Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE PLANE BEAM COMBINATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Coronagraph Focal-Plane Phase Masks Based on Photonic Crystal Technology: Recent Progress and Observational Strategy

Photonic crystal, an artificial periodic nanostructure of refractive indices, is one of the attractive technologies for coronagraph focal-plane masks aiming at direct imaging and characterization of terrestrial extrasolar planets. We manufactured the eight-octant phase mask (8OPM) and the vector vortex mask (VVM) very precisely using the photonic crystal technology. Fully achromatic phase-mask coronagraphs can be realized by applying appropriate polarization filters to the masks. We carried out laboratory experiments of the polarization-filtered 8OPM coronagraph using the High-Contrast Imaging Testbed (HCIT), a state-of-the-art coronagraph simulator at the Jet Propulsion Laboratory (JPL). We report the experimental results of 10-8-level contrast across several wavelengths over 10% bandwidth around 800nm. In addition, we present future prospects and observational strategy for the photonic-crystal mask coronagraphs combined with differential imaging techniques to reach higher contrast. We proposed to apply a polarization-differential imaging (PDI) technique to the VVM coronagraph, in which we built a two-channel coronagraph using polarizing beam splitters to avoid a loss of intensity due to the polarization filters. We also proposed to apply an angular-differential imaging (ADI) technique to the 8OPM coronagraph. The 8OPM/ADI mode avoids an intensity loss due to a phase transition of the mask and provides a full field of view around central stars. We present results of preliminary laboratory demonstrations of the PDI and ADI observational modes with the phase-mask coronagraphs.

coronagraphy↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

Instruments for Imaging from Far to Near

The acronym CHAMP (signifying camera, hand lens, and microscope ) denotes any of several proposed optoelectronic instruments that would be capable of color imaging at working distances that could be varied continuously through a range from infinity down to several millimeters. As in any optical instrument, the magnification, depth of field, and spatial resolution would vary with the working distance. For example, in one CHAMP version, at a working distance of 2.5 m, the instrument would function as an electronic camera with a magnification of 1/100, whereas at a working distance of 7 mm, the instrument would function as a microscope/electronic camera with a magnification of 4.4. Moreover, as described below, when operating at or near the shortest-working-distance/highest-magnification combination, a CHAMP could be made to perform one or more spectral imaging functions. CHAMPs were originally intended to be used in robotic geological exploration of the Moon and Mars. The CHAMP concept also has potential for diverse terrestrial applications that could include remotely controlled or robotic geological exploration, prospecting, field microbiology, environmental surveying, and assembly- line inspection. A CHAMP (see figure) would include two lens cells: (1) a distal cell corresponding to the objective lens assembly of a conventional telescope or microscope and (2) a proximal cell that would contain the focusing camera lens assembly and the camera electronic image-detector chip, which would be of the active-pixel-sensor (APS) type. The distal lens cell would face outward from a housing, while the proximal lens cell would lie in a clean environment inside the housing. The proximal lens cell would contain a beam splitter that would enable simultaneous use of the imaging optics (that is, proximal and distal lens assemblies) for imaging and illumination of the field of view. The APS chip would be mounted on a focal plane on a side face of the beam splitter, while light for illuminating the field of view would enter the imaging optics via the end face of the beam splitter. The proximal lens cell would be mounted on a sled that could be translated along the optical axis for focus adjustment. The position of the CHAMP would initially be chosen at the desired working distance of the distal lens from (corresponding to an approximate desired magnification of) an object to be examined. During subsequent operation, the working distance would ordinarily remain fixed at the chosen value and the position of the proximal lens cell within the instrument would be adjusted for focus as needed.

Mungas, Greg↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

Star Tracker Accuracy Improvement and Optimization for Attitude Measurement in Three-Axis

High precision attitude measurement systems obviate the need for the beacon from the receiver making it possible for the spacecraft to beam a laser communications signal to a ground station without the ground station advertising its location. The research presented targets new detection and estimation methods to improve the accuracy in locating stars on a focal plane detector, and an understanding of the effects of changes in the optics design parameters and aberration, including defocus, on the navigation solution itself. This understanding can lead to an optimization of the attitude solution with respect to those optics realm parameter changes. The methodology discussed includes the development of a model of a current star tracker system. Using this model, multiple algorithms are implemented, including a multi-hypothesis method (MHT), to detect and estimate the position of the stars on the focal plane detector. It will be shown that using the MHT for detection and estimation, a greater accuracy can be found for each star estimation from more traditional detection and estimation algorithms. The approach then uses the model to develop statistics of the star tracker and the attitude estimation outputs to understand the accuracy, or variance, of the system's attitude solution. This solution is repeated for a range of defocus aberration, and a lower limit to the variance of the attitude solution is shown. A Cramer Rao lower bound solution is derived for the star tracker system and the results are compared to the Monte Carlo analysis from the model and shown to correlate very well. The approach uses a star image not as a Gaussian spot on the focal plane as done in previous work, and use of an image that includes the effects of aberrations of the optic system, and the effects of under-sampling and noise from the focal plane detector as well. Analysis includes exploring a star tracker's accuracy improvement through the combination of focus error and under-sampling effects alone, possibly contradicting conventional wisdom and approaches.

Lichter, Michael J.↗

A New Statistical Estimate of the Radar Coverage of the Low Earth Orbit Debris Environment

For over three decades, the NASA Orbital Debris Program Office (ODPO) has used the Goldstone Orbital Debris Radar, Haystack Ultrawideband Satellite Imaging Radar (HUSIR), and Haystack Auxiliary (HAX) radar assets to collect data on the low Earth orbit (LEO) debris environment. Each radar, with its unique beamwidth, altitude and inclination coverage, and limiting size threshold, operates in a beam park mode to statistically sample the orbital debris population in LEO. Provided that these assets are shared with other users, the orbital debris data collection is not continuous; rather, intermittent data collects are acquired and sent to the NASA ODPO. To understand the sampling process conducted by each radar over time and any related observational biases, a Statistical Confirmation of Radar Uniformity or Bias (SCRUB) code has been implemented to model the coverage of these assets for informing future operations, as well as usage of the data collected from these ground-based sensors. For this analysis, Right Ascension of the Ascending Node (RAAN) is used as a metric to measure statistical coverage. A complete survey of the LEO environment is understood to be measurements that sufficiently sample all values of RAAN for each altitude-inclination pair visible from the radar asset. Regions of incompleteness or statistical bias can help inform future observation campaigns. The SCRUB tool evaluates the coverage of the LEO environment, not by examining individual objects that may pass through a sensor’s field of view (FOV), but by determining which orbit planes pass through the FOV. Once a pointing geometry for a radar site, observation time, and range extent are configured by the user, SCRUB computes the inclinations and altitudes that are visible by the sensor. For each inclination-altitude pair, there is a distinct pair of possible RAAN values, corresponding to the ascending and descending orbit passing through that point in the sensor cone. Repeating this process for all points in the beam, and for multiple time periods during an observation window, creates a matrix of all inclination-altitude-RAAN combinations that are visible during a sensor run. This process can then be repeated for all observations within a year (for an annual survey), propagating all the RAAN values to a common epoch, typically the start of a calendar year, and combining the observations to assemble a full estimate of the RAAN coverage of the LEO environment. This RAAN coverage can then be analyzed for uniformity of sampling, within a certain inclination-altitude pair, or between larger regions of the space environment. This paper provides a general overview of the radar assets utilized by ODPO, typical analysis data products assuming circular orbits, and a discussion of the algorithms that feed between modeling and measurement operations. Following the description of the algorithm, estimates of coverage using HUSIR radar data collected from multiple years are developed and compared.

Chris L Ostrom↗

Experimental Investigation of Pool Boiling Heat Transfer Enhancement in Microgravity in the Presence of Electric Fields

In boiling high heat fluxes are possible driven by relatively small temperature differences, which make its use increasingly attractive in aerospace applications. The objective of the research is to develop ways to overcome specific problems associated with boiling in the low gravity environment by substituting the buoyancy force with the electric force to enhance bubble removal from the heated surface. Previous studies indicate that in terrestrial applications nucleate boiling heat transfer can be increased by a factor of 50, as compared to values obtained for the same system without electric fields. The goal of our research is to experimentally explore the mechanisms responsible for EHD heat transfer enhancement in boiling in low gravity conditions, by visualizing the temperature distributions in the vicinity of the heated surface and around the bubble during boiling using real-time holographic interferometry (HI) combined with high-speed cinematography. In the first phase of the project the influence of the electric field on a single bubble is investigated. Pool boiling is simulated by injecting a single bubble through a nozzle into the subcooled liquid or into the thermal boundary layer developed along the flat heater surface. Since the exact location of bubble formation is known, the optical equipment can be aligned and focused accurately, which is an essential requirement for precision measurements of bubble shape, size and deformation, as well as the visualization of temperature fields by HI. The size of the bubble and the frequency of bubble departure can be controlled by suitable selection of nozzle diameter and mass flow rate of vapor. In this approach effects due to the presence of the electric field can be separated from effects caused by the temperature gradients in the thermal boundary layer. The influence of the thermal boundary layer can be investigated after activating the heater at a later stage of the research. For the visualization experiments a test cell was developed. All four vertical walls of the test cell are transparent, and they allow transillumination with laser light for visualization experiments by HI. The bottom electrode is a copper cylinder, which is electrically grounded. The copper block is heated with a resistive heater and it is equipped with 6 thermocouples that provide reference temperatures for the measurements with HI. The top electrode is a mesh electrode. Bubbles are injected with a syringe into the test cell through the bottom electrode. The working fluids presently used in the interferometric visualization experiments, water and PF 5052, satisfy requirements regarding thermophysical, optical and electrical properties. A 30kV power supply equipped with a voltmeter allows to apply the electric field to the electrodes during the experiments. The magnitude of the applied voltage can be adjusted either manually or through the LabVIEW data acquisition and control system connected to a PC. Temperatures of the heated block are recorded using type-T thermocouples, whose output is read by a data acquisition system. Images of the bubbles are recorded with 35mm photographic and 16mm high-speed cameras, scanned and analyzed using various software packages. Visualized temperature fields HI allows the visualization of temperature fields in the vicinity of bubbles during boiling in the form of fringes. Typical visualized temperature distributions around the air bubbles injected into the thermal boundary layer in PF5052 are shown. The temperature of the heated surface is 35 C. The temperature difference for a pair of fringes is approximately 0.05 C. The heat flux applied to the bottom surface is moderate, and the fringe patterns are regular. In the image a bubble penetrating the thermal boundary layer is visible. Because of the axial symmetry of the problem, simplified reconstruction techniques can be applied to recover the temperature field. The thermal plume developing above the heated surface for more intensive heating is shown. The temperature distribution in the liquid is clearly 3D, and tomographic techniques have to be applied to recover the temperature distribution in such a physical situation. A sequence of interferometric images showing the temperature distribution around the rising bubble, recorded with a high-speed camera is shown. Again, the temperature distribution is 3D, and a more complex approach to the evaluation, the tomographic reconstruction has to be taken. Measurement of the temperature distribution from the fringe pattern temperature distributions that yield important information regarding heat transfer are determined. Two algorithms that allow the quantitative evaluation of interferometric fringe patterns and the reconstruction of temperature fields during boiling have been developed at the Heat Transfer Laboratory of the Johns Hopkins University. In the first algorithm the bubble is assumed to be axially symmetrical, which significantly reduces the computational effort for quantifying the temperature distribution around the bubble. For this purpose the thermal boundary layer around the bubble is divided into equidistant concentric shells, and the refractive index is assumed to be constant in each of the shells. Since large temperature gradients are expected in the vicinity of the bubble during boiling, the deflection of the light beam cannot be neglected in boiling experiments. Since the exit angle of the light beam is known, this allows to account for the deflections and phase shifts outside the boundary layer (in the bulk fluid and in the windows of the test cell). Three dimensional temperature distributions in the vicinity of the bubble are reconstructed using tomographic techniques. In tomography, the measurement volume is sliced into 2D planes. In the present study these planes are parallel to the heated surface. The objective is to determine the values of the field parameter of interest in form of the field function in these 2D planes. The field parameter is the change of the refractive index of the liquid in the measurement volume caused by temperature changes. By superimposing data for many 2D planes recorded at the same time instant, the 3D temperature distribution in the measurement volume is recovered.

Herman, Cila↗