Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The predicted deviation from the Z-sq dependence of the ion chamber and the Cerenkov counter response on the HEAO-3 experiment

The influence of the Mott cross section in producing a departure from a Z-sq dependence in the Heavy Nuclei Experiment instrument on board the HEAO-3 satellite is examined, along with the related problem of secondary electron energy transport through the instrument. A Monte Carlo method of electron transport and a modification of the Laulainen and Bichsel (1972) method were used to calculate energy deposition in the chamber, and corrections to the Cerenkov counter response were made. A maximum correction of a change of Z values of a -4 at Z equals 78 was found, and further calculations to determine the Mott cross sections for Z between 26-50 are indicated.

Derrickson, J. H.↗

Relative abundances of elements (20 or = Z or = 28) at energies up to 70 GeV/amu using relativistic rise in ion chambers

The results of a new balloon borne cosmic ray detector flown from Palestine, TX in Sept., 1982 are discussed. The exposure of 62 square meter-ster-hr is sufficient to prove the concept of using gas ionization chambers as energy measuring devices in the relativistic rise region. The abundances, relative Fe-26, of the pure secondaries Cr-22 and Ti-24, the pure primary Ni26, and the mixed primary and secondary Ca-20 between 6 and 70GeV/amu were measured.

Barthelmy, S. D.↗

Stigmatically focusing partial pressure analyzer with dual chamber ion source

The partial pressure analyzer developed has a high absolute sensitivity and high resolution. Interaction effects, as they occur in conventional partial pressure analyzers between the heating filament for the emission of electrons and the residual gas, are suppressed by removing the heating filament from the measurement area. The electron beam is generated in an auxiliary vacuum compartment, and passes subsequently through an aperture into the ionization compartment. The probability is small, therefore, that the presence of substances produced at the heating filament by chemical reactions and thermal decompositions will have disturbing effects. The high sensitivity and resolution of the instrument are obtained with the aid of an electron path configuration of unconventional characteristics.

Rasskopf, Klaus F.↗

Convert Ten Foot Environmental Test Chamber into an Ion Engine Test Chamber

The 10 Foot Space Simulator at the Jet Propulsion Laboratory has been used for the last 40 years to test numerous spacecraft, including the Ranger series, several Mariner class, among many others and finally, the Spirit and Opportunity Mars Rovers. The request was made to convert this facility to an Ion Engine test facility, with a possible long term life test. The Ion engine was to propel the Prometheus spacecraft to Jupiter's moons. This paper discusses the challenges that were met, both from a procedural and physical standpoint. The converted facility must operate unattended, support a 30 Kw Ion Engine, operate economically, and be easily converted back to former operation as a spacecraft test facility.

ion engines↗

Computational Model Tracking Primary Electrons, Secondary Electrons, and Ions in the Discharge Chamber of an Ion Engine

Computational modeling of the plasma located in the discharge chamber of an ion engine is an important activity so that the development and design of the next generation of ion engines may be enhanced. In this work a computational tool called XOOPIC is used to model the primary electrons, secondary electrons, and ions inside the discharge chamber. The details of this computational tool are discussed in this paper. Preliminary results from XOOPIC are presented. The results presented include particle number density distributions for the primary electrons, the secondary electrons, and the ions. In addition the total number of a particular particle in the discharge chamber as a function of time, electric potential maps and magnetic field maps are presented. A primary electron number density plot from PRIMA is given in this paper so that the results of XOOPIC can be compared to it. PRIMA is a computer code that the present investigators have used in much of their previous work that provides results that compare well to experimental results. PRIMA only models the primary electrons in the discharge chamber. Modeling ions and secondary electrons, as well as the primary electrons, will greatly increase our ability to predict different characteristics of the plasma discharge used in an ion engine.

Mahalingam, Sudhakar↗

The UH-nuclei cosmic ray detector on the third High Energy Astronomy Observatory

The third High Energy Astronomy Observatory satellite (HEAO-3) carries a particle telescope for the detection of highly charged cosmic ray nuclei. These nuclei, which have Z equal to or greater than 28, are much rarer than the lower charged nuclei in the cosmic radiation. As a consequence, this particle telescope was required to have a large collecting area as well as an ability to resolve individual elements. This paper describes the telescope, composed of large area parallel plate ionization chambers, multiwire ion chamber hodoscopes and a Cherenkov radiation detector. The resulting telescope has a total geometry factor of 59,000 sq cm sr and is capable of measuring the charges of nuclei in the range Z = 14-120.

Binns, W. R.↗

Picoampere charged particle beam monitor.

Description of a transmission ion chamber for charged particles designed to give continuous indication of beam symmetry and magnitude. The chamber consists of four separate ion chambers. Signals from opposing chambers are compared to determine beam symmetry and summed to obtain a beam intensity signal. The system is simple and offers good linearity at low cost for proton beam currents in the range of 1 to 100 pA.

Smathers, J. B.↗

Enhanced thermal emittance of space radiators by ion-discharge chamber texturing

The discharge chamber of a 30-cm argon ion source was successfully used to texture potential space radiator materials for the purpose of obtaining values of thermal emittance greater than 0.85 at 700 and 900 K. Some samples were also treated in acid prior to texturing. To evaluate the durability of the textured materials to atomic oxygen, samples were exposed to an RF air plasma environment. The spectral emittance between 2.0 anf 15.0 microns was measured before and after the textured materials were exposed to the plasma asher. The results indicate that copper with extremely high values of emittance after texturing (0.978 and 0.983) at 700 and 900 K, respectively,did not change its values of emittance after ashing, whereas the emittance of stainless steel fell below 0.85 after ashing. These data, along with scanning electron photomicrographs, and the results of texturing and ashing titanium and Nb(1)Zr are presented .

Mirtich, Michael J.↗

Proton dosimeter design for distributed body organs

A simple dosimeter design has been developed by NASA to monitor the space proton dose (in rads) to a distributed body organ as a linear combination of ion chambers with varying wall thickness. Estimated doses are given for ion chambers of thickness 2, 3, 4, and 5 g/sq cm. The analytical equation used to calculate the dose distribution factor is also given.

Wilson, J. W.↗

A measurement of the relativistic rise in xenon-filled ionisation chambers for cosmic ray iron

The relativistic rise of ionization in a pair of xenon-filled pulse ion chambers was measured for primary iron nuclei during a recent balloon flight. Energy calibration over the range 21.5-60 GeV/n was made with a Freon-12 gas Cerenkov detector. This allowed a comparison with recent calculations of the relativistic rise in xenon counters and an estimate of the ion chamber resolution above 21.5 GeV/n to be made.

Gregory, J. C.↗

The study of efficient low-power diffraction designs

Topics covered include the design and fabrication of: (1) a nuclear radiation monitor for use in measuring the radiation environment of the space shuttle payload bay (part of the Spacelab 2 payload; (2) a parallel plate ion chamber for measuring ionization loss by relativistic heavy ions and (3) ionization chambers and proportional chambers for the active radiation detector on Spacelab 1. An experiment to measure the response of ion chambers and Cerenkox counters to relativistic argon and iron atoms is also described.

Gregory, J. C.↗

Ion-thruster propellant utilization.

Maximum propellant utilization in a mercury electron-bombardment thrustor is evaluated. The primary-electron region in the ion chamber of a bombardment thrustor is analyzed at maximum utilization. Both the analysis and experimental data from a range of ion-chamber configurations show a nearly constant loss rate for un-ionized propellant at maximum utilization over a wide range of total propellant flow rate. The discharge loss level of 1000 eV/ion was used to define maximum utilization. The exact level of this definition has no effect on the qualitative results and little effect on the quantitative results. The results obtained are particularly significant whenever efficient throttled operation is required.

Kaufman, H. R.↗

Some methods in high energy cosmic ray measurement

Problems concerning ion chamber and emulsion detection techniques for high energy cosmic ray measurement are investigated. The calculation of the average energy actually deposited in an ion chamber by an ultra-high energy particle of large mass and charge is examined. A calculational scheme already applied successfully to particles of charge 1 is extended. Also, the calibration of a plate of plastic scintillator for measurement of the position of a cosmic ray shower passing through it is discussed. The method of calibration is to inject pulses of flight at known positions on the plate and record the responses of photomultiplier tubes at the corner of the plate.

Shand, J. B., Jr.↗

Ion-thruster propellant utilization

The evaluation and understanding of maximum propellant utilization, with mercury used as the propellant are presented. The primary-electron region in the ion chamber of a bombardment thruster is analyzed at maximum utilization. The results of this analysis, as well as experimental data from a range of ion-chamber configurations, show a nearly constant loss rate for unionized propellant at maximum utilization over a wide range of total propellant flow rate. The discharge loss level of 1000 eV/ion was used as a definition of maximum utilization, but the exact level of this definition has no effect on the qualitative results and little effect on the quantitative results. There are obvious design applications for the results of this investigation, but the results are particularly significant whenever efficient throttled operation is required.

Kaufman, H. R.↗

The normalization of solar X-ray data from many experiments.

A conversion factor is used to convert Geiger (GM) tube count rates or ion chamber currents into units of the incident X-ray energy flux in a specified passband. A method is described which varies the passband to optimize these conversion factors such that they are relatively independent of the spectrum of the incident photons. This method was applied to GM tubes flown on Explorers 33 and 35 and Mariner 5 and to ion chambers flown on OSO 3 and OGO 4. Revised conversion factors and passbands are presented, and the resulting absolute solar X-ray fluxes based on these are shown to improve the agreement between the various experiments. Calculations have shown that, although the GM tubes on Explorer 33 viewed the Sun off-axis, the effective passband did not change appreciably, and the simple normalization of the count rates to the count rates of a similar GM tube on Explorer 35 was justified.

Wende, C. D.↗

Plasma Emission Characteristics from a High Current Hollow Cathode in an Ion Thruster Discharge Chamber

The presence of energetic ions produced by a hollow cathodes operating at high emission currents (greater than 5A) has been documented in the literature. In order to further elucidate these findings, an investigation of a high current cathode operating in an ion thruster discharge chamber has been undertaken. Using Langmuir probes, a low energy charged particle analyzer and emission spectroscopy, the behavior of the near-cathode plasma and the emitted ion energy distribution was characterized. The presence of energetic ions was confirmed. It was observed that these ions had energies in excess of the discharge voltage and thus cannot be simply explained by ions falling out of plasma through a potential difference of this order. Additionally, evidence provided by Langmuir probes suggests the existence of a double layer essentially separating the hollow cathode plasma column from the main discharge. The radial potential difference associated with this double layer was measured to be of order the ionization potential.

Foster, John E.↗