration systems, their application in spaces and water heating is limited. This study explores the theoretical potential of ejector HTHPs with a sink temperature of 100°C–130°C and a lift temperature of 10°C–30°C. Ejector HTHPs were evaluated with single-fluid ejectors (SFEs) and binary-fluid ejectors (BFEs). A comprehensive, geometry-free theoretical model of BFEs was developed to predict the theoretical maximum entrainment ratios. HFE7500 and R718 (water) were selected as working fluids for SFEs and BFEs. SFEs operating with R718 provided a higher coefficient of performance of ejector HTHPs than SFEs operating with HFE7500 and BFEs. This study preliminarily demonstrates the technical potential of ejector HTHP applications in recovering moderate-temperature heat sources