Effect of Sandpaper and Grain Size on Non‐Shock Initiated Reactions in HMX

Abstract Three grades of HMX samples, coarse (A), coarse with a small amount of fines (B), and ultra‐fine (F), were tested for impact sensitivity by ERL drop hammer. The Type 12A test used sandpapers of three different compositions, 120‐, 180‐grit Si/C and 180‐grit garnet. Reaction was accounted for by operator observation and microphone. The results showed different sensitivity for each of the HMX types. The F‐HMX was the smallest in average particle size and was the least sensitive to impact. The A‐HMX was the next most stable and the B‐HMX was the most sensitive to impact. The spent samples from the drop hammer testing of B‐HMX and F‐HMX were further evaluated with optical imaging. Conditions were selected that were near the DH 50 values of the specific HMX. Previous literature has cited localized hot spot formation to be the probable cause of non‐shock initiated reactions leading to impact sensitivity. This study yielded a plethora of samples exhibiting hot spots for HMX materials, both without and with proximity to grit particles. Hot spots in the proximity of grit particles gave the most dramatic hot spots, but both types of hot spots were exhibited in samples considered reacted and non‐reacted. The F‐HMX, even though the most stable to impact sensitivity, exhibited the most and best resolved hot spots of all the samples and conditions. Foreign objects were also observed in some of the samples. Previous work has shown metal particles coming from wear of the anvils used in the drop hammer experiment can also form hot spots. However, none of the samples here with metal particles exhibited, in proximity, hot spot formation.

Reynolds, John G.↗

Predictability of Gaseous Impact Ignition Sensitivity from Autoignition Temperature Data

An analysis of cumulative binomial probabilities for a quantal-type test like ASTM G74 indicates that for a probability of reaction in a single trial of 0.05, the probability of obtaining zero reactions in 20 trials is only approximately 36 percent, Because the lack of precision with the ASTM G74 test logic could be potentially misleading, an investigation was conducted to determine if pneumatic impact sensitivity could be predicted more reliably from other, more precise test methods. Pneumatic impact sensitivity tests were conducted following ASTM G74, but employing more rigorous test logics; autoignition temperature tests were conducted per ASTM G72. Polytetrafluoroethylene (PTFE), Viton A, polyethylene, polyoxymethylene polyamide, and silicone were the polymers used. After a fixed number of pneumatic impact tests was performed at set pressures, a plot of reaction frequency over a 3.4 to 24.1 MPa impact pressure range indicated that PTFE, Viton A, and silicone would outperform other polymers. The 50 percent pneumatic impact reactivity level was determined with the Bruceton test method. The data obtained resulted in a strong correlation between the 50 percent reactivity level and the autoignition temperature of polymers, indicating similar ignition mechanisms.

Hirsh, David↗

A BRIEF DESCRIPTION OF THE SMALL-SCALE SAFETY TESTING SYSTEMS AT LAWRENCE LIVERMORE NATIONAL LABORATORY

Small-scale sensitivity testing is important for determining material response to various stimuli including impact, friction, and static spark. These tests, briefly described below, provide parameters for safety in handling. ERL Type 12 drop hammer equipment at LLNL, shown in Figure 1, was used to determine the impact sensitivity. The equipment includes a 2.5-kg drop weight, a striker (upper anvil, 2.5 kg for solid samples and 1.0 kg for liquid samples), a bottom anvil, a microphone sensor, and a peakmeter. For each drop, sample (35 mg for solid or 45 microliter for liquid) is placed on the bottom anvil surface and impacted by the drop weight from different heights. Signs of reactions upon impact are observed and recorded. These signs include noises, flashes or sparks, smoke, pressure, gas emissions, temperature rise due to exothermic reaction, color change of the sample, and changes to the anvil surface (noted by inspection). For solid samples, a 'GO' was defined as a microphone sensor (for noise detection) response of {ge} 1.3 V as measured by a peakmeter. The higher the DH{sub 50} values, the lower the impact sensitivity. The method used to calculate DH{sub 50} values is the 'up and down' or Bruceton method. PETN and RDX have impact sensitivities of 15 and 35 cm, respectively. TATB has impact sensitivity more than 177 cm. For liquid samples, a 'GO' was determined by the noise levels as measured by the peakmeter, appearance of flashes, temperature rise of the anvil, and visual inspection of the anvil surface. Two liquid samples TMETN and FEFO have impact sensitivities of 14 and 32 cm, respectively. Figure 2 shows a 'GO' event observed during the impact sensitivity test; flashes appeared as the drop weight impacted the sample. A BAM friction sensitivity test machine, as shown in Figure 3, was used to determine the frictional sensitivity. The system uses a fixed porcelain pin and a movable porcelain plate that executes a reciprocating motion. Weight affixed to a torsion arm allows for a variation in applied force between 0.5 kg to 36.0 kg. The relative measure of the frictional sensitivity of a material is based upon the smallest load (kg) at which reaction occurs for a 1-in-10 series of attempts. The lower the load values, the higher the frictional sensitivity. PETN has a frictional sensitivity of 6.4 kg. The static spark machine at LLNL is used to evaluate the electrostatic discharge hazards (human ESD) associated with the handling of explosives. The machine was custom-built almost 30 years ago and consists of a capacitor bank (up to 20,000 pF), a voltage meter, and a discharge circuit, as shown in Figure 4. An adjustable resistor up to 510 ohms (chosen to simulate human body) is wired to the discharge circuit. A 5-mg sample is placed in a Teflon washer sealed to a steel disc and covered with a Mylar tape. High static voltage (up to 10 kv) is applied and discharged to the sample. Evidence of reaction is judged from the condition of Mylar tape, smokes, and color change of the sample. Voltage, capacitance, and resistance can be adjusted to achieve the desired static energy. The results obtained are expressed as a zero in 10 or one-in-ten at a specific voltage and joules. One reaction in ten trials at {le} 0.25 joules is considered spark-sensitive. Primary explosives show reaction at 0.1 joule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlating Mechanical Sensitivity with Spin Transition in the Explosive Spin Crossover Complex [Fe(Htrz) 3 ] n [ClO 4 ] 2 n

Spin crossover complexes are known to undergo bond length, volume, and enthalpy changes during spin transition. In an explosive spin crossover complex, these changes could affect the mechanical and initiation sensitivity of the explosive and lead to the development of a new class of sensitivity switchable materials. To explore this relationship, the well-known spin crossover compound [Fe(Htrz) 3 ] n [ClO 4 ] 2n (1) was re-evaluated for its explosive properties, and its mechanical impact sensitivity was correlated to spin transition. A variable temperature impact test was developed and used to evaluate the impact sensitivity of 1 in the low spin (LS, S = 0), thermally accessed high spin (HS, S = 2), and mixed LS and HS states. For comparison, the structurally similar Ni compound, [Ni(Htrz) 3 ] n [ClO 4 ] 2n (2), which does not undergo a spin transition at accessible temperatures, was synthesized and characterized, and its explosive properties and variable temperature impact sensitivity measured. These results reveal a correlation between impact sensitivity and spin transition, where 1 exhibits lower impact sensitivity in the LS state and increases in sensitivity upon transition to the HS state. Here, density functional theory was used to predict structural changes that occur upon spin transition that correlate to the change in sensitivity. This demonstrates, for the first time, an explosive spin crossover compound (ExSCO) that exhibits switchable impact sensitivity with a fully reversible internal switching mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity of Impact Risk to Uncertainty in Asteroid Properties and Entry Parameters

A central challenge in evaluating the threat posed by asteroids striking Earth is the large amount of uncertainty in potential asteroid properties and entry parameters, which can vary the resulting ground damage and affected population by orders of magnitude. We are using our Probabilistic Asteroid Impact Risk (PAIR) model to investigate the sensitivity of asteroid impact damage to these uncertainties. To assess the risk sensitivity, we alternately fix or vary the different input parameters and compare the damage distributions produced. In this study, we consider local ground damage from blast waves or thermal radiation for impactors 50-500m in diameter. The ongoing goal of this work is to help guide future efforts in asteroid characterization and model refinement by determining which properties most significantly affect the potential risk.

Wheeler, Lorien↗

Cd(II) complexes with different nuclearity and dimensionality based on 3-hydrazino-4-amino-1,2,4-triazole

A series of zero- to two-dimensional Cd(II) coordination compounds have been synthesized by the reaction of Cd(II) salts and 3-hydrazino-4-amino-1,2,4-triazole di-hydrochloride (HATr·2HCl). [CdCl{sub 2}(HATr){sub 2}] (1) and [Cd{sub 2}Cl{sub 4}(HATr){sub 2}(H{sub 2}O){sub 2}] (2) have discrete mononuclear and binuclear structures, respectively. [Cd(HATr){sub 2}(ClO{sub 4}){sub 2}]{sub n} (3) presents polymeric 1-D chain and [Cd{sub 2}(NO{sub 3}){sub 2}Cl{sub 2}(HATr){sub 2}]{sub n} (4) shows 2-D frameworks. All Cd(II) ions exhibit distorted octahedral configurations in 1–3, whilst both hexa and heptacoordinated Cd(II) are formed in 4. The HATr ligands adopt chelating coordinated mode in 1, while tri-dentate bridging–chelating mode in 2–4. The chloride ion is a mono-coordinated ligand in 1 and 2, but it bridges two adjacent metal ions in 4. Furthermore, thermal behaviors have been investigated and the results reveal that all complexes have good thermal stability. The impact sensitivity test indicates that complex 3 is sensitive to impact stimuli. - Graphical abstract: Four Cd(II) complexes based on 3-hydrazino-4-amino-1,2,4-triazole ligands exhibit diverse structures from mononuclear to 2D networks. - Highlights: • Cd(II) complexes containing 3-hydrazino-4-amino-1,2,4-triazole ligands. • Mononuclear, binuclear, 1-D and 2-D structures. • Good thermal stability. • Thermal decomposition kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical absorption in polycrystalline PETN, RDX, HMX, CL-20 and HNS and its possible effect on exploding bridgewire detonator function

Exploding bridgewire (EBW) detonators work by bursting a thin conducting wire as a result of a high voltage discharge. This process is known to produce a strong UV emission. In this work, the roles of optical absorption, photochemistry, shock sensitivity, and impact sensitivity are assessed with respect to the relative roles each plays in the operation of an EBW detonator. The optical absorptivity and penetration depth have been measured using dilute polycrystalline samples of PETN, RDX, HMX, CL-20 and HNS in KBr between 190 and 1100 nm. The results show strong absorption at UV wavelengths with a gradual decline at longer ones. It is found that while strong UV absorption appears to be necessary, it is not sufficient to make an effective EBW detonator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pyrotechnic hazards classification and evaluation program. Phase 3, segments 1-4: Investigation of sensitivity test methods and procedures for pyrotechnic hazards evaluation and classification, part A

The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.

Source record↗

Synthesis and investigation into explosive sensitivity for a series of new picramide explosives

Tailoring the molecular properties that govern energetic material sensitivity is essential to improve safety and help develop new energetic materials. Despite this need, understanding the complex chemistry and physics of explosive initiation and propagation is still a challenge. Recent work by our group has reinforced the view that explosive sensitivity under sub-shock conditions is connected to the strength of the weakest covalent bond in the molecule, that is, its “trigger linkage.” These correlations have been observed with different classes of energetic molecules and indicate that “trigger linkage” bond breaking, and heat of explosion are good indicators for the sensitivity trends. Herein we report the synthesis of aliphatic energetic materials with ethane, propane and neopentane backbones. Experimental and computational studies show that the trigger linkage model, based on results from quantum molecular dynamics simulations, correctly predicts trends observed in the impact sensitivity of the molecules. However, while the model predicts the impact sensitivities of the ethane series, the neopentane series has higher impact sensitivities than predicted, which is presumably influenced by crystal packing effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Impact of Flow on Material-Sensitive Critical Heat Flux and Boiling Heat Transfer Coefficients: An Experimental Study with Various Materials

In this work, steady-state internal flow boiling critical heat flux (CHF) experiments were carried out at 10°C inlet subcooling and atmospheric pressure (84 kPa at an altitude of about 5300 feet) with mass flux ranging from 200 to 2,000 kg/m 2 -s on seven tube materials, including the accident-tolerant fuel cladding candidate FeCrAl (C26M) alloy. At a relatively low flow rate, the sensitivity of CHF to different materials was appreciable (the average difference among the tested materials was 19% at 200 kg/m 2 -s). As the absolute CHF differences stayed constant for higher flow rates, the increased flow rate led to reduced relative CHF differences among the tested materials (average relative difference of 15% at 1,000 kg/m 2 -s). FeCrAl alloy claddings that were oxidized under simulated Light Water Reactor (LWR) conditions yielded CHF comparable to as-received FeCrAl alloy cladding, with less than 1.8% difference. Experimental CHF results imply marginal material sensitivity impacts on the departure from nucleate boiling ratio in steady-state nuclear reactor cores. Yet, for accident progression analysis, material sensitivity may hold importance, as boiling behavior variation at low mass flux is appreciable. Macroscopic material parameters (surface wettability, surface roughness, and thermal properties) do not provide a suitable explanation for observed material-sensitive CHFs. Yet, surface roughness and thermal effusivity revealed power and linear relations, respectively, to the nucleate boiling heat transfer coefficients at low mass flux. At high mass flux, material sensitivity on nucleate boiling heat transfer significantly decreased due to the increased shear stress on boiling surface overwhelming material-related boiling implications.

36 MATERIALS SCIENCE↗

Small-Scale Sensitivity Testing (SSST) Report

Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1 cm increments, though 1 cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Positive results were detected visually or audibly by the operator as smoke, flash, report, charring/tearing of the sandpaper, etc. The test was conducted using the Bruceton technique to calculate the height at which there is a 50% chance of initiation (H 50 ).

42 ENGINEERING↗

Safety and sensitivity of nitroglycerine (NG) mixtures

Small scale (SSST) safety tests were conducted to determine impact sensitivity, friction sensitivity and spark sensitivity of nitroglycerine (NG) and its mixtures. The tests were done for the following formulations (totally 9): NG (1% stabilizer), NG with diluents (acetone and triacetin), and mixture of NG and nitrocellulose (NC). Aging study was also performed on NG/NC mixture to determine the effect of aging on sensitivity. The test results are summarized in this report.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An arbitrary Lagrange-Eulerian investigation of HRAM shallow jet pre-spurt formation and time sensitivities to impact plate dynamics

With dry bay fires persisting as a significant contributor to aircraft vulnerability despite chronicled developments in survivability technologies, an accurate fire prediction capability remains paramount for credible vulnerability assessments. Physics based modeling of the hydrodynamic ram (HRAM) fluid deposition process is a key component of such capability, wherein capturing the first instance of fluid spurt, referred to herein as shallow jet spurts, is a core focus. Such pre-spurts as they have been formerly identified have only been witnessed sporadically in HRAM spurt experiments. In this work, ALE3D, a first-principles multi-physics code was employed to model the shallow jet spurt phenomenon with spherical projectiles impacting water-filled tanks faced with aluminum panels, such that the underlying physics and sensitivities could be explored. Development and verification of the 2D axisymmetric model is described relative to trends observed in a prior experimental campaign. Results from the verified model suggest shallow jet spurts have at least a quadratic sensitivity to the fundamental vibrational mode of the impact plate across impact velocities 610–1829 m/s (2000–6000 ft/s). It is further explained how shallow jet spurts are arrested for impacts at the two extremes of plate rigidity. This research constitutes the first fluid-structure modeling of shallow jet spurts which future three-dimensional analyses will expound upon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LOX/GOX sensitivity of fluoroelastomers

The effect of formulation components and the addition of fire retardants on the impact sensitivity of Viton B fluoroelastomer in liquid oxygen was studied with the objective of developing a procedure for reliably reducing this sensitivity. Component evaluation, carried out on more than 40 combinations of components and cure cycles, showed that almost all the standard formulation agents, including carbon, MgO, Diak-3, and PbO2, will sensitize the Viton stock either singly or in combinations, some combinations being much more sensitive than others. Cure and postcure treatments usually reduced the sensitivity of a given formulation, often dramatically, but no formulated Viton was as insensitive as the pure Viton B stock. Coating formulated Viton with a thin layer of pure Viton gave some indication of reduced sensitivity, but additional tests are needed. It is concluded that sensitivity in formulated Viton arises from a variety of sources, some physical and some chemical in origin. Elemental analyses for all the formulated Vitons are reported as are the results of a literature search on the subject of LOX impact sensitivity.

Kirshen, N.↗