Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hybrid Renewable Energy Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PV-Diesel Hybrid SCADA Experiment Network Design

The essential features of an experimental network for renewable power system satellite based supervisory, control and data acquisition (SCADA) are communication links, controllers, diagnostic equipment and a hybrid power system. Required components for implementing the network consist of two satellite ground stations, to satellite modems, two 486 PCs, two telephone receivers, two telephone modems, two analog telephone lines, one digital telephone line, a hybrid-power system equipped with controller and a satellite spacecraft. In the technology verification experiment (TVE) conducted by Savannah State University and Florida Solar Energy Center, the renewable energy hybrid system is the Apex-1000 Mini-Hybrid which is equipped with NGC3188 for user interface and remote control and the NGC2010 for monitoring and basic control tasks. This power system is connected to a satellite modem via a smart interface, RS232. Commands are sent to the power system control unit through a control PC designed as PC1. PC1 is thus connected to a satellite model through RS232. A second PC, designated PC2, the diagnostic PC is connected to both satellite modems via separate analog telephone lines for checking modems'health. PC2 is also connected to PC1 via a telephone line. Due to the unavailability of a second ground station for the ACTS, one ground station is used to serve both the sending and receiving functions in this experiment. Signal is sent from the control PC to the Hybrid system at a frequency f(sub 1), different from f(sub 2), the signal from the hybrid system to the control PC. f(sub l) and f(sub 2) are sufficiently separated to avoid interference.

Kalu, Alex↗

Exploring the design space of PV-plus-battery system configurations under evolving grid conditions

In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.

14 SOLAR ENERGY↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗

Using Concentrating Solar Power to Create a Geological Thermal Energy Reservoir for Seasonal Storage and Flexible Power Plant Operation

Abstract We propose a hybrid renewable energy system—a geothermal energy storage system (GeoTES) with solar—to provide low-cost dispatchable power at various timescales from daily, to weekly, to seasonally. GeoTES with solar uses a concentrating solar power collector field to produce hot water that is injected into a sedimentary basin to create a synthetic geothermal resource. The stored geothermal heat can then be dispatched when required by the electrical grid. GeoTES is particularly valuable for a grid with a high penetration of non-flexible renewable technologies such as photovoltaic and wind power. In this work, a sophisticated hybrid model is developed to assess the technical and economic potential of GeoTES by combining IPSEpro, which is a power-cycle simulation tool, and SAM, an economic analysis tool by National Renewable Energy Laboratory (NREL). The analysis shows with proper initial charging period that the heat loss in storage is almost negligible and is a suitable technology for long-term energy storage. Various power-cycle options are evaluated, and the most suitable power cycle is selected for further study. Annual calculations of the GeoTES system indicate that a levelized cost of storage (LCOS) of 12.4 ¢/kWh e can be achieved for seasonal storage of 4000 h; this value is much lower than the existing long-term storage. The LCOS of GeoTES is insensitive to the storage duration above 8 h, unlike battery and molten-salt thermal storage systems. This result demonstrates that GeoTES can be a competitive seasonal storage technology in the future electricity market. The levelized cost of electricity of the GeoTES system is also carefully analyzed and can vary between 10.0 and 16.4 ¢/kWh e , depending on solar-collector prices.

25 ENERGY STORAGE↗

Renewable Energy and Storage Cybersecurity Research (RESCue) Pilot Final Report

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of distributed energy resources (DERs) and transmission-connected hybrid renewable energy systems against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. This publication the final report for the first year of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phenomenon Identification and Ranking Table Development for Future Application Figure-of-Merit Studies on Thermal Energy Storage Integrations with Light Water Reactors

There are no standard prioritization criteria for evaluating thermal energy storage (TES) options for use in integrated energy systems. A framework for proposing, analyzing, and presenting energy storage integration with power producers and users is presented along with a specific figure-of-merit (FOM) study based in this framework. This basis for evaluating storage technologies can provide a structure for the energy industry to analyze and prioritize energy storage in different applications and environments. The phenomena identification and ranking table (PIRT) presents a series of design questions specific to energy storage applications. The FOM study, built in this PIRT framework based on a nuclear-renewable hybrid energy system using TES to produce power and provide process energy for a secondary user, successfully identified specific technologies to use based on the project requirements. Expanding the library of projects using this framework will expand the deployable options for energy storage and increase its potential for energy security.

25 ENERGY STORAGE↗

Renewable Energy Guidance for Industry: Supplemental Document

This document is a supplement to the Better Plants’ Renewable Energy Guidance for Industry 2021. The purpose of this document is to further explain renewable energy technologies (i.e., solar energy, wind energy, biogas, waterpower, and geothermal) and to discuss briefly fuel cells and hybrid renewable energy systems.

09 BIOMASS FUELS↗

Renewable Thermal Hybridization Framework for Industrial Process Heat Applications

Solar industrial process heat (SIPH) technologies, such as concentrating solar power collectors, could economically replace the steam or heat needs at many industrial sites by providing high-temperature heat transfer fluids (HTFs) such as pressurized water, synthetic-oil, or direct steam. Renewable thermal energy systems (RTES) could be hybridized with different renewable options e.g., flat plate collectors with parabolic trough collectors, or combined with existing heat supplies (e.g., fossil fuels), to give options for targeted SIPH applications, industrial decarbonization and the reduction of fuel consumption. Hybrid solutions and thermal energy storage will be important for the dispatch of heat at optimal times needed by the demand side of the buildings and industrial applications. At present, there is no integrated modeling tool for hybrid RTES, and this paper highlights the development of a renewable thermal hybridization framework for IPH use that is built from existing tools like System Advisor Model. The long-term vision for the framework (through significant further research) is to develop a coupled hybrid energy generation and cost analysis tool, where the tool could help the user in determining the most suitable and cost-effective technologies for their applications. Ongoing work will look to add costs for RTES options and further refinement on the selection of suitable technologies. This future tool could calculate the levelized cost of heat of various RTES hybrid options, by taking the user's solar resource, fuel costs, industrial heat demand profile, available land, and other factors into account to determine the applicability into their process.

concentrating solar power↗

A comprehensive review of solar only and hybrid solar driven multigeneration systems: Classifications, benefits, design and prospective

Depending on the application and demands, different products can be generated utilizing multigeneration systems. To drive such systems, solar energy can be used as a primary energy source or in hybridization with other renewable or nonrenewable energy sources. Solar driven multigeneration systems are appealing due to the broad availability of solar energy and related technologies. Here, the objective of this study is to review, categorize and discuss different configurations, benefits, potentials, challenges, future research directions and market perspectives of solar energy-driven multigeneration systems, comprehensively. This study also reviews how solar energy systems can be used to hybridize systems for multigeneration purposes. Regardless of using fossil fuel backup sources, these systems are classified as (1) solar only-driven and (2) hybrid solar-driven, in which solar energy is used together with other renewable sources. Reviewing the literature demonstrates numerous ways to build solar energy-driven multigeneration systems by coupling a variety of different cycles and devices. Such systems offer multiple benefits such as enhancing the efficiency, reducing capital and operating costs and carbon dioxide emission. Hybridizing solar with other renewable energies enables continuous operation and dispatchability management. This review shows that for configuration selection and design, different thermodynamics, economic and environmental aspects should be considered. To advance the solar driven multigeneration systems development, further multidisciplinary research on different aspects of such systems is necessary. Particularly, investigations should focus on building different prototypes and on conducting experimental assessments. Also, new incentives and long-term purchase agreements for the products must be established.

14 SOLAR ENERGY↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Renewable and Energy Efficiency Technologies Overview

Renewable energy and energy efficiency technologies are growing rapidly and, with increased penetration, are increasingly impacting how the electricity grid operates. This presentation outlines a number of the technologies and describes the research, development, and deployment the National Renewable Energy Laboratory is partaking on them. It also provides data on the growth of renewable electricity generation technologies over the last decade and how their increasing generation impacts grid operations. It is intended for an audience familiar with energy technologies but who are not experts in either renewable energy or the electricity grid such as attendees at the virtual course nuclear-renewable integrated systems.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Renewable Thermal Hybridization Framework for Industrial Process Heat Applications

Renewable thermal energy systems (RTES) could be hybridized with different renewable options (e.g., flat plate collectors (FPCs) with parabolic collectors), or combined with existing heat supplies (e.g., fossil fuels), to give options for targeted solar IPH applications, industrial decarbonization and the reduction of fuel consumption. Buildings and industrial thermal energy applications require different temperature ranges, quantities, and rates of thermal energy, and as such require flexible, cost competitive solutions, able to provide heat over various temperature ranges. Hybrid solutions and thermal energy storage (TES) will be important for the dispatch of heat at optimal times needed by the demand side of the buildings and industrial applications. A variety of tools and platforms, such as the System Advisor Model (SAM), can provide hourly thermal yield simulations from single renewable energy (RE) technology options, including FPCs or CSP for solar IPH. We have investigated a variety of approaches to hybrid system modeling for RTES at different temperatures or combinations of technologies and developed an initial framework. The hybridization framework starts by creating a heat stream and raising the temperature of that heat stream by various combinations of RE technologies and other sources such as fossil fuels, new fuels or electric heating in multiple stages, with options for TES and/or waste heat recovery (WHR).

43 PARTICLE ACCELERATORS↗

Optimal Sizing and Dispatch of Solar Power with Storage

Designers of utility-scale solar plants with storage, seeking to maximize some aspect of plant performance, face multiple challenges. In many geographic locations, there is significant penetration of photovoltaic generation, which depresses energy prices during the hours of solar availability. An energy storage system affords the opportunity to dispatch during higher-priced time periods, but complicates plant design and dispatch decisions. Solar resource variability compounds these challenges, because determining optimal system sizes requires simultaneously considering how the plant will be operated under the imposed market and weather conditions. We develop an approach to analyze the economic performance of hybrid and single-technology solar power plants, which incorporates optimal dispatch, and considers the expected electricity market and weather conditions. We utilize the System Advisor Model software package to simulate the operation of multiple renewable generation and energy storage technologies, in conjunction with hourly-fidelity generation decisions determined by a revenue-maximizing, mixed-integer linear program. We show that, under our assumed market and weather conditions, the lifetime benefit-to-cost ratio can be improved by 6 to 19 percent, relative to a baseline design without optimizing, and that a concentrating solar power with thermal energy storage design produces significantly more energy per year, but is less profitable under our cost assumptions.

black-box optimization↗

Cold Weather Wind Turbines: A Joint NASA/NSF/DOE Effort in Technology Transfer and Commercialization

Renewable energy sources and their integration with other power sources to support remote communities is of interest for Mars applications as well as Earth communities. The National Science Foundation (NSF), NASA, and the Department of Energy (DOE) have been jointly supporting development of a 100 kW cold weather wind turbine through grants and SBIRs independently managed by each agency but coordinated by NASA. The NSF grant addressed issues associated with the South Pole application and a 3 kW direct drive unit is being tested there in anticipation of the 100 kW unit operation. The DOE-NREL contract focused on development of the 100 kW direct drive generator. The NASA SBIR focused on the development of the 100 kW direct drive wind turbine. The success of this effort has required coordination and team involvement of federal agencies and the industrial partners. Designs of the wind turbine and component performance testing results will be presented. Plans for field testing of wind turbines, based on this design, in village energy systems in Alaska and in energy production at the South Pole Station will be discussed. Also included will be a discussion of terrestrial and space use of hybrid energy systems, including renewable energy sources, such as the wind turbine, to support remote communities.

Flynn, Michael↗

Hybrid renewable pumped storage hydropower energy storage system

A pumped storage hydroelectric system may include a reservoir system including an upper reservoir system and a lower reservoir system. At least one of the upper reservoir system and the lower reservoir system may include a modular reservoir arrangement. A penstock may be coupled with the upper reservoir system. A pump/turbine may be coupled with the penstock and with the lower reservoir system. The pump/turbine may be configured to receive water flowing from the upper reservoir system to the lower reservoir system for generating electrical power, and to pump water from the lower reservoir system to the upper reservoir system for storing energy.

Medina, Hector Eduardo↗

Regional Hybrid Energy Systems Technoeconomic Analysis

The National Renewable Energy Laboratory (NREL) has been working with the Idaho National Laboratory (INL) and Argonne National Laboratory (ANL) to analyze the potential that hybridizing Xcel Energy's two nuclear power plants in Minnesota might have. The hybrid nuclear power plants would maximize sales of electricity when its price is high and reduce electricity sales to maximize hydrogen production when the price of electricity is low. This presentation summarizes the project's approach and status and communicates future direction.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDROGEN↗