Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure

OCPP protocol manages the interaction between the EVSE and its respective back-end communication network. It plays a pivotal role in both error reporting and troubleshooting, carried out primarily through the CSMS. OCPP defines both standard error codes and a flexible framework for creating and communicating custom error codes. The OCPI protocol orchestrates the communication between different backhaul communication networks, incorporating the exchange of error codes. These error codes are instrumental in pinpointing and rectifying issues that can surface prior to, during, or after charging operations, fortifying the reliability and resilience of the EV charging infrastructure. The flexibility offered by the OCPP and OCPI frameworks through the introduction of custom error codes also creates its own set of challenges. While the integration of custom error codes allows for enhanced granularity, it also introduces inconsistencies and fragmentation within the overarching diagnostic reporting system. To address the challenges with custom error codes this report proposes a set of Minimum Required Error Codes (MRECs) for streamlined error reporting, interpretability, and diagnostics. Recommendations in this report are based on independent analysis of custom error codes from multiple stakeholders within the EV charging ecosystem. For better error resolution, this report also assigns one or more entities responsible for the resolution of every mentioned error code. Finally, a functional classification for each mentioned error code is also identified to describe the nature of the error. In summary, the purpose of this document is to simplify the troubleshooting process and increase charging reliability for all EV users. This report serves as a recommendation for industry stakeholders, encouraging a unified methodology to define, transmit, and interpret common error codes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Berkeley Efficient Long-Read to Long-Read Aligner and Overlapper (DiBELLA) v1.0.0

We present a parallel algorithm and scalable implementation for genome analysis, specifically the problem of finding overlaps and alignments for data from "third generation" long read sequencers. While long sequences of DNA offer enormous advantages for biological analysis and insight, current long read sequencing instruments have high error rates and therefore require different approaches to analysis than their short read counterparts. Our work focuses on an efficient distributed-memory parallelization of an accurate single-node algorithm for overlapping and aligning long reads. We achieve scalability of this irregular algorithm by addressing the competing issues of increasing parallelism, minimizing communication, constraining the memory footprint, and ensuring good load balance. The resulting application, DiBELLA, is the first distributed memory overlapper and aligner specifically designed for long reads and parallel scalability.

Ellis, Marquita↗

Radar Derived Rainfall and Rain Gauge Measurements at SRS

Over the years rainfall data for the Savannah River Site has been obtained from ground level measurements made by rain gauges. These instruments have inherent errors or biases that can impact the measured rainfall totals but are assumed as ground truth for most climatological and weather applications. With the development of weather radar technologies, various methods to derive rainfall totals from radar reflectivity values have been developed and have continued to improve. The Z-R relationship, which uses an exponential relationship to estimate rainfall rate based on radar reflectivity values, provides estimates of rainfall amounts (Z-R Level III) for locations within the radar’s detection range. The recently developed Multi-Radar Multi-Sensor (MRMS) dataset combines reflectivity-based estimates using the Z-R relationship with a network of gauges and other rainfall estimates to produce a refined set of precipitation estimates for each grid point within its domain. Comparisons were done between gauge observations and radar estimates for various SRS locations to assess whether radar derived estimates are representative of rainfall measurements at the site. Results obtained show good agreement between radar derived amounts and ground measurements, with MRMS showing stronger correlations and lower spread than Z-R Level III estimates. Outliers and errors observed appear to be related to hydrometeor classification schemes. In general, MRMS proved to provide sufficiently representative estimates of daily rainfall amounts to replace existing SRS rain gauge measurements.

54 ENVIRONMENTAL SCIENCES↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Fidelity of Earth's Terrestrial and Aquatic Ecosystems

The Surface Biology and Geology (SBG) investigation will create global maps of spectral surface reflectance and emissivity at a cadence of 16 days or better, with coverage to address global questions about Earth's geology, cryosphere and ecosystems. The revolutionary potential poses a commensurate challenge: creating contiguous maps free from regional biases induced by atmosphere, observation geometry, or inversion error. This will require an accurate calibration with precise knowledge of each channel's spectral response. In this work, we quantify the impact of spectral calibration on SBG's aquatic and terrestrial ecosystem objectives. We find that contemporary algorithms for ecosystem trait retrieval demand more accurate spectral calibration than historical missions. Errors due to drift or spatial nonuniformity in the wavelength calibration that have previously been considered acceptable can cause systematic errors larger than the instrument noise and of the same order as the variability SBG aims to measure. Moreover, their impact on atmospheric correction can induce climate-dependent systematic errors that thwart comparisons between ecosystems. These results underscore the importance of spectral response accuracy in SBG mission design.

54 ENVIRONMENTAL SCIENCES↗

Trends in Downwelling Longwave Radiance Over the Southern Great Plains

Downwelling longwave radiation is an important part of the surface energy budget. Spectral trends in the downwelling longwave radiance (DLR) provide insight into the radiative drivers of climate change. In this research, we process and analyze a 23-year DLR record measured by the Atmospheric Emitted Radiance Interferometer (AERI) at the U.S. Department of Energy Atmospheric Radiation Program Southern Great Plains (SGP) site. Two AERIs were deployed at SGP with an overlapping observation period of about 10 years, which allows us to examine the consistency and accuracy of the measurements and to account for discrepancies between them due to errors associated with the instruments themselves. We then analyzed the all-sky radiance trends in DLR, which are associated with the surface warming trend at SGP during this same period and also the complex changes in meteorological conditions. For instance, the observed radiance in the CO2 absorption band follows closely the near-surface air temperature variations. The significant positive radiance trends in weak absorption channels, such as in the wings of the CO 2 band and in the weak absorption channels in the H 2 O vibration-rotational band, show earlier detectability of climate change. The magnitude of the radiance trend uncertainty in the DLR record mainly results from internal climate variability rather than from measurement error, which highlights the importance of continuing the DLR spectral measurements to unambiguously detect and attribute climate change.

54 ENVIRONMENTAL SCIENCES↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

CPC data from TAMU TRACER campaign in the Houston, TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.3 LPM is directed to the CPC. To correct the data for particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate total particle loss through the inlet for every SMPS scan at a single deployment location. Second, the CPC data was corrected for particle losses using the average of the total losses per scan. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. An additional flatline correction of 14% was applied to all CPC data based on laboratory calibration prior to and after the campaign. In laboratory calibrations, we identified that for the same sample of air the field CPC (GRIMM Model 5.403 CPC) undercounted the total concentration of particles by 14% compared to the ground truth laboratory CPC (TSI Model 3750). This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Measurements of the z > 5 Lyman-α forest flux autocorrelation functions from the extended XQR-30 data set

We present the first observational measurements of the Lyman-α (Ly α) forest flux autocorrelation functions in ten redshift bins from 5.1 ≤ z ≤ 6.0. We use a sample of 35 quasar sightlines at z > 5.7 from the extended XQR-30 data set; these data have signal-to-noise ratios of >20 per spectral pixel. We carefully account for systematic errors in continuum reconstruction, instrumentation, and contamination by damped Ly α systems. With these measurements, we introduce software tools to generate autocorrelation function measurements from any simulation. Our measurements of the smallest bin of the autocorrelation function increase with redshift when normalizing by the mean flux, $\langle{F}\rangle$. This increase may come from decreasing $\langle{F}\rangle$ or increasing mean free path of hydrogen-ionizing photons, λmfp. Recent work has shown that the autocorrelation function from simulations at z > 5 is sensitive to λmfp, a quantity that contains vital information on the ending of reionization. For an initial comparison, we show our autocorrelation measurements with simulation models for recently measured λmfp values and find good agreements. Further work in modelling and understanding the covariance matrices of the data is necessary to get robust measurements of λmfp from this data.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal 1D Ly α forest power spectrum estimation – III. DESI early data

ABSTRACT The 1D power spectrum P1D of the Ly α forest provides important information about cosmological and astrophysical parameters, including constraints on warm dark matter models, the sum of the masses of the three neutrino species, and the thermal state of the intergalactic medium. We present the first measurement of P1D with the quadratic maximum likelihood estimator (QMLE) from the Dark Energy Spectroscopic Instrument (DESI) survey early data sample. This early sample of 54 600 quasars is already comparable in size to the largest previous studies, and we conduct a thorough investigation of numerous instrumental and analysis systematic errors to evaluate their impact on DESI data with QMLE. We demonstrate the excellent performance of the spectroscopic pipeline noise estimation and the impressive accuracy of the spectrograph resolution matrix with 2D image simulations of raw DESI images that we processed with the DESI spectroscopic pipeline. We also study metal line contamination and noise calibration systematics with quasar spectra on the red side of the Ly α emission line. In a companion paper, we present a similar analysis based on the Fast Fourier Transform estimate of the power spectrum. We conclude with a comparison of these two approaches and discuss the key sources of systematic error that we need to address with the upcoming DESI Year 1 analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Chatbots can guide experimentalists to avoid many common mistakes in measuring fluorescence spectra

The concepts of fluorescence spectroscopy are well established, yet the experimental collection of a spectrum is susceptible to a range of errors. A recent study showed that chatbots – derived from substantial advances in artificial intelligence – can provide practical assistance to the experimentalist during collection of absorption spectra and thereby achieve improved quality. Fluorescence, while the complement of absorption, is prone to a far richer array of experimental errors encompassing environmental factors, instrumental settings, and experimentalist mistakes. Here, 10 chatbots (ChatGPT 5, Gemini 2.5 Pro, Microsoft Copilot, Meta AI Llama 4, Claude Sonnet 4.5, X.ai Grok 4, Perplexity Pro, DeepSeek V3.1, Z.ai GLM-4.6, and KIMI K2) have been evaluated for the suitability in providing quality-improvement advice to the experimentalist during acquisition of fluorescence spectra. Significant opportunities for practical assistance are noted, although intervention by a domain expert is often required. Here, if combined with image recognition and/or signal processing, chatbots embedded in instruments may enable real-time guidance during fluorescence data acquisition.

Artificial intelligence↗

On the Viability of Video Imaging in Leak Rate Quantification: A Theoretical Error Analysis

Optical gas imaging through multispectral cameras is a promising technique for mitigation of methane emissions through localization and quantification of emissions sources. While more advanced cameras developed in recent years have led to lower uncertainties in measuring gas concentrations, a systematic analysis of the uncertainties associated with leak rate estimation have been overlooked. We present a systematic categorization of the involved uncertainties with a focus on a theoretical analysis of projection uncertainties that are inherent to this technique. The projection uncertainties are then quantified using Large Eddy Simulation experiments of a point source release into the atmosphere. Our results show that while projection uncertainties are typically about 5% of the emission rate, low acquisition times and observation of the gas plume at small distances from the emission source (<10 m) can amount to errors of about 20%. Further, we found that acquisition times on the order of tens of seconds are sufficient to significantly reduce (>50%) the projection uncertainties. These findings suggest robust procedures on how to reduce projection uncertainties, however, a balance between other sources of uncertainty due to operational conditions and the employed instrumentation are required to outline more practical guidelines.

47 OTHER INSTRUMENTATION↗

BEYONDPLANCK XIII. Intensity foreground sampling, degeneracies, and priors

We present the intensity foreground algorithms and model employed within the BEYONDPLANCK analysis framework. The BEYONDPLANCK analysis is aimed at integrating component separation and instrumental parameter sampling within a global framework, leading to complete end-to-end error propagation in the Planck Low Frequency Instrument (LFI) data analysis. Given the scope of the BEYONDPLANCK analysis, a limited set of data is included in the component separation process, leading to foreground parameter degeneracies. In order to properly constrain the Galactic foreground parameters, we improve upon the previous Commander component separation implementation by adding a suite of algorithmic techniques. These algorithms are designed to improve the stability and computational efficiency for weakly constrained posterior distributions. These are: (1) joint foreground spectral parameter and amplitude sampling, building on ideas from MIRAMARE; (2) component-based monopole determination; (3) joint spectral parameter and monopole sampling; and (4) application of informative spatial priors for component amplitude maps. We find that the only spectral parameter with a significant signal-to-noise ratio using the current BEYONDPLANCK data set is the peak frequency of the anomalous microwave emission component, for which we find $ν$ p = 25.3 ± 0.5 GHz; all others must be constrained through external priors. Future works will be aimed at integrating many more data sets into this analysis, both map and time-ordered based, thereby gradually eliminating the currently observed degeneracies in a controlled manner with respect to both instrumental systematic effects and astrophysical degeneracies. When this happens, the simple LFI-oriented data model employed in the current work will need to be generalized to account for both a richer astrophysical model and additional instrumental effects. This work will be organized within the Open Science-based COSMOGLOBE community effort.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

X-ray continuum spectroscopy of inertial confinement fusion implosions at the National Ignition Facility

A methodology for measuring x-ray continuum spectra of inertial confinement fusion (ICF) implosions is described. The method relies on the use of ConSpec, a high-throughput spectrometer using a highly annealed pyrolytic graphite crystal , which measures the spectra in the ≃20–30 keV range. Due to its conical shape, the crystal is sagittally focusing a Bragg-reflected x-ray spectrum into a line, which enhances the recorded x-ray emission signal above the high neutron-induced background accompanying ICF implosions at the National Ignition Facility. To improve the overall measurement accuracy, the sensitivity of the spectrometer measured in an off-line x-ray laboratory setting was revised. The error analysis was expanded to include the accuracy of the off-line measurements, the effect of the neutron-induced background, as well as the influence of possible errors in alignment of the instrument to the ICF target. Here we demonstrate how the improved methodology is applied in the analysis of ConSpec data with examples of a relatively low-neutron-yield implosion using a tritium–hydrogen–deuterium mix as a fuel and a high-yield deuterium–tritium (DT) implosion producing high level of the background. In both cases, the shape of the measured spectrum agrees with the exponentially decaying spectral shape of bremsstrahlung emission to within ±10%. In the case of the high-yield DT experiment, non-monotonic deviations slightly exceeding the measurement uncertainties are observed and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗