Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Noise Radar Approach for Interrogating SAW Sensors Using Software Defined Radio

Passive, wireless surface acoustic wave (SAW) sensor systems can be approached from a radar perspective, where the SAW device is thought of as a cooperative target. Here, this paper investigates the use of a commercial-off-the-shelf software defined radio to interrogate wireless SAW sensors with a randomly generated interrogation pulse. The USRP B200mini is utilized as the transceiver platform with custom field-programmable gate array (FPGA) modifications to generate the random interrogation waveform and provide synchronization and buffering to the received signal. Each transmit sample bit in the FPGA is fed by an independent linear-feedback shift register, which generates pseudo-random I and Q samples for the interrogation pulse. An RF daughterboard has also been developed and integrated with the B200mini to increase the transmit power, provide filtering of the RF signals, and switch a signal antenna between the transmit and receive channels. Radio control and matched filter correlator post-processing are accomplished using Python. Design and implementation details for the FPGA modifications, RF daughterboard, and post-processing are discussed. Lastly, the system is demonstrated by wirelessly interrogating SAW temperature sensors at 915 MHz.

47 OTHER INSTRUMENTATION↗

Detectors for Active Interrogation Applications

Active interrogation creates an environment that is particularly challenging from a radiation-detection standpoint: the elevated background levels from the source can mask the desired signatures from the SNM. Neutron based interrogation experiments have shown that nanosecond-level timing is required to discriminate induced-fission neutrons from the scattered source neutrons. Previous experiments using high-energy bremsstrahlung X-rays have demonstrated the ability to induce and detect prompt photofission neutrons from single target materials; however, a real-world application would require spectroscopic capability to discern between photofission neutrons emitted by SNM and neutrons emitted by other reactions in non-SNM. Using digital pulseshape discrimination, organic liquid scintillators are capable of reliably detecting neutrons in an intense gamma-ray field. Photon misclassification rates as low as 1 in 10 6 have been achieved, which is approaching the level of gaseous neutron detectors such as 3 He without the need for neutron moderation. These scintillators also possess nanosecond-timing resolution, making them candidates for both neutron-and photon-driven active interrogation systems. Lastly, we have applied an array of liquid and NaI(Tl) scintillators to successfully image 13.7 kg of HEU interrogated by a DT neutron generator; the system was in the direct presence of the accelerator during the experiment.

36 MATERIALS SCIENCE↗

Determining 235 U enrichment in bulk uranium items using dual-energy interrogation with delayed neutron measurement

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the relatively high penetrability of neutrons, providing the ability to measure uranium mass in large, dense configurations. Because the emitted neutrons from 235 U and 238 U in such configurations are, for all practical purposes, indistinguishable, established active measurement techniques require many representative calibration standards and/or well-known isotopic information to interpret the assay results (i.e., extract an isotopic mass from the effective mass). Here, the primary objective of this work is to investigate the ability of a dual-energy neutron interrogation technique to estimate uranium enrichment for bulk materials, which has the potential to eliminate the need for a (traditionally separate) gamma isotopic measurement. Dual neutron interrogation energies were achieved by adding a deuterium–tritium (D–T) neutron generator into the measurement chamber of the Oak Ridge National Laboratory 252 Cf Shuffler. This new technique exploits the change in fission rates as a function of interrogating neutron energy to independently determine the 235 U and 238 U content in the measurement item. Results from traditional 252 Cf measurements and the new D–T measurements were then used to develop a relationship between uranium enrichment and the ratio of the two delayed neutron count rates. Lastly, technical feasibility is successfully demonstrated using the modified 252 Cf Shuffler as a test bed, although several areas where refinements are both possible and needed before DEANI can be deployed as an analytical tool to meet specific measurement goals are identified.

252cf shuffler↗

Demonstration of active neutron interrogation of special nuclear materials using a high-intensity short-pulse-laser-driven neutron source

Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources. The measurement results reported here represent the first experimental demonstration of this interrogation approach on enriched uranium items and demonstrate the feasibility of a precise measurement using realistic nuclear materials, representative of field scenarios, even with just a single laser-driven neutron pulse. Bright pulsed sources can overcome the nuisance background of items with strong internal neutron sources, improving analytical power, while single-shot assay is attractive in high-throughput situations where time is at a premium. The science and technology of this type of neutron production is developing rapidly, and we anticipate that practical mobile interrogation systems will become available based on the detection concepts demonstrated here to meet the growing measurement needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Coherent pulse interrogation system for fiber Bragg grating sensing of strain and pressure in dynamic extremes of materials

A 100 MHz fiber Bragg grating (FBG) interrogation system is described and applied to strain and pressure sensing. The approach relies on coherent pulse illumination of the FBG sensor with a broadband short pulse from a femtosecond modelocked erbium fiber laser. After interrogation of the FBG sensor, a long multi-kilometer run of single mode fiber is used for chromatic dispersion to temporally stretch the spectral components of the reflected pulse from the FBG sensor. Dynamic strain or pressure induced spectral shifts in the FBG sensor are detected as a pulsed time domain waveform shift after encoding by the chromatic dispersive line. Signals are recorded using a single 35 GHz photodetector and a 50 G Samples per second, 25 GHz bandwidth, digitizing oscilloscope. Application of this approach to high-speed strain sensing in magnetic materials in pulsed magnetic fields to ~150 T is demonstrated. The FBG wavelength shifts are used to study magnetic field driven magnetostriction effects in LaCoO₃. A sub-microsecond temporal shift in the FBG sensor wavelength attached to the sample under first order phase change appears as a fractional length change (strain: ΔL/L<10⁻⁴) in the material. A second application used FBG sensing of pressure dynamics to nearly 2 GPa in the thermal ignition of the high explosive PBX-9501 is also demonstrated. Both applications demonstrate the use of this FBG interrogation system in dynamical extreme conditions that would otherwise not be possible using traditional FBG interrogation approaches that are deemed too slow to resolve such events.

36 MATERIALS SCIENCE↗

Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive that is, they do not require any on-board power supply such as batteries and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of current generation tags limits the performance in a cluttered sensing environment. That is, as more SAW-based sensors are added to the environment, numerous tag responses are superimposed at the receiver and decoding all or even a subset of the telemetry becomes increasingly difficult. Background clutter generated by reflectors other than the sensors themselves is also a problem, as is multipath interference and signal distortion, but the limiting factor in many remote sensing applications can be expected to be tag mutual interference. This problem may be greatly mitigated by proper design of the SAW tag waveform, but that remains an open research problem, and in the meantime, several other related questions remain to be answered including: What are the fundamental relationships between tag parameters such as bit-rate, time-bandwidth-product, SNR, and achievable collision resolution? What are the differences in optimal or near-optimal interrogator designs between noise-limited environments and interference-limited environments? What are the performance characteristics of different interrogator designs in term of parameters such as transmitter power level, range, and number of interfering tags? In this paper, we present the results of a research effort aimed at providing at least partial answers to all of these questions.

Barton, Richard J.↗

A Multi-Energy Approach for Neutron Interrogation of Uranium Items

Bulk uranium items are often measured using active neutron interrogation systems to take advantage of the high penetrability of neutrons, providing the ability to quickly and accurately measure effective uranium masses in large, dense configurations. These active techniques employ an external neutron source to induce fission in the uranium and subsequently measure emitted prompt fission or delayed neutrons. Unfortunately, the emitted neutrons from 235U and 238U are, for all practical purposes, indistinguishable; therefore, common systems such as the Active Well Coincidence Counter and other systems based on measurement of prompt or delayed fission neutrons require many representative calibration standards or known isotopic information to interpret the results, thus limiting the application of these techniques for safeguards purposes. This paper presents the motivation for a multi-energy neutron interrogation technique which aims to improve the accuracy of these NDA techniques through the use of multiple neutron interrogation sources. Potentially, the dual measurement approach will allow the mass values of the isotopes in the item to be independently determined while minimizing the number of representative standards needed and/or eliminating the need for prior knowledge of the isotopic information. This work examines the change in fission rates with differing interrogating neutron energy and, therefore, the potential of this new technique to independently measure the masses of 235U and 238U in the measurement item. Initial simulation and measurement results will be presented.

Hayward, Jason P.↗

Measurements of Short-Lived Isomers from Photofission as a Method of Active Interrogation for Special Nuclear Materials

Isomeric fission products, such as 134m Te (T 1/2 = 164 ns) and 136m Xe (T 1/2 = 2.95 μs), are proposed as a signature of special nuclear materials in active interrogation applications. To test this conjecture, monoenergetic 9, 11, and 13 MeV photons from the HIγS facility are used to induce fission of 235 U, 238 U, and 239 Pu targets. The de-excitation γ rays of the isomers are measured using time-gated spectroscopy with high-purity germanium detectors. The 134m Te and 136m Xe isomers are detected and identified by the energy and decay half-life of their characteristic γ-ray transitions. The ratio of yields for these two signature γ rays, corresponding to 134m Te/( 136m Xe + 136 I), is found to be strongly correlated with the identity of the fissioning nuclei. These results show that fission-product isomers may be used in active interrogation to detect and identify special nuclear materials, even providing information on the isotopic enrichment. In conclusion, the feasibility of an active interrogation scenario using a bremsstrahlung beam is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Neutron Based Interrogation System For SNM In Cargo

A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo. The RAPID technique allows for the interrogation of containers at neutron production rates between {approx}1x10{sup 8} neutrons/s and {approx}3x10{sup 8} neutrons/s. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10{sup -4} false positive rate per interrogated voxel of cargo. Detection times of 5 minutes were found for a maximally loaded cargo container uniformly filled with iron and as low as 1 second in containers loaded to 1/4 of full capacity with either iron or wood. The worse case system performance, 30 minutes interrogation time, occurs for a maximally loaded container containing wood at 0.4 g/cm{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonmagnetized Collisional Plasma Parameter Estimation From Two Frequency Signal Interrogation Attenuation

A nonmagnetized collisional plasma parameter estimator from two frequency signal interrogation attenuation is developed. The plasma parameters that are estimated are the plasma frequency, electron neutral momentum collision frequency, and the plasma thickness. The plasma frequency and electron neutral momentum collision frequency are considered uniform across the plasma thickness. The relative permittivity is defined, and the complex index of refraction is developed. Using this definition and applying the plasma frequency, electron neutral momentum collision frequency, the radial propagation frequency, and plasma thickness, an attenuation is determined for known cases. The development of the estimator is discussed. The estimator uses a performance index where the minimum difference between the plasma frequencies and electron neutral momentum collision frequencies is determined for the two signal interrogation frequencies under the constraint of the same plasma thickness. The estimator was developed in three stages which include iterative, sequential, and adaptive. The setups of the iterative, sequential, and adaptive approaches are discussed. The impact of the interrogation frequency and the estimator setup is investigated. The estimator in the three development stages is compared with known cases and the plasma parameter estimator performance is quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was used to address the high-rate challenge in used nuclear fuel assay based on photofission technique. First, a standard HPGe preamplifier was modified to improve its capabilities in high-rate pulsed photofission environment. Second, advanced pulse processing algorithms were shown to greatly improve throughput rate without large sacrifice in energy resolution at ultra-high input count rate. Two customized gamma spectroscopy systems were also developed in real-time on FPGAs. They were shown to have promising performance matching available commercial units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nimbus 4/IRLS Balloon Interrogation Package (BIP)

The balloon interrogation package (BIP), an integral part of the overall interrogation, recording, and location subsystems (IRLS) for the Nimbus 4 program, is described. The BIP is a self-contained, integrated transponder designed to be carried aloft by a constant altitude, superpressure balloon to an altitude of 67,000 or 78,000 feet. After launch the BIP senses high-altitude balloon overpressure and temperature, and upon receipt of an interrogated command from the IRLS aboard the Nimbus 4 satellite, the BIP enodes the data on a real-time basis into a pulse-code modulation (PCM) format and transmits this data to the satellite. A summary of the program activity to produce 30 BIP systems and to support balloon launches from Ascension Island is presented.

Source record↗

Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators

A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.

Miranda, Felix Antonio↗

A Web Architecture to Geographically Interrogate CHIRPS Rainfall and eMODIS NDVI for Land Use Change

Monitoring of rainfall and vegetation over the continent of Africa is important for assessing the status of crop health and agriculture, along with long‐term changes in land use change. These issues can be addressed through examination of long‐term precipitation (rainfall) data sets and remote sensing of land surface vegetation and land use types. Two products have been used previously to address these goals: the Climate Hazard Group Infrared Precipitation with Stations (CHIRPS) rainfall data, and multi‐day composites of Normalized Difference Vegetation Index (NDVI) from the USGS eMODIS product. Combined, these are very large data sets that require unique tools and architecture to facilitate a variety of data analysis methods or data exploration by the end user community. To address these needs, a web‐enabled system has been developed to allow end‐users to interrogate CHIRPS rainfall and eMODIS NDVI data over the continent of Africa. The architecture allows end‐users to use custom defined geometries, or the use of predefined political boundaries in their interrogation of the data. The massive amount of data interrogated by the system allows the end‐users with only a web browser to extract vital information in order to investigate land use change and its causes. The system can be used to generate daily, monthly and yearly averages over a geographical area and range of dates of interest to the user. It also provides analysis of trends in precipitation or vegetation change for times of interest. The data provided back to the end‐user is displayed in graphical form and can be exported for use in other, external tools. The development of this tool has significantly decreased the investment and requirements for end‐users to use these two important datasets, while also allowing the flexibility to the end‐user to limit the search to the area of interest.

Burks, Jason E.↗

Wireless Interrogation of a High Temperature Antenna Sensor Without Electronics

This paper presents a novel interrogation mechanism for an antenna sensor subjected to high temperatures. In sensor node, an Ultra-wide Band (UWB) microstrip antenna was used as a wireless Tx/Rx transceiver to amplify the reflected interrogation signal from the temperature-sensing element, i.e. the patch antenna-sensor. A microstrip delay line was used to connect the Tx/Rx antenna and the antenna-sensor so that the reflected signal from the sensor node is delayed and can be separated from the background clutter using time-domain (T-D) gating technique. In this paper, the principle of operation of the proposed interrogation mechanism is first discussed, followed by the design and simulations of the sensor node circuitry. Finally, a temperature test was conducted to validate the wireless temperature sensing performance of the antenna sensor.

Tchafa, Franck Mbanya↗

Active-Interrogation Measurements of Fast Neutrons from Induced Fission in Low-Enriched Uranium

A detection system was designed with MCNPX-PoliMi to measure induced-fission neutrons from U-235 and U-238 using active interrogation. Measurements were then performed with this system at the Joint Research Centre (JRC) in Ispra, Italy on low-enriched uranium samples. Liquid scintillators measured induced fission neutron to characterize the samples in terms of their uranium mass and enrichment. Results are presented to investigate and support the use of organic liquid scintillators with active interrogation techniques to characterize uranium containing materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-field strain and temperature measurements in a (RE)Ba 2 Cu 3 O 7–x coil via Rayleigh-backscattering interrogated optical fibers

(RE)Ba 2 Cu 3 O 7-x (REBCO) conductors have overcome technical challenges related to manufacturing quality, length homogeneity, scale-up of piece-length, and joints. There is one remaining technical challenge, however, which is common to all high temperature superconductors and lies in effective detection of failure to prevent material degradation. An innovative technique based on optical fibers interrogated by Rayleigh backscattering has been shown to have advantages over voltage taps at detecting incipient faults. Prior work has experimentally demonstrated the technique in several implementation scenarios, including direct integration of optical fibers into superconducting conductors and cables to create a class of ‘SMART’ conductors and cables that are able to monitor their own health. In this paper, the magnet monitoring technique based on Rayleigh backscattering interrogated optical fibers has been experimentally studied in a model coil subject to external magnetic field, where different fiber integration methods are used to increase selectivity of the fiber sensor to temperature. Results show that the spectral shift displays different features during strain and thermal transients. The implications of the results in terms of potential and limitations of each sensor as well as strain-temperature decoupling are discussed.

36 MATERIALS SCIENCE↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗