Search NASA⌕ Search

SEARCH · Search NASA

Results for “Human-System Interface Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ontology to guide scenario design to evaluate new technologies for control room modernization - 127

Modernization of nuclear power plants (NPPs) are introducing new human-system interface (HSI) technology that may have unanticipated impact on control room operations. Introduction of HSI thus requires careful evaluation and integrated system validation involving human-in-the-loop experiments with high-fidelity simulation and realistic scenarios. To support the technology evaluation in modernization of NPPs, this paper reports our research on constructing an 'scenario development ontology' for the nuclear industry. We conducted a literature review to produce a preliminary flow chart of the scenario development process and verified the flow chart through interviews with ten domain professionals. The interviews confirmed the key steps in the process flow chart and provided a compendium of approximately 100 scenario attributes, which were divided according to their relevance to HSI evaluation. The next step will be to conduct additional interviews to expand and generalize the ontology that can facilitate vendor and industry evaluation of current and future control room modernization projects. This ontology is particularly intended to facilitate vendor and industry evaluation of current and future control room modernization projects. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EXPLORING THE USE OF COGNITIVE MODELS FOR NUCLEAR POWER PLANT HUMAN-SYSTEM INTERFACE EVALUATION

Much of the United States commercial nuclear power plant fleet is approaching the end of their operating licenses. To extend the life of these plants, advanced human-system interface (HSI) technologies are being researched to address aging and reliability concerns with the existing legacy instrumentation and controls. Human factors engineering (HFE) has a crucial role in ensuring these technologies are designed in a way that does not introduce new failure modes and promote optimal human-system performance. An important focus of HFE in NPP modernization is the early involvement to inform the design of the HSI. Here, traditional formative evaluations are done to collect design feedback. While these evaluations are absolutely useful, they are limited in providing convincing quantitative data for efficiency of use. This paper discusses the use of cognitive models to provide such quantitative data early in the HSI design process. A comparison of three open-source and readily accessible cognitive modeling tools are discussed.

99 GENERAL AND MISCELLANEOUS↗

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors↗

Exploring the Psychometrics of Common Post-Scenario Human Factors Questionnaires of Workload, Situation Awareness, and Perceived Difficulty

Abstract: The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program has the primary mission of sustaining operation of the existing commercial nuclear power plants (NPPs) through a multi-pathway approach in conducting research and development (R&D). In this effort, the role of human factors engineering (HFE) has been an integral in ensuring new digital upgrades that are part of the overall main control room modernization strategy for various U.S. NPPs optimize human-system performance and do not introduce new human failure modes. In this process, testing and evaluation of concept (i.e., prototype) human machine interfaces (HMIs) are done in operator-in-the-loop studies at various stages of the HFE modification process, such as during design and verification and validation (V&V) [1]. During these studies, licensed operators go through select scenarios using a testbed, such as a full-scale simulator or at a NPP’s training simulator, to identify potential usability issues and provide general design feedback regarding the new digital HMIs. Human-system performance is measured and evaluated through a range of objective and self-report measures that capture aspects of plant performance, task performance, workload, situation awareness, and anthropometric and ergonomic concerns [2]. The use of post-scenario questionnaires is an acceptable method for gathering measures of workload and situation awareness. To this end, the NASA-Task Load Index (TLX) [e.g., 3, 4, & 5] and Situation Awareness Rating Technique (SART) [e.g., 6 & 7] are common standardized questionnaires used for evaluating workload and situation awareness, respectively. When combined, these questionnaires consist of a total of 15 questions, each using a different rating scale. Debriefs are also done through interviews with operators to gather design insight after each scenario. Since operator- and training simulator-time is limited, a concern during this post-scenario period of operator-in-the-loop studies is the limited time available to run scenarios, administer post-scenario questionnaires, and debrief within the allotted simulator time. To address this potential problem, this paper explores the psychometric characteristics of NASA-TLX, SART, and a common one-question post-scenario usability questionnaire (i.e., the single ease question – SEQ [8]) in effort to inform future development of a condensed questionnaire that captures aspects of workload and situation awareness. This exploratory work uses data from four different operator-in-the-loop studies completed under prior LWRS operator-in-the-loop studies. Findings from this paper should support future development of a consolidated questionnaire that may be used in operator-in-the-loop studies, when time is compressed, that conforms to the HFE scientific and regulatory requirements set for NPP control room modernization.

99 GENERAL AND MISCELLANEOUS↗

Development of an Assessment Methodology That Enables the Nuclear Industry to Evaluate Adoption of Advanced Automation

Nuclear power has a crucial role in providing safe, reliable, and economical carbon-free electricity for today and the future. For continued operation, many of the existing United States nuclear power plants will begin the subsequent license renewal process for extending their operating license periods. As plants extend their expected operating lifetimes, there is a significant opportunity to modernize. These plants have a much stronger business case with these extended mission periods to modernize and significantly enhance their economic viability in current and future energy markets by implementing digital technologies that support innovation, efficiency gains, and business-model transformation. Ensuring continued safety and reliability is crucial. Transformative digital technologies—including automation—that fundamentally change the concept of operation for the nuclear power plant operating model requires a critical focus on the human and technology integration element. Further, the nuclear industry has historically been reluctant to modernize due to having a risk adverse culture and lack of clarity for a transformative new state vision (Joe & Remer, 2019; Thomas et al., 2020). Common barriers include (1) the perceived value and return on investment (ROI) of digital technology, (2) the perceived risk associated with licensing, regulatory, and cybersecurity, and (3) insufficient guidance for performing digital modifications to power generation systems. This work presents a methodology to address these barriers and support the industry in adopting advanced automation and digital technology through developing a transformative vision and implementation strategy that will address the human and technology integration element. This research leverages previous LWRS Program and industry results. It draws specifically on previous LWRS Program research in the areas of advanced alarm systems, computer-based procedures, model informed decision support, and advanced human-system interface displays (e.g., overviews and task-based). The modernization methodology can be used to guide transformative thinking when integrating a set of vendor-specific capabilities to support a new concept of operations and a utility’s end-state vision. The results of this research are organized into six major sections: - Section 1 introduces the need for supporting large-scale digital modifications that will renew the technology base for extended operating life beyond 60 years - Section 2 describes the challenges that the nuclear industry is enduring with modernizing. - Section 3 summarizes the primary standards and guidance. - Section 4 presents earlier work from the LWRS Program regarding the development of a transformative conceptual design for an advanced control room of a hybrid plants. - Section 5 presents a methodology that is designed at addressing the challenges in the industry today in achieving a transformative new state vision and concept of operations. - Conclusions and next steps of this research are provided in Section 6.

99 GENERAL AND MISCELLANEOUS↗

Lessons Learned from Performing a Human Factors Engineering Validation of an Upgraded Digital Control System in a Nuclear Power Plant Control Room

The United States' fleet of nuclear power plants (NPPs) have exceeded their original 40-year licenses and many are seeking license renewals to continue operations into the future. To support continued operation the Department of Energy's (DOE) Light Water Reactor Sustainability Program (LWRS) provides support for utilities to maintain and upgrade their power production capabilities. Control room modernization is one focus area, which aims to modernization the analog control rooms with digital controls and human-system interfaces (HSIs). The Turbine Control System (TCS) is a non-safety related system undergoing modernization efforts at multiple plants and utilities. Considerable human factors research efforts, comprised of expert reviews and operator in the loop studies were performed to develop human factors compliant and usable TCS. This report documents the final phase of the human factors engineering program used to design and validate the new digital TCS. According to the NUREG-0711 review guide, one of the last steps of human factors engineering program prior to implementation is human factors validation. This report details the method, results and conclusions from the human factors validation study of a collaborating utilities TCS slated to be implemented in one of their plants. One control room team consisting of two control room supervisors and two reactor operators participated in the validation. All team members had participated in the BNP TCS training program foregoing the TCS validation. Performance measures included task performance, situation awareness and workload, expert observation of any negative influences of human-system interface features on control room team performance, and interviews with the participating operators. Performance criteria were based on the performance scores and the topics identified by interviews and expert observations. The results showed that the crew using the new TCS clearly could achieve their overall objectives in the test scenarios with sufficient situation awareness. The new TCS compared to the old system provided clear improvements of the control room work regarding shell and chest warming and regarding valve and other system testing. However, a number of Human Engineering Discrepancies (HEDs) were identified. HEDs were prioritized (level 1, 2 or 3) according to potential safety, plant availability, operability or personnel performance consequences. Since no priority 1 HEDs were identified there is no HFE reason not to continue implementation of the TCS. The TCS upgrade is acceptable if the Priority 2 HEDs are resolved and dispositioned in a satisfactory way. Priority 3 HEDs should be noted and considered for future modifications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

99 GENERAL AND MISCELLANEOUS↗

Application of Eye Tracking for Measurement and Evaluation in Human Factors Studies in Control Room Modernization

An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. Furthermore, as part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

99 GENERAL AND MISCELLANEOUS↗

Application of eye tracking for measurement and evaluation in human factors studies in control room modernization - 309

An important element of human factors engineering (HFE) pertains to measurement and evaluation (M and E). The role of HFE-M and E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M and E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M and E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Comparison of Three Types of Computer-Based Procedures: An Experiment Using the Rancor Microworld Simulator

The nuclear power industry has historically used paper-based procedures, but a shift towards computer-based procedures (CBPs) has the potential to reduce human errors, alleviate mental workload, and improve work performance. Twenty-seven participants were randomly assigned to one of three CBP types using the Rancor Microworld Simulator, and each performed two different types of operational scenarios (startup and loss of feedwater). The three CBP types varied in levels of digitalization. It was hypothesized that there would be less favorable impressions of the most basic procedures, and that these would demonstrate lower usability than types with greater digitalization. Overall, our predictions were partially supported with some interesting caveats, specifically with some performance benefits for CBPs that provided indicators but not embedded controls. We discuss our findings in terms of optimal levels of digitalization/automation within nuclear operations and suggest pathways for future directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analog, Digital, or Enhanced Human-System Interfaces? Results of an Operator-in-the-Loop Study on Main Control Room Modernization for a Nuclear Power Plant

The second Operator Study of System Overviews (OSSO-2) was conducted with a three-person reactor operator crew in the Human Systems Simulation Laboratory (HSSL) at Idaho National Laboratory (INL) in August, 2017. The study supported control room modernization at a nuclear power plant and featured a benchmark comparison of three variants of a turbine control system (TCS): the existing analog TCS, a proposed standalone digital TCS with two displays, and the digital TCS with the addition of a third display consisting of a system overview screen. TCS prototypes were developed at INL to allow evaluation of operator performance and preferences during realistic turbine scenarios in the full-scope simulator. The study revealed that completion of turbine startup was several minutes faster with the digital TCS variants than with the conventional analog TCS. Eye tracking scan paths were more widely distributed in the overview vs. standalone TCS condition, suggesting the overview screen was cueing reactor operators to verify values across the boards. There was no significant difference in workload or situation awareness across the three interfaces. Reviewing key plant parameters showed smoother transitions during load following for the digital vs. analog TCS. Despite some performance advantages for the digital TCS variants, operators preferred the existing analog TCS. Open-ended responses suggested this finding may be more an artifact of familiarity than a reflection of dissatisfaction with the new TCS. OSSO-2 provides compelling evidence that the new digital TCS was used successfully by the operators without extensive training of rewriting of the operating procedures, suggesting high usability for the digital TCS design. Further advantages were realized through the addition of the system overview screen to provide crews with at-a-glance indicators of key turbine parameters.

99 GENERAL AND MISCELLANEOUS↗

Human-System Interface Style Guide for ACORN Digital Control System

The purpose of this style guide is to assist developers in designing effective and consistent-looking user interfaces for accelerator control rooms. A similar purpose is to help developers avoid the creation of user interfaces that needlessly stray from the accepted standard set forth in this document. This way, all interfaces combined will look congruous. This is especially beneficial for development that spans multiple years by many different contributors. This document is intended as a ready reference source for all user interface design for the Fermilab accelerator complex.

43 PARTICLE ACCELERATORS↗

Human Factors and Modeling Methods in the Development of Control Room Modernization Concepts

nuclear power plants. Although the nuclear industry has made steady improvement in outage optimization, each day of a refueling outage still represents an opportunity to save millions of dollars and each day an outage extends past its planned end date represents millions of dollars that may have been spent unnecessarily. Reducing planned outage duration or preventing outage extensions requires careful management of the outage schedule as well as constant oversight and monitoring of work completion during the outage execution. During a typical outage, there are typically more than 10,000 activities on the schedule that, if not managed efficiently, may cause expensive outage delays. Management of outages currently relies largely on paper-based resources and general-purpose office software. A typical tool currently used to monitor work performance is a burn-down curve, where total remaining activities are plotted against the baseline schedule to track bulk work completion progress. While these tools are useful, there is still considerable uncertainty during a typical outage that bulk work progress is adequate and therefore a lot of management time is spent analyzing the situation on a daily basis. This paper describes recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the scientific principles that informed the development of the visualizations. To test the utility of advanced visual outage information presentation, an outage management dashboard software application was created as part of the Department of Energy’s Advanced Outage Control Center project. This dashboard is intended to present all the critical information an outage manager would need to understand the current status of a refueling outage. The dashboard presents the critical path, bulk work performance, key performance indicators, outage milestones and metrics relating current performance to historical performance. Additionally, the dashboard includes data analysis tools to allow outage managers to drill down into the underlying data to understand the drivers of the indicators.

99 GENERAL AND MISCELLANEOUS↗

A Human Factors Evaluation of an Advanced Human System Interface for the Generic Pressurized Water Reactor Simulator

Researchers at Idaho National Laboratory (INL), funded by the United States (U.S.) Department of Energy’s Light Water Reactor Sustainability (LWRS) Program, conducted a human factors evaluation of an Advanced Human System Interface (HSI) that colleagues at the Institute for Energy Technology developed for the generic Pressurized Water Reactor (gPWR) simulator. The gPWR simulator is based on an existing, currently operating, U.S. commercial nuclear power plant (NPP). Furthermore, INL has a relationship with this NPP that allows them to recruit operators to participate in their studies. INL also has a full-scope, full-scale simulator facility, called the Human Systems Simulation Laboratory, that hosts the gPWR simulator and allowed these researchers to compare human-system performance when operators used the existing/current gPWR HSI and the new Advanced HSI. As such, one goal of this work was to collect a baseline measure of human-system performance for the Advanced HSI and to identify areas to further improve the design of the Advanced HSI to optimize overall system usability. This paper summarizes the methodology used to perform this evaluation, which emphasized measuring key aspects of human-system performance and getting operator feedback on the design, aesthetics, and functionality of the Advanced HSI, and presents the key findings and insights gained.

99 GENERAL AND MISCELLANEOUS↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

Effects of adaptive automation on operator-system performance - 103

Adaptive automation (AA) is the dynamic, real-time change in the degree of automation in response to situational changes. AA systems are being developed in many industries, including for nuclear power plant applications. AA is a promising means of mitigating human performance issues that often arise in highly automated systems. The purpose of this Nuclear Regulatory Commission study was to characterize important AA design features, define the effects of AA on performance, examine the human factors engineering (HFE) guidance available to design and evaluate AA systems, and identify research and development needs. In general, we found that AA improves task performance and situation awareness (SA) while managing workload. Although the research is limited, AA also supports operator recognition of automation failure and recovery. Research on human-system interfaces has identified principles showing promise for supporting SA, including failure detection, and limiting workload. Research further suggests that AA systems are both more effective, and less disruptive and distracting, when they follow rules of interaction similar to those used by human crewmembers. Our general conclusion about the HFE guidance available to designers and reviewers is that it is limited and has not kept pace with automation technology. We discuss several research and development needs that will help support a better understanding of where and how AA should be used and support the development of more comprehensive guidance for AA safety reviews. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study on main control room and human-system interface of generation III in China - 313

This paper focuses on the study on Main Control Room (MCR) and Human-System Interface (HSI) of Generation III in China. An intelligent HSI has been developed to enhance the safety and availability of Nuclear Power Plant (NPP) by improving operational reliability. The key elements of the proposed HSI such as Advanced Alarm System, State Oriented Procedures (SOP), Large Display Panel (LDP), Computerized-base procedures..., that affects what information the operator sees or the system's response to a control input must be empirically evaluated to ensure that the new design does not compromise HSI effectiveness. Based on CPR1000's experience in China, this paper presents the approach used as well as the most relevant aspects of this kind of project for the next generation. This approach will be used in new Generation III nuclear power plant, and also used in modernizing I and C system in currently operative nuclear power plants, in addition to meeting safety requirements and the plant's operational requirements, to improve cost-effective plant and human performance and to reduce likelihood of human errors, to gain maximum benefit of the implemented technology and to increase the performance, resulting in improved plant safety, availability, reliability, and cost-effective operation. The proposed HSI has been validated and demonstrated using the CPR1000 simulator of National Key Laboratory. After sufficient validation, the characteristic design features of the proposed HSI will be reflected in the design of the main control room of the next generation reactors in China. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human factors and modeling methods in the development of control room modernization concepts - 315

Control room modernization is one of the most challenging and complex upgrade projects that a nuclear power plant can undertake. It can even have a bigger impact on operations than, for example, turbine replacement. The challenges of migrating an analog control system to a distributed control system are already well known and a number of nuclear utilities have embarked upon various levels of effort to upgrade some of the systems in the control room. When planning for control room upgrades, plants have to deal with a multitude of engineering and operational impacts. This will inevitably include several human factors considerations, including physical ergonomics of workstations, viewing angles, lighting, seating, new communication requirements, and new concepts of operation. In helping nuclear power utilities to deal with these challenges, the Idaho National Laboratory (INL) has developed human factors design and evaluation methods to be used in the development of an end-state control room concept and to manage the various phases of the upgrade life cycle. This included interactive sessions with operators in INL's Human System Simulation Laboratory, and three-dimensional modeling to visualize control board changes. To make the various upgrade phases as concrete and as visible as possible, the end-state concept includes a set of visual representations of the control room before and after various upgrade phases to provide the context and a framework within which to consider the various options in the upgrade. This includes the various control systems, human-system interfaces to be replaced, and possible changes to operator workstations. This paper describes how this framework helps to ensure an integrated and cohesive outcome that is consistent with human factors engineering principles and also provide substantial improvement in operator performance. The paper further describes the application of this integrated approach in the strategic modernization program at a nuclear power plant where legacy systems are upgraded to advanced digital technologies through a systematic process that links human factors principles to the systems engineering process. This approach results in an integrated control room architecture beyond what is possible for individual subsystem upgrades alone. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗