Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS - AIR-SPEED RECORDERS - WIESELSBERGER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tropical SNO Comparisons of AIRS and CrIS Calibration for Windows

AIRS (Atmospheric Infrared Sounder) on EOS (Earth Observing System)-Aqua and CrIS (Cross-track Infrared Sounder) on Suomi NPP (National Polar-orbiting Partnership) are two hyperspectral infrared sounders with similar capabilities and orbits, so there is a great opportunity to compare their absolute calibration while they are both in orbit. This insures that long-term climate record can be created by concatenating the two instrument records. There are significant differences in instrument architecture which may lead to subtle differences and complicate attempts to combine the records. We use Tropical Simultaneous Nadir Observations (TSNOs), cases where both instruments are looking nearly at the same place at the same time, to explore the differences. Due to the presence of cold clouds and clear hot desert surface, the data cover a brightness temperature range from 190 degrees Kelvin to 340 degrees Kelvin. We concentrate on the differences between the mean of the two instruments using atmospheric window channels as function of brightness temperature in 20-degree-Kelvin wide bins. With the currently available AIRS and CrIS official calibrated data, radiometric differences as large as 0.3 degrees Kelvin are seen at the extreme temperatures. These differences may be reduced in future releases of the AIRS and CrIS calibration.

CrIS↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗

The 19 mm data recorders similarities and differences

Confusion over the use of non-video 19 mm data recorders is becoming more pronounced as we enter the world of high performance computing. This paper addresses the following: the differences between ID-1, ID-2, MIL-STD-2179 and DD-2; what the proper machine is for various applications; how the machine can be integrated into an environment; and any misconceptions there might be about 19 mm tape recorders. DD-2 and 19 mm instrumentation recorders have missions for which each is well designed. While the differences may appear subtle, understanding the difference between the two is the key to picking the right recorder for a particular application.

Atkinson, Steve↗

The Synchronization of NACA Flight Records

A method is described for synchronizing the different instrument records taken during flight testing. This method has been in use for sometime at the Langley Memorial Aeronautical Laboratory and has proved very valuable in connection with the study of controllability and other complicated problems of flight.

Brown, W G↗

Drought and Deluge: the Recurrence of Hydroclimate Extremes During the Past 600 Years in Eastern Australia’s Natural Resource Management (NRM) Clusters

Recent extremes of flood and drought across Australia have raised questions about the recurrence of such rare events and highlighted the importance of understanding multi-decadal climate variability. However, instrumental records over the past century are too short to adequately characterise climate variability on multi-decadal and longer timescales or robustly determine extreme event frequencies and their duration. Palaeoclimate reconstructions can provide much-needed information to help address this problem. Here, we use the 600-year hydroclimate record captured in the eastern Australian and New Zealand Drought Atlas (ANZDA) to analyse drought and pluvial frequency trends for East Australian Natural Resource Management (NRM) clusters. This partitioning of the drought atlas grid points into recognised biophysical areas (i.e. NRM clusters) revealed their differences and similarities in drought intensity and pluvial events over time. We find sustained multi-decadal periods of a wet–dry geographic 'seesaw' between eastern to central and southern NRMs (e.g. 1550–1600 CE and 1700–1750 CE). In contrast, other periods reveal spatially consistent wetting (e.g. 1500–1550 CE) or drying (e.g. 1750–1800 CE). Emerging hot spot analysis further shows that some areas that appear naturally buffered from severe drought during the instrumental period have a greater exposure risk when the longer 600-year record is considered. These findings are particularly relevant to management plans when dealing with the impacts of climate extremes developed at regional scales. Our results demonstrate that integrating and extending instrumental records with palaeoclimate datasets will become increasingly important for developing robust and locally specific extreme event frequency information for managing water resources.

Australian hydroclimate↗

Evaluation of Gust and Draft Velocities from Flights of P-61c Airplanes within Thunderstorms. II - July 9, 1946 to July 11, 1946 at Orlando, Florida: July 9, 1946 to July 11, 1946 at Orlando, Florida - II

The results obtained from an evaluation for gust and draft velocities of acceleration and airspeed-altitude records taken by NACA recording instruments installed in P-61c airplanes participating in thunderstorm flights 6, 7, and 8 of July 9, 1946, July 10, 1946, and July 11, 1946, respectively, are presented herein. These data are summarized in tables I and II. In accordance with a recent discussion with a member of the U.S. Weather Bureau staff, the tabulated results for the present flight include in addition to data of the type presented in reference 1, the initial heading of the airplane for each traverse, the pressure altitude at the start of each traverse in increments of 500 feet, and the gust gradient distance when it could be evaluated. The cloud entry and exit times for the present data were taken from motion-picture records of the pilot's instrument panels whenever such records were available while the length fo the traverses in seconds and feet was taken from the airspeed-altitude records. In many cases, however, poor agreement is indicated between the duration of the cloud traverses as obtained from the motion-picture records and from the airspeed-altitude records. This result is believed to be due to camera stoppages, inaccurate spring mechanisms of the clocks, and loss of motion-picture record in exposure or development. With reference to the evaluation of gust data, the nominal threshold was about 2 feet per second. In making gust counts to this threshold, some gusts below that threshold have been included due to limitations of the procedure used. Thus, it will be noted that in some instances gust counts are given in table I although now corresponding gust velocities are listed.

Tolefson, Harold B.↗

Harmonic distortion analyzer speeds setup of magnetic tape recorders

Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

Tinari, D. F.↗

Coastal Sea Level Observations Record the Twentieth-Century Enhancement of Decadal Climate Variability

Changes in the amplitude of decadal climate variability over the twentieth century have been noted, with most evidence derived from tropical Pacific sea surface temperature records. However, the length, spatial coverage, and stability of most instrumental records are insufficient to robustly identify such nonstationarity, or resolve its global spatial structure. Here, it is found that the long-term, stable, observing platform provided by tide gauges reveals a dramatic increase in the amplitude and spatial coherence of decadal (11–14-yr period) coastal sea level (ζ) variability between 1960 and 2000. During this epoch, western North American ζ was approximately out of phase with ζ in Sydney, Australia, and led northeastern U.S. ζ by approximately 1–2 years. The amplitude and timing of changes in decadal ζ variability in these regions are consistent with changes in atmospheric variability. Specifically, central equatorial Pacific wind stress and Labrador Sea heat flux are highly coherent and exhibit contemporaneous, order-of-magnitude increases in decadal power. These statistical relationships have a mechanistic underpinning: Along the western North American coastline, equatorial winds are known to drive rapidly propagating ζ signals along equatorial and coastal waveguides, while a 1–2-yr lag between Labrador Sea heat fluxes and northeastern United States ζ is consistent with a remotely forced, buoyancy-driven, mechanism. Tide gauges thus provide strong independent support for an increase in interbasin coherence on decadal time scales over the second half of the twentieth century, with implications for both the interpretation and prediction of climate and sea level variability.

54 ENVIRONMENTAL SCIENCES↗

Mark 3 wideband digital recorder in perspective

The tape recorder used for the Mark 3 data acquisition and processing system is compared with earlier very long baseline interferometry recorders. Wideband 33-1/3 kbpi digital channel characteristics of instrumentation recorders and of a modern video cassette recorder are illustrated. Factors which influenced selection of the three major commercial components (transport, heads, and tape) are discussed. A brief functional description and the reasons for development of efficient signal electronics and necessary auxiliary control electronics are given. The design and operation of a digital bit synchronizer is illustrated as an example of the high degree of simplicity achieved.

Hinteregger, H. F.↗

Late Holocene glacier and climate fluctuations in the Mackenzie and Selwyn mountain ranges, northwestern Canada

Over the last century, northwestern Canada experienced some of the highest rates of tropospheric warming globally, which caused glaciers in the region to rapidly retreat. Our study seeks to extend the record of glacier fluctuations and assess climate drivers prior to the instrumental record in the Mackenzie and Selwyn mountains of northwestern Canada. We collected 27 10 Be surface exposure ages across nine cirque and valley glacier moraines to constrain the timing of their emplacement. Cirque and valley glaciers in this region reached their greatest Holocene extents in the latter half of the Little Ice Age (1600–1850 CE). Four erratic boulders, 10–250 m distal from late Holocene moraines, yielded 10 Be exposure ages of 10.9–11.6 ka, demonstrating that by ca. 11 ka, alpine glaciers were no more extensive than during the last several hundred years. Estimated temperature change obtained through reconstruction of equilibrium line altitudes shows that since ca. 1850 CE, mean annual temperatures have risen 0.2–2.3 °C. We use our glacier chronology and the Open Global Glacier Model (OGGM) to estimate that from 1000 CE, glaciers in this region reached a maximum total volume of 34–38 km 3 between 1765 and 1855 CE and had lost nearly half their ice volume by 2019 CE. OGGM was unable to produce modeled glacier lengths that match the timing or magnitude of the maximum glacier extent indicated by the 10 Be chronology. However, when applied to the entire Mackenzie and Selwyn mountain region, past millennium OGGM simulations using the Max Planck Institute Earth System Model (MPI-ESM) and the Community Climate System Model 4 (CCSM4) yield late Holocene glacier volume change temporally consistent with our moraine and remote sensing record, while the Meteorological Research Institute Earth System Model 2 (MRI-ESM2) and the Model for Interdisciplinary Research on Climate (MIROC) fail to produce modeled glacier change consistent with our glacier chronology. Finally, OGGM forced by future climate projections under varying greenhouse gas emission scenarios predicts 85 % to over 97 % glacier volume loss by the end of the 21st century. The loss of glaciers from this region will have profound impacts on local ecosystems and communities that rely on meltwater from glacierized catchments.

54 ENVIRONMENTAL SCIENCES↗

Managing Multi-Instrument Data Streams in Secure Environments

The capture and curation of all primary instrument data is a potentially valuable source of added insight into experiments or diagnostics in laboratory experiments. The data can, when properly curated, enable analysis beyond the current practice that uses just a subset of the as-measured data. Complete curated data can also be input for machine learning and other data exploration tools. Conveniently storing and accessing instrument data requires that the instruments are connected to databases and users through a networking infrastructure. This infrastructure needs to accommodate a wide array of instruments which can range from single laboratory mounted probes for environment monitoring to computers managing multiple instruments. These resources may also include mobile devices on which researchers record instrument and experiment state related notes. These varied data sources bring with them the challenges of different communications capabilities and protocols as well as the primary data typically being produced in proprietary formats. These challenges are further compounded when the instruments need to operate in secure environments such as required in national laboratories. We will discuss the SmartLab, an ongoing effort to set up a system for instrument and simulation data curation at NASA Langley Research Center. We will outline the challenges faced in managing the data sources required for ongoing research activities and the solutions that are being considered and implemented to address those challenges.

instrument data management↗

Piezoelectric Driver for Incremental Motion

Vibrating device containing two piezoelectric ceramic slabs acts as mechanical driver. Eventually substitutes for small continuous or stepping electric motors of slow to moderate speeds. Piezoelectric driver simple in construction, requires no precise dimensions, inexpensive to make, and needs no lubrication. Not damaged by stalling or overloads and safe for use in explosive atmospheres; Motion controllable in micron-size increments, and holds position when power turned off. Potential applications as positioner or mover. Used to position instrument pointers, antennas, or solar panels; to focus lenses; or operate tuners, recording instruments, or valves.

Bruman, Joseph R.↗

A Study of Taking off and Landing an Airplane

This report covers the results of an investigation carried on at the Langley Memorial Aeronautical Laboratory of the National Advisory Committee for Aeronautics for the purpose of discussing the various methods of effecting the take-off and the landing of an airplane, and to make a direct analysis of the control movements, the accelerations, and air speeds during these the maneuvers. The recording instruments developed at the laboratory were used in this test and the records obtained by them were made the basis for a comparative study of the two extreme methods of taking off (the tail-high and tail-low methods) and of various types of landings. The records should be of considerable value to a student pilot in enabling him to visualize the movements of the controls and the consequent effect upon the air speed and acceleration.

Carroll, T↗

THE SuperTIGER Instrument: Measurement of Elemental Abundances of Ultra-Heavy Galactic Cosmic Rays

The SuperTIGER (Super Trans-Iron Galactic Element Recorder) instrument was developed to measure the abundances of galactic cosmic-ray elements from Ne-10 to Zr-40 with individual element resolution and the high statistics needed to test models of cosmic-ray origins. SuperTIGER also makes exploratory measurements of the abundances of elements with 40 < Z < or = 60 and measures the energy spectra of the more abundant elements for Z < or = 30 from about 0.8 to 10 GeV/nucleon. This instrument is an enlarged and higher resolution version of the earlier TIGER instrument. It was designed to provide the largest geometric acceptance possible and to reach as high an altitude as possible, flying on a standard long-duration 1.11 million cu m balloon. SuperTIGER was launched from Williams Field, McMurdo Station, Antarctica, on 2012 December 8, and made about 2.7 revolutions around the South Pole in 55 days of flight, returning data on over 50 x 10(exp 6) cosmic-ray nuclei with Z > or = 10, including approx.1300 with Z > 29 and approx.60 with Z > 49. Here, we describe the instrument, the methods of charge identification employed, the SuperTIGER balloon flight, and the instrument performance.

abundances↗

Modeling of Instrument Landing System (ILS) localizer signal on runway 25L at Los Angeles International Airport

A joint NASA/FAA flight test has been made to record instrument landing system (ILS) localizer receiver signals for use in mathematically modeling the ILS localizer for future simulation studies and airplane flight tracking tasks. The flight test was conducted on a portion of the ILS localizer installed on runway 25L at the Los Angeles International Airport. The tests covered the range from 10 to 32 n.mi. from the localizer antenna. Precision radar tracking information was compared with the recorded localizer deviation data. Data analysis showed that the ILS signal centerline was offset to the left of runway centerline by 0.071 degrees and that no significant bends existed on the localizer beam. Suggested simulation models for the ILS localizer are formed from a statistical analysis.

Hueschen, Richard M.↗