Search NASASearch

SEARCH · Search NASA

Results for “Human head model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Retinal Image Quality Assessment for Spaceflight-Induced Visual Impairment Study

Medical reports have identified visual impairments as a risk associated with extended exposure to microgravity. Etiology of these ocular changes is currently unknown. Current hypotheses propose cephalad fluid shifts resulting from microgravity as the primary cause of ocular damage. One approach to studying ocular response to microgravity is by examining possible changes in retinal blood vessels using a NASA model of microgravity, the head-down tilt (HDT) of human subjects undergoing prolonged bed rest (BR). Retinal vessels in astronauts and BR subjects are monitored by Heidelberg Spectralis infrared (IR) imaging, in which retinal image quality is limited by insufficient resolution of small vessels. Yet small vessels respond and remodel most actively to physiological stress.For our NASA study of BR subjects, we identify retinal image quality as thecapability to capture vascular detail to acceptable resolution of small vessels. We therefore are analyzing Spectralis images acquired with fluorescein angiography(FA), where increased contrast significantly improves image resolution. The FA images are of normal subjects participating in a clinical study on diabeticretinopathy (US National Institutes of Health). We hypothesize that FA Spectralis images are of superior quality compared to non-FA Spectralis IR images.

Rodrigo Rene Rai Munoz Abujder

Spectral analysis of resting cardiovascular variables and responses to oscillatory LBNP before and after 6 degree head dowm bedrest

A major focus of our research program is to develop noninvasive procedures for determining changes in cardiovascular function associated with the null gravity environment. We define changes in cardiovascular function to be (1) the result of the regulatory system operating at values different from 'normal' but with an overall control system basically unchanged by the null gravity exposure, or (2) the result of operating with a control system that has significantly different regulatory characteristics after an exposure. To this end, we have used a model of weightlessness that consisted of exposing humans to 2 hrs. in the launch position, followed by 20 hrs. of 6 deg head down bedrest. Our principal objective was to use this model to measure cardiovascular responses to the 6 deg head down bedrest protocol and to develop the most sensitive 'systems identification' procedure for indicating change. A second objective, related to future experiments, is to use the procedure in combination with experiments designed to determine the degree to which a regulatory pathway has been altered and to determine the mechanisms responsible for the changes.

Knapp, Charles F.

Accurate Visual Heading Estimation at High Rotation Rate Without Oculomotor or Static-Depth Cues

It has been claimed that either oculomotor or static depth cues provide the signals about self-rotation necessary approx.-1 deg/s. We tested this hypothesis by simulating self-motion along a curved path with the eyes fixed in the head (plus or minus 16 deg/s of rotation). Curvilinear motion offers two advantages: 1) heading remains constant in retinotopic coordinates, and 2) there is no visual-oculomotor conflict (both actual and simulated eye position remain stationary). We simulated 400 ms of rotation combined with 16 m/s of translation at fixed angles with respect to gaze towards two vertical planes of random dots initially 12 and 24 m away, with a field of view of 45 degrees. Four subjects were asked to fixate a central cross and to respond whether they were translating to the left or right of straight-ahead gaze. From the psychometric curves, heading bias (mean) and precision (semi-interquartile) were derived. The mean bias over 2-5 runs was 3.0, 4.0, -2.0, -0.4 deg for the first author and three naive subjects, respectively (positive indicating towards the rotation direction). The mean precision was 2.0, 1.9, 3.1, 1.6 deg. respectively. The ability of observers to make relatively accurate and precise heading judgments, despite the large rotational flow component, refutes the view that extra-flow-field information is necessary for human visual heading estimation at high rotation rates. Our results support models that process combined translational/rotational flow to estimate heading, but should not be construed to suggest that other cues do not play an important role when they are available to the observer.

Stone, Leland S.

Synthesis of Speaker Facial Movement to Match Selected Speech Sequences

A system is described which allows for the synthesis of a video sequence of a realistic-appearing talking human head. A phonic based approach is used to describe facial motion; image processing rather than physical modeling techniques are used to create video frames.

phonics speech synthesis imaging image processing

Hypergravity Alters the Susceptibility of Cells to Anoxia-Reoxygenation Injury

Gravity is a physical force, much like shear stress or mechanical stretch, and should affect organ and cellular function. Researchers have shown that gravity plays a role in ventilation and blood flow distribution, gas exchange, alveolar size and mechanical stresses within the lung. Short exposure to microgravity produced marked alterations in lung blood flow and ventilation distribution while hypergravity exaggerated the regional differences in lung structure and function resulting in reduced ventilation at the base and no ventilation of the upper half of the lung. Microgravity also decreased metabolic activity in cardiac cells, WI-38 embryonic lung cells, and human lymphocytes. Rats, in the tail-suspended head-down tilt model, experienced transient loss of lung water, contrary to an expected increase due to pooling of blood in the pulmonary vasculature. Hypergravity has also been found to increase the proliferation of several different cell lines (e.g., chick embryo fibroblasts) while decreasing cell motility and slowing liver regeneration following partial hepatectomy. These studies show that changes in the gravity environment will affect several aspects of organ and cellular function and produce major change in blood flow and tissue/organ perfusion. However, these past studies have not addressed whether ischemia-reperfusion injury will be exacerbated or ameliorated by changes in the gravity environment, e.g., space flight. Currently, nothing is known about how gravity will affect the susceptibility of different lung and vascular cells to this type of injury. We conducted studies that addressed the following question: Does the susceptibility of lung fibroblasts, vascular smooth muscle, and endothelial cells to anoxia/reoxygenation injury change following exposure to hypergravity conditions?

McCloud, Henry

Intelligent Entity Behavior Within Synthetic Environments

This paper describes some elements in the development of realistic performance and behavior in the synthetic entities (players) which support Modeling and Simulation (M&S) applications, particularly military training. Modern human-in-the-loop (virtual) training systems incorporate sophisticated synthetic environments, which provide: 1. The operational environment, including, for example, terrain databases; 2. Physical entity parameters which define performance in engineered systems, such as aircraft aerodynamics; 3. Platform/system characteristics such as acoustic, IR and radar signatures; 4. Behavioral entity parameters which define interactive performance, including knowledge/reasoning about terrain, tactics; and, 5. Doctrine, which combines knowledge and tactics into behavior rule sets. The resolution and fidelity of these model/database elements can vary substantially, but as synthetic environments are designed to be compose able, attributes may easily be added (e.g., adding a new radar to an aircraft) or enhanced (e.g. Amending or replacing missile seeker head/ Electronic Counter Measures (ECM) models to improve the realism of their interaction). To a human in the loop with synthetic entities, their observed veridicality is assessed via engagement responses (e.g. effect of countermeasures upon a closing missile), as seen on systems displays, and visual (image) behavior. The realism of visual models in a simulation (level of detail as well as motion fidelity) remains a challenge in realistic articulation of elements such as vehicle antennae and turrets, or, with human figures; posture, joint articulation, response to uneven ground. Currently the adequacy of visual representation is more dependant upon the quality and resolution of the physical models driving those entities than graphics processing power per Se. Synthetic entities in M&S applications traditionally have represented engineered systems (e.g. aircraft) with human-in-the-loop performance characteristics (e.g. visual acuity) included in the system behavioral specification. As well, performance affecting human parameters such as experience level, fatigue and stress are coming into wider use (via AI approaches) to incorporate more uncertainty as to response type as well as performance (e.g. Where an opposing entity might go and what it might do, as well as how well it might perform).

Kruk, R. V.

Scripting human animations in a virtual environment

The current deficiencies of virtual environment (VE) are well known: annoying lag time in drawing the current view, drastically simplified environments to reduce that time lag, low resolution and narrow field of view. Animation scripting is an application of VE technology which can be carried out successfully despite these deficiencies. The final product is a smoothly moving high resolution animation displaying detailed models. In this system, the user is represented by a human computer model with the same body proportions. Using magnetic tracking, the motions of the model's upper torso, head and arms are controlled by the user's movements (18 degrees of freedom). The model's lower torso and global position and orientation are controlled by a spaceball and keypad (12 degrees of freedom). Using this system human motion scripts can be extracted from the user's movements while immersed in a simplified virtual environment. Recorded data is used to define key frames; motion is interpolated between them and post processing adds a more detailed environment. The result is a considerable savings in time and a much more natural-looking movement of a human figure in a smooth and seamless animation.

Goldsby, Michael E.

Role of muscle pulleys in producing eye position-dependence in the angular vestibuloocular reflex: a model-based study

It is well established that the head and eye velocity axes do not always align during compensatory vestibular slow phases. It has been shown that the eye velocity axis systematically tilts away from the head velocity axis in a manner that is dependent on eye-in-head position. The mechanisms responsible for producing these axis tilts are unclear. In this model-based study, we aimed to determine whether muscle pulleys could be involved in bringing about these phenomena. The model presented incorporates semicircular canals, central vestibular pathways, and an ocular motor plant with pulleys. The pulleys were modeled so that they brought about a rotation of the torque axes of the extraocular muscles that was a fraction of the angle of eye deviation from primary position. The degree to which the pulleys rotated the torque axes was altered by means of a pulley coefficient. Model input was head velocity and initial eye position data from passive and active yaw head impulses with fixation at 0 degrees, 20 degrees up and 20 degrees down, obtained from a previous experiment. The optimal pulley coefficient required to fit the data was determined by calculating the mean square error between data and model predictions of torsional eye velocity. For active head impulses, the optimal pulley coefficient varied considerably between subjects. The median optimal pulley coefficient was found to be 0.5, the pulley coefficient required for producing saccades that perfectly obey Listing's law when using a two-dimensional saccadic pulse signal. The model predicted the direction of the axis tilts observed in response to passive head impulses from 50 ms after onset. During passive head impulses, the median optimal pulley coefficient was found to be 0.21, when roll gain was fixed at 0.7. The model did not accurately predict the alignment of the eye and head velocity axes that was observed early in the response to passive head impulses. We found that this alignment could be well predicted if the roll gain of the angular vestibuloocular reflex was modified during the initial period of the response, while pulley coefficient was maintained at 0.5. Hence a roll gain modification allows stabilization of the retinal image without requiring a change in the pulley effect. Our results therefore indicate that the eye position-dependent velocity axis tilts could arise due to the effects of the pulleys and that a roll gain modification in the central vestibular structures may be responsible for countering the pulley effect.

NASA Discipline Neuroscience

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post-­‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi-­‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two-­‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x-­‐acceleration peak response correlated with the human response at 8 and 10-­‐G 100 ms but not 10-­‐G 70 ms. The phase lagged the human response. Head z-­‐acceleration was not correlated. Chest x-­‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x-­‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x-­‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x-­‐acceleration was not well correlated. Head and chest z-­‐acceleration was in phase but had a higher peak response. Chest z-­‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z-­‐displacement but the THOR was in phase and was comparable to the mean peak response. Head x-­‐ and z-­‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, Nate

Catecholaminergic effects of prolonged head-down bed rest

Prolonged head-down bed rest (HDBR) provides a model for examining responses to chronic weightlessness in humans. Eight healthy volunteers underwent HDBR for 2 wk. Antecubital venous blood was sampled for plasma levels of catechols [norepinephrine (NE), epinephrine, dopamine, dihydroxyphenylalanine, dihydroxyphenylglycol, and dihydroxyphenylacetic acid] after supine rest on a control (C) day and after 4 h and 7 and 14 days of HDBR. Urine was collected after 2 h of supine rest during day C, 2 h before HDBR, and during the intervals 1-4, 4-24, 144-168 (day 7), and 312-336 h (day 14) of HDBR. All subjects had decreased plasma and blood volumes (mean 16%), atriopeptin levels (31%), and peripheral venous pressure (26%) after HDBR. NE excretion on day 14 of HDBR was decreased by 35% from that on day C, without further trends as HDBR continued, whereas plasma levels were only variably and nonsignificantly decreased. Excretion rates of dihydroxyphenylglycol and dihydroxyphenylalanine decreased slightly during HDBR; excretion rates of epinephrine, dopamine, and dihydroxyphenylacetic acid and plasma levels of catechols were unchanged. The results suggest that HDBR produces sustained inhibition of sympathoneural release, turnover, and synthesis of NE without affecting adrenomedullary secretion or renal dopamine production. Concurrent hypovolemia probably interferes with detection of sympathoinhibition by plasma levels of NE and other catechols in this setting. Sympathoinhibition, despite decreased blood volume, may help to explain orthostatic intolerance in astronauts returning from spaceflights.

Non-NASA Center

Renal Function of Rats in Response to 37 Days of Head-Down Tilt

Spaceflight induces changes in human renal function, suggesting similar changes may occur in rats. Since rats continue to be the prime mammalian model for study in space, the effects of chronic microgravity on rat renal function should be clarified. Acute studies in rats using the ground-based microgravity simulation model, head-down tilt (HDT), have shown increases in glomerular filtration rate (GFR), electrolyte excretion, and a diuresis. However, long term effects of HDT have not been studied extensively. This study was performed to elucidate rat renal function following long-term simulated microgravity. Chronic exposure to HDT will cause an increase in GFR and electrolyte excretion in rats, similar to acute exposures, and lead to a decrease in the fractional excretion of filtered electrolytes. Experimental animals (HDT, n=10) were tail-suspended for 37 days and renal function compared to ambulatory controls (AMB, n=10). On day 37 of HDT, GFR, osmolal clearance, and electrolyte excretion were decreased, while plasma osmolality and free water clearance were increased. Urine output remained similar between groups. The fractional excretion of the filtered electrolytes was unchanged except for a decrease in the percentage of filtered calcium excreted. Chronic exposure to HDT results in decreased GFR and electrolyte excretion, but the fractional excretion of filtered electrolytes remained primarily unaffected.

Wang, Tommy J.

[Dentists on Mars]

The oral health of astronauts, last studied in the mid- 1970s on Skylab, has not been a priority area of study for NASA due to the short length of shuttle stays. But with longer stays on the International Space Station, and planning for a trip to Mars, investigations into how spaceflight affects oral health are needed. The objective of this symposium is to introduce the dental research community to changes occurring in humans who go into space, and how these changes might impact oral health. Dr. Millie Hughes-Fulford, an astronaut-scientist, will review what happens to humans who go into space, and the difficulties of living, and carrying out experiments in space. She will then discuss her research on cell cultures of osteoblasts in space, and in hypergravity Dr. Gerald Sonnenfeld will review immunological changes that occur in spaceflight, and relate the observed decreases in various types of immunological responses to possible effects on oral immunological factors. Dr. Marian Lewis will discuss the effects of spaceflight on gene expression using results from her spaceflight experiments on various cell types. Dr. Jack van Loon, fiom the Dutch Experiment Support Center, will review what is known about bone loss in humans and rats and metatarsal cultures which go into space, and review ground based models (head down bedrest, and tail suspension) that simulate the unloading of spaceflight. Attendees will gain a knowledge of spaceflight research, and information on getting their own experiments in space. The symposium is supported by the NASA Office of Bioastronautics

Duke, P. J.

Orientation of human optokinetic nystagmus to gravity: a model-based approach

Optokinetic nystagmus (OKN) was induced by having subjects watch a moving display in a binocular, head-fixed apparatus. The display was composed of 3.3 degrees stripes moving at 35 degrees/s for 45 s. It subtended 88 degrees horizontally by 72 degrees vertically of the central visual field and could be oriented to rotate about axes that were upright or tilted 45 degrees or 90 degrees. The head was held upright or was tilted 45 degrees left or right on the body during stimulation. Head-horizontal (yaw axis) and head-vertical (pitch axis) components of OKN were recorded with electro-oculography (EOG). Slow phase velocity vectors were determined and compared with the axis of stimulation and the spatial vertical (gravity axis). With the head upright, the axis of eye rotation during yaw axis OKN was coincident with the stimulus axis and the spatial vertical. With the head tilted, a significant vertical component of eye velocity appeared during yaw axis stimulation. As a result the axis of eye rotation shifted from the stimulus axis toward the spatial vertical. Vertical components developed within 1-2 s of stimulus onset and persisted until the end of stimulation. In the six subjects there was a mean shift of the axis of eye rotation during yaw axis stimulation of approximately 18 degrees with the head tilted 45 degrees on the body. Oblique optokinetic stimulation with the head upright was associated with a mean shift of the axis of eye rotation toward the spatial vertical of 9.2 degrees. When the head was tilted and the same oblique stimulation was given, the axis of eye rotation rotated to the other side of the spatial vertical by 5.4 degrees. This counterrotation of the axis of eye rotation is similar to the "Muller (E) effect," in which the perception of the upright is counterrotated to the opposite side of the spatial vertical when subjects are tilted in darkness. The data were simulated by a model of OKN with a "direct" and "indirect" pathway. It was assumed that the direct visual pathway is oriented in a body, not a spatial frame of reference. Despite the short optokinetic after-nystagmus time constants, strong horizontal to vertical cross-coupling could be produced if the horizontal and vertical time constants were in proper ratio and there were no suppression of nystagmus in directions orthogonal to the stimulus direction. The model demonstrates that the spatial orientation of OKN can be achieved by restructuring the system matrix of velocity storage. We conclude that an important function of velocity storage is to orient slow-phase velocity toward the spatial vertical during movement in a terrestrial environment.

Non-NASA Center

Extracting heading and temporal range from optic flow: Human performance issues

Pilots are able to extract information about their vehicle motion and environmental structure from dynamic transformations in the out-the-window scene. In this presentation, we focus on the information in the optic flow which specifies vehicle heading and distance to objects in the environment, scaled to a temporal metric. In particular, we are concerned with modeling how the human operators extract the necessary information, and what factors impact their ability to utilize the critical information. In general, the psychophysical data suggest that the human visual system is fairly robust to degradations in the visual display, e.g., reduced contrast and resolution or restricted field of view. However, extraneous motion flow, i.e., introduced by sensor rotation, greatly compromises human performance. The implications of these models and data for enhanced/synthetic vision systems are discussed.

Kaiser, Mary K.

A model-based analysis of a display for helicopter landing approach

A control theoretic model of the human pilot was used to analyze a baseline electronic cockpit display in a helicopter landing approach task. The head down display was created on a stroke written cathode ray tube and the vehicle was a UH-1H helicopter. The landing approach task consisted of maintaining prescribed groundspeed and glideslope in the presence of random vertical and horizontal turbulence. The pilot model was also used to generate and evaluate display quickening laws designed to improve pilot vehicle performance. A simple fixed base simulation provided comparative tracking data.

Hess, R. A.

Feasibility Study of a Lunar Analog Bed Rest Model

The purpose of this study was to determine the feasibility of using a 9.5deg head-up tilt bed rest model to simulate the effects of the 1/6 g load to the human body that exists on the lunar surface. The lunar analog bed rest model utilized a modified hospital bed. The modifications included mounting the mattress on a sled that rolled on bearings to provide freedom of movement. The weight of the sled was off-loaded using a counterweight system to insure that 1/6 body weight was applied along the long axis (z-axis) of the body. Force was verified through use of a force plate mounted at the foot of the bed. A seating assembly was added to the bed to permit periods of sitting. Subjects alternated between standing and sitting positions throughout the day. A total of 35% of the day was spent in the standing position and 65% was spent sitting. In an effort to achieve physiologic fluid shifts expected for a 1/6 G environment, subjects wore compression stockings and performed unloaded foot and ankle exercises. Eight subjects (3 females and 5 males) participated in this study. Subjects spent 13 days in the pre-bed rest phase, 6 days in bed rest and 3 days post bed rest. Subjects consumed a standardized diet throughout the study. To determine feasibility, measures of subject comfort, force and plasma volume were collected. Subject comfort was assessed using a Likert scale. Subjects were asked to assess level of comfort (0-100) for 11 body regions and provide an overall rating. Results indicated minimal to no discomfort as most subjects reported scores of zero. Force measures were performed for each standing position and were validated against subject s calculated 1/6 body weight (r(sup 2) = 0.993). The carbon monoxide rebreathing technique was used to assess plasma volume during pre-bed rest and on the last day of bed rest. Plasma volume results indicated a significant decrease (p = 0.001) from pre to post bed rest values. Subjects lost on average 8.3% (sd = 6.1%) during the bed rest phase. Findings from this feasibility study indicated that 1) the lunar analog bed rest model was well tolerated by subjects; 2) a 1/6 load was accurately applied to the z-axis of the body; and 3) plasma volume losses could be achieved in a head-up tilt bed rest model. Future work to refine this model should include extending the duration of bed rest to mimic longer mission durations and a comprehensive assessment of the physiological responses to this bed rest analog.

Cromwell, Ronita L.

Perception of tilt (somatogravic illusion) in response to sustained linear acceleration during space flight

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural and head vertical (dorsoventral) linear accelerations of 0.5 g and 1 g during constant velocity rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear-out or right-ear-out (Gy centrifugation), or lay supine along the centrifuge arm with their head off-axis (Gz centrifugation). Pre-flight centrifugation, producing linear accelerations of 0.5 g and 1 g along the Gy (interaural) axis, induced illusions of roll-tilt of 20 degrees and 34 degrees for gravito-inertial acceleration (GIA) vector tilts of 27 degrees and 45 degrees , respectively. Pre-flight 0.5 g and 1 g Gz (head dorsoventral) centrifugation generated perceptions of backward pitch of 5 degrees and 15 degrees , respectively. In the absence of gravity during space flight, the same centrifugation generated a GIA that was equivalent to the centripetal acceleration and aligned with the Gy or Gz axes. Perception of tilt was underestimated relative to this new GIA orientation during early in-flight Gy centrifugation, but was close to the GIA after 16 days in orbit, when subjects reported that they felt as if they were 'lying on side'. During the course of the mission, inflight roll-tilt perception during Gy centrifugation increased from 45 degrees to 83 degrees at 1 g and from 42 degrees to 48 degrees at 0.5 g. Subjects felt 'upside-down' during in-flight Gz centrifugation from the first in-flight test session, which reflected the new GIA orientation along the head dorsoventral axis. The different levels of in-flight tilt perception during 0.5 g and 1 g Gy centrifugation suggests that other non-vestibular inputs, including an internal estimate of the body vertical and somatic sensation, were utilized in generating tilt perception. Interpretation of data by a weighted sum of body vertical and somatic vectors, with an estimate of the GIA from the otoliths, suggests that perception weights the sense of the body vertical more heavily early in-flight, that this weighting falls during adaptation to microgravity, and that the decreased reliance on the body vertical persists early post-flight, generating an exaggerated sense of tilt. Since graviceptors respond to linear acceleration and not to head tilt in orbit, it has been proposed that adaptation to weightlessness entails reinterpretation of otolith activity, causing tilt to be perceived as translation. Since linear acceleration during in-flight centrifugation was always perceived as tilt, not translation, the findings do not support this hypothesis.

STS-90 Shuttle Project