Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of Inductive Coil Geometry on the Operating Characteristics of an Inductive Pulsed Plasma Thruster

Operational characteristics of two separate inductive thrusters with conical theta pinch coils of different cone angles are explored through thrust stand measurements and time- integrated, unfiltered photography. Trends in impulse bit measurements indicate that, in the present experimental configuration, the thruster with the inductive coil possessing a smaller cone angle produced larger values of thrust, in apparent contradiction to results of a previous thruster acceleration model. Areas of greater light intensity in photographs of thruster operation are assumed to qualitatively represent locations of increased current density. Light intensity is generally greater in images of the thruster with the smaller cone angle when compared to those of the thruster with the larger half cone angle for the same operating conditions. The intensity generally decreases in both thrusters for decreasing mass flow rate and capacitor voltage. The location of brightest light intensity shifts upstream for decreasing mass flow rate of propellant and downstream for decreasing applied voltage. Recognizing that there typically exists an optimum ratio of applied electric field to gas pressure with respect to breakdown efficiency, this result may indicate that the optimum ratio was not achieved uniformly over the coil face, leading to non-uniform and incomplete current sheet formation in violation of the model assumption of immediate formation where all the injected propellant is contained in a magnetically-impermeable current sheet.

Hallock, Ashley K.↗

Induction heating using induction coils in series-parallel circuits

A part is inductively heated by multiple, self-regulating induction coil circuits having susceptors, coupled together in parallel and in series with an AC power supply. Each of the circuits includes a tuning capacitor that tunes the circuit to resonate at the frequency of AC power supply.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Circular, Square, Single, and Multi-layer Induction Coils for Electromagnetic Priming Using Inductance Estimates

Special induction coils used for electro magnetic priming of ceramic foam filters in liquid metal filtration have been designed using a combination of analytical and finite element modeling. Relatively simple empirical equations published by Wheeler in 1928 and 1982 have been used during the design process. The equations were found to accurately predict the z-component of the magnetic flux densities of both single- and multi-layer coils as verified both experimentally and by using COMSOL{sup ®} 5.1 multiphysics simulations.

36 MATERIALS SCIENCE↗

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Simultaneous Insight into Dissolution and Aggregation of Metal Sulfide Nanoparticles through Single-Particle Inductively Coupled Plasma Mass Spectrometry

Nanoparticles (NPs) and their colloidal aggregates are ubiquitous and play important roles in the transport and release of metals. Knowledge of their dissolution rates and aggregation behavior in solution are crucial for better prediction of their fate in biogeochemical cycling, ecotoxicity, and environmental remediation. There are however significant technical challenges to accurately obtain such information as a result of the heterogeneity and highly dynamic transformation exhibited by NPs, particularly at relatively low particle concentrations in aqueous systems. Here, we quantitatively examine the simultaneous dissolution and aggregation behavior of metal sulfide NPs using single-particle inductively coupled plasma mass spectrometry (spICP–MS). We focus on nickel sulfide (NiS), with additional data presented for copper sulfide (CuS) and cobalt sulfide (CoS). The kinetics of metal release (dissolution and disaggregation) of NiS was fastest under strongly oxidizing conditions (from 0.04 to >3 min –1 with H 2 O 2 ) and were slower under near-neutral (HEPES buffer/H 2 O) and acidic (1 mM HNO 3 ) conditions (≤0.006 min –1 ). Metal release kinetics in HNO 3 was not faster than in H 2 O or HEPES, suggesting that the solution pH has an influence over both the dissolution kinetics of individual particles and the NP aggregation states, which in combination affect metal release rates over time. Between different metal sulfides, the measured metal release rates were largely consistent with predictions based on the crystallinity, solubility products, and specific surface areas of the NPs, following an order of CoS > NiS > CuS. Here, the spICP–MS approach described here can be easily applied to the characterization of metal release and aggregation of other NPs at low concentrations (~10 5 particles/mL) typically found in natural environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid matrix transformation and tracer addition using molten ammonium bifluoride salt as a sample preparation method for laser ablation inductively coupled plasma mass spectrometry

Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Finally, looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standard

47 OTHER INSTRUMENTATION↗

Transients using low-high pulsed power in inductively coupled plasmas

Pulsed inductively coupled plasmas (ICPs) are widely deployed in the fabrication of semi-conductor devices. Pulse repetition frequencies (PRFs) of up to tens of kHz are commonly used during plasma etching for the high power densities they generate during the pulse-on period, and for their unique chemistries during the pulse-off period. The use of highly attaching halogen gases produces low electron densities during the pulse-off period, and these low density can result in instabilities, E-H transitions and ignition delays when applying power on the next pulse. To mitigate these possibilities, a low-level power environment could be maintained during “pulse-off” to moderate the minimum plasma density, therefore reducing ignition delays and enhancing plasma stability. In this work, ICPs sustained by 5 kHz pulsed power using Ar/Cl 2 mixtures at 20 mTorr were computationally investigated. For these conditions, the computed electron temperature (T e ) reaches a quasi-steady state during both the high- and low-power excitation. The model predicts that within the electromagnetic skin-depth, T e spikes to a high value during a low-to-high power modulation, and to a low value during a high-to-low power modulation. At the same time, a few cm above the substrate, there is little modulation in T e , as electron power convected from the skin depth disperses in traversing the reactor. Finally, the positive and negative spikes, and convection of transients across the reactors, are functions of power ramping time and gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Induction of genomic instability in TK6 human lymphoblasts exposed to 137Cs gamma radiation: comparison to the induction by exposure to accelerated 56Fe particles

The induction of genomic instability in TK6 human lymphoblasts by exposure to (137)Cs gamma radiation was investigated by measuring the frequency and characteristics of unstable clones isolated approximately 36 generations after exposure. Clones surviving irradiation and control clones were analyzed for 17 characteristics including chromosomal aberrations, growth defects, alterations in response to a second irradiation, and mutant frequencies at the thymidine kinase and Na(+)/K(+) ATPase loci. Putative unstable clones were defined as those that exhibited a significant alteration in one or more characteristics compared to the controls. The frequency and characteristics of the unstable clones were compared in clones exposed to (137)Cs gamma rays or (56)Fe particles. The majority of the unstable clones isolated after exposure to either gamma rays or (56)Fe particles exhibited chromosomal instability. Alterations in growth characteristics, radiation response and mutant frequencies occurred much less often than cytogenetic alterations in these unstable clones. The frequency and complexity of the unstable clones were greater after exposure to (56)Fe particles than to gamma rays. Unstable clones that survived 36 generations after exposure to gamma rays exhibited increases in the incidence of dicentric chromosomes but not of chromatid breaks, whereas unstable clones that survived 36 generations after exposure to (56)Fe particles exhibited increases in both chromatid and chromosome aberrations.

Non-NASA Center↗

New measurement of the 238 U decay constant with inductively coupled plasma mass spectrometry [New Measurement of the U-238 Decay Constant with Inductively Coupled Plasma Mass Spectrometry]

The 238 U decay constant (λ U-238 ) is fundamental to radioisotope-based chronometry in the Earth and planetary sciences, yet only a single published λ U-238 value (Jaffey et al. in Phys Rev C 4(5):1889–1906, 1971) is widely applied. We have determined λ U-238 via the novel approach of measuring of 234 Th ingrowth in high-purity 238U solutions, using isotope dilution mass spectrometry (ID-MS). The 234 Th decay constant (λ Th-234 ) was measured via decay counting with high-purity Ge (HPGe) $\gamma$ detectors. Preliminary results for λ U-238 agree with the value determined by $a$-counting [1] within the elevated uncertainty of 0.462% (k = 2). Ongoing efforts to reproduce λ U-238 with reduced experimental uncertainties will inform future conclusions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Heating system with induction power supply and electromagnetic acoustic transducer with induction power supply

A system for heating a fluid and an electromagnetic acoustic transducer EMAT system is provided. Both systems have a drive circuit. The amount of heat and the amplitude (and acceleration) of the vibrations is respectively controllable by controlling an input to a terminal of a switch. The heating system comprises a porous graphite foam conductor which is exposed to an electromagnetic field generated by an oscillating circuit. When exposed, the foam conductor conducts induced electric current which heats the same and a fluid in contact with the conductor. The EMAT system comprises at least one magnet configured to generate a static magnetic field, an oscillating circuit and a working element. The working element, when exposed to the static magnetic field and the electromagnetic field produced by the oscillating circuit, vibrates against a load. The vibrations dry the load.

Kisner, Roger A.↗

Introduction of a Variable Inductance Transformer for the Design of Resonant Power Converters

Magnetic integration is a hot topic in power electronics that concerns the use of a transformer’s leakage and magnetizing inductances purposefully in isolated power electronic converters, thereby giving the opportunity to save the cost and footprint of any additional inductor. This is of prime interest, especially in CLLLC resonant converters which require up to three inductors. For a complete integration of these inductances, the concept of a variable inductance transformer (VIT) is introduced in this thesis. A VIT is an adaptive magnetic structure that facilitates an easy adjustment of both magnetizing and leakage inductances to meet their desired values. However, for a more promising design, an accurate estimation of these inductances is necessary. While the evaluation of magnetizing inductance is quite straightforward, the calculation of leakage inductance is rather convoluted, because the leakage inductance is influenced by both the winding layout and the operating frequency. In this thesis, three new semi-analytical methods for calculating the frequency-independent leakage inductance, and a novel semi-analytical method for evaluating the frequency-dependent leakage inductance are proposed. These methods can calculate the respective leakage inductances of a VIT within an outstanding ±5% uncertainty. Finally, a bidirectional CLLLC resonant dc-dc converter is investigated for the constant current constant voltage (CCCV) charging of the next-generation 900 V traction battery of an electric vehicle. A new voltage gain equation is derived for designing the CLLLC resonant tank, and a small-signal model is presented for designing the variable-frequency feedback controller. Furthermore, a new methodology to design a VIT is developed to overcome the challenges associated with small coupling coefficients and guarantee a complete magnetic integration of the tank inductances. All theoretical results presented herein are verified through simulations and experiments performed on hardware prototypes designed in the lab.

24 POWER TRANSMISSION AND DISTRIBUTION↗