At least 37 records · Page 2

A new international standard on cybersecurity for nuclear power plants: IEC 62645 - cybersecurity requirements - 161

This paper provides an overview of the IEC 62645, an actual standard by the International Electrotechnical Commission (IEC) focused on the issue of requirements for computer security programmes and system development processes to prevent and/or minimize the impact of cyber attacks against computer-based I and C systems. Developed since 2009 and published end of 2014, the standard is intended to be used for changing or establishing new security programmes for I and C systems of operating and new Nuclear Power Plants (NPP). This paper also presents the key issues being considered in the new revision to IEC 62645, currently in process. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-Centric Communication Framework for Multicast IEC 61850 Routable GOOSE Messages over the WAN in Modern Power Systems

In this paper, a data-centric communication framework is proposed for multicast routable generic object-oriented substation event (GOOSE) messages (MRGM) over the wide area network (WAN) for effective substation-to-substation (SS2SS) and substation to control center (SS2CC) communications. In this structure, the IEC 61850 GOOSE message is transmitted over the WAN using the data distribution service (DDS) as a fast, reliable, and secure data-centric communication middleware. The main feature of this framework is its multicast capability, where several authorized subscribers can receive a published message simultaneously. This can significantly improve the system monitoring and control of the protection systems in modern smart grids, where intelligent schemes can be applied. The effectiveness of the proposed platform, in terms of total end-to-end delay between participants, is evaluated through experimental results obtained from the actual hardware-based test setup developed at the Florida International University (FIU) smart grid testbed. The results demonstrate that the latency between sending and receiving a GOOSE message among participants is within its maximum time span defined by the IEC 61850-90-5 working group for communications over the WAN.

42 ENGINEERING↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Enabling Interoperability on PV Inverters Using IEC 61850

Inverter based distributed energy resources are integrated into distribution system at a fast pace. Distribution management systems, microgrid controllers, and other distributed assets need to communicate with each other for sensing and control of the different assets. Interoperability is critical to the ease of data exchange between different assets. This presentation will provide a background on interoperability and a laboratory implementation using IEC 61850. Specifically, this presentation will discuss the use of IEC 61850 7-420 to enable interoperability in PV inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Technical Specification IEC TS 62989:2018 - Primary Optics for Concentrator Photovoltaic Systems

The first edition of the Technical Specification (TS) on Primary Optics for Concentrator Photovoltaic (CPV) Systems, IEC TS 62989:2018, has been published by the International Electrotechnical Commission (IEC), on March 8th, 2018. TS 62989 covers aspects related to the primary optics including: product identification, optical characteristics, mechanical characteristics, materials, (design) geometry, and visual appearance. This paper focuses on the key aspects of the norm, including optical performance, in order to promote the awareness and use of the standard. We describe the three methods intended to measure the key optical characteristics of the primary elements, i.e. focal spot size and optical efficiency, by using the encircled energy. The three methods are using different light sources, optical components and receiver sensors, but yielded very similar results in a round robin test. This justifies the continued use of all three methods. The use of a website (opticstests.pbworks.com) for documentation of discussions and references was novel to the standard development. The website proved to be useful for the introduction of new members of the group. The website helped to keep track of changes to the document as well as the required actions of the project team.

14 SOLAR ENERGY↗

IEC STANDARDS FOR INDIVIDUAL MONITORING OF IONISING RADIATION

This paper presents IEC/SC 45B Radiation protection instrumentation and its standards for individual monitoring of ionising radiation: IEC 61526 Ed. 3 for active personal dosemeters and IEC 62387-1 for passive integrating dosimetry systems. The transposition of these standards as CENELEC (European) standards is also discussed together with the collaboration between IEC/SC 45B and ISO/TC 85/SC 2.

61 RADIATION PROTECTION AND DOSIMETRY↗

From IEC 61853 power measurements to PV system simulations.

The IEC 61853 PV module energy rating standard requires measuring module power (and hence efficiency) over a matrix of irradiance and temperature conditions. These matrix points represent nearly the full range of operating conditions encountered in the field in all but the most extreme locations, and create an opportunity to develop alternative approaches to existing modelssuch as the single-diode models and the Sandia Array Performance Modelfor calculating system performance. This report begins by discussing the bilinear interpolation and extrapolation method from IEC 61853-3, and then describes four existing model-based methods that could be used with matrix measurements. Then a new model is developed and all options are compared according to seven objective criteria using the matrix measurements of four PV modules of different technologies. The results show that the new model is an excellent candidate for launching power matrix-based PV system simulations.

14 SOLAR ENERGY↗

Lessons from the IEC Durability of Adhesion Accelerated Test Sequence

The IEC 62788-1-1 and IEC 63209-2 standards use aging sequences for durability of adhesion in photovoltaic (PV) modules, which may be evaluated using the single cantilever beam (SCB) test. Because the encapsulant forms critical interfaces with the front glass and solar cells, degradation at those interfaces under ultraviolet (UV) exposure, elevated temperature, and humidity can lead to interfacial delamination - compromising the long-term reliability. In this work, adhesion durability of UV-transmitting poly(ethylene-co-vinyl acetate) (EVA) encapsulant to glass and to silicon solar cells is evaluated after sequenced UV and damp heat aging (85C/85%RH). Laminates were prepared using StarPhire solar front glass with thin glass or PERC cells, and two EVA formulations with different concentrations of siloxane coupling agent. Adhesion was quantified by measuring critical debond energy using the SCB method. Both formulations exhibit similar qualitative trends, while different adhesion is observed at the periphery despite the use of low-shrink manufacturing. The results show that while glass/EVA adhesion remains stable or increases after UV exposure and shows only moderate changes after damp heat, the EVA/cell interface exhibits an irreversible loss of adhesion following UV and then damp heat exposure. Although glass/EVA interfaces generally exhibit lower debond energies, the EVA/cell interface is significantly more vulnerable to UV-driven degradation, identifying it as the dominant reliability risk location through early- and intermediate-module life. These results demonstrate that accelerated aging sequences can expose large, interface-specific losses in adhesion durability and underscore the importance of interface engineering for long-term PV module reliability.

14 SOLAR ENERGY↗

Some Interplanetary Missions Using IEC Fusion Propulsion

IEC fusion offers the possibility of very efficient space propulsion with substantial thrust, examine human travel to the planets in order to determine the impact this technology could have reduced travel time and reduced fuel mass, travel via IEC propulsion is from earth orbit to another planetary orbit. Propulsion to a planet's or moon's surface assumed separate.

Hanson, John M.↗

IEC Research Status at MSFC

This viewgraph presentation gives an overview of the Inertial Electrostatic Confinement (IEC) research status at Marshall Space Flight Center. Details are given on the experiment setup (hardware characteristics, diagnostic equipment, propellant feed system, and planned pulse mode operation), grid manufacturing (identified manufacturing techniques, such as metal deposition, negative template mold, and machining), and grid for IEC operation (negative template technique and electrochemical technique).

Hrbud, Ivana↗

Inertial-Electrostatic Confinement (IEC) Fusion for Space Propulsion

An Inertial-Electrostatic Confinement (IEC) device was assembled at the Marshall Space Flight Center (MSFC) Propulsion Research Center (PRC) to study the possibility of using EEC technology for deep space propulsion and power. Inertial-Electrostatic Confinement is capable of containing a nuclear fusion plasma in a series of virtual potential wells. These wells would substantially increase plasma confinement, possibly leading towards a high-gain, breakthrough fusion device. A one-foot in diameter IEC vessel was borrowed from the Fusion Studies Laboratory at the University of Illinois@Urbana-Champaign for the summer. This device was used in initial parameterization studies in order to design a larger, actively cooled device for permanent use at the PRC.

Nadler, Jon↗

Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R&D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC. Key words: PLC, Safety, TJNAF, SIL, PSS, PPS, Software, ILC Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

43 PARTICLE ACCELERATORS↗

IEC 62859: A new international standard on the coordination between safety and cybersecurity for nuclear I and C systems - 160

Cybersecurity requirements and controls for digital I and C systems are increasingly added to well-established safety-oriented provisions. Interactions and potential side-effects are possible and must be mastered, taking into account the nuclear I and C system specificities as well as their normative and regulatory contexts. The new international standard IEC 62859 'Nuclear power plants - Instrumentation and control systems - Requirements for coordinating safety and cyber security' aims to optimize the integration of cybersecurity provisions in nuclear I and C architecture and systems, to prevent conflicts between safety and cybersecurity provisions, and to aid the identification and the leveraging of the potential synergies between safety and cybersecurity. The paper presents the structure and the key aspects of this standard. IEC 62859 is structured along three main sections: one dealing with the overall I and C architecture, a second one focusing on the system level, a third one dealing with organizational and procedural issues. The paper also discusses related work in the nuclear industry, and in other sectors. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Perovskite Photovoltaic Devices with Carbon-Based Electrodes Withstanding Reverse-Bias Voltages up to –9 V and Surpassing IEC 61215:2016 International Standard

One of the key challenges of perovskite photovoltaics (PV) is the long-term stability. Although efforts are made to improve the lifetime of perovskite PV devices, their degradation under reverse-bias conditions is barely addressed. Herein, perovskite solar cells with carbon-based electrodes are presented which demonstrate superior resilience against reverse-bias-induced degradation. Although their breakdown voltage is identified to be at approximately -3.6 V, cells do not degrade until the applied reverse-bias exceeds -9 V. Two main degradation mechanisms are identified: 1) iodine loss due to hole tunneling into perovskite, which takes place even at low reverse-bias but decomposes the perovskite only after long time durations; and 2) rapid heating at large reverse-bias leading to formation of PbI2, which starts at shunts and then follows the path of the least resistance for the cell current, which is primarily influenced by the electrode sheet resistances. Finally, perovskite solar modules with carbon-based electrodes are demonstrated, which are subjected to a "hotspot" test described in the IEC 61215:2016 international standard at an accredited module testing laboratory. Passing this accelerated test for the first time confirms the superior stability of perovskite PV devices with carbon-based electrodes and highlights their large industrialization potential.

14 SOLAR ENERGY↗

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY↗

LTE-P-7 IEC AEM SOP

A procedure for measuring the ion exchange capacity (IEC) of an anion exchange membrane (AEM). This is done via a titration method (automated or manual).

08 HYDROGEN↗

LTE-P-3 IEC PEM SOP

A procedure for measuring the ion exchange capacity (IEC) of a proton exchange membrane (PEM).

08 HYDROGEN↗