Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exploring Causes of Beam Loss at CEBAF

At Jefferson Lab, the Continuous Electron Beam Accelerator (CEBAF) features a unique design with two linear accelerators and two arc sections allowing for multiple turns of the electron beam, as well as four experimental end stations. This topology leads to increased beam losses, especially in the spreader and recombiner regions connecting the arcs to the linacs and in the extraction regions connecting the experimental end stations to the accelerator. These losses result in equipment activation and operational interruptions. Recent upgrades to the facility’s diagnostic systems, including the addition of xenon ion chambers, have provided higher-resolution data regarding these loss events. Building on this improved observational capability, we are developing a simulation framework using optics codes and the Geant4-based BDSIM to model beam extinction and halo formation in these regions. This work aims to correlate simulation results with experimental data to isolate the causes of beam loss and inform future machine tuning strategies. We present a summary of conclusions drawn from recent operational studies and outline a plan to model the beam loss and validate the simulations.

Matthews, C. [Old Dominion Univ., Norfolk, VA (Uni↗

Unattended Dual Current Monitor (UDCM)

Researchers at Los Alamos National Laboratory have developed the Unattended Dual Current Monitor (UDCM). The UDCM is an ideal solution for current measurement needs such as ion chamber gamma measurements. This data acquisition system simplifies hardware requirements for current applications, and provides added reliability, flexibility, and compatibility as compared with the legacy Miniature Gamma Ray and Neutron Detector (MiniGRAND) technology. It is lightweight, can be portable or mounted, is manufactured using COTS parts, and features a modern Internet-of-Things (IoT) enabled design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fork Experiments in the Hot Cell Using Spent Fuel Rods for International Nuclear Safeguards

This work leveraged the rare availability of 25 full-length pressurized water reactor spent fuel rods and 1 irradiated mixed-oxide rod at an Oak Ridge National Laboratory hot cell. This was done to collect measurement data with two Fork detectors to assess the detectors’ capability of verifying operator declaration data and detecting partial defects in spent fuel, which are the two primary goals of international safeguards on spent nuclear fuel. The data can also be used to benchmark the ORIGEN module, which has been adopted in the International Atomic Energy Agency’s (IAEA’s)/European Atomic Energy Community’s (Euratom’s) Integrated Review and Analysis Program to predict the Fork detector count rates in real time. In this project, the authors first calibrated two Fork detectors—a standard one and a modified one—by using known strong neutron and gamma sources. Then, the authors measured all 26 fuel rods at multiple locations along the length. The fuel rods were then assembled into three arrays—2 × 2, 3 × 3, and 5 × 5—by using specially designed support grids to mimic fuel assemblies and measure the arrays with both detectors. For the 5 × 5 array, 4 and 8 fuel rods of the array were replaced in two separate cases with short stainless-steel rods to mimic two partial defect scenarios, and the arrays were measured before and after the replacements. Polyethylene blocks were used in this experiment to mimic water. The results show that the Fork detectors were able to verify operator declarations and detect partial defects in spent fuel, and the authors were the first to demonstrate this through experiments. A discovery was also made that determined the root cause of the nonlinear response to gamma dose in the ion chambers used in IAEA and Euratom’s Fork detectors. After the experiments, both detectors were retrieved from the hot cell for future use. The data collected in this project will be used in a parallel International Nuclear Safeguards Engagement Program (INSEP) project to enhance the safeguards in the Finnish spent fuel encapsulation plant, and the data will be useful to other projects in the future given the increased safeguards needs due to spent fuel transfer and disposal activities worldwide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SFRC Measurement Control Summary - FY23 Q3/Q4

Measurements with the Spent Fuel Rod Counter (SFRC) to be performed bi annually include 3 He detector efficiency checks (in both modules) and ion chamber channel tests with a pocket pulser. These measurements will all be performed at TA-35, building 27 where the SFRC is stored. Refer to LA-UR-22-31737 and LA-CP-22-20079 SFRC measurement control documents for a description of additional tests. Note that during this measurement period, counts could not be confirmed for the Si detectors, as an analog pulse to TTL box necessary for the DAQs to communicate with the detectors was still under construction. For this reason, typical measurements at the Calibrated Dose Facility were not performed for the second half of FY23. When these components are finished by the NEN electrical shop, the Si detectors will be implemented into these measurement control checks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER 484: AFRRI Field Characterization Measurements [Slides]

This lecture includes discussion on the future work of finalizing the data analysis with dose as a function of radial distance and ion chamber integral. Further on agenda is to write manuscript of AFRRI dose characterization and write manuscripts of all NCSP-funded NAD work. Finally, it talks on the goal to publish in Radiation Measurements special issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Water production for coffee brewing by electrodeionization

A resin-wafer electrodeionization (RW-EDI) apparatus for purifying water for coffee brewing comprises a cathode; an anode; and multiple porous solid resin wafer exchange units arranged in a stack between the cathode and the anode, and an air distributor adapted and arranged to aerate the water to be purified. Each unit comprises a monovalent cation exchange membrane (CEM), an anion exchange membrane (AEM), and an ion exchange resin wafer between the CEM and the AEM, which is in contact with, and in fluid flow connection with the CEM and AEM. Each resin wafer comprises a cation exchange resin and an anion exchange resin. The units are oriented with the CEM facing the cathode and the AEM facing the anode, with space between the units defining ion concentrate chambers. Bipolar ion exchange membranes separate the anode and cathode from their nearest resin wafer exchange units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improvements to In-Canal Assay of High Specific Activity 60Co at the ATR

Improvements to the quality of measurements in the assaying of High Specific Activity (HSA) cobalt 60 produced at the Advanced Test Reactor at the Idaho National Laboratory are presented. Such assays are conducted regularly between cycles at the ATR, and due to the radiological safety concerns, they are performed within the ATR canal. A standard ion chamber detector was placed in a collimated assay tube within the canal. Another tube, parallel to the detector, was used to position various cobalt 60 standards and targets. The collimated port between these tubes allows for the targets to be pulled across via a winch system. Previous measurements were performed at discrete 1.5-inch steps using a hand-cranked winch system. Charge was collected and integrated for 10 seconds at each discrete step during a scan. Two substantial improvements to the assay include an electronically controlled, motor-driven winch system and a software controlled continuous charge collection. Combined, these changes improved the quality of measurements as well as streamline the assay process. Further examination of these charge profiles indicated a reasonable amount of photon scattering, or shine, before a line-of-sight is established. This created inaccuracies in the reported activity of the cobalt targets. A series of MCNP-6.3 calculations were performed in an effort to quantify and correct for this shine effect. The results of the calculations and how they were employed to a create shine correction factor for the in-canal cobalt assay at the ATR are presented. The overall bias showed an overestimation of the HSA cobalt 60 activity by around 7-8%.

07 - ISOTOPES AND RADIATION SOURCES↗

The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers

Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High reliability, long lifetime, negative ion source

A negative ion source includes a plasma chamber, a microwave source, a negative ion converter, a magnetic filter and a beam formation mechanism. The plasma chamber contains gas to be ionized. The microwave source transmits microwaves to the plasma chamber to ionize the gas into atomic species including hyperthermal neutral atoms. The negative ion converter converts the hyperthermal neutral atoms to negative ions. The magnetic filter reduces a temperature of an electron density provided between the plasma chamber and the negative ion converter. The beam formation mechanism extract the negative ions.

Sherman, Jason D.↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-beam-assisted growth of cesium-antimonide photocathodes

We report on the novel use of a Cs+ ion gun for an ion-beam-assisted molecular-beam-epitaxy (IBA-MBE) method to sequentially deposit Cs-Sb cathodes on room temperature substrates as opposed to the standard technique of thermal evaporation on elevated-temperature substrates. The details of the ultrahigh-vacuum chamber, the Cs+ ion source, and the growth technique are elaborated. The final quantum efficiency (QE) is reasonably good for Cs-Sb cathodes grown on two different substrates—Si (100) and strontium titanate—and is comparable to the QE of cathodes grown using thermal sources. This suggests that IBA-MBE could be a viable alternative to grow alkali-antimonides without substrate heating, paving the way for the growth of epitaxial alkali-antimonides in a more reproducible fashion, which may help improve the efficiency of photon detectors and accelerator applications that use alkali-antimonides as electron sources.

Engineering↗

H - Ion Source RF Plasma Testing with 13 MHz and 27 MHz at the Spallation Neutron Source (SNS)

The baseline RF-driven H⁻ ion source configuration at the Spallation Neutron Source (SNS) facility uses a continuous wave (CW) 600 W 13 MHz RF system to ignite and maintain a low-density plasma inside the ion source vacuum chamber. After the continuous low-density 13 MHz plasma has been established, a pulsed (typical 1 ms pulse width and 60 Hz pulse repetition rate) 80 kW 2 MHz RF system is used to increase the plasma density to produce the pulsed H⁻ ion beam. Incremental upgrades and improvements to the SNS ion source systems have resulted in the ability to reliably operate an H⁻ ion source for SNS neutron production run cycles that can last up to four months. Conditions inside the SNS H⁻ ion source evolve throughout a four-month run cycle due to changes in impurity levels, sputtering, and erosion. As the internal ion source conditions change during the run cycle, there can also be changes in plasma stability and the 13 MHz RF power level required to ignite the plasma. This paper presents the preliminary results of testing performed on the SNS Ion Source Test Stand (ISTS) system where we looked at plasma ignition and plasma stability using 27 MHz RF in place of the baseline 13 MHz RF system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber

This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination on the angle of the ionizing particle track relative to the drift electric field is observed. An ellipsoid modified box (EMB) model of recombination describes the data across all measured angles. These measurements are used for the calorimetric energy scale calibration of the ICARUS TPC, which is also presented. The impact of the EMB model is studied on calorimetric particle identification, as well as muon and proton energy measurements. Accounting for the angular dependence in EMB recombination improves the accuracy and precision of these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗