At least 37 records · Page 2

Thermographic Inspection of Metallic Honeycomb Sandwich Structures

The X-33/VentureStar has a Thermal Protection System (TPS) consisting mainly of brazed metallic honeycomb sandwich structures. Inspection of these structures is changing as a result of the extremely thin (less than 200 microns) skins, the small critical defect size (less than 2 mm long by 100 microns wide) and the large number (more than 1000) of parts to be inspected. Pulsed Infrared Thermography has been determined to be the most appropriate inspection method for manufacturing inspection based on performance comparison with other methods, cost, schedule and other factors. The results of the assessment of the different methods will be summarized and data on the performance of the final production inspection system will be given. Finite difference thermal methods have been used to model the whole inspection process. Details of correlation between the models and experimental data will be given and data on the use of pulsed infrared thermography on other metallic honeycomb sandwich structures will be given.

Taylor, John O.↗

Infrared On-Orbit RCC Inspection With the EVA IR Camera: Development of Flight Hardware From a COTS System

In November 2004, NASA's Space Shuttle Program approved the development of the Extravehicular (EVA) Infrared (IR) Camera to test the application of infrared thermography to on-orbit reinforced carbon-carbon (RCC) damage detection. A multi-center team composed of members from NASA's Johnson Space Center (JSC), Langley Research Center (LaRC), and Goddard Space Flight Center (GSFC) was formed to develop the camera system and plan a flight test. The initial development schedule called for the delivery of the system in time to support STS-115 in late 2005. At the request of Shuttle Program managers and the flight crews, the team accelerated its schedule and delivered a certified EVA IR Camera system in time to support STS-114 in July 2005 as a contingency. The development of the camera system, led by LaRC, was based on the Commercial-Off-the-Shelf (COTS) FLIR S65 handheld infrared camera. An assessment of the S65 system in regards to space-flight operation was critical to the project. This paper discusses the space-flight assessment and describes the significant modifications required for EVA use by the astronaut crew. The on-orbit inspection technique will be demonstrated during the third EVA of STS-121 in September 2005 by imaging damaged RCC samples mounted in a box in the Shuttle's cargo bay.

Gazanik, Michael↗

Thermographic Qualification of Graphite/Epoxy Instrumentation Racks

A nondestructive evaluation method is desired for ensuring the 'as manufactured' and 'post service' quality of graphite/epoxy instrumentation rack shells. The damage tolerance and geometry of the racks dictate that the evaluation method be capable of identifying defects, as small as 0.25 inch 2 in area, over large acreage regions, tight compound radii and thickness transition zones. The primary defects of interest include voids, inclusions, delaminations and porosity. The potential for an infrared thermographic inspection to replace ultrasonic testing, for qualifying the racks as 'defect free' is under investigation. The inspection process is validated by evaluating defect standard panels built to the same specifications as the racks, except for the insertion of artificial fabricated defects. The artificial defects are designed to match those which are most prevalent in the actual instrumentation racks. A target defect area of 0.0625 inch 2 (a square with 0.25 inch on a side) was chosen for the defect standard panels to ensure the ability to find all defects of the critical (0.25 inch squared) size.

Walker, James L.↗

Thermographic Analysis of Composite Cobonds on the X-33

The methods utilized to perform an infrared thermography inspection of the bondline of structural reinforcing caps on X-33 liquid hydrogen (LH2) tank during the manufacture are described in this presentation. A total of thirty-six caps were bonded to the tank using a wet cobond process with vacuum bagging and low temperature curing. The thermal map of each bondline was acquired through the vacuum bag by applying heat to the cap and then viewing it during cool down. Poorly bonded regions, or voids, were characterized by localized hot spots in the thermal image. These regions were marked on the tank by referring to a live thermal image, then hand massaged in an attempt to remove the entrapped air. The cap was then reinspected and, if it was determined that the entrapped air could not be removed, the cap was removed and the adhesive cleaned away before it cured. Measures were then taken to better match the surface of the cap to the tank and the process repeated. After the bondline had cured sufficiently to allow vacuum bag removal, a "flash heating" thermographic Investigation was performed to verify that the cap had bonded properly to the tank. Any regions that had opened up after the preliminary inspection were marked and filled by drilling small holes in the cap and injecting resin. A final inspection was then performed to ensure the quality of the bondline.

Russell, Samual S.↗

Infrared Contrast Analysis Technique for Flash Thermography Nondestructive Evaluation

The paper deals with the infrared flash thermography inspection to detect and analyze delamination-like anomalies in nonmetallic materials. It provides information on an IR Contrast technique that involves extracting normalized contrast verses time evolutions from the flash thermography infrared video data. The paper provides the analytical model used in the simulation of infrared image contrast. The contrast evolution simulation is achieved through calibration on measured contrast evolutions from many flat bottom holes in the subject material. The paper also provides formulas to calculate values of the thermal measurement features from the measured contrast evolution curve. Many thermal measurement features of the contrast evolution that relate to the anomaly characteristics are calculated. The measurement features and the contrast simulation are used to evaluate flash thermography inspection data in order to characterize the delamination-like anomalies. In addition, the contrast evolution prediction is matched to the measured anomaly contrast evolution to provide an assessment of the anomaly depth and width in terms of depth and diameter of the corresponding equivalent flat-bottom hole (EFBH) or equivalent uniform gap (EUG). The paper provides anomaly edge detection technique called the half-max technique which is also used to estimate width of an indication. The EFBH/EUG and half-max width estimations are used to assess anomaly size. The paper also provides some information on the "IR Contrast" software application, half-max technique and IR Contrast feature imaging application, which are based on models provided in this paper.

Koshti, Ajay↗

Defect Characterization in a Thin Walled Composite RP-1 Tank: A Case Study

A full scale thin walled composite tank, designed and fabricated for the storage of pressurized RP- I rocket fuel, was fully inspected with digital infrared thermography (IR) during assembly and prior to proof testing. The tank featured a "pill capsule" design with the equatorial bondline being overwrapped on both the inner and outer surfaces. A composite skirt was bonded to the aft dome of the tank to serve as a structural support when the tank was stood on end in service. Numerous anomalies were detected and mapped prior to proof testing, some along bondlines and some scattered throughout the acreage. After the tank was intentionally burst, coupons were cut from the regions including thermographic anomalies. These coupons were again inspected thermographically to document the growth of any indications due to proof testing. Ultrasonic inspections (UT) were also performed on the coupons for comparison to thermography. Several coupons were dissected and micrographed. Relationships between IR and UT indications and the physical nature of the dissected material are presented.

Langsing, Matthew D.↗