Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrocarbon Recovery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Catalytic distillation water recovery subsystem

An integrated engineering breadboard subsystem for the recovery of potable water from untreated urine based on the vapor phase catalytic ammonia removal was designed, fabricated and tested. Unlike other evaporative methods, this process catalytically oxidizes ammonia and volatile hydrocarbons vaporizing with water to innocuous products; therefore, no pretreatment of urine is required. Since the subsystem is fabricated from commercially available components, its volume, weight and power requirements are not optimized; however, it is suitable for zero-g operation. The testing program consists of parametric tests, one month of daily tests and a continuous test of 168 hours duration. The recovered water is clear, odorless, low in ammonia and organic carbon, and requires only an adjustment of its pH to meet potable water standards. The obtained data indicate that the vapor phase catalytic ammonia removal process, if further developed, would also be competitive with other water recovery systems in weight, volume and power requirements.

Budininkas, P.↗

Two-stage reusable launch system utilizing a winged core vehicle and glideback boosters

A near-term technology launch system is described in which Space Shuttle main engines are used on a manned orbiter and also on twin strap-on unmanned boosters. The orbiter has a circular body and clipped delta wings. The twin strap-on boosters have a circular body and deployable oblique wings for a glideback recovery. The dry and gross weights of the system, capable of delivering 70klb of cargo to orbit, are compared with a similar system with hydrocarbon-fueled boosters and with the current Shuttle.

Macconochie, Ian O.↗

Hydrocarbon Burn Facility SWMU 007 Interim Groundwater Monitoring Report Kennedy Space Center, Florida

This Interim Groundwater Monitoring (IGWM) Report presents the findings of IGWM activities completed in November/December 2020 for the Volatile Organic Compound (VOC) Area of the Hydrocarbon Burn Facility (HBF) at Kennedy Space Center (KSC), Florida. HBF has been designated as Solid Waste Management Unit 007 under the KSC Resource Conservation and Recovery Act Corrective Action Program.

Jennifer Buel↗

Hydrocarbon Burn Facility SWMU 007 Interim Groundwater Monitoring Report Kennedy Space Center, Florida

This Interim Groundwater Monitoring (IGWM) Report presents the findings of IGWM activities completed in November 2021 along with an October 2021 direct push technology (DPT) investigation to confirm plume stability for the Volatile Organic Compound (VOC) Area of the Hydrocarbon Burn Facility (HBF) at Kennedy Space Center (KSC), Florida. HBF has been designated as Solid Waste Management Unit 007 under the KSC Resource Conservation and Recovery Act Corrective Action Program.

Jennifer Buel↗

Nano-crystalline porous tin oxide film for carbon monoxide sensing

A tin oxide sol is deposited on platinum electrodes (12) of a sensor (10). The sol is calcined at a temperature of 500 to 800.degree. C. to produce a thin film of tin oxide with a thickness of about 150 nm to 2 .mu. and having a nano-crystalline structure with good stability. The sensor rapidly detects reducing gases, such as carbon monoxide, or hydrocarbons and organic vapors. Sensors using films calcined at around 700.degree. C. have high carbon monoxide selectivity with a response time of around 4 minutes and a recovery time of 1 minute, and therefore provide good detection systems for detection of trace amounts of pollutants such as toxic and flammable gases in homes, industrial settings, and hospitals.

Liu, Chung-Chiun↗

Hydrocarbon Burn Facility SWMU 007 Interim Groundwater Monitoring Report Kennedy Space Center, Florida

This Interim Groundwater Monitoring (IGWM) Report presents the findings of IGWM activities completed in November 2022, and March through May 2023 including results from existing and newly installed groundwater monitoring wells and direct push technology (DPT) groundwater sampling in the Volatile Organic Compound (VOC) Area of the Hydrocarbon Burn Facility (HBF) at Kennedy Space Center (KSC), Florida. HBF has been designated as Solid Waste Management Unit (SWMU) 007 under the KSC Resource Conservation and Recovery Act Corrective Action Program.

Jennifer Buel↗

Four-man rated dual catalyst system for the recovery of water from urine

The catalytic system was integrated with a 4-man rated urine wick evaporator. During operation, urine vapor produced by the wick-evaporator was treated in the catalytic system to remove ammonia and volatile hydrocarbons, and water was recovered by condensation in a water cooled condenser. The system operated completely automatically and required no manual adjustments, except periodic supply of urine and removal of the recovered water. Although the system was designed for treating 0.325 kg urine per hour, this rate could be achieved only with a fresh wick, then gradually decreased as the wick became saturated with urine solids. The average urine treatment rates achieved during each of the three endurance tests were 0.137, 0.217, and 0.235 kg/hr. The quality of the recovered water meets drinking water standards, with the exception of a generally low pH.

Budininkas, P.↗

Hydrocarbon Burn Facility, SWMU 007 PER- and Polyfluoroalkyl Substances (PFAS) Assessment report Addendum Kennedy Space Center, Florida

This document discusses the Per-and Polyfluoroalkyl Substances (PFAS) assessment activities performed from December 2020 through November 2021 at the Hydrocarbon Burn Facility (HBF) located at Kennedy Space Center (KSC), Florida. The HBF site has been designated Solid Waste Management Unit (SWMU) 007 under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program. This PFAS Assessment Report Addendum (ARA) was prepared by Tetra Tech, Inc., for the National Aeronautics and Space Administration (NASA) under Indefinite Delivery Indefinite Quantity (IDIQ) Contract 80KSC019D0011-80KSC019F0077.

Jennifer M. Buel↗

Integrated Simulations of the Sabatier and Carbon Vapor Deposition Reactor to Understand Its Impacts to Operations and Performance

The carbon vapor deposition (CVD) reactor is a technology developed by Honeywell Aerospace to convert methane, at high temperatures, into hydrogen and solid carbon. This element is coupled with a Sabatier reactor to support a closed-loop environmental control and life support system with the aim of achieving nearly complete oxygen recovery (> 95%). Initial open-loop, brassboard CVD reactor tests and simulations have shown the CVD’s ability to achieve moderately high methane conversion and high hydrogen selectivity. However, in an integrated system, additional deficiencies are expected due to recycling of unreacted or extraneous species from the Sabatier reactor (e.g., carbon dioxide, hydrogen, water) and CVD reactor (e.g., hydrocarbons, methane, etc.). Sabatier and CVD reactor models were integrated and simulated to predict potential impacts to individual reactors’ and the overall system’s performance. The simulations showed that increasing the recycle of the CVD effluent hydrogen combined with decreasing the system inlet hydrogen flow rate (i.e., drawing a stoichiometric flow rate from an electrolyzer) can lead to an oxygen recovery of > 95%. However, system integration comes at a detriment to the individual reactors. The simulations show the initial conversion from the integrated system (Sabatier = 87% and CVD = 59%) to be lower than the standalone systems (Sabatier = 91% and CVD = 69%). Furthermore, transient simulations show substrate densification, leading to worsening methane conversion coupled with increasing acetylene production, which is commensurate with soot formation. Simulations predict a shortening of the maintenance interval (i.e., time until CVD methane conversion drops below 50%) in the integrated system, which would increase the consumable substrate mass. These analyses highlight the importance of long-duration, integrated tests to corroborate these findings as well as suggest potential modifications (e.g., intermediate gas separations) to improve performance.

Air Revitalization↗

Evaluation of cleaners for photovoltaic modules exposed in an outdoor environment

Power recovery of silicone encapsulated and glass covered photovoltaic modules, exposed for two years to a suburban environment, was measured after washing with a variety of cleaners including detergents, abrasive soap, and hydrocarbon solvents. Silicone encapsulated modules in operating environments may experience significant power losses or require extensive periodic cleaning. Glass front-faced modules in similar situations are much less affected. Organic hydrocarbon solvents or abrasives were found to be about five times more effective than mild detergents in cleaning encapsulated modules.

Knapp, W. D.↗

Recovery of aluminum from composite propellants

Aluminum was recovered from solid rocket propellant containing a small amount of oxidizer by depolymerizing and dissolving propellant binders (containing functional or hydrolyzable groups in a solution of sodium methoxide) in an alcohol solvent optionally containing an aliphatic or aromatic hydrocarbon co-solvent. The solution was filtered to recover substantially all the aluminum in active form.

Shaw, G. C.↗

Lifetimes and eigenstates in atmospheric chemistry

The time scales and mode of the atmosphere's response to chemical perturbations are defined by the eigenvalues and eigenvectors of the system. The eigenstates of a simplified one-box CH4-CO-OH system are analyzed. The longest time constant (smallest eigenvalue) always exceeds the lifetime defined by the steady-state loss frequency for CH4, the longest lived gas. Thus, the extent of a CH4 perturbation -- the methane response time -- is always longer than predicted by the steady-state lifetime and is independent of size of the perturbation in the linear limit. This lengthening of the atmospheric recovery time can be diagnosed by how close we are to a chemically unstable troposphere, i.e., how much OH production exceeds that minimum needed to oxidize just the global emissions of CH4, CO, and other hydrocarbons and species.

Prather, Michael J.↗

Simulation of Acetylene Adsorption Columns for Regenerative Life Support Systems

In oxygen recovery systems using Sabatier reactors, hydrogen (H 2 ) is the limiting factor in the Sabatier reaction. Aboard the International Space Station, electrolysis of water produces H 2 . However, additional H 2 can be provided by plasma pyrolysis of hydrocarbons, increasing the amount of H 2 available to the Sabatier reaction.

Regenerative Life Support↗

Kinetic Model Development of the Carbon Vapor Deposition Reactor to Predict Performance Versus Design

To enable complete closure of a Sabatier-based atmosphere revitalization system where oxygen recovery is predicated by carbon dioxide reduction to methane and water, there must be a means of recovering the hydrogen from the byproduct methane. Honeywell’s carbon vapor deposition (CVD) reactor is a potential technology that provides a thermochemical means by which methane decomposes at high temperatures (> 1,000 °C) into hydrogen, solid carbon, and a small percentage of hydrocarbons. This advanced methane pyrolysis reactor utilizes a carbon fiber substrate to capture and immobilize the solid pyrolytic carbon rather than allowing continuation toward undesirable soot. The CVD reactor is a highly dynamic system whose characteristic geometry changes while operating. The reactor model was developed to provide predictive performance assessment capabilities at different operating conditions, geometries, and configurations to aid in technology development. Modeling of the CVD reactor considered the multitude of simultaneous and interdependent physicochemical processes that are entailed, including: (1) the homogeneous gas-phase pyrolysis reactions, (2) the heterogeneous deposition reactions, and (3) the transport of gaseous species in the reactor domains. A 1-D CVD reactor model was developed based on a general packed-bed, axial-dispersion plug flow reactor model with a solid substrate balance to account for carbon deposition. The model includes 59 species and 243 reactions constituting the methane pyrolysis reaction network, carbon deposition, and interconversions of oxygenate species. The reactor model was compared to brassboard test data, where it was shown to be able to capture the pertinent physicochemical phenomena as evidenced by its agreement with short-duration run data (i.e., looking at different temperature and flow rate conditions), as well as trend agreement with the brassboard reactor’s long-duration test data. Recommendations are provided on further model development steps as well as its use cases.

Air Revitalization↗

Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-100 at the Conclusion of 6A

The toxicological assessment of air samples returned at the end of the STS-100 (6A) flight to the ISS is reported. ISS air samples were taken in March and April 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. An unplanned "first-entry" sample of the MPLM2 (multipurpose logistics module) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Endeavour using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contribution). Because of the Freon 218 (octafluoropropane, OFP) leak, its contribution to the NMVOC is indicated in brackets. When comparing the NMVOC values with the 25 mg/cubic m guideline, the OFP contributions should be subtracted. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample.

James, John T.↗

The Non-Destructive Separation of Diverse Astrobiologically Relevant Organic Molecules By Customizable Capillary Zone Electrophoresis and Monolithic Capillary Electrochromatography

The in situ detection of organic molecules in space is key to understanding the variety and the distribution of the building blocks of life, and possibly the detection of extraterrestrial life itself. Gas chromatography mass spectrometry (GC-MS) has been the most sensitive analytical instrument for organic analyses in flight, and was used on missions from NASA’s Viking, Phoenix, Curiosity missions to ESA’s Rosetta space probe. While pyrolysis GC-MS revealed the first organics on Mars, this step alters or degrades certain fragile molecules that are excellent biosignatures including polypeptides, oligonucleotides and polysaccharides, rendering the intact precursors undetectable. We have identified a solution tailored to the detection of biopolymers and other biomarkers by the use of liquid-based capillary electrophoresis and electrochromatography. In this study, we show that a capillary electrochromatography (CEC) approach using monolithic stationary phases with tailor-made surface chemistry can separate and identify various polycyclic aromatic hydrocarbons (PAHs), nucleobases and aromatic acids that could be formed under astrophysically relevant conditions. In order to simulate flyby organic sample capture, we conducted hypervelocity impact experiments which consisted of accelerating peptide-soaked montmorillonite particles to a speed of 5.6 km/sec, and capturing them in an amorphous silica aerogel of 10 and 30 mg/cc bulk density. Bulk peptide extraction from aerogel followed by capillary zone electrophoresis led to the detection of only two stereoisomeric peptide peaks. The recovery rates of each step of the extraction procedure after the hypervelocity impact suggest that major peptide loss occurred during the impact. Our study provides initial exploration of feasibility of this approach for capturing intact peptides, and subsequently detecting candidate biomolecules during flight missions that would be missed by GC-MS alone. As the monolith-based electrochromatography technology could be customized to detect specific classes of compounds as well as miniaturized, these results demonstrate the potential of the instrumentation for future astrobiology-related spaceflight missions.

Flyby sample return↗

Sustainable Resource Recovery from Trash, Waste, and Overboard Venting

Space travel and planetary missions for long-endurance human presence require Environmental Control and Life Support (ECLS) loop-closure. The air and water resource loops are generally closed with their processes having been established through extensive development, testing, and long-term use on International Space Station. Closure of the air and water loops have enabled oxygen and hydrogen sustainability. Carbon sustainability has yet to be addressed. Waste and trash, which also contains hydrogen and oxygen and abundant carbon have not been developed to the extent air and water have. Waste and trash have generally been dealt with in terms of simple safening, storage, and disposal. In externally disposing of waste, which includes C1 and C2 hydrocarbon gases, lost resources not only increase mission cost they can result in space and planetary pollution that can lead to unfavorable public opinion. With all this in mind, we explore the idea of carbon sustainability within closed-cycle waste, trash, and C1/C2 reprocessing. Starting from the current ECLS System roadmap, we identify resources that are not yet captured in closed-cycle processes but are lost when crossing the thermodynamic boundaries of an open system. Such pseudo-resources are trash, waste, and the gaseous carbon products of carbon dioxide reduction. We then consider different means and processes for minimizing pseudo-resource loss so as to “close the carbon loop.” There are cases in which pseudo-resources need to be externally discarded, such as reducing spacecraft acceleration mass. In this case we examine various processes that can be beneficial to missions even when these pseudo-resources are lost. An example would be the conversion of waste into propellant, which can produce thrust while at the same time reducing mass for transit acceleration (and ultimately propellant mass at launch), in which case we propose a means for evaluating the value of converting waste into propellant for different propulsion systems.

waste↗

Methane Hydrates: More Than a Viable Aviation Fuel Feedstock Option

Demand for hydrocarbon fuels is steadily increasing, and greenhouse gas emissions continue to rise unabated with the energy demand. Alternate fuels will be coming on line to meet that demand. This report examines the recovering of methane from methane hydrates for fuel to meet this demand rather than permitting its natural release into the environment, which will be detrimental to the planet. Some background on the nature, vast sizes, and stability of sedimentary and permafrost formations of hydrates are discussed. A few examples of the severe problems associated with methane recovery from these hydrates are presented along with the potential impact on the environment and coastal waters. Future availability of methane from hydrates may become an attractive option for aviation fueling, and so future aircraft design associated with methane fueling is considered.