Search NASA⌕ Search

SEARCH · Search NASA

Results for “ICA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Non-isothermal creep aging behaviors of an Al-Zn-Mg-Cu alloy

Highlights: • A novel non-isothermal creep aging (NICA) process is proposed to improve sheet metal forming efficiency. • Appropriate heating-cooling rate is conducive to obtain desired creep deformation and material properties. • The time consumption in optimized NICA process is about half of that in conventional creep aging process. • In NICA, the precipitates formed in heating will be dissolved nearby the peak temperature and re-precipitated in cooling. - Abstract: To shorten production period and reduce manufacturing cost of high strength aluminum alloy integral panel components, a novel non-isothermal creep age forming (CAF) technology was developed. Taking an Al-Zn-Mg-Cu alloy as the case material, the non-isothermal creep aging (NICA) behavior and the conventional isothermal creep aging (ICA) behavior were comparatively investigated. The corresponding creep deformations, material performance variations and precipitate microstructure evolutions were studied by creep aging tests, mechanical property and corrosion resistance tests, and transmission electron microscope (TEM) and scanning electron microscope (SEM) characterizations. Unlike the ICA which contains short heating and cooling stages and long holding stage, the NICA only has heating and cooling stages, viz., the alloy is heated slowly and the cooling stage begins immediately when reaching the peak temperature. In the NICA process, the precipitates nucleate and grow up in the first half of heating stage, resulting in the reduction of creep rate and enhancement of mechanical strength. The coarsening of precipitates occurs in the second half of heating stage, elevating the creep rate and significantly improving the corrosion resistance. Nearby the peak temperature, the primary precipitates partially dissolve, and the creep rate, mechanical strength and corrosion resistance decrease. Distinctive from the ICA process, a secondary precipitation phenomenon takes place in the cooling stage of NICA, leading to the recovery of high mechanical strength. The higher heating-cooling rate (1 °C/min) is not beneficial to accumulating creep deformation in the shorter creep aging period, while the lower one (0.25 °C/min) causes the loss of mechanical strength due to the excessive dissolution of precipitates. The moderate heating-cooling rate (0.5 °C/min) can lead to larger creep deformation, better mechanical properties and more satisfactory corrosion resistances in the NICA treated alloy, reaching 87.0% of creep strain, 105.7% of yield strength and 97.9% of electric conductivity in the ICA treated alloy. It is worth noting that the time consumption of the optimal NICA process is only 52.9% of the ICA process.

36 MATERIALS SCIENCE↗

A BLIND METHOD TO DETREND INSTRUMENTAL SYSTEMATICS IN EXOPLANETARY LIGHT CURVES

The study of the atmospheres of transiting exoplanets requires a photometric precision, and repeatability, of one part in ∼10{sup 4}. This is beyond the original calibration plans of current observatories, hence the necessity to disentangle the instrumental systematics from the astrophysical signals in raw data sets. Most methods used in the literature are based on an approximate instrument model. The choice of parameters of the model and their functional forms can sometimes be subjective, causing controversies in the literature. Recently, Morello et al. (2014, 2015) have developed a non-parametric detrending method that gave coherent and repeatable results when applied to Spitzer/IRAC data sets that were debated in the literature. Said method is based on independent component analysis (ICA) of individual pixel time-series, hereafter “pixel-ICA”. The main purpose of this paper is to investigate the limits and advantages of pixel-ICA on a series of simulated data sets with different instrument properties, and a range of jitter timescales and shapes, non-stationarity, sudden change points, etc. The performances of pixel-ICA are compared against the ones of other methods, in particular polynomial centroid division, and pixel-level decorrelation method. We find that in simulated cases pixel-ICA performs as well or better than other methods, and it also guarantees a higher degree of objectivity, because of its purely statistical foundation with no prior information on the instrument systematics. The results of this paper, together with previous analyses of Spitzer/IRAC data sets, suggest that photometric precision and repeatability of one part in 10{sup 4} can be achieved with current infrared space instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning analysis of RB-TnSeq fitness data predicts functional gene modules in Pseudomonas putida KT2440

ABSTRACT There is growing interest in engineering Pseudomonas putida KT2440 as a microbial chassis for the conversion of renewable and waste-based feedstocks, and metabolic engineering of P. putida relies on the understanding of the functional relationships between genes. In this work, independent component analysis (ICA) was applied to a compendium of existing fitness data from randomly barcoded transposon insertion sequencing (RB-TnSeq) of P. putida KT2440 grown in 179 unique experimental conditions. ICA identified 84 independent groups of genes, which we call fModules (“functional modules”), where gene members displayed shared functional influence in a specific cellular process. This machine learning-based approach both successfully recapitulated previously characterized functional relationships and established hitherto unknown associations between genes. Selected gene members from fModules for hydroxycinnamate metabolism and stress resistance, acetyl coenzyme A assimilation, and nitrogen metabolism were validated with engineered mutants of P. putida . Additionally, functional gene clusters from ICA of RB-TnSeq data sets were compared with regulatory gene clusters from prior ICA of RNAseq data sets to draw connections between gene regulation and function. Because ICA profiles the functional role of several distinct gene networks simultaneously, it can reduce the time required to annotate gene function relative to manual curation of RB-TnSeq data sets. IMPORTANCE This study demonstrates a rapid, automated approach for elucidating functional modules within complex genetic networks. While Pseudomonas putida randomly barcoded transposon insertion sequencing data were used as a proof of concept, this approach is applicable to any organism with existing functional genomics data sets and may serve as a useful tool for many valuable applications, such as guiding metabolic engineering efforts in other microbes or understanding functional relationships between virulence-associated genes in pathogenic microbes. Furthermore, this work demonstrates that comparison of data obtained from independent component analysis of transcriptomics and gene fitness datasets can elucidate regulatory-functional relationships between genes, which may have utility in a variety of applications, such as metabolic modeling, strain engineering, or identification of antimicrobial drug targets.

09 BIOMASS FUELS↗

REPEATABILITY OF SPITZER/IRAC EXOPLANETARY ECLIPSES WITH INDEPENDENT COMPONENT ANALYSIS

The research of effective and reliable detrending methods for Spitzer data is of paramount importance for the characterization of exoplanetary atmospheres. To date, the totality of exoplanetary observations in the mid- and far-infrared, at wavelengths >3 μm, have been taken with Spitzer. In some cases, in past years, repeated observations and multiple reanalyses of the same data sets led to discrepant results, raising questions about the accuracy and reproducibility of such measurements. Morello et al. (2014, 2015) proposed a blind-source separation method based on the Independent Component Analysis of pixel time series (pixel-ICA) to analyze InfraRed Array Camera (IRAC) data, obtaining coherent results when applied to repeated transit observations previously debated in the literature. Here we introduce a variant to the pixel-ICA through the use of wavelet transform, wavelet pixel-ICA, which extends its applicability to low-signal-to-noise-ratio cases. We describe the method and discuss the results obtained over 12 eclipses of the exoplanet XO3b observed during the “Warm Spitzer” era in the 4.5 μm band. The final results are reported, in part, also in Ingalls et al. (2016), together with results obtained with other detrending methods, and over 10 synthetic eclipses that were analyzed for the “IRAC Data Challenge 2015.” Our results are consistent within 1σ with the ones reported in Wong et al. (2014) and with most of the results reported in Ingalls et al. (2016), which appeared on arXiv while this paper was under review. Based on many statistical tests discussed in Ingalls et al. (2016), the wavelet pixel-ICA method performs as well as or better than other state-of-art methods recently developed by other teams to analyze Spitzer/IRAC data, and, in particular, it appears to be the most repeatable and the most reliable, while reaching the photon noise limit, at least for the particular data set analyzed. Another strength of the ICA approach is its highest objectivity, as it does not use prior information about the instrument systematics, making it a promising method to analyze data from other observatories. The self-consistency of individual measurements of eclipse depth and phase curve slope over a span of more than three years proves the stability of Warm Spitzer/IRAC photometry within the error bars, at the level of 1 part in 10{sup 4} in stellar flux.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis and visualization of single-trial event-related potentials

In this study, a linear decomposition technique, independent component analysis (ICA), is applied to single-trial multichannel EEG data from event-related potential (ERP) experiments. Spatial filters derived by ICA blindly separate the input data into a sum of temporally independent and spatially fixed components arising from distinct or overlapping brain or extra-brain sources. Both the data and their decomposition are displayed using a new visualization tool, the "ERP image," that can clearly characterize single-trial variations in the amplitudes and latencies of evoked responses, particularly when sorted by a relevant behavioral or physiological variable. These tools were used to analyze data from a visual selective attention experiment on 28 control subjects plus 22 neurological patients whose EEG records were heavily contaminated with blink and other eye-movement artifacts. Results show that ICA can separate artifactual, stimulus-locked, response-locked, and non-event-related background EEG activities into separate components, a taxonomy not obtained from conventional signal averaging approaches. This method allows: (1) removal of pervasive artifacts of all types from single-trial EEG records, (2) identification and segregation of stimulus- and response-locked EEG components, (3) examination of differences in single-trial responses, and (4) separation of temporally distinct but spatially overlapping EEG oscillatory activities with distinct relationships to task events. The proposed methods also allow the interaction between ERPs and the ongoing EEG to be investigated directly. We studied the between-subject component stability of ICA decomposition of single-trial EEG epochs by clustering components with similar scalp maps and activation power spectra. Components accounting for blinks, eye movements, temporal muscle activity, event-related potentials, and event-modulated alpha activities were largely replicated across subjects. Applying ICA and ERP image visualization to the analysis of sets of single trials from event-related EEG (or MEG) experiments can increase the information available from ERP (or ERF) data. Copyright 2001 Wiley-Liss, Inc.

Non-NASA Center↗

An Efficient and Accurate Algorithm for Computing Grid-Averaged Solar Fluxes for Horizontally Inhomogeneous Clouds

A computationally efficient method is presented to account for the horizontal cloud inhomogeneity by using a radiatively equivalent plane parallel homogeneous (PPH) cloud. The algorithm can accurately match the calculations of the reference (rPPH) independent column approximation (ICA) results, but use only the same computational time required for a single plane parallel computation. The effective optical depth of this synthetic sPPH cloud is derived by exactly matching the direct transmission to that of the inhomogeneous ICA cloud. The ffective9 scattering asymmetry factor is found from a pre-calculated albedo inverse look-up-table that is allowed to vary over the range from -1.0 to 1.0. In the special cases of conservative scattering and total absorption, the synthetic method is exactly equivalent to the ICA, with only a small bias (about 0.2% in flux) relative to ICA due to imperfect interpolation in using the look-up tables. In principle, the ICA albedo can be approximated accurately regardless of cloud inhomogeneity. For a more complete comparison, the broadband shortwave albedo and transmission calculated from the synthetic sPPH cloud and averaged over all incident directions, have the RMS biases of 0.26% and 0.76%, respectively, for inhomogeneous clouds over a wide variation of particle size. The advantages of the synthetic PPH method are that (1) it is not required that all the cloud subcolumns have uniform microphysical characteristic, (2) it is applicable to any 1D radiative transfer scheme, and (3) it can handle arbitrary cloud optical depth distributions and an arbitrary number of cloud subcolumns with uniform computational efficiency.

cloud inhomogeneity↗

Transfer Learning-Based Independent Component Analysis

Understanding the underlying component structure is crucial for multivariate signal analysis. Among all the techniques that try to learn the latent structure, independent component analysis (ICA) is one of the most important and popular methods, which aims to extract independent components from multivariate signals and enables further analysis. For example, in electroencephalogram (EEG) analysis, artifacts filtering and disease detection are conducted based on the independent components of the signals. One critical challenge in existing ICA approaches is that the component extraction accuracy may degrade when the available data of a unit are limited. To address this issue, this paper proposes a transfer learning-based ICA method by innovatively transferring component distribution from a source domain, so that accurate component extraction results can be achieved even when only limited data are available in the target domain. To the best of our knowledge, this is the first work that leverages transfer learning to improve ICA accuracy with limited available data. In particular, we first extract all the independent components from the source domain by maximizing the log-likelihood function with a Newton-like method on a smooth manifold. Then for the target domain, the component with the largest negentropy is extracted in each round. To effectively leverage the knowledge from the source domain and to prevent the negative transfer, we try to find a component in the source domain that matches the component we are extracting. The probability density function of the matched component will then be used to improve the component extraction accuracy if such matched component can be found; otherwise, no knowledge will be transferred. Finally, numerical simulations and a case study with electrocardiogram (ECG) data are conducted, showing the effectiveness of the proposed method in transferring knowledge and reducing negative transfer.

42 ENGINEERING↗

Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samples

An immunochromatographic assay (ICA) using gold nanoparticles coated with monoclonal antibody (McAb) for the detection of chromium ions (Cr) in water and serum samples was developed, optimized, and validated. Gold nanoparticles coated with affinity- purified monoclonal antibodies against isothiocyanobenzyl-EDTA (iEDTA)-chelated Cr3+ were used as the detecting reagent in this completive immunoassay-based one- step test strip. The ICA was investigated to measure chromium speciation in water samples. Chromium standard samples of 0-80 ng/mL in water were determined by the test strips. The results showed that the visual lowest detection limit (LDL) of the test strip was 50.0 ng/mL. A portable colorimetric lateral flow reader was used for the quantification of Cr. The results indicated that the linear range of the ICA with colorimetric detection was 5-80 ng/mL. The ICA was also validated for the detection of chromium ions in serum samples. The test trips showed high stability in that they could be stored at at 37 C for at least 12 weeks without significant loss of activity. The test strip also showed good selectivity for Cr detection with negligible interference from other heavy metals. Because of its low cost and short testing time (within 5 min), the test strip is especially suitable for on-site large- scale screening of Cr-polluted water samples, biomonitoring of Cr exposure, and many other field applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Independent component analysis for beam measurements

Independent component analysis (ICA) has been used for data mining in many branches of science. In beam physics, ICA can be applied to analyze turn-by-turn beam position monitor data of beam motion. The narrow-band filtering of ICA provides us methods to identify and extract information on the linear betatron and synchrotron motion, effects of wake fields, etc. We show that the ICA is also a powerful tool to measure nonlinear magnetic field in accelerators. Numerical simulations are used to demonstrate the ability to obtain sextupole strengths at high precision. The methods can be extended to other higher order multipoles.

43 PARTICLE ACCELERATORS↗

Conformers, infrared spectrum, UV-induced photochemistry, and near-IR-induced generation of two rare conformers of matrix-isolated phenylglycine

The conformational space of α-phenylglycine (PG) have been investigated theoretically at both the DFT/B3LYP/6-311++G(d,p) and MP2/6-311++G(d,p) levels of approximation. Seventeen different minima were found on the investigated potential energy surfaces, which are characterized by different dominant intramolecular interactions: type I conformers are stabilized by hydrogen bonds of the type N–H···O=C, type II by a strong O–H···N hydrogen bond, type III by weak N–H···O–H hydrogen bonds, and type IV by a C=O···H–C contact. The calculations indicate also that entropic effects are relevant in determining the equilibrium populations of the conformers of PG in the gas phase, in particular in the case of conformers of type II, where the strong intramolecular O–H···N hydrogen bond considerably diminishes entropy by reducing the conformational mobility of the molecule. In consonance with the relative energies of the conformers and barriers for conformational interconversion, only 3 conformers of PG were observed for the compound isolated in cryogenic Ar, Xe, and N{sub 2} matrices: the conformational ground state (ICa), and forms ICc and IITa. All other significantly populated conformers existing in the gas phase prior to deposition convert either to conformer ICa or to conformer ICc during matrix deposition. The experimental observation of ICc had never been achieved hitherto. Narrowband near-IR irradiation of the first overtone of νOH vibrational mode of ICa and ICc in nitrogen matrices (at 6910 and 6930 cm{sup −1}, respectively) led to selective generation of two additional conformers of high-energy, ITc and ITa, respectively, which were also observed experimentally for the first time. In addition, these experiments also provided the key information for the detailed vibrational characterization of the 3 conformers initially present in the matrices. On the other hand, UV irradiation (λ = 255 nm) of PG isolated in a xenon matrix revealed that PG undergoes facile photofragmentation through two photochemical pathways that are favored for different initial conformations of the reactant: (a) decarboxylation, leading to CO{sub 2} plus benzylamine (the dominant photofragmentation channel in PG cis-COOH conformers ICa and ICc) and (b) decarbonylation, with generation of CO plus benzonitrile, H{sub 2}O and H{sub 2} (prevalent in the case of the trans-COOH conformer, IITa)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-84: Comparison of Three Different Systems for Patient-Specific Quality Assurance: Cranial Stereotactic Radiosurgery Using VMAT with Multiple Non Coplanar Arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered. The purpose of the study is to compare three different dosimeters for pre-treatment QA. Methods: Nineteen patients (affected by neurinomas, brain metastases, and by meningiomas) were treated with VMAT plans computed on a Monte Carlo based TPS. Gafchromic films inside a slab phantom (GF), 3-D cylindrical phantom with two orthogonal diodes array (DA), and 3-D cylindrical phantom with a single rotating ionization chambers array (ICA), have been evaluated. The dosimeters are, respectively, characterized by a spatial resolution of: 0.4 (in our method), 5 and 2.5 mm. For GF we used a double channel method for calibration and reading protocol; for DA and ICA we used the 3-D dose distributions reconstructed by the two software sold with the dosimeters. With the need of a common system for analyze different measuring approaches, we used an in-house software that analyze a single coronal plane in the middle of the phantoms and Gamma values (2% / 2 mm and 3% / 3 mm) were computed for all patients and dosimeters. Results: The percentage of points with gamma values less than one was: 95.7% for GF, 96.8% for DA and 95% for ICA, using 3%/3mm criteria, and 90.1% for GF, 92.4% for DA and 92% for ICA, using 2% / 2mm gamma criteria. Tstudent test p-values obtained by comparing the three datasets were not statistically significant for both gamma criteria. Conclusion: Gamma index analysis is not affected by different spatial resolution of the three dosimeters.

60 APPLIED LIFE SCIENCES↗

Imaging Calorimeter for ACCESS Simulations with GEANT/FLUKA

Imaging Calorimeter for ACCESS (ICA) is a candidate of the calorimeter for the NASA's ACCESS program. The ICA studies the origin and acceleration mechanism of cosmic rays by measuring the elemental composition of the cosmic rays in the energy up to 10(exp 16) eV. For the past year, Monte Carlo simulation study for the ICA has been conducted to predict the detector performance and to design the system for match the scientific objectives. Simulation results show that the detector response resembles a Gaussian distribution and the energy resolution with ICA can be achieved about 40%. In addition, simulations of the detector's response to an assumed bent power law spectra in the region where the knee occurs have been conducted and clearly show that this detector can provide sufficiently accurate estimates of the spectral parameters that are a science goal of ACCESS.

Lee, Jeongin↗

A natural basis for efficient brain-actuated control

The prospect of noninvasive brain-actuated control of computerized screen displays or locomotive devices is of interest to many and of crucial importance to a few 'locked-in' subjects who experience near total motor paralysis while retaining sensory and mental faculties. Currently several groups are attempting to achieve brain-actuated control of screen displays using operant conditioning of particular features of the spontaneous scalp electroencephalogram (EEG) including central mu-rhythms (9-12 Hz). A new EEG decomposition technique, independent component analysis (ICA), appears to be a foundation for new research in the design of systems for detection and operant control of endogenous EEG rhythms to achieve flexible EEG-based communication. ICA separates multichannel EEG data into spatially static and temporally independent components including separate components accounting for posterior alpha rhythms and central mu activities. We demonstrate using data from a visual selective attention task that ICA-derived mu-components can show much stronger spectral reactivity to motor events than activity measures for single scalp channels. ICA decompositions of spontaneous EEG would thus appear to form a natural basis for operant conditioning to achieve efficient and multidimensional brain-actuated control in motor-limited and locked-in subjects.

NASA Discipline Space Human Factors↗

Initial Criticality Assessments to Guide FMEAs on Rocket Engine Hot Fire Testing

Presented is an explanation of the use of the Initial Criticality Assessment (ICA) technique, a triage process for prioritizing required Failure Modes and Effects Analysis (FMEAs), for the European Service Module's main propulsion system's hot-fire test bed at White Sands New Mexico. Rather than instinctively performing many FMEAs of subsystems, or one large system level FMEA where every subcomponent is analyzed, the ICA guided an informed analysis of only the hardware that had a large impact to hazards. The low criticality hardware was documented via the ICA and no FMEA was performed; the work could then focus on the high criticality hardware. Thus a savings of Program resources was achieved. The experiences gained in creating these ICAs for this international collaborative project confirmed that the need for continuous communication across the technical teams is one of the greatest areas of emphasis. The European Space Agency (ESA) is developing the European Service Module (ESM), with its primary contractor, Airbus Defence and Space in Germany, for delivery to the National Aeronautics and Space Administration (NASA). The module will be equipped with a total of 21 engines to support NASA’s Orion spacecraft: one U.S. Space Shuttle Orbital Maneuvering System-Engine (OMS-E), eight auxiliary thrusters and 12 smaller RCS (Reaction Control System) thrusters. The main ESM propulsion system, used for large translational maneuvers, consists of one OMS-E... To qualify the design of the ESM propulsion subsystem (PSS) an all-steel Propulsion Qualification Module (PQM) structure is used to test the propulsion systems on Orion, including “hot firing” of the OMS engine, thrusters, and RCS. The PQM has been developed as a hot-fire test bed to be tested at the NASA White Sands Test Facility (WSTF). One of the objectives of the testing is to assure that the OMS-E can be safely operated with the PQM. Testing will also demonstrate that the PQM can set the proper upstream pressures and temperatures for the OMS-E to operate nominally given the PQM has never been tested in hot-fire operation with OMS-E before. In order to safely conduct the test campaign, hardware such as the engine subassembly, fluid feed lines, valves, electrical power lines, instrumentation, stiff links, installation Ground Support Equipment (GSE), and diffuser [whose objectives are to collect the exhaust of the OMS-E to actively cool down the exhaust gases, reduce thermal exchanges, and create a vacuum at OMS-E level before igniting], had to be analyzed for any hazards and failure modes.

Fault Tolerance↗

Intracranial Effects of Artificial Gravity: A 3T MRI Study

INTRODUCTION Spaceflight associated neuro-ocular syndrome (SANS) is characterized by the development of optic disc edema, posterior globe flattening, choroidal/retinal folds and hyperopic refractive errors1. SANS is hypothesized to be a result of headward fluid shifts that invariably occurs in the microgravity environment. As a countermeasure, artificial gravity (AG) through centrifugation has been proposed to reduce this headward fluid shift, however there is no current proof of benefit. The goal of this study was to determine if the application of AG can prevent or reduce known changes in brain volumetry, internal carotid artery (ICA) stroke volume and cerebral spinal fluid (CSF) flow velocity that occurs during simulated chronic headward fluid shift using head down tilt bed rest (HDTBR) methodology2 as an indicator of countermeasure efficacy. METHODS Healthy volunteers were recruited for an IRB approved HDTBR study performed at the German Aerospace Center in Cologne, Germany. Strict six-degree HDTBR was used as a spaceflight analog to induce a continuous headward fluid shift. HDTBR was carried out for 60 days for all subjects. Short-arm centrifugation was utilized to generate AG equating to ~0.3g of acceleration at the level of the eye. The subjects were divided equally into three groups: NoAG (control; n=8), daily intermittent AG (6 x 5 min iAG; n=8), and daily continuous 30 min (cAG; n=8). All studies were performed on a single dedicated 3T MRI Scanner. Pulse-gated MRI phase-contrast flow imaging was used to quantify ICA stroke volume and peak-to-peak CSF flow velocity in the mid cerebral aqueduct. 3D-SPGR was acquired for volumetric segmentation of the brain and CSF spaces. MRI acquisitions were obtained at baseline (BDC), 14 days into HDTBR (HDTBR14), 52 days into HDTBR (HDTBR52) and 3-5 days after HDTBR (recovery, R+3/5).The data were analyzed by the mixed model, which included intervention and time (BDC, HDTBR 14, HDTBR 52, R+3/5) as the fixed effects and included subject as the random effect.RESULTS24 healthy subject volunteers (16 men, 8 women, mean age = 33 years ± 9 [standard deviation] and mean BMI = 24.3 kg/m2 ± 2.0) successfully completed all phases of the study. Strict six-degree HDTBR was characterized by progressive and statistically significant (p<.01) increases in mean combined brain and CSF volumes and mean aqueductal CSF peak-to-peak flow velocity, as well as statistically significant (p<.01) progressive decrease in mean ICA stroke volume from baseline to 52 days post intervention (Figs. 1-3). Compared to baseline, only combined brain and CSF volumes did not return to baseline values in the recovery period (p=NS). Neither iAG nor cAG exerted any significant effects on the measured MRI brain parameters as compared to HDTBR alone (p=NS). CONCLUSION Our results indicate that HDTBR at 6-degrees was effective in producing alterations in ICA stroke volume, aqueductal CSF flow velocity, and combined brain and CSF volumetric change that is associated with chronic headward fluid shift. Short duration, 30-min daily exposure to either iAG or cAG appears to be insufficient in preventing or reducing the effects of chronic HDTBR and thus may not be a suitable countermeasure as currently deployed. AG protocol modifications, including increased duration and magnitude of exposure, should be considered for future research.

L A Kramer↗

Towards interpretable Cryo-EM: disentangling latent spaces of molecular conformations

Molecules are essential building blocks of life and their different conformations (i.e., shapes) crucially determine the functional role that they play in living organisms. Cryogenic Electron Microscopy (cryo-EM) allows for acquisition of large image datasets of individual molecules. Recent advances in computational cryo-EM have made it possible to learn latent variable models of conformation landscapes. However, interpreting these latent spaces remains a challenge as their individual dimensions are often arbitrary. The key message of our work is that this interpretation challenge can be viewed as an Independent Component Analysis (ICA) problem where we seek models that have the property of identifiability. That means, they have an essentially unique solution, representing a conformational latent space that separates the different degrees of freedom a molecule is equipped with in nature. Thus, we aim to advance the computational field of cryo-EM beyond visualizations as we connect it with the theoretical framework of (nonlinear) ICA and discuss the need for identifiable models, improved metrics, and benchmarks. Moving forward, we propose future directions for enhancing the disentanglement of latent spaces in cryo-EM, refining evaluation metrics and exploring techniques that leverage physics-based decoders of biomolecular systems. Moreover, we discuss how future technological developments in time-resolved single particle imaging may enable the application of nonlinear ICA models that can discover the true conformation changes of molecules in nature. The pursuit of interpretable conformational latent spaces will empower researchers to unravel complex biological processes and facilitate targeted interventions. This has significant implications for drug discovery and structural biology more broadly. More generally, latent variable models are deployed widely across many scientific disciplines. Thus, the argument we present in this work has much broader applications in AI for science if we want to move from impressive nonlinear neural network models to mathematically grounded methods that can help us learn something new about nature.

59 BASIC BIOLOGICAL SCIENCES↗

Procedural Predictors of Outcome in Patients Undergoing Endovascular Therapy for Acute Ischemic Stroke

Purpose: To identify factors impacting outcome in patients undergoing interventions for acute ischemic stroke (AIS). Materials and Methods: This was a retrospective analysis of patients undergoing endovascular therapy for AIS secondary during a 30 month period. Outcome was based on modified Rankin score at 3- to 6-month follow-up. Recanalization was defined as Thrombolysis in myocardial infarction score 2 to 3. Collaterals were graded based on pial circulation from the anterior cerebral artery either from an ipsilateral injection in cases of middle cerebral artery (MCA) occlusion or contralateral injection for internal carotid artery terminus (ICA) occlusion as follows: no collaterals (grade 0), some collaterals with retrograde opacification of the distal MCA territory (grade 1), and good collaterals with filling of the proximal MCA (M2) branches or retrograde opacification up to the occlusion site (grade 2). Occlusion site was divided into group 1 (ICA), group 2 (MCA with or without contiguous M2 involvement), and group 3 (isolated M2 or M3 branch occlusion). Results: A total of 89 patients were studied. Median age and National Institutes of health stroke scale (NIHSS) score was 71 and 15 years, respectively. Favorable outcome was seen in 49.4% of patients and mortality in 25.8% of patients. Younger age (P = 0.006), lower baseline NIHSS score (P = 0.001), successful recanalization (P < 0.0001), collateral support (P = 0.0008), distal occlusion (P = 0.001), and shorter procedure duration (P = 0.01) were associated with a favorable outcome. Factors affecting successful recanalization included younger age (P = 0.01), lower baseline NIHSS score (P = 0.05), collateral support (P = 0.01), and shorter procedure duration (P = 0.03). An ICA terminus occlusion (P < 0.0001), lack of collaterals (P = 0.0003), and unsuccessful recanalization (P = 0.005) were significantly associated with mortality. Conclusion: Angiographic findings and preprocedure variables can help prognosticate procedure outcomes in patients undergoing endovascular therapy for AIS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Cervical Internal Carotid Artery Spontaneous Dissection with Pseudoaneurysm and Unilateral Lower Cranial Nerves Palsy by Two Silk Flow Diverters

Internal carotid artery (ICA) lesions in the parapharyngeal space (a dissection and a pseudoaneurysm) may present as isolated lower cranial nerves (IX, X, XI, and XII) palsy (Collet-Sicard syndrome). Some arteriopathies such as fibromuscular dysplasia and tortuosity make a vessel predisposed to dissection. Extreme vessel tortuosity makes the treatment by a stent graft impossible. Two Silk stents were used in a 46 year-old man with left lower cranial nerves (IX-XII) palsy for the treatment of left ICA spontaneous dissection with pseudoaneurysm. A follow-up angiogram 5 months later confirmed pseudoaneurysm thrombosis and patency of the left ICA. The patient recovered completely from the deficits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗