Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data storage, image tube type

Method and apparatus for the storage of digital or analog electrical signals are provided by a memory storage system employing a conventional vidicon tube. At the beginning of an operating cycle, the vidicon is conditioned to accept electrical data input by exposing its photosensitive target to a short, high intensity light flash. A first electron beam scan of the photosensitive surface then sets up a charge pattern on the photosensitive target. A second electron beam scan of the photosensitive surface by an unmodulated electron beam then develops an output signal across an output resistor by using capacitive currents. The conditioning and scanning steps are operated repetitively at high speed using conventional television camera scan, sync, and power supply circuitry to provide a low cost data storage system.

Lipoma, P. C.↗

Image tube spectroscopic studies of rapid variables. IV - Spectroscopic and photometric observations of AE Aquarii

Photoelectric and time-resolved spectroscopic observations of the short-period eruptive binary AE Aqr are presented. The system has a period of 0.4116537 days, and emission and absorption-line components equal to 135 km/sec and 159 km/sec, respectively. The spectral type of the absorption-line component is found to be K5V, from which M1 = 0.82 solar mass, M2 = 0.69 solar mass, and i = 64 deg. A predominantly Ca II emission region occurs on the hemisphere of the K5V star facing the broad emission-line component, whose center of light is located 0.64 of the way from the inner Lagrangian point to the center of mass of the K star. This emission appears to be associated with the transfer of mass from the K5V star to the accretion disk surrounding the primary. In the absence of flare activity, the light of the system is variable in the orbital period with a range in V of about 0.16 mag; maxima occurs near the times of maximum recession velocity and during the approach of each of the two components of the system (0.25 P and 0.80 P).

Chincarini, G.↗

Integral image tube-optical systems for the far UV.

Description of proposed image tube optical systems for narrow-band direct photography and broad bandpass photography from spacecraft outside the atmosphere. For narrow-band photography an f/1.5 Schmidt camera with a photocathode located on the focal surface is recommended. The photoelectrons are accelerated and magnetically focused onto a phosphor/fiber optics surface, the curvature of which partially corrects for distortions of the electric field introduced by the curved photocathode. The second stage can be any other tube, electrostatically or magnetically focused, having a fiber optics faceplate butted to the first stage. For broad bandpass a spectrograph with an f/3 all-reflecting Schmidt image tube camera is recommended.

Chincarini, G.↗

Thermal neutron image intensifier tube provides brightly visible radiographic pattern

Vacuum-type neutron image intensifier tube improves image detection in thermal neutron radiographic inspection. This system converts images to an electron image, and with electron acceleration and demagnification between the input target and output screen, produces a bright image viewed through a closed circuit television system.

Berger, H.↗

Spaceborne astronomy with electro-optical image sensors

The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.

Bradley, W. C.↗

Photoelectron counting with an image intensifier tube and a self-scanned photodiode array

A self-scanned photodiode array was fiber-optically coupled to an ITT proximity-focused image intensifier tube. It was determined that a single photoelectron event produces 34,000 charge carriers in a photodiode. This charge is only a factor of 2.8 above the rms noise level of the preamplifier used in the tests, but standard charge-sensitive techniques are at least a factor of 12 better. The image tube and photodiode array combination can be packaged in a disk 5.1 cm in diameter and 2.6 cm thick.

Sandel, B. R.↗

Image intensifier tube observations of the OH airglow during the Space Shuttle simulation

The OH airglow studies discussed have evolved from a lead-sulfide-cell scanning photometer to photographic techniques to, currently, image-tube photography. During the Space Shuttle Simulation, photography (35-mm and 16-mm) and filter-wheel photometry of submicron OH airglow were performed aboard the NASA CV990 Airborne Laboratory. Examples of ground-based and airborne photographs are presented for comparison. Analysis of the aircraft data is described.

Peterson, A. W.↗

Electron-optic limitations on image resolution

Various approaches are considered to the solution of the electron-optical problem of designing an image tube configuration. Emphasis is placed on the method of computer design, and an illustration is given in which the technique is used in the design of an 80-mm image tube with a zoom capability of 3:1. The solutions are discussed to such problems as image distortion, magnification, and electron bundles striking the zoom electrode. Three types of an electron-optical configuration are examined for the electron-optic limitations to resolution: (1) the proximity image tube, (2) the magnetic-type image tube having uniform electric and magnetic fields, and (3) the electrostatic-type image tube such as the 80-mm zoom tube.

Engstrom, R. W.↗

Interfacing a Two-Stage Image Intensifier Tube to an Echelle Spectrograph

An Echelle spectrograph has been in use at the Marshall Space Flight Center for a number of years. Research has been carried out in the study of the internal motions of ionized gas clouds in the interstellar medium. In order to extend the ability of the spectrograph to allow investigations of the faint outer regions of the gas clouds and to make possible the initiatiion of new research programs dealing with the study of sunspots and the zodiacal light, a two-stage image intensifier tube was incorporated into the instrument. The objective of this work was to interface the image tube with the spectrograph.

Flesch, T. R.↗

The remote-controlled spectrograph, area scanner, and spectropolarimeter for the Lick 3-m telescope

A Cassegrain spectrograph used in conjunction with an image-tube, image-dissector scanner (ITS) is discussed with reference to its design features and operation. The spectrograph has a remote control feature, and its parameters, such as slit width, decker position, filter selection, focus, and grating selection, can be easily changed by computer command or a hard-wired control box. The discussion also includes the area scanner modification which allows raster scanning and limited picture taking. Finally, the design of a two-channel polarization analyzer is presented which allows simultaneous sky and sky-plus-star observations and faint-object polarimetry.

Miller, J. S.↗

Hard- and software problems of spaced meteor observations by optical electronics

An optical electronic facility is being used for meteor observations along with meteor radars and astronomical TV. The main parts of the facility are cameras using UM-92 optical electronic image tubes. The three cascade optical electronic image tube with magnetic focusing has a 40 mm cathode and resolution in the center of up to 30 pairs of lines/mm. The photocathode is of a multislit S-20 type. For meteor spectra observations, replica gratings of 200 and 300 lines/mm are used as the dispersive element.

Shafiev, R. I.↗