Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hot Box testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Varestraint test for refractory metals, task 2

The principles of the Varestraint test were applied to the evaluation of refractory metal alloys. This required development of a special test apparatus employing a modest specimen size for improved economy and compatible with the high purity inert atmosphere required for welding these alloys. Minimum specimen size is desirable because of the high cost of these alloys and also to permit timely testing of limited production developmental alloys. The Varestraint apparatus satisfies these requirements by providing a timely and economic test for hot crack sensitivity. This test can be used both for alloy development and production surveillance. The test apparatus was designed for use in vacuum purged dry boxes and is completely compatible with high purity inert atmosphere. Augmented strain can be varied continuously from 1/4% thru 4%. In addition to varying the augmented strain, the primary Varestraint variable, the effect on hot cracking of varying other weld parameters such as unit weld length heat input have also been studied. Test reproducibility, in terms of bending or strain rate, was demonstrated using high speed photography.

Lessmann, G. G.↗

Measuring Hydroxylammonium, Nitrate, and Nitrite Concentration with Raman Spectroscopy for 238 Pu Supply Program

Optical spectroscopy has great potential to improve the timeliness of important analytical measurements for the 238 Pu Supply Program by enabling real-time analysis of process solutions within radiochemical hot cells. Hydroxylammonium (H 3 NOH + ]), nitrate (NO 3 - ), and nitrite (NO 2 - ) are three important molecular species present in multiple aqueous streams throughout the program’s flow sheet. The concentration of each species normally goes uncharacterized during processing. However, rapid quantification may benefit the program because uncertainties in kinetic redox expressions describing hydroxylammonium (HA) and nitrite reactions with Np and Pu leads to uncertainty in process model predictions for solvent extraction runs. HA concentration is normally quantified using ion chromatography, a technique that requires diluted grab samples taken out of the hot cell and analyzed off-line. Here we evaluate Raman spectroscopy for determining the concentration of H 3 NOH + , NO 3 - , and NO 2 - in benchtop tests to determine limits of detection. We also consider the possibility of using Raman spectroscopy in both glove box and hot cell environments for rapid analysis and pinpoint additional development opportunities needed to make this application successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Special Testing for Modules Deployed in Hot Use Environments - Are We Doing This in a Low-Cost Way?

The proposed new IEC standard will address the test temperature requirements in IEC 61215 (module design), IEC 61730 (module safety), IEC 62790 (junction box safety) and IEC 62852 (connectors), and will provide guidelines to modify temperature limits in four existing standards to better describe module performance in hotter climates. This workshop includes four presentations: Special Testing for Modules Deployed in Hot Use Environments - Are We Doing This in a Low-Cost Way?, Experimental Evidence, Why the highest temperatures are the most stressful to PV modules during thermal cycling, and Safety Aspects for Modules Deployed in Hot Use Environments.

14 SOLAR ENERGY↗

Trial Run of a Junction-Box Attachment Test for Use in Photovoltaic Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development and manufacturing process control. There are historical incidences of adverse effects (e.g., fires), caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp-heat', 'thermal-cycle', or 'creep' tests within the IEC qualification protocol is proposed to verify the basic robustness of the adhesion system. The details of the proposed test are described, in addition to a trial run of the test procedure. The described experiments examine 4 moisture-cured silicones, 4 foam tapes, and a hot-melt adhesive used in conjunction with glass, KPE, THV, and TPE substrates. For the purpose of validating the experiment, j-boxes were adhered to a substrate, loaded with a prescribed weight, and then subjected to aging. The replicate mock-modules were aged in an environmental chamber (at 85 deg C/85% relative humidity for 1000 hours; then 100 degrees C/<10% relative humidity for 200 hours) or fielded in Golden, Miami, and Phoenix for 1 year. Attachment strength tests, including pluck and shear test geometries, were also performed on smaller component specimens.

14 SOLAR ENERGY↗

Trial-Run of a Junction-Box Attachment Test for Use in Photovoltaic Module Qualification: Preprint

Engineering robust adhesion of the junction box (j-box) is a hurdle typically encountered by photovoltaic module manufacturers during product development and manufacturing process control. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp-heat,' 'thermal-cycle,' or 'creep' tests within the IEC qualification protocol is proposed to verify the basic robustness of the adhesion system. The details of the proposed test are described, in addition to a trial-run of the test procedure. The described experiments examine four moisture-cured silicones, four foam tapes, and a hot-melt adhesive used in conjunction with glass, KPE, THV, and TPE substrates. For the purpose of validating the experiment, j-boxes were adhered to a substrate, loaded with a prescribed weight, and then subjected to aging. The replicate mock-modules were aged in an environmental chamber (at 85 degrees C/85% relative humidity for 1000 hours; then 100 degrees C/<10% relative humidity for 200 hours) or fielded in Golden (CO), Miami (FL), and Phoenix (AZ) for one year. Attachment strength tests, including pluck and shear test geometries, were also performed on smaller component specimens.

14 SOLAR ENERGY↗

Renovation of CPF (Chemical Processing Facility) for Development of Advanced Fast Reactor Fuel Cycle System

CPF (Chemical Processing Facility) was constructed at Nuclear Fuel Cycle Engineering Laboratories of JAEA (Japan Atomic Energy Agency) in 1980 as a basic research field where spent fuel pins from fast reactor (FR) and high level liquid waste can be dealt with. The renovation consists of remodeling of the CA-3 cell and the laboratory A, installation of globe boxes, hoods and analytical equipments to the laboratory C and the analytical laboratory. Also maintenance equipments in the CA-5 cell which had been out of order were repaired. The CA-3 cell is the main cell in which important equipments such as a dissolver, a clarifier and extractors are installed for carrying out the hot test using the irradiated FR fuel. Since the CPF had specialized originally in the research function for the Purex process, it was desired to execute the research and development of such new, various reprocessing processes. Formerly, equipments were arranged in wide space and connected with not only each other but also with utility supply system mainly by fixed stainless steel pipes. It caused shortage of operation space in flexibility for basic experimental study. Old equipments in the CA-3 cell including vessels and pipes were removed after successful decontamination, and new equipments were installed conformably to the new design. For the purpose of easy installation and rearranging the experimental equipments, equipments are basically connected by flexible pipes. Since dissolver is able to be easily replaced, various dissolution experiments is conducted. Insoluble residue generated by dissolution of spent fuel is clarified by centrifugal. This small apparatus is effective to space-saving. Mini mixer settlers or centrifugal contactors are put on to the prescribed limited space in front of the backside wall. Fresh reagents such as solvent, scrubbing and stripping solution are continuously fed from the laboratory A to the extractor by the reagent supply system with semi-automatic observation system. The in-cell crane in CA-5 was renovated to increase driving efficiency. At the renovation for the in-cell crane, full scale mockup test and 3D simulation test had been executed in advance. After the renovation, hot tests in the CPF had been resumed from JFY 2002. New equipments such as dissolver, extractor, electrolytic device, etc. were installed in CA-3 conformably to the new design laid out in order to ensure the function and space. Glove boxes in the analysis laboratory were renewed in order to let it have flexibility from the viewpoint of conducting basic experiments (ex. U crystallization). Glove boxes and hoods were newly installed in the laboratory A for basic research and analysis, especially on MA chemistries. One laboratory (the laboratory C) was established to research about dry reprocessing. The renovation of the CPF has been executed in order to contribute to the development on the advanced fast reactor fuel cycle system, which will give us many sort of technical subject and experimental theme to be solved in the 2. Generation of the CPF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmark panels

Results are presented for an analytical and experimental study of curved, stiffened composite panels for a commercial transport aircraft. Five panels representative of fuselage crown design alternatives were fabricated for concept evaluation. These panels are scheduled to be tested in the Pressure Box Test Machine at NASA Langley Research Center. The panels are characterized by a 122 in. radius, tow-placed skins, hot-drape-formed hat-section stringers, and braided/RTM J-section frames. A geometrically nonlinear finite element analysis was conducted to support the development of test fixturing and to provide predictions of undamaged panel response. A strain softening model for damaged structures is described and used to predict the response of damaged panels. Results for a study of the stringer-frame intersection ('mousehole') design detail are also presented. Bonded frame pull-off tests and supporting analyses are described.

T H Walker↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification: Preprint

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed toverify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results,a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observedfailure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Prototyping phase of the high heat flux scraper element of Wendelstein 7-X

The water-cooled high heat flux scraper element aims to reduce excessive heat loads on the target element ends of the actively cooled divertor of Wendelstein 7-X. Its purpose is to intercept some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper element has 24 identical plasma facing components (PFCs) divided into 6 modules. One module has 4 PFCs hydraulically connected in series by 2 water boxes. A PFC, 247 mm long and 28 mm wide, has 13 monoblocks made of CFC NB31 bonded by hot isostatic pressing onto a CuCrZr cooling tube equipped with a copper twisted tape. 4 full-scale prototypes of PFCs have been successfully tested in the GLADIS facility up to 20 MW/m 2 . The difference observed between measured and calculated surface temperatures is probably due to the inhomogeneity of CFC properties. The design of the water box prototypes has been detailed to allow the junction between the cooling pipe of the PFCs and the water boxes by internal orbital welding. In conclusion, the prototypes are presently under fabrication.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geoscience Laser Altimetry System (GLAS) Loop Heat Pipe Anomaly and On Orbit Testing

The Geoscience Laser Altimetry System (GLAS) is the sole instrument on the ICESat Satellite. On day 230 of 2003, the GLAS Component Loop Heat Pipe (CLHP) entered a slow circulation mode that resulted in the main electronics box reaching its hot safing temperature, after which the entire instrument was turned off. The CLHP had a propylene working fluid and was actively temperature controlled via a heater on the compensation chamber. The slow circulation mode happened right after a planned propulsive yaw maneuver with the spacecraft. It took several days to recover the CLHP and ensure that it was still operational. The recovery occurred after the entire instrument was cooled to survival temperatures and the CLHP compensation chamber cycled on a survival heater. There are several theories as to why this slow circulation mode exhibited itself, including: accumulation of Non-Condensible Gas (NCG), the secondary wick being under designed or improperly implemented, or an expanded (post-launch) leak across the primary wick. Each of these is discussed in turn, and the secondary wick performance is identified as the most likely source of the anomalous behavior. After the anomaly, the CLHP was controlled to colder temperatures to improve its performance (as the surface tension increases with lower temperature, as does the volume of liquid in the compensation chamber) and only precursor pulses occurred later in the mission. After GLAS s last laser failed, in late 2009, a decision was made to conduct engineering tests of both LHPs to try and duplicate this flight anomaly. The engineering tests consisted of control setpoint changes, sink changes, and one similar propulsive Yaw maneuver. The only test that showed any similar anomaly precursors on the CLHP was the propulsive maneuver followed by a setpoint increase. The ICESat Satellite was placed in a decaying orbit and ended its mission on August 30, 2010 in Barents Sea.

Baker, Charles↗

Static internal performance of a nonaxisymmetric vaned thrust reverser with flow splay capability

An investigation was conducted in the Static Test Facility of the Langley 16-Foot Transonic Tunnel on a dual-port, nonaxisymmetric, block-and-turn type thrust reverser model with vane cascades in the reverser ports which turned the flow in the splay direction and aided in turning the flow in the reverse direction. Splaying reverser flow is a method of delaying to lower landing ground roll speeds the reingestion of hot exhaust flow into the inlets. Exhaust flow splay can also help prevent the impingement of hot exhaust gases on the empennage surfaces when the reverser is integrated into an actual airframe. The vane cascades consisted of two sets of perpendicular vanes with a variable number of turning and splay vanes. A skewed vane box was also tested which had only one set of vanes angled to provide both turning and splay. Vane cascades were designed to provide different amounts of flow splay in the top and bottom ports. Inner doors, trim tabs, and an orifice plate all provided means of varying the port area for reverser flow modulation. The outer door position was varied as a means of influencing the flow reverse angle. Nozzle pressure ratio was varied from 1.75 to approximately 6.00.

Bangert, Linda S.↗

Low-Cost Options for Moderate Levels of Mercury Control

This is the final technical report for a three-site project that is part of an overall program funded by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL) and industry partners to obtain the necessary information to assess the feasibility and costs of controlling mercury from coal-fired utility plants. This report summarizes results from tests conducted at MidAmerican's Louisa Generating Station and Entergy's Independence Steam Electric Station (ISES) and sorbent screening at MidAmerican's Council Bluffs Energy Center (CBEC) (subsequently renamed Walter Scott Energy Center (WSEC)). Detailed results for Independence and Louisa are presented in the respective Topical Reports. As no full-scale testing was conducted at CBEC, screening updates were provided in the quarterly updates to DOE. ADA-ES, Inc., with support from DOE/NETL, EPRI, and other industry partners, has conducted evaluations of EPRI's TOXECON II{trademark} process and of high-temperature reagents and sorbents to determine the capabilities of sorbent/reagent injection, including activated carbon, for mercury control on different coals and air emissions control equipment configurations. An overview of each plant configuration is presented: (1) MidAmerican's Louisa Generating Station burns Powder River Basin (PRB) coal in its 700-MW Unit 1 and employs hot-side electrostatic precipitators (ESPs) with flue gas conditioning for particulate control. This part of the testing program evaluated the effect of reagents used in the existing flue gas conditioning on mercury removal. (2) MidAmerican's Council Bluffs Energy Center typically burns PRB coal in its 88-MW Unit 2. It employs a hot-side ESP for particulate control. Solid sorbents were screened for hot-side injection. (3) Entergy's Independence Steam Electric Station typically burns PRB coal in its 880-MW Unit 2. Various sorbent injection tests were conducted on 1/8 to 1/32 of the flue gas stream either within or in front of one of four ESP boxes (SCA = 542 ft{sup 2}/kacfm), specifically ESP B. Initial mercury control evaluations indicated that although significant mercury control could be achieved by using the TOXECON II{trademark} design, the sorbent concentration required was higher than expected, possibly due to poor sorbent distribution. Subsequently, the original injection grid design was modeled and the results revealed that the sorbent distribution pattern was determined by the grid design, fluctuations in flue gas flow rates, and the structure of the ESP box. To improve sorbent distribution, the injection grid and delivery system were redesigned and the effectiveness of the redesigned system was evaluated. This project was funded through the DOE/NETL Innovations for Existing Plants program. It was a Phase II project with the goal of developing mercury control technologies that can achieve 50-70% mercury capture at costs 25-50% less than baseline estimates of $50,000-$70,000/lb of mercury removed. Results from testing at Independence indicate that the DOE goal was successfully achieved. Further improvements in the process are recommended, however. Results from testing at Louisa indicate that the DOE goal was not achievable using the tested high-temperature sorbent. Sorbent screening at Council Bluffs also indicated that traditional solid sorbents may not achieve significant mercury removal in hot-side applications.

01 COAL, LIGNITE, AND PEAT↗

Micro-environmental control for efficient local heating: CFD simulation and manikin test verification

Micro-environment control system has been proved to be able to provide local thermal comfort control. It also has the potential to save building energy by relaxing the control on the unoccupied space. This work aims at designing an efficient heating delivering device (HDD) to locally warm the person to restore thermal comfort when the unoccupied space temperature is reduced from 70.0 °F to 66.0 °F to save the energy. A three-stage approach was developed for designing the HDD including the initial stage of developing by CFD simulation, the second stage of manikin test verification and final stage of human subject test confirmation. The results of the first two stages were presented and discussed in this work. It was shown that convective heating was not efficient enough unless a confinement box was used to hold the hot air around the legs and feet. A more ergonomically friendly design of using a foot warmer was finally proved to be a better solution for individually heating by both simulation and experiments since it can heat the occupant sufficiently. The ability of using CFD to predict heat loss from the clothed human body and its limitation was also investigated. It was found that with proper clothing insulation, the CFD can give a reasonable prediction, although simulating the clothing as a layer of certain thermal resistance might be problematic regarding the structure and permeability of the clothing material. In conclusion, a more appropriate method for simulating the clothing was needed for better prediction in the future.

42 ENGINEERING↗

Evaluation of Embedded VIPs for Use in the Building Envelope

An objective for expanded use of vacuum insulation panel (VIP) products in buildings will be assisted by an understanding of the relationship between small-scale laboratory thermal measurements and large-scale tests of building components. Thermal resistances of a typical element of VIP embedded in closed-cell cellular plastic (foam) insulation obtained with a heat flow meter (HFM) apparatus are compared with results obtained with a hot-box facility for a building component. Small-scale samples of the foam-VIP composites were measured in single- and multi-transducer HFMs. The multi-transducer HFM was used to determine the heat flow distribution across the different sections of the VIP, i.e. center-of-panel vs. edges and joints. These measurements enable validation of numerical models, which can be utilized to model and evaluate large-scale building components containing VIPs.

Biswas, Kaushik↗

Mars Science Laboratory Rover System Thermal Test

On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

Novak, Keith S.↗

Mars Science Laboratory Rover System Thermal Test

On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

Novak, Keith S.↗

HOST liner cyclic facilities: Facility description

A quartz lamp box, a quartz lamp annular rig, and a low pressure liner cyclic can rig planned for liner cyclic tests are described. Special test instrumentation includes an IR-TV camera system for measuring liner cold side temperatures, thin film thermocouples for measuring liner hot side temperatures, and laser and high temperature strain gages for obtaining local strain measurements. A plate temperature of 2,000 F was obtained in an initial test of an apparatus with three quartz lamps. Lamp life, however, appeared to be limited for the standard commercial quartz lamps available. The design of vitiated and nonvitiated preheaters required for the quartz lamp annular rig and the cyclic can test rigs is underway.

Schultz, D.↗